Relative intensity calibration of the DIII-D charge-exchange recombination spectroscopy system using neutral beam injection into gas
A new calibration method for the DIII-D charge-exchange spectroscopy system produces a smoother impurity density profile compared to previous techniques, improving the accuracy of the impurity density profile reconstruction. The relative intensity calibration between the chords of the DIII-D charge-...
Saved in:
Published in | Review of scientific instruments Vol. 89; no. 10; p. 10D116 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
United States
01.10.2018
|
Online Access | Get more information |
Cover
Loading…
Abstract | A new calibration method for the DIII-D charge-exchange spectroscopy system produces a smoother impurity density profile compared to previous techniques, improving the accuracy of the impurity density profile reconstruction. The relative intensity calibration between the chords of the DIII-D charge-exchange recombination spectroscopy system is performed by firing neutral beams into the evacuated vacuum vessel pre-filled with neutral gas. Relative calibration is required in order to account for uncertainty in the 3D geometry of the neutral beam. Previous methods using helium gas have been improved by using xenon, which emits an emission line close to the commonly used carbon wavelength 5290.5 Å, as well as improved timing of the gas injection, inclusion of variations in the vessel pressure, and timing of neutral beam injection. Photoemission spectra recorded by 112 sightlines viewing 6 neutral beams are compared and used to form a relative calibration factor for each sightline. This relative calibration is shown to improve the quality of the measured ion density profile. |
---|---|
AbstractList | A new calibration method for the DIII-D charge-exchange spectroscopy system produces a smoother impurity density profile compared to previous techniques, improving the accuracy of the impurity density profile reconstruction. The relative intensity calibration between the chords of the DIII-D charge-exchange recombination spectroscopy system is performed by firing neutral beams into the evacuated vacuum vessel pre-filled with neutral gas. Relative calibration is required in order to account for uncertainty in the 3D geometry of the neutral beam. Previous methods using helium gas have been improved by using xenon, which emits an emission line close to the commonly used carbon wavelength 5290.5 Å, as well as improved timing of the gas injection, inclusion of variations in the vessel pressure, and timing of neutral beam injection. Photoemission spectra recorded by 112 sightlines viewing 6 neutral beams are compared and used to form a relative calibration factor for each sightline. This relative calibration is shown to improve the quality of the measured ion density profile. |
Author | Chrystal, C Haskey, S R Burrell, K H Grierson, B A |
Author_xml | – sequence: 1 givenname: B A surname: Grierson fullname: Grierson, B A organization: Princeton Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08543, USA – sequence: 2 givenname: K H orcidid: 0000000226391228 surname: Burrell fullname: Burrell, K H organization: General Atomics, P.O. Box 85608, San Diego, California 92186-5608, USA – sequence: 3 givenname: C orcidid: 0000000330498658 surname: Chrystal fullname: Chrystal, C organization: General Atomics, P.O. Box 85608, San Diego, California 92186-5608, USA – sequence: 4 givenname: S R orcidid: 0000000299786597 surname: Haskey fullname: Haskey, S R organization: Princeton Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08543, USA |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/30399968$$D View this record in MEDLINE/PubMed |
BookMark | eNo1kM1OwzAQhC0Eoj9w4AWQXyDFP4mTHFFLIVIlJOBe2c4mdZXYUewicufBMSrMZVejb3ekWaBL6ywgdEfJihLBH-gqIzznnF-gOSVFmeSC8RlaeH8kURml12jGCS_LUhRz9P0GnQzmE7CxAaw3YcJadkaN0XUWuwaHA-BNVVXJBuuDHFtI4CsutgU8gna9MvbM-gF0GJ3Xbpiwn3yAHp-8sS22cAqj7LAC2cegY-R-D2Kkw630N-iqkZ2H27-5RO_bp4_1S7J7fa7Wj7tEp2kWEl0IUciGprVU0GhZS2BC5JALymnBpKBQgmpAZUVE84YpXZOsZiqlIivYEt2fvw4n1UO9H0bTy3Ha_5fBfgDvTGOk |
CitedBy_id | crossref_primary_10_1088_1741_4326_ac3020 crossref_primary_10_1088_1741_4326_ab7d50 crossref_primary_10_1088_1741_4326_ab81aa crossref_primary_10_1063_5_0080075 |
ContentType | Journal Article |
DBID | NPM |
DOI | 10.1063/1.5037333 |
DatabaseName | PubMed |
DatabaseTitle | PubMed |
DatabaseTitleList | PubMed |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
Discipline | Sciences (General) |
EISSN | 1089-7623 |
ExternalDocumentID | 30399968 |
Genre | Journal Article |
GroupedDBID | --- -DZ -~X .DC .GJ 0ZJ 123 186 1UP 2-P 29P 3O- 4.4 41~ 53G 5RE 5VS 6TJ 85S 9M8 A9. AAAAW AABDS AAEUA AAPUP AAYIH AAYJJ ABFTF ABJNI ACBEA ACBRY ACGFO ACGFS ACKIV ACLYJ ACNCT ACZLF ADCTM ADIYS ADRHT AEGXH AEJMO AENEX AFATG AFFNX AFHCQ AGKCL AGLKD AGMXG AGTJO AHPGS AHSDT AIAGR AJJCW AJQPL ALEPV ALMA_UNASSIGNED_HOLDINGS AQWKA ATXIE AWQPM BDMKI BPZLN CS3 DU5 EBS EJD ESX F20 F5P FDOHQ FFFMQ HAM L7B M43 M6X M71 M73 MVM N9A NEJ NEUPN NHB NPM NPSNA O-B OHT P2P QZG RDFOP RIP RNS ROL RQS TAE TN5 UAO UHB VQA WH7 XJT XOL XSW YNT YZZ ZCG ZXP ~02 |
ID | FETCH-LOGICAL-c445t-c8668af14dabefcadae2667e7613182a61e9ebfeb58c867f2bcd05d2b416582 |
IngestDate | Sat Sep 28 08:46:21 EDT 2024 |
IsDoiOpenAccess | false |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 10 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c445t-c8668af14dabefcadae2667e7613182a61e9ebfeb58c867f2bcd05d2b416582 |
ORCID | 0000000226391228 0000000299786597 0000000330498658 |
OpenAccessLink | https://www.osti.gov/servlets/purl/1474417 |
PMID | 30399968 |
ParticipantIDs | pubmed_primary_30399968 |
PublicationCentury | 2000 |
PublicationDate | 2018-10-01 |
PublicationDateYYYYMMDD | 2018-10-01 |
PublicationDate_xml | – month: 10 year: 2018 text: 2018-10-01 day: 01 |
PublicationDecade | 2010 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Review of scientific instruments |
PublicationTitleAlternate | Rev Sci Instrum |
PublicationYear | 2018 |
SSID | ssj0000511 |
Score | 2.328996 |
Snippet | A new calibration method for the DIII-D charge-exchange spectroscopy system produces a smoother impurity density profile compared to previous techniques,... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 10D116 |
Title | Relative intensity calibration of the DIII-D charge-exchange recombination spectroscopy system using neutral beam injection into gas |
URI | https://www.ncbi.nlm.nih.gov/pubmed/30399968 |
Volume | 89 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9NAEF6lRUK9VJRneWkPHEDRFj_W9uZYNaAEiV4oUm_Vrj0LBcWJaIKAM3-l_7Mz-3BMAPG4WJbXia2dz7PfjGa-ZewJVPXI4rItshyskFpaoZA14BdfWNuokUkKahR-fVxO3spXp8XpYHDZq1paLc1B_e2XfSX_Y1W8hnalLtl_sGz3p3gBz9G-eEQL4_GvbOwr2T6DE31oXXUFTjkFwJEHEq0cT6dTMR46TSQQ8MX3-g4pFJ5hXOzvdR2XpGw5X3wN8s7DlcsjtLCibMjQgJ7hgz5AHeojkbW-C7VFUeG764PxfZZUhkTV7ktSaAiaUb7Y59wRfQeuXjaVtKJCu9C6aeLo_Sd8HbcvwTqlO9EXH0OZWih5DJmLVHU1cLjweG-bqJFAb5z33bHfUSjCLuk51zQZp74x8ye_j0SLUhAHRZJXuVfW6Nl_MXMAwNWawjv159ENCe44tMW2KkXO9JhSQnG5R8oaJavK_Hn3DjvsevzdRsjiqMvJDbYbYg5-6AG0xwbQ3mR7watf8KdBevzZLfY9Iop3iOI9RPG55Ygo7hHFNxDFf0AU7yOKe0RxhygeEMUJUbxDFD1yzhFRt9mbly9OjiYi7NMhaimLpahVWSptU9loA7bWjQakfRVUSBUxfNVlCiMwFkyh8NbKZqZukqLJDAYDhcrusO123sI9xjPZSIWUujHWSt0YRWw4rW1m89SaRO6zu34ezxZeiuUszvD93448YDtr7D1k1yx--_AIieTSPHaGvAIkAnn1 |
link.rule.ids | 783 |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Relative+intensity+calibration+of+the+DIII-D+charge-exchange+recombination+spectroscopy+system+using+neutral+beam+injection+into+gas&rft.jtitle=Review+of+scientific+instruments&rft.au=Grierson%2C+B+A&rft.au=Burrell%2C+K+H&rft.au=Chrystal%2C+C&rft.au=Haskey%2C+S+R&rft.date=2018-10-01&rft.eissn=1089-7623&rft.volume=89&rft.issue=10&rft.spage=10D116&rft_id=info:doi/10.1063%2F1.5037333&rft_id=info%3Apmid%2F30399968&rft_id=info%3Apmid%2F30399968&rft.externalDocID=30399968 |