Microcalcification detectability using a bench-top prototype photon-counting breast CT based on a Si strip detector

To investigate the feasibility of detecting breast microcalcification (μCa) with a dedicated breast computed tomography (CT) system based on energy-resolved photon-counting silicon (Si) strip detectors. The proposed photon-counting breast CT system and a bench-top prototype photon-counting breast CT...

Full description

Saved in:
Bibliographic Details
Published inMedical physics (Lancaster) Vol. 42; no. 7; p. 4401
Main Authors Cho, Hyo-Min, Ding, Huanjun, Barber, William C, Iwanczyk, Jan S, Molloi, Sabee
Format Journal Article
LanguageEnglish
Published United States 01.07.2015
Subjects
Online AccessGet more information

Cover

Loading…
Abstract To investigate the feasibility of detecting breast microcalcification (μCa) with a dedicated breast computed tomography (CT) system based on energy-resolved photon-counting silicon (Si) strip detectors. The proposed photon-counting breast CT system and a bench-top prototype photon-counting breast CT system were simulated using a simulation package written in matlab to determine the smallest detectable μCa. A 14 cm diameter cylindrical phantom made of breast tissue with 20% glandularity was used to simulate an average-sized breast. Five different size groups of calcium carbonate grains, from 100 to 180 μm in diameter, were simulated inside of the cylindrical phantom. The images were acquired with a mean glandular dose (MGD) in the range of 0.7-8 mGy. A total of 400 images was used to perform a reader study. Another simulation study was performed using a 1.6 cm diameter cylindrical phantom to validate the experimental results from a bench-top prototype breast CT system. In the experimental study, a bench-top prototype CT system was constructed using a tungsten anode x-ray source and a single line 256-pixels Si strip photon-counting detector with a pixel pitch of 100 μm. Calcium carbonate grains, with diameter in the range of 105-215 μm, were embedded in a cylindrical plastic resin phantom to simulate μCas. The physical phantoms were imaged at 65 kVp with an entrance exposure in the range of 0.6-8 mGy. A total of 500 images was used to perform another reader study. The images were displayed in random order to three blinded observers, who were asked to give a 4-point confidence rating on each image regarding the presence of μCa. The μCa detectability for each image was evaluated by using the average area under the receiver operating characteristic curve (AUC) across the readers. The simulation results using a 14 cm diameter breast phantom showed that the proposed photon-counting breast CT system can achieve high detection accuracy with an average AUC greater than 0.89 ± 0.07 for μCas larger than 120 μm in diameter at a MGD of 3 mGy. The experimental results using a 1.6 cm diameter breast phantom showed that the prototype system can achieve an average AUC greater than 0.98 ± 0.01 for μCas larger than 140 μm in diameter using an entrance exposure of 1.2 mGy. The proposed photon-counting breast CT system based on a Si strip detector can potentially offer superior image quality to detect μCa with a lower dose level than a standard two-view mammography.
AbstractList To investigate the feasibility of detecting breast microcalcification (μCa) with a dedicated breast computed tomography (CT) system based on energy-resolved photon-counting silicon (Si) strip detectors. The proposed photon-counting breast CT system and a bench-top prototype photon-counting breast CT system were simulated using a simulation package written in matlab to determine the smallest detectable μCa. A 14 cm diameter cylindrical phantom made of breast tissue with 20% glandularity was used to simulate an average-sized breast. Five different size groups of calcium carbonate grains, from 100 to 180 μm in diameter, were simulated inside of the cylindrical phantom. The images were acquired with a mean glandular dose (MGD) in the range of 0.7-8 mGy. A total of 400 images was used to perform a reader study. Another simulation study was performed using a 1.6 cm diameter cylindrical phantom to validate the experimental results from a bench-top prototype breast CT system. In the experimental study, a bench-top prototype CT system was constructed using a tungsten anode x-ray source and a single line 256-pixels Si strip photon-counting detector with a pixel pitch of 100 μm. Calcium carbonate grains, with diameter in the range of 105-215 μm, were embedded in a cylindrical plastic resin phantom to simulate μCas. The physical phantoms were imaged at 65 kVp with an entrance exposure in the range of 0.6-8 mGy. A total of 500 images was used to perform another reader study. The images were displayed in random order to three blinded observers, who were asked to give a 4-point confidence rating on each image regarding the presence of μCa. The μCa detectability for each image was evaluated by using the average area under the receiver operating characteristic curve (AUC) across the readers. The simulation results using a 14 cm diameter breast phantom showed that the proposed photon-counting breast CT system can achieve high detection accuracy with an average AUC greater than 0.89 ± 0.07 for μCas larger than 120 μm in diameter at a MGD of 3 mGy. The experimental results using a 1.6 cm diameter breast phantom showed that the prototype system can achieve an average AUC greater than 0.98 ± 0.01 for μCas larger than 140 μm in diameter using an entrance exposure of 1.2 mGy. The proposed photon-counting breast CT system based on a Si strip detector can potentially offer superior image quality to detect μCa with a lower dose level than a standard two-view mammography.
Author Cho, Hyo-Min
Ding, Huanjun
Barber, William C
Iwanczyk, Jan S
Molloi, Sabee
Author_xml – sequence: 1
  givenname: Hyo-Min
  surname: Cho
  fullname: Cho, Hyo-Min
  organization: Department of Radiological Sciences, University of California, Irvine, California 92697
– sequence: 2
  givenname: Huanjun
  surname: Ding
  fullname: Ding, Huanjun
  organization: Department of Radiological Sciences, University of California, Irvine, California 92697
– sequence: 3
  givenname: William C
  surname: Barber
  fullname: Barber, William C
  organization: DxRay Inc., Northridge, California 91324
– sequence: 4
  givenname: Jan S
  surname: Iwanczyk
  fullname: Iwanczyk, Jan S
  organization: DxRay Inc., Northridge, California 91324
– sequence: 5
  givenname: Sabee
  surname: Molloi
  fullname: Molloi, Sabee
  organization: Department of Radiological Sciences, University of California, Irvine, California 92697
BackLink https://www.ncbi.nlm.nih.gov/pubmed/26133636$$D View this record in MEDLINE/PubMed
BookMark eNo1z8tOQyEYBGBiNPaiC1_A8AKnwg-HwtI0Wk1qXFjXDXDAYlogQBd9e2usq5nF5Etmgi5jig6hO0pmlFL5QGdcAQhJLtAY-Jx1HIgaoUmt34QQwXpyjUYgKGOCiTGqb8GWZPXOBh-sbiFFPLjmbNMm7EI74kMN8QtrbFy0266ljHNJLbVjdjhvTy12Nh1i-12Z4nRteLHGRlc34BOm8UfAtZWQz24qN-jK6111t-ecos_np_XipVu9L18Xj6vOck5J53nvrdLM9J6CIHIw0Gsx9IIpbaT0RMne-bkcCDEOQHllCABnRqq5NBxgiu7_3Hwwezdscgl7XY6b__fwAwVdXAI
CitedBy_id crossref_primary_10_1088_1748_0221_15_10_P10029
crossref_primary_10_1088_2057_1976_ac1c64
crossref_primary_10_1118_1_4939258
crossref_primary_10_1016_j_radphyschem_2019_04_028
crossref_primary_10_3390_diagnostics11050848
crossref_primary_10_1016_j_compmedimag_2021_101922
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.1118/1.4922680
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
Physics
EISSN 2473-4209
ExternalDocumentID 26133636
Genre Validation Studies
Evaluation Studies
Journal Article
Research Support, N.I.H., Extramural
GrantInformation_xml – fundername: NCI NIH HHS
  grantid: R01CA13687
GroupedDBID ---
--Z
-DZ
.GJ
0R~
1OB
1OC
29M
2WC
33P
36B
3O-
4.4
476
53G
5GY
5RE
5VS
AAHHS
AANLZ
AAQQT
AASGY
AAXRX
AAZKR
ABCUV
ABEFU
ABFTF
ABJNI
ABLJU
ABQWH
ABTAH
ABXGK
ACAHQ
ACBEA
ACCFJ
ACCZN
ACGFO
ACGFS
ACGOF
ACPOU
ACXBN
ACXQS
ADBBV
ADBTR
ADKYN
ADOZA
ADXAS
ADZMN
AEEZP
AEGXH
AEIGN
AENEX
AEQDE
AEUYR
AFBPY
AFFPM
AHBTC
AIACR
AIAGR
AITYG
AIURR
AIWBW
AJBDE
ALMA_UNASSIGNED_HOLDINGS
ALUQN
AMYDB
ASPBG
BFHJK
C45
CGR
CS3
CUY
CVF
DCZOG
DRFUL
DRMAN
DRSTM
DU5
EBD
EBS
ECM
EIF
EJD
EMB
EMOBN
F5P
G8K
HDBZQ
HGLYW
I-F
KBYEO
LATKE
LEEKS
LOXES
LUTES
LYRES
MEWTI
NPM
O9-
OVD
P2P
P2W
PALCI
PHY
RJQFR
RNS
ROL
SAMSI
SUPJJ
SV3
TEORI
TN5
TWZ
USG
WOHZO
WXSBR
XJT
ZGI
ZVN
ZXP
ZY4
ZZTAW
ID FETCH-LOGICAL-c4410-f45fc9a3b5f12608db25a6d5639ab88f0985ef78d00be229f9b02243b8978b422
IngestDate Sat Sep 28 08:07:06 EDT 2024
IsDoiOpenAccess false
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 7
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c4410-f45fc9a3b5f12608db25a6d5639ab88f0985ef78d00be229f9b02243b8978b422
OpenAccessLink https://escholarship.org/content/qt7mm622n3/qt7mm622n3.pdf?t=ov30tj
PMID 26133636
ParticipantIDs pubmed_primary_26133636
PublicationCentury 2000
PublicationDate July 2015
PublicationDateYYYYMMDD 2015-07-01
PublicationDate_xml – month: 07
  year: 2015
  text: July 2015
PublicationDecade 2010
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Medical physics (Lancaster)
PublicationTitleAlternate Med Phys
PublicationYear 2015
References 10619253 - Med Phys. 1999 Dec;26(12):2680-3
23927337 - Med Phys. 2013 Aug;40(8):081923
3203132 - Biometrics. 1988 Sep;44(3):837-45
24089917 - Med Phys. 2013 Oct;40(10):101915
17255409 - Radiology. 2007 Feb;242(2):388-95
26158045 - J Med Imaging (Bellingham). 2014 Oct;1(3):031003
14579853 - Phys Med Biol. 2003 Oct 7;48(19):R65-106
22149848 - Med Phys. 2011 Dec;38(12):6659-71
21325032 - Radiology. 2011 Apr;259(1):65-71
1946601 - Phys Med Biol. 1991 Sep;36(9):1165-82
16293877 - J Clin Oncol. 2005 Nov 20;23(33):8469-76
9356620 - Radiology. 1997 Nov;205(2):399-406
2845470 - Radiology. 1988 Nov;169(2):321-4
20384260 - Med Phys. 2010 Mar;37(3):1225-36
21361181 - Med Phys. 2011 Jan;38(1):114-24
11719660 - Radiology. 2001 Dec;221(3):657-67
17822008 - Med Phys. 2007 Jul;34(7):2995-3004
16696469 - Med Phys. 2006 Apr;33(4):933-40
15685718 - Stat Med. 2005 May 30;24(10):1579-607
15000608 - Med Phys. 2004 Feb;31(2):226-35
19610286 - Med Phys. 2009 Jun;36(6):1976-84
948604 - Radiology. 1976 Sep;120(3):691-4
18841852 - Med Phys. 2008 Sep;35(9):4012-8
23231276 - Med Phys. 2012 Dec;39(12):7254-61
7322043 - Med Phys. 1981 Mar-Apr;8(2):158-62
1873545 - Breast Cancer Res Treat. 1991 May;18 Suppl 1:S107-9
21656331 - Eur Radiol. 2012 Jan;22(1):1-8
11865363 - World J Surg. 2002 Mar;26(3):290-6
470842 - Med Phys. 1979 May-Jun;6(3):197-204
22380361 - Med Phys. 2012 Mar;39(3):1289-97
15248571 - Phys Med Biol. 2004 Jun 7;49(11):2183-95
25186390 - Med Phys. 2014 Sep;41(9):091903
21361191 - Med Phys. 2011 Jan;38(1):228-37
24399786 - CA Cancer J Clin. 2014 Jan-Feb;64(1):9-29
18195383 - Radiology. 2008 Mar;246(3):725-33
References_xml
SSID ssj0006350
Score 2.2406542
Snippet To investigate the feasibility of detecting breast microcalcification (μCa) with a dedicated breast computed tomography (CT) system based on energy-resolved...
SourceID pubmed
SourceType Index Database
StartPage 4401
SubjectTerms Area Under Curve
Breast
Calcinosis - diagnostic imaging
Calcium Carbonate
Computer Simulation
Humans
Mammography - instrumentation
Mammography - methods
Models, Biological
Phantoms, Imaging
Photons
Radiation Dosage
ROC Curve
Silicon
Software
Tomography, X-Ray Computed - instrumentation
Tomography, X-Ray Computed - methods
Title Microcalcification detectability using a bench-top prototype photon-counting breast CT based on a Si strip detector
URI https://www.ncbi.nlm.nih.gov/pubmed/26133636
Volume 42
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1db9MwFLU6EIgXBONjbID8wFvkkSZ2Yz9OBVSQOiGtk_Y22Y2jdogkYqlQ91P4tbvXdr1QBgJeoipWLMvn1L4-vh-EvMEtyhRSMK51ybi0c6aM1Qz2NmO0LWWlMN55ejyanPJPZ-JsMPjR81padeZwfnVrXMn_oArvAFeMkv0HZGOn8AJ-A77wBITh-VcYT9GbDibZ-dV5JEuLtwI--fY6WTklQCcGRr1gXdOiP1bXON21XTRYPjgWizDont4l41mCO1uJtwg6OVliNMmyDf023_rG7OaSx6sjTr7FkGrti31EhWG8cHLsZN2w6TJy8V0opjJZ6fpiFV_j_YdnUVCCbmTcj9-h86v1F-_cWwfRNigWQxG9W2HDcStbxouc8SxV_WWYZz26Fb01lXP_8S2LPQYwDA-5AhvS14Pqgd5-dajDCTHPRz7Jyp9bt_Jub5p2yE4hcQU9Rh0o7PFA5TTkqYJRvI1jwNzS4butc4qzV2aPyMNw0KBHnjWPycDWu-T-NLhS7JJ7nz1qT8jlrzSiP9GIOhpRTSONaKQR3aIR9TSi4xl1NKLQmaYnS-poRDc0ekpOP7yfjScs1OJgczCYU1ZxUc2Vzo2ohnAElqXJhB6VAgxcbaSsUiWFrQpZpqmxWaYqZdA6zI1UhTQ8y56RO3VT2z1CMyNMjgHTGkshWAt9YTi4FiUY71rZF-S5n7jz1idcOd9M6f5vWw7IgxumvSR3K_iH21dgLnbmtUPuGhXwbQM
link.rule.ids 783
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Microcalcification+detectability+using+a+bench-top+prototype+photon-counting+breast+CT+based+on+a+Si+strip+detector&rft.jtitle=Medical+physics+%28Lancaster%29&rft.au=Cho%2C+Hyo-Min&rft.au=Ding%2C+Huanjun&rft.au=Barber%2C+William+C&rft.au=Iwanczyk%2C+Jan+S&rft.date=2015-07-01&rft.eissn=2473-4209&rft.volume=42&rft.issue=7&rft.spage=4401&rft_id=info:doi/10.1118%2F1.4922680&rft_id=info%3Apmid%2F26133636&rft_id=info%3Apmid%2F26133636&rft.externalDocID=26133636