A semiautomated method for erythrocyte antigen typing on microtitration plates
We describe a method for erythrocyte antigen typing on U-bottom microtitration plates. This method permitted phenotyping of erythrocytes by an enzyme-enhanced hemagglutination assay simultaneously with an indirect antihuman globulin assay within the same microtitration plate. A robotic sample proces...
Saved in:
Published in | Vox sanguinis Vol. 63; no. 3; p. 215 |
---|---|
Main Authors | , |
Format | Journal Article |
Language | English |
Published |
England
01.01.1992
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Abstract | We describe a method for erythrocyte antigen typing on U-bottom microtitration plates. This method permitted phenotyping of erythrocytes by an enzyme-enhanced hemagglutination assay simultaneously with an indirect antihuman globulin assay within the same microtitration plate. A robotic sample processor identified the samples, prepared the red cell suspensions and distributed the suspension along with the diluted antisera onto the microtitration plates. The assay results were read and interpreted using a microtitration plate photometer controlled by software specially designed to interpret agglutination reactions. Sample identities and assay results were automatically connected by the computer system and transmitted to a minicomputer system. |
---|---|
AbstractList | We describe a method for erythrocyte antigen typing on U-bottom microtitration plates. This method permitted phenotyping of erythrocytes by an enzyme-enhanced hemagglutination assay simultaneously with an indirect antihuman globulin assay within the same microtitration plate. A robotic sample processor identified the samples, prepared the red cell suspensions and distributed the suspension along with the diluted antisera onto the microtitration plates. The assay results were read and interpreted using a microtitration plate photometer controlled by software specially designed to interpret agglutination reactions. Sample identities and assay results were automatically connected by the computer system and transmitted to a minicomputer system. |
Author | Pegert, S Sallander, S |
Author_xml | – sequence: 1 givenname: S surname: Sallander fullname: Sallander, S organization: Stockholm Blood Transfusion Service, Södersjukhuset, Sweden – sequence: 2 givenname: S surname: Pegert fullname: Pegert, S |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/1448965$$D View this record in MEDLINE/PubMed |
BookMark | eNotT0trwzAY86Gja7v9hIHZPdnnR-L4WMpeULbLdi5-fGldmrg4Liz_fhmrLkICCWlJZn3skZBHBiWb8HQsmeSiAPlnaM3LbKFiIMqfGVkASF5oAHVLlsNwBICGN9WczJmUja6rBflY0wG7YC45diajpx3mQ_S0jYliGvMhRTdmpKbPYY89zeM59Hsae9oFl2IOOZkcJnk-TfHhjty05jTg_ZVX5Pvl-WvzVmw_X983623hpFCi8BqRMz_thcoKZ-umrmupQLYOhUPVMOMb1XoB2lvJubPaaKu08wBeCc5X5OG_93yxHfrdOYXOpHF3_cV_ASMhU10 |
CitedBy_id | crossref_primary_10_1046_j_1537_2995_2001_41101263_x crossref_primary_10_1111_j_1423_0410_1995_tb02540_x crossref_primary_10_1046_j_1423_0410_1998_7410036_x crossref_primary_10_21307_immunohematology_2019_649 |
ContentType | Journal Article |
DBID | CGR CUY CVF ECM EIF NPM |
DOI | 10.1111/j.1423-0410.1992.tb05103.x |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
Discipline | Medicine |
ExternalDocumentID | 1448965 |
Genre | Journal Article |
GroupedDBID | --- .3N .55 .GA .GJ .Y3 05W 0R~ 0~B 10A 123 1OB 1OC 29R 30W 31~ 33P 36B 3SF 4.4 50Y 50Z 51W 51X 52M 52N 52O 52P 52R 52S 52T 52U 52V 52W 52X 53G 5HH 5LA 5RE 5VS 66C 702 7PT 8-0 8-1 8-3 8-4 8-5 8UI 8UM 930 A01 A03 AAESR AAEVG AAHHS AANLZ AAONW AASGY AAXRX AAYIC AAZKR ABCQN ABCUV ABDBF ABEML ABJNI ABLJU ABPVW ABQWH ABXGK ACAHQ ACBWZ ACCFJ ACCZN ACGFS ACGOF ACMXC ACPOU ACPRK ACSCC ACXBN ACXQS ADBBV ADBTR ADEOM ADIZJ ADKYN ADMGS ADOZA ADXAS ADZMN AEEZP AEIGN AEIMD AENEX AEQDE AEUQT AEUYR AFBPY AFEBI AFFNX AFFPM AFGKR AFPWT AFRAH AFZJQ AHBTC AHEFC AHMBA AIACR AITYG AIURR AIWBW AJBDE ALAGY ALMA_UNASSIGNED_HOLDINGS ALUQN AMBMR AMYDB ASPBG ATUGU AVWKF AZBYB AZFZN AZVAB BAFTC BDRZF BFHJK BHBCM BMXJE BROTX BRXPI BY8 C45 CAG CGR COF CS3 CUY CVF CYUIP D-6 D-7 D-E D-F DCZOG DPXWK DR2 DRFUL DRMAN DRSTM DU5 E0A EAD EAP EBC EBD EBS ECM EGARE EIF EJD EMB EMK EMOBN ESX EX3 F00 F5P FB. FEDTE FUBAC FZ0 G-S G.N GODZA H.X HF~ HGLYW HVGLF HZI HZ~ IHE IX1 J0M J5H K48 KBYEO L7B LATKE LC2 LC3 LEEKS LH4 LITHE LOXES LP6 LP7 LUTES LW6 LYRES MEWTI MK4 MRFUL MRMAN MRSTM MSFUL MSMAN MSSTM MXFUL MXMAN MXSTM N04 N05 N9A NF~ NPM O1H O66 O9- OIG OVD P2W P2X P2Z P4B P4D PALCI PQQKQ Q.N Q11 QB0 R.K RIG RIWAO RJQFR RKO ROL RX1 SAMSI SUPJJ SV3 TEORI TUS UB1 UJ6 W8V W99 WBKPD WHWMO WIH WIJ WIK WOHZO WOW WQJ WUP WVDHM WXI WXSBR X7M XG1 YFH ZGI ZXP ZZTAW ~IA ~WT |
ID | FETCH-LOGICAL-c4373-d9ee21d19905b3cb686664704fce3ce781ad87fd309db422cb9a9b79cd00d7322 |
ISSN | 0042-9007 |
IngestDate | Sat Sep 28 08:39:05 EDT 2024 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 3 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c4373-d9ee21d19905b3cb686664704fce3ce781ad87fd309db422cb9a9b79cd00d7322 |
PMID | 1448965 |
ParticipantIDs | pubmed_primary_1448965 |
PublicationCentury | 1900 |
PublicationDate | 1992-01-01 |
PublicationDateYYYYMMDD | 1992-01-01 |
PublicationDate_xml | – month: 01 year: 1992 text: 1992-01-01 day: 01 |
PublicationDecade | 1990 |
PublicationPlace | England |
PublicationPlace_xml | – name: England |
PublicationTitle | Vox sanguinis |
PublicationTitleAlternate | Vox Sang |
PublicationYear | 1992 |
SSID | ssj0008285 |
Score | 1.4114783 |
Snippet | We describe a method for erythrocyte antigen typing on U-bottom microtitration plates. This method permitted phenotyping of erythrocytes by an enzyme-enhanced... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 215 |
SubjectTerms | Automation Blood Grouping and Crossmatching Coombs Test Erythrocytes - immunology Humans Papain Phenotype Rh-Hr Blood-Group System - immunology Titrimetry |
Title | A semiautomated method for erythrocyte antigen typing on microtitration plates |
URI | https://www.ncbi.nlm.nih.gov/pubmed/1448965 |
Volume | 63 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnZ1ZS8NAEMcXDxRfxBNv9sG3srK5s49FFBEsgge-SfaICDYtNoL66Z3JTg-L4vESShZCml87OzOZ-Q9jh2WKqlNRIkplEwE7VCiKzEgRONjdbWrTqGiqLTrp2U18fpfcDWe4U3dJrY_M-5d9Jf-hCueAK3bJ_oHs6KJwAj4DXzgCYTj-inG7NXDdx-Kl7oHfCZ6jHwftVbyf33ACgnmr8f1AjZqbmG5tapyrVhfL8OAahL__hB7npJ9623ttDTCVScojPguDSffKTo3qunQP1PdzNU4h-HLTUQqBzGIcCiX9-NmhWSS78zgZNZONS36wvWEkZOw7IUNMPaNqn6_KnIDS7zZUIKDLVZr8uDilik0rs2w2y9G8dTBJQxswivINO4_wW5HWLBVwfXN3S2yBrjkVYDSOxvUKW6YIgbc97lU246o1tnhBNRDrrNPmn6hzT50DdT5BnRN17qnzXsU_U-ee-ga7OT25Pj4TNBVDGJShElY5FwYW7l4mOjI6zSECjTMZl8ZFxmV5UNg8K20kldVxGBqtCqUzZayUNgP7vcnmql7lthgPFBb5Kg27XhmbONPSlUqGxgVg-CFU3Wab_knc9730yT09op3vFnbZ0vgHtsfmS_inuX1w22p90ED6AL6zPmc |
link.rule.ids | 783 |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=A+semiautomated+method+for+erythrocyte+antigen+typing+on+microtitration+plates&rft.jtitle=Vox+sanguinis&rft.au=Sallander%2C+S&rft.au=Pegert%2C+S&rft.date=1992-01-01&rft.issn=0042-9007&rft.volume=63&rft.issue=3&rft.spage=215&rft_id=info:doi/10.1111%2Fj.1423-0410.1992.tb05103.x&rft_id=info%3Apmid%2F1448965&rft_id=info%3Apmid%2F1448965&rft.externalDocID=1448965 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0042-9007&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0042-9007&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0042-9007&client=summon |