A two‐center study for the quality control of [18F]FDG using FASTlab phosphate cassettes

Objective The GE FASTlab radiosynthesis module is routinely used for the production of [ 18 F]FDG, utilizing the commercially available phosphate cassettes. Because of the observation of a white precipitate in the product vial before the product expiry time, we re-examined the quality of the produce...

Full description

Saved in:
Bibliographic Details
Published inAnnals of nuclear medicine Vol. 30; no. 8; pp. 563 - 571
Main Authors Huang, Ya-Yao, Taylor, Stephen, Koziorowski, Jacek, Chang, Yu-Ning, Kao, Wei-Hua, Tzen, Kai-Yuan, Shiue, Chyng-Yann
Format Journal Article
LanguageEnglish
Published Tokyo Springer Japan 01.10.2016
Springer Nature B.V
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objective The GE FASTlab radiosynthesis module is routinely used for the production of [ 18 F]FDG, utilizing the commercially available phosphate cassettes. Because of the observation of a white precipitate in the product vial before the product expiry time, we re-examined the quality of the produced [ 18 F]FDG solution. Methods Phosphate buffered [ 18 F]FDG solution was synthesized on the FASTlab and analyzed at both National Taiwan University Hospital (NTUH) of Taiwan and Royal Brisbane and Women’s Hospital (RBWH) of Australia. In addition to the standard product quality control (QC), the concentration of aluminum (Al 3+ ) as probable cause of the precipitations in the [ 18 F]FDG solution was analyzed by inductively coupled plasma mass spectrometry (ICP-MS at RBWH) and inductively coupled plasma optical emission spectrometry (ICP-OES at NTUH), and using three semi-quantitative methods at NTUH, Advantec ® Alumi Check Test Strip, Quantofix ® Aluminum Test Strip and MColortest™ Aluminum Test kit. Results The precipitates were observed in the [ 18 F]FDG solution within 24 (NTUH) and 6 (RBWH) hours after the end of synthesis in 38–100 % of the batches, dependent on the batch of the FASTlab cassettes. Addition of metal-free HCl (aq) to aliquots of [ 18 F]FDG containing precipitate, followed by ICP-MS analysis revealed Al 3+ concentrations of 70–80 ppm. Al 3+ concentrations of 10–12 ppm were detected in [ 18 F]FDG batches that did not show any precipitation. In contrast, less than 5 ppm of the residual Al 3+ was detected by semi-quantitative methods in all batches. Conclusion The US (USP), British (BP), European (EP) and Japanese (JP) pharmacopeias demand that [ 18 F]FDG for injection should be clear and particulate free within the given shelf-life/expiration time. To avoid Al-phosphate precipitation within the product expiry time, FASTlab citrate cassettes, rather than phosphate cassettes, should be used for [ 18 F]FDG production. Although testing for Al 3+ is not listed in the [ 18 F]FDG monographs of the USP, BP and EP, residual Al 3+ levels should be considered in the interests of patient safety.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0914-7187
1864-6433
1864-6433
DOI:10.1007/s12149-016-1097-4