Quality of life and handling experience with the PROSE device: an Indian scenario

PROSE (prosthetic replacement of ocular surface ecosystem) device is a custom-designed, corneal vaulting scleral contact lens, which is used in the treatment of irregular corneal conditions to improve vision and comfort. The present study aimed at assessing the success of the device in an Indian sce...

Full description

Saved in:
Bibliographic Details
Published inClinical and experimental optometry Vol. 100; no. 6; pp. 710 - 717
Main Authors Bhattacharya, Pradipta, Mahadevan, Rajeswari
Format Journal Article
LanguageEnglish
Published Melbourne Taylor & Francis 01.11.2017
Wiley Publishing Asia Pty Ltd
Taylor & Francis Ltd
Subjects
Online AccessGet full text

Cover

Loading…
Abstract PROSE (prosthetic replacement of ocular surface ecosystem) device is a custom-designed, corneal vaulting scleral contact lens, which is used in the treatment of irregular corneal conditions to improve vision and comfort. The present study aimed at assessing the success of the device in an Indian scenario in terms of change in quality of life and to understand the handling issues related to the device use. Thirty-two subjects with various irregular corneal conditions meeting the inclusion criteria were included in the study. Subjects were followed for three months after dispensing the PROSE device. Subjects' demographic details, high and low contrast visual acuity with habitual correction and PROSE device, Visual Function Questionnaire scores (NEI VFQ-25) and Ocular Surface Disease Index (OSDI) scores pre- and post- PROSE treatment were collected and compared. An indigenously developed questionnaire was also administered during the follow-up visit for assessing the handling-related issues faced by the subjects while using the device. Forty eyes of 32 subjects were included in the study, of whom 30 reported for follow-up. The median NEI VFQ-25 score improved from 47.33 points to 77.27 points over a period of three months, which was statistically significant (p < 0.05). There was a statistically significant decrease in median OSDI score from 51.14 points to 13.63 points post-PROSE treatment (p < 0.05). Subjects reported no or very minimal handling-related difficulties associated with the use of the PROSE device. The PROSE treatment can be an effective mode of managing patients with irregular corneal conditions and significantly improved the vision-related quality of life of patients suffering from these conditions. The handling of the device is easy and can be mastered with adequate training.
AbstractList Background PROSE (prosthetic replacement of ocular surface ecosystem) device is a custom-designed, corneal vaulting scleral contact lens, which is used in the treatment of irregular corneal conditions to improve vision and comfort. The present study aimed at assessing the success of the PROSE device in an Indian scenario in terms of change in quality of life and to understand the handling issues related to the device use. Methods Thirty-two subjects with various irregular corneal conditions meeting the inclusion criteria were included in the study. Subjects were followed for three months after dispensing the PROSE device. Subjects' demographic details, high and low contrast visual acuity with habitual correction and PROSE device, Visual Function Questionnaire scores (NEI VFQ-25) and Ocular Surface Disease Index (OSDI) scores pre- and post-PROSE treatment were collected and compared. An indigenously developed questionnaire was also administered during the follow-up visit for assessing the handling-related issues faced by the subjects while using the device. Results Forty eyes of 32 subjects were included in the study, of whom 30 reported for follow-up. The median NEI VFQ-25 score improved from 47.33 points to 77.27 points over a period of three months, which was statistically significant (p<0.05). There was a statistically significant decrease in median OSDI score from 51.14 points to 13.63 points post-PROSE treatment (p<0.05). Subjects reported no or very minimal handling-related difficulties associated with the use of the PROSE device. Conclusion The PROSE treatment can be an effective mode of managing patients with irregular corneal conditions and significantly improved the vision-related quality of life of patients suffering from these conditions. The handling of the device is easy and can be mastered with adequate training.
PROSE (prosthetic replacement of ocular surface ecosystem) device is a custom-designed, corneal vaulting scleral contact lens, which is used in the treatment of irregular corneal conditions to improve vision and comfort. The present study aimed at assessing the success of the PROSE device in an Indian scenario in terms of change in quality of life and to understand the handling issues related to the device use. Thirty-two subjects with various irregular corneal conditions meeting the inclusion criteria were included in the study. Subjects were followed for three months after dispensing the PROSE device. Subjects' demographic details, high and low contrast visual acuity with habitual correction and PROSE device, Visual Function Questionnaire scores (NEI VFQ-25) and Ocular Surface Disease Index (OSDI) scores pre- and post-PROSE treatment were collected and compared. An indigenously developed questionnaire was also administered during the follow-up visit for assessing the handling-related issues faced by the subjects while using the device. Forty eyes of 32 subjects were included in the study, of whom 30 reported for follow-up. The median NEI VFQ-25 score improved from 47.33 points to 77.27 points over a period of three months, which was statistically significant (p < 0.05). There was a statistically significant decrease in median OSDI score from 51.14 points to 13.63 points post-PROSE treatment (p < 0.05). Subjects reported no or very minimal handling-related difficulties associated with the use of the PROSE device. The PROSE treatment can be an effective mode of managing patients with irregular corneal conditions and significantly improved the vision-related quality of life of patients suffering from these conditions. The handling of the device is easy and can be mastered with adequate training.
PROSE (prosthetic replacement of ocular surface ecosystem) device is a custom-designed, corneal vaulting scleral contact lens, which is used in the treatment of irregular corneal conditions to improve vision and comfort. The present study aimed at assessing the success of the device in an Indian scenario in terms of change in quality of life and to understand the handling issues related to the device use. Thirty-two subjects with various irregular corneal conditions meeting the inclusion criteria were included in the study. Subjects were followed for three months after dispensing the PROSE device. Subjects' demographic details, high and low contrast visual acuity with habitual correction and PROSE device, Visual Function Questionnaire scores (NEI VFQ-25) and Ocular Surface Disease Index (OSDI) scores pre- and post- PROSE treatment were collected and compared. An indigenously developed questionnaire was also administered during the follow-up visit for assessing the handling-related issues faced by the subjects while using the device. Forty eyes of 32 subjects were included in the study, of whom 30 reported for follow-up. The median NEI VFQ-25 score improved from 47.33 points to 77.27 points over a period of three months, which was statistically significant (p < 0.05). There was a statistically significant decrease in median OSDI score from 51.14 points to 13.63 points post-PROSE treatment (p < 0.05). Subjects reported no or very minimal handling-related difficulties associated with the use of the PROSE device. The PROSE treatment can be an effective mode of managing patients with irregular corneal conditions and significantly improved the vision-related quality of life of patients suffering from these conditions. The handling of the device is easy and can be mastered with adequate training.
PROSE (prosthetic replacement of ocular surface ecosystem) device is a custom-designed, corneal vaulting scleral contact lens, which is used in the treatment of irregular corneal conditions to improve vision and comfort. The present study aimed at assessing the success of the PROSE device in an Indian scenario in terms of change in quality of life and to understand the handling issues related to the device use.BACKGROUNDPROSE (prosthetic replacement of ocular surface ecosystem) device is a custom-designed, corneal vaulting scleral contact lens, which is used in the treatment of irregular corneal conditions to improve vision and comfort. The present study aimed at assessing the success of the PROSE device in an Indian scenario in terms of change in quality of life and to understand the handling issues related to the device use.Thirty-two subjects with various irregular corneal conditions meeting the inclusion criteria were included in the study. Subjects were followed for three months after dispensing the PROSE device. Subjects' demographic details, high and low contrast visual acuity with habitual correction and PROSE device, Visual Function Questionnaire scores (NEI VFQ-25) and Ocular Surface Disease Index (OSDI) scores pre- and post-PROSE treatment were collected and compared. An indigenously developed questionnaire was also administered during the follow-up visit for assessing the handling-related issues faced by the subjects while using the device.METHODSThirty-two subjects with various irregular corneal conditions meeting the inclusion criteria were included in the study. Subjects were followed for three months after dispensing the PROSE device. Subjects' demographic details, high and low contrast visual acuity with habitual correction and PROSE device, Visual Function Questionnaire scores (NEI VFQ-25) and Ocular Surface Disease Index (OSDI) scores pre- and post-PROSE treatment were collected and compared. An indigenously developed questionnaire was also administered during the follow-up visit for assessing the handling-related issues faced by the subjects while using the device.Forty eyes of 32 subjects were included in the study, of whom 30 reported for follow-up. The median NEI VFQ-25 score improved from 47.33 points to 77.27 points over a period of three months, which was statistically significant (p < 0.05). There was a statistically significant decrease in median OSDI score from 51.14 points to 13.63 points post-PROSE treatment (p < 0.05). Subjects reported no or very minimal handling-related difficulties associated with the use of the PROSE device.RESULTSForty eyes of 32 subjects were included in the study, of whom 30 reported for follow-up. The median NEI VFQ-25 score improved from 47.33 points to 77.27 points over a period of three months, which was statistically significant (p < 0.05). There was a statistically significant decrease in median OSDI score from 51.14 points to 13.63 points post-PROSE treatment (p < 0.05). Subjects reported no or very minimal handling-related difficulties associated with the use of the PROSE device.The PROSE treatment can be an effective mode of managing patients with irregular corneal conditions and significantly improved the vision-related quality of life of patients suffering from these conditions. The handling of the device is easy and can be mastered with adequate training.CONCLUSIONThe PROSE treatment can be an effective mode of managing patients with irregular corneal conditions and significantly improved the vision-related quality of life of patients suffering from these conditions. The handling of the device is easy and can be mastered with adequate training.
Background PROSE (prosthetic replacement of ocular surface ecosystem) device is a custom‐designed, corneal vaulting scleral contact lens, which is used in the treatment of irregular corneal conditions to improve vision and comfort. The present study aimed at assessing the success of the PROSE device in an Indian scenario in terms of change in quality of life and to understand the handling issues related to the device use. Methods Thirty‐two subjects with various irregular corneal conditions meeting the inclusion criteria were included in the study. Subjects were followed for three months after dispensing the PROSE device. Subjects’ demographic details, high and low contrast visual acuity with habitual correction and PROSE device, Visual Function Questionnaire scores (NEI VFQ‐25) and Ocular Surface Disease Index (OSDI) scores pre‐ and post‐PROSE treatment were collected and compared. An indigenously developed questionnaire was also administered during the follow‐up visit for assessing the handling‐related issues faced by the subjects while using the device. Results Forty eyes of 32 subjects were included in the study, of whom 30 reported for follow‐up. The median NEI VFQ‐25 score improved from 47.33 points to 77.27 points over a period of three months, which was statistically significant (p < 0.05). There was a statistically significant decrease in median OSDI score from 51.14 points to 13.63 points post‐PROSE treatment (p < 0.05). Subjects reported no or very minimal handling‐related difficulties associated with the use of the PROSE device. Conclusion The PROSE treatment can be an effective mode of managing patients with irregular corneal conditions and significantly improved the vision‐related quality of life of patients suffering from these conditions. The handling of the device is easy and can be mastered with adequate training.
Author Bhattacharya, Pradipta
Mahadevan, Rajeswari
Author_xml – sequence: 1
  givenname: Pradipta
  surname: Bhattacharya
  fullname: Bhattacharya, Pradipta
  organization: Elite School of Optometry, Sankara Nethralaya, Medical Research Foundation
– sequence: 2
  givenname: Rajeswari
  surname: Mahadevan
  fullname: Mahadevan, Rajeswari
  organization: Elite School of Optometry, Sankara Nethralaya, Medical Research Foundation
BackLink https://www.ncbi.nlm.nih.gov/pubmed/28295635$$D View this record in MEDLINE/PubMed
BookMark eNp9kU1PHDEMhqMKVBbaQ_9AFakXehhIMplM0lu1ohQJaUs_pN6iTMbpBmWTbWaGZf89oQscqFof7IOf17b8HqK9mCIg9IaSE1ri1N6mE8oaql6gGeWcV0TVcg_NiKSi4oKxA3Q4DNeEMF4r_hIdMMlUI-pmhq6uJhP8uMXJ4eAdYBN7vCwp-PgLw-0asodoAW_8uMTjEvCXr4tvZ7iHG2_hQ8HxRex9KYOFaLJPr9C-M2GA1w_1CP34dPZ9_rm6XJxfzD9eVpbXtap434muEZx0bS-5lOBEK4mixDheQ9-5VjkDorSVFUSS1haFIsBFZ0Xb8foIHe_mrnP6PcEw6pUvN4RgIqRp0FS2rWyatrlH3z1Dr9OUY7lOUyUY4YwRWqi3D9TUraDX6-xXJm_147MK8H4H2JyGIYN7QijR90boYoT-Y0RhT5-x1o9m9CmO2fjwP8XGB9j-e7Se_1w8KvhO4aNLeWU2KYdej2YbUnbZROsHXf-96A7BnKlD
CitedBy_id crossref_primary_10_1016_j_jcjo_2021_09_004
crossref_primary_10_3233_THC_231983
crossref_primary_10_1016_j_clae_2018_10_024
crossref_primary_10_3390_jpm14101051
crossref_primary_10_2147_OPTO_S284632
crossref_primary_10_1097_ICL_0000000000000792
crossref_primary_10_1016_j_clae_2025_102385
crossref_primary_10_1097_OPX_0000000000001905
crossref_primary_10_1136_bjophthalmol_2019_315231
crossref_primary_10_1016_j_ajoc_2023_101919
crossref_primary_10_1016_j_clae_2018_10_020
crossref_primary_10_2147_OPTO_S337920
Cites_doi 10.4103/0301-4738.81994
10.4103/0974-9233.134675
10.1016/j.clae.2012.04.003
10.1016/j.clae.2012.03.001
10.1136/bjo.87.8.941
10.1097/OPX.0b013e31827cd8be
10.1016/j.clae.2013.11.001
10.1016/j.ophtha.2004.06.036
10.1097/01.ICL.0000152492.98553.8D
10.1001/archopht.119.7.1050
10.1001/archopht.118.5.615
10.1179/136485910X12647085215859
10.1136/bjo.71.10.791
10.1016/j.clae.2013.02.004
10.1136/bjophthalmol-2011-300539
10.1136/bjo.84.9.1035
10.1016/j.ajo.2009.07.037
10.1097/ICL.0000000000000006
10.1097/ICO.0000000000000408
ContentType Journal Article
Copyright 2017 Optometry Australia 2017
2017 Optometry Australia
2017 Optometry Australia.
Copyright_xml – notice: 2017 Optometry Australia 2017
– notice: 2017 Optometry Australia
– notice: 2017 Optometry Australia.
DBID AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
7TK
NAPCQ
7X8
DOI 10.1111/cxo.12519
DatabaseName CrossRef
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
Neurosciences Abstracts
Nursing & Allied Health Premium
MEDLINE - Academic
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
Nursing & Allied Health Premium
Neurosciences Abstracts
MEDLINE - Academic
DatabaseTitleList Nursing & Allied Health Premium
MEDLINE

MEDLINE - Academic

Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1444-0938
EndPage 717
ExternalDocumentID 28295635
10_1111_cxo_12519
CXO12519
12124224
Genre Original Article
article
Journal Article
Comparative Study
GroupedDBID ---
.3N
.GA
05W
0BK
0R~
10A
1OB
1OC
24P
29B
33P
36B
3SF
4.4
50Y
50Z
51W
51X
52M
52N
52O
52P
52R
52S
52T
52U
52V
52W
52X
53G
5GY
5HH
5LA
5VS
66C
6J9
6PF
702
7PT
8-0
8-1
8-3
8-4
8-5
8UM
930
A01
A03
AABVL
AAESR
AAEVG
AAMIU
AAONW
AAPUL
AAQRR
AAWTL
AAZKR
ABBKH
ABCQN
ABCUV
ABJNI
ABLIJ
ABPVW
ABXYU
ACENM
ACGFO
ACGFS
ACIEZ
ACMXC
ACNCT
ACPOU
ACPRK
ACXQS
ADBBV
ADEOM
ADIZJ
ADKYN
ADMGS
ADXAS
ADZMN
AEIMD
AENEX
AEUQT
AFBPY
AFGKR
AFPWT
AGFJD
AGRBW
AGYJP
AIAGR
AIRBT
AIURR
AJAOE
AKBVH
ALAGY
ALMA_UNASSIGNED_HOLDINGS
ALYBC
AMBMR
AMDAE
AMYDB
ATUGU
AZBYB
AZVAB
BAFTC
BAWUL
BHBCM
BMXJE
BROTX
BRXPI
BY8
CS3
D-6
D-7
D-E
D-F
DCZOG
DIK
DPXWK
DR2
DRFUL
DRMAN
DRSTM
DU5
E3Z
EBS
EJD
EMB
F00
F01
F04
F5P
FUBAC
G-S
G.N
GODZA
H.X
H13
HZI
HZ~
IX1
J0M
K48
LATKE
LC2
LC3
LH4
LITHE
LOXES
LP6
LP7
LUTES
LW6
LYRES
M4Z
MK4
MRFUL
MRMAN
MRSTM
MSFUL
MSMAN
MSSTM
MXFUL
MXMAN
MXSTM
N04
N05
N9A
NF~
O66
OIG
OK1
OVD
P2P
P2W
P2X
P2Z
P4B
P4D
PQQKQ
Q.N
Q11
QB0
R.K
RNANH
ROL
RVRKI
RX1
SUPJJ
SV3
TBQAZ
TDBHL
TEORI
TERGH
TFL
TR2
TUROJ
UB1
UEQFS
V8K
W8V
W99
WBKPD
WHWMO
WIH
WIJ
WIK
WIN
WOHZO
WQJ
WRC
WUP
WVDHM
WXI
XG1
XSB
ZZTAW
~IA
~WT
.Y3
2WC
31~
AAGDL
AAJKZ
AAMMB
AANHP
AAORF
ABEML
ABWCV
ABWVI
ACBWZ
ACKZS
ACOPL
ACRPL
ACSCC
ACYXJ
ACYZI
ADFOM
ADNMO
AEFGJ
AEIIZ
AFLEI
AFRVT
AFZJQ
AGDLA
AGQPQ
AGXDD
AHEFC
AIDQK
AIDYY
AJVHN
ALQZU
ASPBG
AVWKF
AZFZN
BDRZF
C1A
CAG
COF
FEDTE
HF~
HVGLF
KTM
NUSFT
PALCI
RIWAO
RJQFR
TASJS
WOQ
AAYXX
ADYSH
AMPGV
CITATION
AAHHS
ACCFJ
ADZOD
AEEZP
AEQDE
AIWBW
AJBDE
CGR
CUY
CVF
ECM
EIF
NPM
7TK
NAPCQ
7X8
ID FETCH-LOGICAL-c4339-4db6b5640b7d8488ef6780910af43edbf79fae60b79c60807c4db90e46bc67b43
IEDL.DBID DR2
ISSN 0816-4622
1444-0938
IngestDate Mon Jul 21 11:05:28 EDT 2025
Mon Jul 14 10:28:07 EDT 2025
Thu Apr 03 06:41:48 EDT 2025
Tue Jul 01 02:59:18 EDT 2025
Thu Apr 24 22:57:10 EDT 2025
Wed Aug 20 07:26:32 EDT 2025
Wed Dec 25 09:08:22 EST 2024
IsDoiOpenAccess false
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 6
Keywords scleral contact lens
quality of life
PROSE device
handling of PROSE device
irregular cornea
Language English
License 2017 Optometry Australia.
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c4339-4db6b5640b7d8488ef6780910af43edbf79fae60b79c60807c4db90e46bc67b43
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Article-2
ObjectType-Feature-1
content type line 23
OpenAccessLink https://onlinelibrary.wiley.com/doi/pdfdirect/10.1111/cxo.12519
PMID 28295635
PQID 1962042201
PQPubID 2045178
PageCount 8
ParticipantIDs crossref_primary_10_1111_cxo_12519
informaworld_taylorfrancis_310_1111_cxo_12519
proquest_miscellaneous_1877855754
crossref_citationtrail_10_1111_cxo_12519
proquest_journals_1962042201
pubmed_primary_28295635
wiley_primary_10_1111_cxo_12519_CXO12519
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 11/1/2017
November 2017
2017-11-01
2017-Nov
20171101
PublicationDateYYYYMMDD 2017-11-01
PublicationDate_xml – month: 11
  year: 2017
  text: 11/1/2017
  day: 01
PublicationDecade 2010
PublicationPlace Melbourne
PublicationPlace_xml – name: Melbourne
– name: Australia
– name: Chichester
PublicationTitle Clinical and experimental optometry
PublicationTitleAlternate Clin Exp Optom
PublicationYear 2017
Publisher Taylor & Francis
Wiley Publishing Asia Pty Ltd
Taylor & Francis Ltd
Publisher_xml – name: Taylor & Francis
– name: Wiley Publishing Asia Pty Ltd
– name: Taylor & Francis Ltd
References 2015; 34
2013; 36
1987; 71
2000
2010; 149
2005; 112
2000; 118
2010; 104
2000; 84
2013; 90
2014; 37
2006; 5
2005; 31
2011; 59
2001; 119
2012; 35
2014; 40
2003; 87
2012; 96
2001; 42
2014; 21
CIT0010
CIT0001
CIT0012
Dandona L (CIT0002) 2001; 42
CIT0011
Rathi VM (CIT0016) 2011; 59
CIT0022
Rosenthal P (CIT0003) 2006; 5
Rathi VM (CIT0021) 2012; 35
CIT0014
CIT0013
CIT0005
CIT0004
CIT0015
CIT0007
CIT0018
CIT0006
CIT0017
Wolffsohn JS (CIT0008) 2000; 84
CIT0009
CIT0019
Efron N (CIT0020) 2013; 90
References_xml – volume: 87
  start-page: 941
  year: 2003
  end-page: 945
  article-title: Causes and temporal trends of blindness and severe visual impairment in children in schools for the blind in North India
  publication-title: Br J Ophthalmol
– volume: 40
  start-page: 71
  year: 2014
  end-page: 73
  article-title: PROSE for irregular corneas at a tertiary eye care center
  publication-title: Eye Contact Lens
– volume: 31
  start-page: 130
  year: 2005
  end-page: 134
  article-title: Fluid‐ventilated, gas‐permeable scleral contact lens is an effective option for managing severe ocular surface disease and many corneal disorders that would otherwise require penetrating keratoplasty
  publication-title: Eye Contact Lens
– volume: 37
  start-page: 196
  year: 2014
  end-page: 202
  article-title: Scleral contact lenses for visual rehabilitation after penetrating keratoplasty: Long term outcomes
  publication-title: Cont Lens Anterior Eye
– volume: 112
  start-page: 152
  year: 2005
  end-page: 158
  article-title: Vision‐related quality of life in patients with bilateral severe age‐related macular degeneration
  publication-title: Ophthalmology
– year: 2000
– volume: 119
  start-page: 1050
  year: 2001
  end-page: 1058
  article-title: Development of the 25‐list‐item National Eye Institute visual function questionnaire
  publication-title: Arch Ophthalmol
– volume: 34
  start-page: 359
  year: 2015
  end-page: 369
  article-title: Global consensus on keratoconus and ectatic diseases
  publication-title: Cornea
– volume: 35
  start-page: 222
  year: 2012
  end-page: 227
  article-title: PROSE treatment of corneal ectasia
  publication-title: Cont Lens Anterior Eye
– volume: 21
  start-page: 225
  year: 2014
  article-title: Quality of life in non‐infectious uveitis patients on immunosuppressive therapy
  publication-title: Middle East Afr J Ophthalmol
– volume: 59
  start-page: 279
  year: 2011
  article-title: Boston ocular surface prosthesis: An Indian experience
  publication-title: Indian J Ophthalmol
– volume: 71
  start-page: 791
  year: 1987
  end-page: 796
  article-title: Contrast sensitivity, acuity, and the perception of 'real‐world' targets
  publication-title: Br J Ophthalmol
– volume: 35
  start-page: 189
  year: 2012
  end-page: 192
  article-title: Fluid filled scleral contact lens in pediatric patients: challenges and outcome
  publication-title: Cont Lens Anterior Eye
– volume: 5
  start-page: 1
  year: 2006
  end-page: 7
  article-title: Fluid‐ventilated gas permeable scleral lens: a new paradigm for the management of irregular corneal astigmatism and severe ocular surface disease
  publication-title: J Contemp Ophthalmol
– volume: 36
  start-page: 159
  year: 2013
  end-page: 163
  article-title: Patient ocular conditions and clinical outcomes using a PROSE scleral device
  publication-title: Cont Lens Anterior Eye
– volume: 118
  start-page: 615
  year: 2000
  end-page: 621
  article-title: Reliability and validity of the ocular surface disease index
  publication-title: Arch Ophthalmol
– volume: 149
  start-page: 54
  year: 2010
  end-page: 61
  article-title: Clinical benefits of the Boston ocular surface prosthesis
  publication-title: Am J Ophthalmol
– volume: 84
  start-page: 1035
  year: 2000
  end-page: 1040
  article-title: Implementation methods for vision related quality of life questionnaires
  publication-title: Br J Ophthalmol
– volume: 104
  start-page: 247
  year: 2010
  end-page: 255
  article-title: Estimating the prevalence of dry eye among Indian patients attending a tertiary ophthalmology clinic
  publication-title: Ann Trop Med Parasitol
– volume: 96
  start-page: 614
  year: 2012
  end-page: 618
  article-title: Global estimates of visual impairment: 2010
  publication-title: Br J Ophthalmol
– volume: 42
  start-page: 908
  year: 2001
  end-page: 916
  article-title: Blindness in the Indian state of Andhra Pradesh
  publication-title: Invest Ophthalmol Vis Sci
– volume: 90
  start-page: 113
  year: 2013
  end-page: 118
  article-title: International survey of rigid contact lens fitting
  publication-title: Optom Vis Sci
– volume: 59
  start-page: 279
  year: 2011
  ident: CIT0016
  publication-title: Indian J Ophthalmol
  doi: 10.4103/0301-4738.81994
– ident: CIT0012
  doi: 10.4103/0974-9233.134675
– ident: CIT0009
  doi: 10.1016/j.clae.2012.04.003
– volume: 35
  start-page: 189
  year: 2012
  ident: CIT0021
  publication-title: Cont Lens Anterior Eye
  doi: 10.1016/j.clae.2012.03.001
– ident: CIT0004
  doi: 10.1136/bjo.87.8.941
– volume: 90
  start-page: 113
  year: 2013
  ident: CIT0020
  publication-title: Optom Vis Sci
  doi: 10.1097/OPX.0b013e31827cd8be
– ident: CIT0022
  doi: 10.1016/j.clae.2013.11.001
– ident: CIT0007
  doi: 10.1016/j.ophtha.2004.06.036
– ident: CIT0019
  doi: 10.1097/01.ICL.0000152492.98553.8D
– ident: CIT0010
– volume: 5
  start-page: 1
  year: 2006
  ident: CIT0003
  publication-title: J Contemp Ophthalmol
– volume: 42
  start-page: 908
  year: 2001
  ident: CIT0002
  publication-title: Invest Ophthalmol Vis Sci
– ident: CIT0011
  doi: 10.1001/archopht.119.7.1050
– ident: CIT0013
  doi: 10.1001/archopht.118.5.615
– ident: CIT0014
  doi: 10.1179/136485910X12647085215859
– ident: CIT0017
  doi: 10.1136/bjo.71.10.791
– ident: CIT0018
  doi: 10.1016/j.clae.2013.02.004
– ident: CIT0001
  doi: 10.1136/bjophthalmol-2011-300539
– volume: 84
  start-page: 1035
  year: 2000
  ident: CIT0008
  publication-title: Br J Ophthalmol
  doi: 10.1136/bjo.84.9.1035
– ident: CIT0006
  doi: 10.1016/j.ajo.2009.07.037
– ident: CIT0015
  doi: 10.1097/ICL.0000000000000006
– ident: CIT0005
  doi: 10.1097/ICO.0000000000000408
SSID ssj0024394
Score 2.178631
Snippet PROSE (prosthetic replacement of ocular surface ecosystem) device is a custom-designed, corneal vaulting scleral contact lens, which is used in the treatment...
Background PROSE (prosthetic replacement of ocular surface ecosystem) device is a custom‐designed, corneal vaulting scleral contact lens, which is used in the...
Background PROSE (prosthetic replacement of ocular surface ecosystem) device is a custom-designed, corneal vaulting scleral contact lens, which is used in the...
SourceID proquest
pubmed
crossref
wiley
informaworld
SourceType Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage 710
SubjectTerms Acuity
Adolescent
Adult
Contact Lenses
Cornea
Corneal Diseases - psychology
Corneal Diseases - therapy
Eye lens
Female
handling of PROSE device
Humans
India
irregular cornea
Male
Middle Aged
PROSE device
Prospective Studies
Prosthesis Design
Prosthesis Fitting
Quality of life
Quality of Life - psychology
Sclera
scleral contact lens
Sickness Impact Profile
Statistical analysis
Surveys and Questionnaires
Vision
Visual Acuity - physiology
Visual perception
Young Adult
Title Quality of life and handling experience with the PROSE device: an Indian scenario
URI https://www.tandfonline.com/doi/abs/10.1111/cxo.12519
https://onlinelibrary.wiley.com/doi/abs/10.1111%2Fcxo.12519
https://www.ncbi.nlm.nih.gov/pubmed/28295635
https://www.proquest.com/docview/1962042201
https://www.proquest.com/docview/1877855754
Volume 100
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LSxxBEC7Eg3gxMdG4UUNHPHiZZR490zN6ElFMwLfCHgJDP0GUGdFdSPz1VvU82A0bkNwGuhq6p7qqvu7q_gpg10gXaiXjANFuEXDldFBwqwOL2NSEqcsTS0cDZ-fZ6R3_OUpHC3DQvYVp-CH6AzeyDO-vycClepkycv27HlJ0psd7dFeLANF1PMWz54sgUl2JgGdx3LIK0S2evudMLJphKp2HN2fhq48_Jx_gVzfy5trJw3AyVkP9-hep439O7SOstLiUHTYLaRUWbPUJls7azPtnuGrINv6w2rHHe2eZrAzzFA0Y-5jtCZMZHewyRJXs8vri5pgZS65oH8XZj4rWIiP6KNyg12twd3J8e3QatOUYAs0Tyhcblak046ESJke7tw4DHcEN6XhijXKicNJm2FzoDIGo0NijCC3PlM6E4sk6LFZ1ZTeAyYhcSxSJyOXcGNz2CY39UC6WocnFAPY6xZS65SqnkhmPZbdnwV9U-l80gJ1e9Kkh6JgnFExrtxz70xDXlC4pkznyW536y9amX0r0VTExpoXRAL73zWiNlGKRla0nKJMLkacIgfkAvjTLph8V5axTxHc4Oa_8fw-3PBpd-I-v7xfdhOWYEId_JrkFi-Pnid1GvDRW37xhvAEGiQ-D
linkProvider Wiley-Blackwell
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3daxQxEB9qBfWlfuvVVqP44Mse-5Hd7Ja-lH5w1V6rtYV7KWHzBWLZLe0dVP_6zmQ_uJMTxLeFTCDZyWR-mUl-A_DRlC7UqowDRLtFwJXTQcGtDixiUxOmLk8shQbGx9nonH-epJMV2O7ewjT8EH3AjSzD79dk4BSQnrNyfVsPyT0X9-A-VfQm5vy903iOac-XQaTKEgHP4rjlFaJ7PH3XBW-0wFW6DHEuAljvgQ4ew0U39ubiyc_hbKqG-vcftI7_O7knsNZCU7bTrKWnsGKrZ_Bg3Cbfn8O3hm_jF6sdu_zhLCsrwzxLA7o_ZnvOZEaxXYbAkn09Pfm-z4yl3WgLxdlhRcuREYMUntHrF3B-sH-2OwraigyB5gmljI3KVJrxUAmTo-lbh76OEEfpeGKNcqJwpc2wudAZYlGhsUcRWp4pnQnFk5ewWtWVfQ2sjGh3iSIRuZwbgyc_obEfysVlaHIxgE-dZqRu6cqpasal7I4t-Iuk_0UD-NCLXjUcHcuEgnn1yqkPiLimeolMlshvdPqXrVnfSNyuYiJNC6MBvO-b0SApy1JWtp6hTC5EniIK5gN41aybflSUtk4R4uHkvPb_Ply5OznxH-v_LvoOHo7Oxkfy6PD4yxt4FBMA8a8mN2B1ej2zmwifpuqtt5I79GoTnw
linkToPdf http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3daxQxEB9qheKL9durVaP44Mse-5FNdvVJ2h6t2g-rhXsQwuYLSstu0Tto_eudyX5wJyeIbwuZQLKTmfklk_wG4I2tfGx0lUaIdsuIa2-ikjsTOcSmNs59kTk6Gjg8Evtn_OM0n67B-_4tTMsPMRy4kWUEf00GfmX9gpGb62ZM0bm8Bbe5iEuq27B7mi4Q7YUqiFRYIuIiTTtaIbrGM3RdCkZLVKWrAOcyfg0BaLIJ3_uht_dOLsbzmR6bX3-wOv7n3O7B3Q6Ysg_tSroPa65-ABuHXer9IXxp2TZuWOPZ5bl3rKotCxwNGPyYGxiTGZ3sMoSV7OT0-Oses4580TsUZwc1LUZG_FG4Q28ewdlk79vOftTVY4gMzyhhbLXQueCxlrZAw3ceIx3hjcrzzFntZekrJ7C5NAKRqDTYo4wdF9oIqXn2GNbrpnZPgVUJ-ZYkkYkvuLW475MG-6FcWsW2kCN42ytGmY6snGpmXKp-04K_SIVfNILXg-hVy9CxSiha1K6aheMQ39YuUdkK-e1e_aoz6p8KnVVKlGlxMoJXQzOaI-VYqto1c5QppCxyxMB8BE_aZTOMipLWOQI8nFxQ_t-Hq3amx-Fj699FX8LGye5EfT44-vQM7qSEPsKTyW1Yn_2Yu-eInWb6RbCR36s2Ek4
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Quality+of+life+and+handling+experience+with+the+PROSE+device%3A+an+Indian+scenario&rft.jtitle=Clinical+and+experimental+optometry&rft.au=Bhattacharya%2C+Pradipta&rft.au=Mahadevan%2C+Rajeswari&rft.date=2017-11-01&rft.issn=0816-4622&rft.eissn=1444-0938&rft.volume=100&rft.issue=6&rft.spage=710&rft.epage=717&rft_id=info:doi/10.1111%2Fcxo.12519&rft.externalDBID=n%2Fa&rft.externalDocID=10_1111_cxo_12519
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0816-4622&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0816-4622&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0816-4622&client=summon