Investigation of the barrier performance of disposable isolation gowns
Recent epidemics and pandemics highlighted the need for effective personal protective equipment, including isolation gowns. The most critical property of an isolation gown is its ability to keep liquids and viruses from passing through the gown. Liquid and viral barrier penetration can be measured u...
Saved in:
Published in | American Journal of Infection Control Vol. 51; no. 12; pp. 1401 - 1405 |
---|---|
Main Author | |
Format | Journal Article |
Language | English |
Published |
Elsevier Inc
01.12.2023
Elsevier BV |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Recent epidemics and pandemics highlighted the need for effective personal protective equipment, including isolation gowns. The most critical property of an isolation gown is its ability to keep liquids and viruses from passing through the gown. Liquid and viral barrier penetration can be measured using laboratory test methods. Association for the Advancement of Medical Instrumentation (AAMI) PB70 standard defines isolation gown barrier performance levels and requirements. In this study, 22 disposable isolation gown models from 6 manufacturers were tested for liquid and viral penetration resistance.
Standard test methods were used to evaluate water and viral penetration. Test results were evaluated using AAMI PB70 barrier performance criteria for 4 protection levels.
Seven of the 22 tested gown models did not pass liquid and viral penetration testing based on AAMI PB70 at the level claimed by the manufacturer. The majority of these failures occurred at the seam and/or tie attachment areas.
The study findings underscore the need for improved processes surrounding activities such as premarket testing and postmarket evaluation of gowns according to standardized test methods by third-party laboratories. This study also supports the recent Food and Drug Administration guidance document that clarified the characteristics of isolation gowns considered to be class II and subject to Food and Drug Administration premarket review. Infection preventionists, hospital purchasers, and safety professionals should seek isolation gowns demonstrating conformance to industry standards from manufacturers.
•Barrier resistance is the most critical property identified for isolation gowns.•This study investigates water and viral penetration of 22 isolation gown models.•Seven of the 22 tested gown models did not pass barrier resistance testing.•Isolation gowns on the market should be evaluated periodically.•Results emphasize the need for improved conformity assessment processes. |
---|---|
AbstractList | Recent epidemics and pandemics highlighted the need for effective personal protective equipment, including isolation gowns. The most critical property of an isolation gown is its ability to keep liquids and viruses from passing through the gown. Liquid and viral barrier penetration can be measured using laboratory test methods. Association for the Advancement of Medical Instrumentation (AAMI) PB70 standard defines isolation gown barrier performance levels and requirements. In this study, 22 disposable isolation gown models from 6 manufacturers were tested for liquid and viral penetration resistance.
Standard test methods were used to evaluate water and viral penetration. Test results were evaluated using AAMI PB70 barrier performance criteria for 4 protection levels.
Seven of the 22 tested gown models did not pass liquid and viral penetration testing based on AAMI PB70 at the level claimed by the manufacturer. The majority of these failures occurred at the seam and/or tie attachment areas.
The study findings underscore the need for improved processes surrounding activities such as premarket testing and postmarket evaluation of gowns according to standardized test methods by third-party laboratories. This study also supports the recent Food and Drug Administration guidance document that clarified the characteristics of isolation gowns considered to be class II and subject to Food and Drug Administration premarket review. Infection preventionists, hospital purchasers, and safety professionals should seek isolation gowns demonstrating conformance to industry standards from manufacturers.
•Barrier resistance is the most critical property identified for isolation gowns.•This study investigates water and viral penetration of 22 isolation gown models.•Seven of the 22 tested gown models did not pass barrier resistance testing.•Isolation gowns on the market should be evaluated periodically.•Results emphasize the need for improved conformity assessment processes. Recent epidemics and pandemics highlighted the need for effective personal protective equipment, including isolation gowns. The most critical property of an isolation gown is its ability to keep liquids and viruses from passing through the gown. Liquid and viral barrier penetration can be measured using laboratory test methods. Association for the Advancement of Medical Instrumentation (AAMI) PB70 standard defines isolation gown barrier performance levels and requirements. In this study, 22 disposable isolation gown models from 6 manufacturers were tested for liquid and viral penetration resistance.BACKGROUNDRecent epidemics and pandemics highlighted the need for effective personal protective equipment, including isolation gowns. The most critical property of an isolation gown is its ability to keep liquids and viruses from passing through the gown. Liquid and viral barrier penetration can be measured using laboratory test methods. Association for the Advancement of Medical Instrumentation (AAMI) PB70 standard defines isolation gown barrier performance levels and requirements. In this study, 22 disposable isolation gown models from 6 manufacturers were tested for liquid and viral penetration resistance.Standard test methods were used to evaluate water and viral penetration. Test results were evaluated using AAMI PB70 barrier performance criteria for 4 protection levels.METHODSStandard test methods were used to evaluate water and viral penetration. Test results were evaluated using AAMI PB70 barrier performance criteria for 4 protection levels.Seven of the 22 tested gown models did not pass liquid and viral penetration testing based on AAMI PB70 at the level claimed by the manufacturer. The majority of these failures occurred at the seam and/or tie attachment areas.RESULTSSeven of the 22 tested gown models did not pass liquid and viral penetration testing based on AAMI PB70 at the level claimed by the manufacturer. The majority of these failures occurred at the seam and/or tie attachment areas.The study findings underscore the need for improved processes surrounding activities such as premarket testing and postmarket evaluation of gowns according to standardized test methods by third-party laboratories. This study also supports the recent Food and Drug Administration guidance document that clarified the characteristics of isolation gowns considered to be class II and subject to Food and Drug Administration premarket review. Infection preventionists, hospital purchasers, and safety professionals should seek isolation gowns demonstrating conformance to industry standards from manufacturers.CONCLUSIONSThe study findings underscore the need for improved processes surrounding activities such as premarket testing and postmarket evaluation of gowns according to standardized test methods by third-party laboratories. This study also supports the recent Food and Drug Administration guidance document that clarified the characteristics of isolation gowns considered to be class II and subject to Food and Drug Administration premarket review. Infection preventionists, hospital purchasers, and safety professionals should seek isolation gowns demonstrating conformance to industry standards from manufacturers. |
Author | Kilinc-Balci, F. Selcen |
Author_xml | – sequence: 1 fullname: F Selcen, Kilinc-Balci |
BackLink | https://cir.nii.ac.jp/crid/1872272492509748736$$DView record in CiNii |
BookMark | eNp9kE1PxCAQhonRxPXjD3jqwYOX1gFaKN6McdXExIueCaWDsnbLCrua_ffS1LOZhDnwvMzwnJDDMYxIyAWFigIV16vKrLytGDBegaoA-AFZ0IbJkjMlDskCqBKlaBp-TE5SWgGA4qJZkOXT-I1p69_N1oexCK7YfmDRmRg9xmKD0YW4NqPF6ar3aROS6QYsfArDHHkPP2M6I0fODAnP__opeVvev949ls8vD093t8-lrTlsS4eU875zNQWlrDMOVScktk2NLJeV0gk0bd-7Drlj1vYOrOi4kr3AGhp-Sq7mdzcxfO3y4nrtk8VhMCOGXdKsFVyKWraQUTajNoaUIjq9iX5t4l5T0JM0vdKTND1J06B0lpZDl3No9F5bP520lYxJVivWgJJ1K7nI2M2MYf7rdzal7ZBha4ZP3Os--P9m_AJOeYKN |
Cites_doi | 10.1016/0196-6553(93)90404-R 10.1016/j.ajic.2007.10.007 10.1016/j.clinthera.2015.07.007 10.1016/j.ajic.2015.05.005 |
ContentType | Journal Article |
Copyright | 2023 Published by Elsevier Inc. |
Copyright_xml | – notice: 2023 – notice: Published by Elsevier Inc. |
DBID | RYH AAYXX CITATION 7X8 |
DOI | 10.1016/j.ajic.2023.09.003 |
DatabaseName | CiNii Complete CrossRef MEDLINE - Academic |
DatabaseTitle | CrossRef MEDLINE - Academic |
DatabaseTitleList | MEDLINE - Academic |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Public Health |
EISSN | 1527-3296 |
EndPage | 1405 |
ExternalDocumentID | 10_1016_j_ajic_2023_09_003 S0196655323006089 |
GroupedDBID | --- --K --M ..I .1- .FO .GJ .~1 0-6 0R~ 1B1 1P~ 1RT 1Z5 1~. 1~5 23M 2KS 4.4 457 4G. 53G 5GY 5RE 5VS 6J9 7-5 71M 8P~ 9JM AAAJQ AABNK AABSN AAEDT AAEDW AAIKC AAIKJ AAKOC AALRI AAMNW AAOAW AAQFI AAQXK AARKO AATTM AAWTL AAXKI AAXUO AAYWO ABBQC ABMAC ABMZM ABWVN ABXDB ACDAQ ACGFO ACGFS ACIEU ACJTP ACRLP ACRPL ACVFH ACXZT ADBBV ADCNI ADEZE ADIMB ADMUD ADNMO ADVLN AEBSH AEIPS AEKER AENEX AEUPX AEVXI AFFNX AFJKZ AFPUW AFRHN AFTJW AFXBA AFXIZ AGBRE AGCQF AGEKW AGHFR AGQPQ AGUBO AGYEJ AHHHB AIEXJ AIGII AIIUN AIKHN AITUG AJRQY AJUYK AKBMS AKRWK AKYEP ALMA_UNASSIGNED_HOLDINGS AMRAJ ANKPU ANZVX APXCP ASPBG AVWKF AXJTR AZFZN BEEDS BKOJK BLXMC BNPGV C45 CAG CJTIS COF COPKO CS3 EBS EFJIC EFKBS EJD EO8 EO9 EP2 EP3 EX3 F5P FAFAN FDB FEDTE FGOYB FIRID FNPLU FYGXN G-2 G-Q GBLVA HEJ HMK HMO HVGLF HZ~ H~W IH2 IHE J1W J5H K-O KOM L7B LUGTX M27 M41 MO0 N4W N9A O-L O9- OAUVE OD- OEN OMK ONC ONOOK OO. OUGNH OVD OZT P-8 P-9 PC. PQQKQ Q38 R2- ROL RPZ SAE SDF SDG SDP SEL SES SEW SNC SND SNG SPCBC SSH SSI SSZ T5K TEORI TWZ UGJ UHS UV1 WH7 WOQ WOW WUQ XCE YFH YOC Z5R ZGI ZXP ~G- AFCTW AGRNS RYH AAYXX CITATION RIG 7X8 |
ID | FETCH-LOGICAL-c430t-fe133dbf41099cfafe9b67e854e2e2ec77f6ea8ddfbe3f2ccdf0c6b397d6e4053 |
ISSN | 0196-6553 1527-3296 |
IngestDate | Mon Jul 21 09:33:48 EDT 2025 Tue Jul 01 03:08:22 EDT 2025 Thu Jun 26 21:06:34 EDT 2025 Tue Aug 26 16:32:44 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 12 |
Keywords | Liquid penetration Viral penetration AAMI PB70 PPE Strikethrough Barrier resistance |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c430t-fe133dbf41099cfafe9b67e854e2e2ec77f6ea8ddfbe3f2ccdf0c6b397d6e4053 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
PQID | 2863764780 |
PQPubID | 23479 |
PageCount | 5 |
ParticipantIDs | proquest_miscellaneous_2863764780 crossref_primary_10_1016_j_ajic_2023_09_003 nii_cinii_1872272492509748736 elsevier_clinicalkey_doi_10_1016_j_ajic_2023_09_003 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | December 2023 2023-12-01 2023-12-00 20231201 |
PublicationDateYYYYMMDD | 2023-12-01 |
PublicationDate_xml | – month: 12 year: 2023 text: December 2023 |
PublicationDecade | 2020 |
PublicationTitle | American Journal of Infection Control |
PublicationYear | 2023 |
Publisher | Elsevier Inc Elsevier BV |
Publisher_xml | – name: Elsevier Inc – name: Elsevier BV |
References | NIOSH. P.P.E. CASE: testing of stockpiled ANSI/AAMI PB70 level 3 surgical gowns. By Kilinc-Balci FS, Fries M, Rottach D, Shaffer R. 2018. Pittsburgh, PA: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, NPPTL Report Number P2018–0104. Federal Register Notice. National Institute for Occupational Safety and Health Partnership Opportunity on a Research Project To Evaluate the Performance of Isolation Gowns, published on April 11, 2013. Accessed February 1, 2023. Department of Labor, Occupational Safety and Health Administration. Occupational exposure to bloodborne pathogens; final rule. 29 CFR Part 1910:1030. Fed Regist 1991;56:64003–182. Amended 84 FR 21597, May 14, 2019. (bib12) 2023 McCullough (bib7) 1993; 21 Food and Drug Administration. Premarket notification requirements concerning gowns intended for use in health care settings guidance for industry and food and drug administration staff, issued on December 9, 2015. Accessed February 1, 2023. Fischer, Uyeki, Tauxe (bib2) 2015; 43 Brown (bib6) 1992 . NIOSH. P.P.E. CASE: testing of stockpiled ANSI/AAMI PB70 level 4 surgical gowns. By Rottach D, Fries M, Kilinc-Balci FS, Moore S, Shaffer R. 2017. Pittsburgh, PA: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, NPPTL Report Number P2017–0102. Holguin M. Standard precautions for healthcare workers and the role of isolation gowns, Education & Training. Fischer, Weber, Wohl (bib3) 2015; 37 NIOSH. Considerations for selecting protective clothing used in healthcare for protection against microorganisms in blood and body fluids, NIOSH/The National Personal Protective Technology Laboratory Topic Page, July 22, 2015. Accessed February 1, 2023. Centers for Disease Control and Prevention. Guidance on personal protective equipment (PPE) to be used by healthcare workers during management of patients with confirmed ebola or persons under investigation (PUIs) for ebola who are clinically unstable or have bleeding, vomiting, or diarrhea in U.S. hospitals, including procedures for donning and doffing PPE, August 27, 2015. Accessed February 2, 2023. Siegel, Rhinehart, Jackson, Chiarello (bib5) 2007; 35 Food and Drug Administration. CFR - Code of Federal Regulations Title 21. Part 878. Accessed February 9, 2023. American National Standards Institute /Association for the Advancement of Medical Instrumentation. ANSI/AAMI:PB70:2012 Liquid barrier performance and classification of protective apparel and drapes intended for use in healthcare facilities. 2012. Arlington, VA: Association for the Advancement of Medical Instrumentation. Kilinc-Balci, Selcen, Kahveci, Yorio (bib10) 2023 10.1016/j.ajic.2023.09.003_bib13 10.1016/j.ajic.2023.09.003_bib14 10.1016/j.ajic.2023.09.003_bib15 10.1016/j.ajic.2023.09.003_bib1 10.1016/j.ajic.2023.09.003_bib16 10.1016/j.ajic.2023.09.003_bib17 Siegel (10.1016/j.ajic.2023.09.003_bib5) 2007; 35 10.1016/j.ajic.2023.09.003_bib4 (10.1016/j.ajic.2023.09.003_bib12) 2023 10.1016/j.ajic.2023.09.003_bib8 10.1016/j.ajic.2023.09.003_bib9 Kilinc-Balci (10.1016/j.ajic.2023.09.003_bib10) 2023 Fischer (10.1016/j.ajic.2023.09.003_bib2) 2015; 43 Fischer (10.1016/j.ajic.2023.09.003_bib3) 2015; 37 McCullough (10.1016/j.ajic.2023.09.003_bib7) 1993; 21 Brown (10.1016/j.ajic.2023.09.003_bib6) 1992 10.1016/j.ajic.2023.09.003_bib11 |
References_xml | – volume: 43 start-page: 788 year: 2015 end-page: 793 ident: bib2 article-title: Ebola virus disease: what clinicians in the United States need to know publication-title: Am J Infect Control – start-page: 65 year: 1992 end-page: 82 ident: bib6 article-title: Protective clothing for health care workers: liquidproofness versus microbiological resistance publication-title: Performance of Protective Clothing ASTM STP 1133 – reference: Department of Labor, Occupational Safety and Health Administration. Occupational exposure to bloodborne pathogens; final rule. 29 CFR Part 1910:1030. Fed Regist 1991;56:64003–182. Amended 84 FR 21597, May 14, 2019. – reference: NIOSH. P.P.E. CASE: testing of stockpiled ANSI/AAMI PB70 level 3 surgical gowns. By Kilinc-Balci FS, Fries M, Rottach D, Shaffer R. 2018. Pittsburgh, PA: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, NPPTL Report Number P2018–0104. – reference: Food and Drug Administration. Premarket notification requirements concerning gowns intended for use in health care settings guidance for industry and food and drug administration staff, issued on December 9, 2015. Accessed February 1, 2023. – volume: 21 start-page: 368 year: 1993 end-page: 374 ident: bib7 article-title: Methods for determining the barrier efficacy of surgical gowns publication-title: Am J Infect Control – reference: Holguin M. Standard precautions for healthcare workers and the role of isolation gowns, Education & Training. – reference: . – reference: NIOSH. P.P.E. CASE: testing of stockpiled ANSI/AAMI PB70 level 4 surgical gowns. By Rottach D, Fries M, Kilinc-Balci FS, Moore S, Shaffer R. 2017. Pittsburgh, PA: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, NPPTL Report Number P2017–0102. – year: 2023 ident: bib10 article-title: The impact of surface tension on the barrier performance of gowns and coveralls publication-title: Am J Infect Control – reference: Centers for Disease Control and Prevention. Guidance on personal protective equipment (PPE) to be used by healthcare workers during management of patients with confirmed ebola or persons under investigation (PUIs) for ebola who are clinically unstable or have bleeding, vomiting, or diarrhea in U.S. hospitals, including procedures for donning and doffing PPE, August 27, 2015. Accessed February 2, 2023. – year: 2023 ident: bib12 publication-title: Standard Specification for Isolation Gowns Intended for Use in Healthcare Facilities – volume: 37 start-page: 2402 year: 2015 end-page: 2410 ident: bib3 article-title: Personal protective equipment: protecting health care providers in an ebola outbreak publication-title: Clin Ther – volume: 35 start-page: S65 year: 2007 end-page: S164 ident: bib5 article-title: Guideline for isolation precautions: preventing transmission of infectious agents in health care settings publication-title: Am J Infect Control – reference: Food and Drug Administration. CFR - Code of Federal Regulations Title 21. Part 878. Accessed February 9, 2023. – reference: Federal Register Notice. National Institute for Occupational Safety and Health Partnership Opportunity on a Research Project To Evaluate the Performance of Isolation Gowns, published on April 11, 2013. Accessed February 1, 2023. – reference: NIOSH. Considerations for selecting protective clothing used in healthcare for protection against microorganisms in blood and body fluids, NIOSH/The National Personal Protective Technology Laboratory Topic Page, July 22, 2015. Accessed February 1, 2023. – reference: American National Standards Institute /Association for the Advancement of Medical Instrumentation. ANSI/AAMI:PB70:2012 Liquid barrier performance and classification of protective apparel and drapes intended for use in healthcare facilities. 2012. Arlington, VA: Association for the Advancement of Medical Instrumentation. – volume: 21 start-page: 368 year: 1993 ident: 10.1016/j.ajic.2023.09.003_bib7 article-title: Methods for determining the barrier efficacy of surgical gowns publication-title: Am J Infect Control doi: 10.1016/0196-6553(93)90404-R – ident: 10.1016/j.ajic.2023.09.003_bib8 – year: 2023 ident: 10.1016/j.ajic.2023.09.003_bib12 – ident: 10.1016/j.ajic.2023.09.003_bib9 – year: 2023 ident: 10.1016/j.ajic.2023.09.003_bib10 article-title: The impact of surface tension on the barrier performance of gowns and coveralls publication-title: Am J Infect Control – ident: 10.1016/j.ajic.2023.09.003_bib1 – ident: 10.1016/j.ajic.2023.09.003_bib4 – ident: 10.1016/j.ajic.2023.09.003_bib17 – volume: 35 start-page: S65 year: 2007 ident: 10.1016/j.ajic.2023.09.003_bib5 article-title: Guideline for isolation precautions: preventing transmission of infectious agents in health care settings publication-title: Am J Infect Control doi: 10.1016/j.ajic.2007.10.007 – start-page: 65 year: 1992 ident: 10.1016/j.ajic.2023.09.003_bib6 article-title: Protective clothing for health care workers: liquidproofness versus microbiological resistance – ident: 10.1016/j.ajic.2023.09.003_bib16 – ident: 10.1016/j.ajic.2023.09.003_bib15 – volume: 37 start-page: 2402 year: 2015 ident: 10.1016/j.ajic.2023.09.003_bib3 article-title: Personal protective equipment: protecting health care providers in an ebola outbreak publication-title: Clin Ther doi: 10.1016/j.clinthera.2015.07.007 – ident: 10.1016/j.ajic.2023.09.003_bib11 – volume: 43 start-page: 788 year: 2015 ident: 10.1016/j.ajic.2023.09.003_bib2 article-title: Ebola virus disease: what clinicians in the United States need to know publication-title: Am J Infect Control doi: 10.1016/j.ajic.2015.05.005 – ident: 10.1016/j.ajic.2023.09.003_bib13 – ident: 10.1016/j.ajic.2023.09.003_bib14 |
SSID | ssj0009365 ssib000381235 ssib005073165 ssib045029829 ssib042110441 ssib004262146 ssib006544134 ssib006544132 |
Score | 2.3918774 |
Snippet | Recent epidemics and pandemics highlighted the need for effective personal protective equipment, including isolation gowns. The most critical property of an... |
SourceID | proquest crossref nii elsevier |
SourceType | Aggregation Database Index Database Publisher |
StartPage | 1401 |
SubjectTerms | AAMI PB70 Barrier resistance Disposable Equipment Humans Liquid penetration Patient Isolation Personal Protective Equipment PPE Protective Clothing Strikethrough Viral penetration |
Title | Investigation of the barrier performance of disposable isolation gowns |
URI | https://www.clinicalkey.com/#!/content/1-s2.0-S0196655323006089 https://cir.nii.ac.jp/crid/1872272492509748736 https://www.proquest.com/docview/2863764780 |
Volume | 51 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3Na9swFBdrdxmMsq-ydMvQYLfhIFu2bB-3sVAG2ymB3oT1VRyKU7r0ssP-9r0n2bGSpWMtARHbWCj6veh9v0fIh6xWDqTkIrFMqCQ32Mi9cZjgo3PRlKzSChXF7z_E-TL_dlFcjF36fHbJRs30r4N5JQ9BFe4Brpglew9kt5PCDfgO-MIICMP4XxhHRTKC2IdSpGpufBe66yglAB6ZFgO0fKJUC6sKr1yibTmWT7cOnJ2KEiFeqxvi2iO_fdvp5HNzpX1MwHwGR8-V7pPLelNCxqOwjN66WItEFKF673A8FmlMBll02KFuFjFOuCwOHsrBPrCaNasWi0Zm3FeWZXxkQYPbfY8zbeMFh1C0lcQ5JM4hWS19mdfHGSgI2Lti9nsM7qm5CMGr_Q_q06VCZN_-Ou4SSY66tv2LRXu5Y_GMnPQKA_0U0H9OHtnuBXkarK00JJG9JPMdSqBrR4ESaE8JNKIEfDRSAt1SAvWU8Ios518XX86TvkNGonPONomzKedGuRz9m9o1ztZKlLYqcpvBR5elE7apjHHKcpdpbRzTQoEMaoQFuPgpOe7WnX1NqE0rppVQjhuRp8qpggmjK5DmhEoLpybk47BJ8joUQpF3wzIhfNhHOaT4AlOSQBL_fGsKWy51i2NaAawlFrQEmbYEvZqLCXk_gCHhFETXVtPZ9e1PmVUCOGVeVuzsXut8Q56Mf4S35Hhzc2unIGVu1DtPUH8AI_x78A |
linkProvider | Elsevier |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Investigation+of+the+barrier+performance+of+disposable+isolation+gowns&rft.jtitle=American+journal+of+infection+control&rft.au=Kilinc-Balci%2C+F.+Selcen&rft.date=2023-12-01&rft.issn=0196-6553&rft.volume=51&rft.issue=12&rft.spage=1401&rft.epage=1405&rft_id=info:doi/10.1016%2Fj.ajic.2023.09.003&rft.externalDBID=n%2Fa&rft.externalDocID=10_1016_j_ajic_2023_09_003 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0196-6553&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0196-6553&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0196-6553&client=summon |