Metal artifact reduction using iterative CBCT reconstruction algorithm for head and neck radiation therapy: A phantom and clinical study

•Iterative CBCT can substantially reduce metal artifacts in head and neck images.•Soft tissue visualization is improved with iterative CBCT reconstruction.•Iterative CBCT is acceptable for daily head and neck IGRT. To investigate whether a novel iterative cone-beam computed tomography (CBCT) reconst...

Full description

Saved in:
Bibliographic Details
Published inEuropean journal of radiology Vol. 132; p. 109293
Main Authors Washio, Hayate, Ohira, Shingo, Funama, Yoshinori, Morimoto, Masahiro, Wada, Kentaro, Yagi, Masashi, Shimamoto, Hiroaki, Koike, Yuhei, Ueda, Yoshihiro, Karino, Tsukasa, Inui, Shoki, Nitta, Yuya, Miyazaki, Masayoshi, Teshima, Teruki
Format Journal Article
LanguageEnglish
Published Ireland Elsevier B.V 01.11.2020
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:•Iterative CBCT can substantially reduce metal artifacts in head and neck images.•Soft tissue visualization is improved with iterative CBCT reconstruction.•Iterative CBCT is acceptable for daily head and neck IGRT. To investigate whether a novel iterative cone-beam computed tomography (CBCT) reconstruction algorithm reduces metal artifacts in head and neck patient images. An anthropomorphic phantom and 35 patients with dental metal prostheses or implants were analyzed. All CBCT images were acquired using a TrueBeam linear accelerator and reconstructed with a Feldkamp–Davis–Kress algorithm-based CBCT (FDK-CBCT) and an iterative CBCT algorithm. The mean Hounsfield unit (HU) and standard deviation values were measured on the tongue near the metal materials and the unaffected region as reference values. The artifact index (AI) was calculated. For objective image analysis, the HU value and AI were compared between FDK-CBCT and iterative CBCT images in phantom and clinical studies. Subjective image analyses of metal artifact scores and soft tissue visualizations were conducted using a five-point scale by two reviewers in the clinical study. The HU value and AI showed significant artifact reduction for the iterative CBCT than for the FDK-CBCT images (phantom study: 389.8 vs.−10.3 for HU value, 322.9 vs. 96.2 for AI, FDK-CBCT vs. iterative CBCT, respectively; clinical study: 210.3 vs. 69.0 for HU value, 149.6 vs. 70.7 for AI). The subjective scores in the clinical patient study were improved in the iterative CBCT images (metal artifact score: 1.1 vs. 2.9, FDK-CBCT vs. iterative CBCT, respectively; soft tissue visualization: 1.8 vs. 3.6). The iterative CBCT reconstruction algorithm substantially reduced metal artifacts caused by dental metal prostheses and improved soft tissue visualization compared to FDK-CBCT in phantom and clinical studies.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0720-048X
1872-7727
DOI:10.1016/j.ejrad.2020.109293