Quality control for digital mammography: part II. Recommendations from the ACRIN DMIST trial

The Digital Mammography Imaging Screening Trial (DMIST), conducted under the auspices of the American College of Radiology Imaging Network (ACRIN), is a clinical trial designed to compare the accuracy of digital versus screen-film mammography in a screening population [E. Pisano et al., ACRIN 6652-D...

Full description

Saved in:
Bibliographic Details
Published inMedical physics (Lancaster) Vol. 33; no. 3; p. 737
Main Authors Yaffe, Martin J, Bloomquist, Aili K, Mawdsley, Gordon E, Pisano, Etta D, Hendrick, R Edward, Fajardo, Laurie L, Boone, John M, Kanal, Kalpana, Mahesh, Mahadevappa, Fleischman, Richard C, Och, Joseph, Williams, Mark B, Beideck, Daniel J, Maidment, Andrew D A
Format Journal Article
LanguageEnglish
Published United States 01.03.2006
Subjects
Online AccessGet more information

Cover

Loading…
Abstract The Digital Mammography Imaging Screening Trial (DMIST), conducted under the auspices of the American College of Radiology Imaging Network (ACRIN), is a clinical trial designed to compare the accuracy of digital versus screen-film mammography in a screening population [E. Pisano et al., ACRIN 6652-Digital vs. Screen-Film Mammography, ACRIN (2001)]. Part I of this work described the Quality Control program developed to ensure consistency and optimal operation of the digital equipment. For many of the tests, there were no failures during the 24 months imaging was performed in DMIST. When systems failed, they generally did so suddenly rather than through gradual deterioration of performance. In this part, the utility and effectiveness of those tests are considered. This suggests that after verification of proper operation, routine extensive testing would be of minimal value. A recommended set of tests is presented including additional and improved tests, which we believe meet the intent and spirit of the Mammography Quality Standards Act regulations to ensure that full-field digital mammography systems are functioning correctly, and consistently producing mammograms of excellent image quality.
AbstractList The Digital Mammography Imaging Screening Trial (DMIST), conducted under the auspices of the American College of Radiology Imaging Network (ACRIN), is a clinical trial designed to compare the accuracy of digital versus screen-film mammography in a screening population [E. Pisano et al., ACRIN 6652-Digital vs. Screen-Film Mammography, ACRIN (2001)]. Part I of this work described the Quality Control program developed to ensure consistency and optimal operation of the digital equipment. For many of the tests, there were no failures during the 24 months imaging was performed in DMIST. When systems failed, they generally did so suddenly rather than through gradual deterioration of performance. In this part, the utility and effectiveness of those tests are considered. This suggests that after verification of proper operation, routine extensive testing would be of minimal value. A recommended set of tests is presented including additional and improved tests, which we believe meet the intent and spirit of the Mammography Quality Standards Act regulations to ensure that full-field digital mammography systems are functioning correctly, and consistently producing mammograms of excellent image quality.
Author Kanal, Kalpana
Mahesh, Mahadevappa
Fleischman, Richard C
Hendrick, R Edward
Mawdsley, Gordon E
Bloomquist, Aili K
Och, Joseph
Williams, Mark B
Boone, John M
Maidment, Andrew D A
Pisano, Etta D
Beideck, Daniel J
Fajardo, Laurie L
Yaffe, Martin J
Author_xml – sequence: 1
  givenname: Martin J
  surname: Yaffe
  fullname: Yaffe, Martin J
  organization: Imaging Research Program, Sunnybrook and Women's College Health Sciences Centre, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5, Canada
– sequence: 2
  givenname: Aili K
  surname: Bloomquist
  fullname: Bloomquist, Aili K
– sequence: 3
  givenname: Gordon E
  surname: Mawdsley
  fullname: Mawdsley, Gordon E
– sequence: 4
  givenname: Etta D
  surname: Pisano
  fullname: Pisano, Etta D
– sequence: 5
  givenname: R Edward
  surname: Hendrick
  fullname: Hendrick, R Edward
– sequence: 6
  givenname: Laurie L
  surname: Fajardo
  fullname: Fajardo, Laurie L
– sequence: 7
  givenname: John M
  surname: Boone
  fullname: Boone, John M
– sequence: 8
  givenname: Kalpana
  surname: Kanal
  fullname: Kanal, Kalpana
– sequence: 9
  givenname: Mahadevappa
  surname: Mahesh
  fullname: Mahesh, Mahadevappa
– sequence: 10
  givenname: Richard C
  surname: Fleischman
  fullname: Fleischman, Richard C
– sequence: 11
  givenname: Joseph
  surname: Och
  fullname: Och, Joseph
– sequence: 12
  givenname: Mark B
  surname: Williams
  fullname: Williams, Mark B
– sequence: 13
  givenname: Daniel J
  surname: Beideck
  fullname: Beideck, Daniel J
– sequence: 14
  givenname: Andrew D A
  surname: Maidment
  fullname: Maidment, Andrew D A
BackLink https://www.ncbi.nlm.nih.gov/pubmed/16878576$$D View this record in MEDLINE/PubMed
BookMark eNo1j8lOwzAUAH0oogsc-AHkH0h4dr2FWxW2SAVEKTekyrGdNiiOI8c99O9BAk6juYw0czTpQ-8QuiKQE0LUDckpEQyEnKAZQMEyyoBP0XwcvwBALDmcoykRSiouxQx9vh1116YTNqFPMXS4CRHbdt8m3WGvvQ_7qIfD6RYPOiZcVTneOBO8d73VqQ39iJsYPE4Hh1flpnrBd8_V-xan2OruAp01uhvd5R8X6OPhfls-ZevXx6pcrTPDSCEzK1nDlQVRCC0t0PpHiOAKCAPGm9owxgoh6qVStHC1EQokiLoxVC6psZwu0PVvdzjW3tndEFuv42n3v0m_AX6GUVU
CitedBy_id crossref_primary_10_1007_s13246_017_0583_x
crossref_primary_10_1088_1361_6560_ac9a35
crossref_primary_10_1007_s10278_013_9571_1
crossref_primary_10_1088_0031_9155_52_5_012
crossref_primary_10_2214_AJR_12_9614
crossref_primary_10_1088_0031_9155_54_9_017
crossref_primary_10_1007_s12194_014_0277_y
crossref_primary_10_1088_0031_9155_51_21_018
crossref_primary_10_1088_0031_9155_57_21_7177
crossref_primary_10_1093_rpd_ncw049
crossref_primary_10_1148_rg_2015150036
crossref_primary_10_1007_s00330_017_4735_x
crossref_primary_10_1007_BF03178412
crossref_primary_10_1016_j_acra_2012_03_005
crossref_primary_10_1088_0031_9155_52_18_006
crossref_primary_10_1148_rg_287085053
crossref_primary_10_1118_1_3254076
crossref_primary_10_1002_mp_16786
crossref_primary_10_1118_1_4960630
crossref_primary_10_2214_AJR_09_2927
crossref_primary_10_1118_1_2163407
crossref_primary_10_1016_j_ejrad_2019_05_014
crossref_primary_10_1177_02841851221112856
crossref_primary_10_1088_2057_1976_ac9b5e
crossref_primary_10_1053_j_sembd_2006_12_004
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.1118/1.2164067
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
Physics
ExternalDocumentID 16878576
Genre Comparative Study
Evaluation Studies
Research Support, Non-U.S. Gov't
Journal Article
Research Support, N.I.H., Extramural
GroupedDBID ---
--Z
-DZ
.GJ
0R~
1OB
1OC
29M
2WC
33P
36B
3O-
4.4
476
53G
5GY
5RE
5VS
AAHHS
AANLZ
AAQQT
AASGY
AAXRX
AAZKR
ABCUV
ABEFU
ABFTF
ABJNI
ABLJU
ABQWH
ABTAH
ABXGK
ACAHQ
ACBEA
ACCFJ
ACCZN
ACGFO
ACGFS
ACGOF
ACPOU
ACXBN
ACXQS
ADBBV
ADBTR
ADKYN
ADOZA
ADXAS
ADZMN
AEEZP
AEGXH
AEIGN
AENEX
AEQDE
AEUYR
AFBPY
AFFPM
AHBTC
AIACR
AIAGR
AITYG
AIURR
AIWBW
AJBDE
ALMA_UNASSIGNED_HOLDINGS
ALUQN
AMYDB
ASPBG
BFHJK
C45
CGR
CS3
CUY
CVF
DCZOG
DRFUL
DRMAN
DRSTM
DU5
EBD
EBS
ECM
EIF
EJD
EMB
EMOBN
F5P
G8K
HDBZQ
HGLYW
I-F
KBYEO
LATKE
LEEKS
LOXES
LUTES
LYRES
MEWTI
NPM
O9-
OVD
P2P
P2W
PALCI
PHY
RJQFR
RNS
ROL
SAMSI
SUPJJ
SV3
TEORI
TN5
TWZ
USG
WOHZO
WXSBR
XJT
ZGI
ZVN
ZXP
ZY4
ZZTAW
ID FETCH-LOGICAL-c4197-d74f58d0696a7d02b58d1658014045fbc444966b38829ebc680706bfc2732cd52
ISSN 0094-2405
IngestDate Sat Sep 28 07:41:08 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 3
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c4197-d74f58d0696a7d02b58d1658014045fbc444966b38829ebc680706bfc2732cd52
PMID 16878576
ParticipantIDs pubmed_primary_16878576
PublicationCentury 2000
PublicationDate March 2006
PublicationDateYYYYMMDD 2006-03-01
PublicationDate_xml – month: 03
  year: 2006
  text: March 2006
PublicationDecade 2000
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Medical physics (Lancaster)
PublicationTitleAlternate Med Phys
PublicationYear 2006
SSID ssj0006350
Score 2.0544562
Snippet The Digital Mammography Imaging Screening Trial (DMIST), conducted under the auspices of the American College of Radiology Imaging Network (ACRIN), is a...
SourceID pubmed
SourceType Index Database
StartPage 737
SubjectTerms Breast - pathology
Breast Neoplasms - diagnosis
Breast Neoplasms - diagnostic imaging
Clinical Trials as Topic
Diagnostic Tests, Routine - instrumentation
Diagnostic Tests, Routine - methods
Health Planning Guidelines
Humans
Mammography - instrumentation
Mammography - methods
Phantoms, Imaging
Quality Control
Radiation Dosage
Radiographic Image Enhancement - instrumentation
Radiographic Image Enhancement - methods
Reproducibility of Results
Sensitivity and Specificity
Signal Processing, Computer-Assisted - instrumentation
X-Ray Intensifying Screens
Title Quality control for digital mammography: part II. Recommendations from the ACRIN DMIST trial
URI https://www.ncbi.nlm.nih.gov/pubmed/16878576
Volume 33
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1bb9MwFLY6EIgXBON-kx94izLa1HEc3sYYrEitJuikISFNtmOjSGtXtEwI_gJ_ms-XpKEaCHiJ0jiNHJ8v9jnH5zuHkOeZ4hbrikiVKGGgWCNTKdQwzYzA4qBKyz0rbTrjB0fs3XF-PBj86EUtXTRqR3-_lFfyP1LFNcjVsWT_QbLdQ3EB55AvjpAwjn8l45AA41sXb-5CBqv6s6sDkiwk-hHSUTurf4W_J5PJjtMTzxYLE2spnff4JXvvJ7Pk9XTyYZ74Wh59vbXdzwmOEO-pdexpGep6dM6Ej9JaEylATb1c7zm9OoWC_uWiDgyT3fq0XvtXp_Jr1brO38IWBh47esRhfS59cfBkv2lkDE_uOSnaKK124i2Z28jJ-xNvyIARATbuzaJFyANzyezuGAuw6mHjDfkv92AkVwsv5hEXhchDUZk_t24k2m6btshWIdyUOXOOn7ioQy8LbKb4HjFJFXr0ouuPS0Abn7FhpHhlZX6L3IxWBt0NkLlNBma5Ta5PYxzFNrl2GOR4h3yKGKIRQxQYohFDtIehl9QhiAJBdANB1CGIAkHUI4h6BFGPoLvk6M3-fO8gjRU3Us1GZZFWBbO5qIa85LKohpnCjxF0VJ-EKbdKM8ZgH6sx7LLSKM0FVgyurIYSnOkqz-6RK8uzpXlA6Bi3V9zIQusxc0UbJFOl0rly1dIYEw_J_TBCJ6uQVuWkHbtHv215TG6swfWEXLX4js1TKIWNeubF9RNaz1xE
link.rule.ids 783
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Quality+control+for+digital+mammography%3A+part+II.+Recommendations+from+the+ACRIN+DMIST+trial&rft.jtitle=Medical+physics+%28Lancaster%29&rft.au=Yaffe%2C+Martin+J&rft.au=Bloomquist%2C+Aili+K&rft.au=Mawdsley%2C+Gordon+E&rft.au=Pisano%2C+Etta+D&rft.date=2006-03-01&rft.issn=0094-2405&rft.volume=33&rft.issue=3&rft.spage=737&rft_id=info:doi/10.1118%2F1.2164067&rft_id=info%3Apmid%2F16878576&rft_id=info%3Apmid%2F16878576&rft.externalDocID=16878576
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0094-2405&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0094-2405&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0094-2405&client=summon