Reliability of a Virtual Prosthodontic Project Realized through a 2D and 3D Photographic Acquisition: An Experimental Study on the Accuracy of Different Digital Systems
Aims: The study aims to assess the accuracy of digital planning in dentistry, evaluating the characteristics of different intraoral 3D scanners and comparing it with traditional imaging 2D recording methods. Specifically, using computer aided design (CAD) software and measuring inside CAD software,...
Saved in:
Published in | International journal of environmental research and public health Vol. 16; no. 24; p. 5139 |
---|---|
Main Authors | , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Switzerland
MDPI AG
16.12.2019
MDPI |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Aims: The study aims to assess the accuracy of digital planning in dentistry, evaluating the characteristics of different intraoral 3D scanners and comparing it with traditional imaging 2D recording methods. Specifically, using computer aided design (CAD) software and measuring inside CAD software, authors want to verify the reliability of different models obtained with different techniques and machines. Methods: 12 patients that needed aesthetic restorative treatment were enrolled in the study. All the patients underwent recording data of the height and width dental elements 1.1, 1.2, and 1.3 size using different technologies and comparing 2D with 3D methods. A T test was then applied in order to verify whether there was a statistically significant difference between the measurements obtained, comparing the different tools data (Emerald, TRIOS, Photogrammetry and DSS (Digital Smile System)) with the reference values. Results: No significant differences emerged in the measurements made with the different scanners (Trios 3Shape ®, Planmeca Emerald ®) and photogrammetry. Therefore, what should be underlined regarding the 2D measurements is the speed and simplicity compared to all 3D techniques, so this work can help to better define the field of application and the limits connected to 2D techniques, giving a good window of the technique. Conclusions: The low number of patients is not sufficient to provide statistically significant results, but the digital planning future prospects seem to be promising. This study results highlighted how a photogrammetric scanner for dental arches would only have a much smaller shooting field size and greater accuracy. Despite these considerations, the photogrammetric facial scanner provided excellent results for the measurement of individual teeth, showing a great versatility of use. |
---|---|
AbstractList | Aims: The study aims to assess the accuracy of digital planning in dentistry, evaluating the characteristics of different intraoral 3D scanners and comparing it with traditional imaging 2D recording methods. Specifically, using computer aided design (CAD) software and measuring inside CAD software, authors want to verify the reliability of different models obtained with different techniques and machines. Methods: 12 patients that needed aesthetic restorative treatment were enrolled in the study. All the patients underwent recording data of the height and width dental elements 1.1, 1.2, and 1.3 size using different technologies and comparing 2D with 3D methods. A T test was then applied in order to verify whether there was a statistically significant difference between the measurements obtained, comparing the different tools data (Emerald, TRIOS, Photogrammetry and DSS (Digital Smile System)) with the reference values. Results: No significant differences emerged in the measurements made with the different scanners (Trios 3Shape ®, Planmeca Emerald ®) and photogrammetry. Therefore, what should be underlined regarding the 2D measurements is the speed and simplicity compared to all 3D techniques, so this work can help to better define the field of application and the limits connected to 2D techniques, giving a good window of the technique. Conclusions: The low number of patients is not sufficient to provide statistically significant results, but the digital planning future prospects seem to be promising. This study results highlighted how a photogrammetric scanner for dental arches would only have a much smaller shooting field size and greater accuracy. Despite these considerations, the photogrammetric facial scanner provided excellent results for the measurement of individual teeth, showing a great versatility of use. The study aims to assess the accuracy of digital planning in dentistry, evaluating the characteristics of different intraoral 3D scanners and comparing it with traditional imaging 2D recording methods. Specifically, using computer aided design (CAD) software and measuring inside CAD software, authors want to verify the reliability of different models obtained with different techniques and machines.AIMSThe study aims to assess the accuracy of digital planning in dentistry, evaluating the characteristics of different intraoral 3D scanners and comparing it with traditional imaging 2D recording methods. Specifically, using computer aided design (CAD) software and measuring inside CAD software, authors want to verify the reliability of different models obtained with different techniques and machines.12 patients that needed aesthetic restorative treatment were enrolled in the study. All the patients underwent recording data of the height and width dental elements 1.1, 1.2, and 1.3 size using different technologies and comparing 2D with 3D methods. A T test was then applied in order to verify whether there was a statistically significant difference between the measurements obtained, comparing the different tools data (Emerald, TRIOS, Photogrammetry and DSS (Digital Smile System)) with the reference values.METHODS12 patients that needed aesthetic restorative treatment were enrolled in the study. All the patients underwent recording data of the height and width dental elements 1.1, 1.2, and 1.3 size using different technologies and comparing 2D with 3D methods. A T test was then applied in order to verify whether there was a statistically significant difference between the measurements obtained, comparing the different tools data (Emerald, TRIOS, Photogrammetry and DSS (Digital Smile System)) with the reference values.No significant differences emerged in the measurements made with the different scanners (Trios 3Shape ®, Planmeca Emerald ®) and photogrammetry. Therefore, what should be underlined regarding the 2D measurements is the speed and simplicity compared to all 3D techniques, so this work can help to better define the field of application and the limits connected to 2D techniques, giving a good window of the technique.RESULTSNo significant differences emerged in the measurements made with the different scanners (Trios 3Shape ®, Planmeca Emerald ®) and photogrammetry. Therefore, what should be underlined regarding the 2D measurements is the speed and simplicity compared to all 3D techniques, so this work can help to better define the field of application and the limits connected to 2D techniques, giving a good window of the technique.The low number of patients is not sufficient to provide statistically significant results, but the digital planning future prospects seem to be promising. This study results highlighted how a photogrammetric scanner for dental arches would only have a much smaller shooting field size and greater accuracy. Despite these considerations, the photogrammetric facial scanner provided excellent results for the measurement of individual teeth, showing a great versatility of use.CONCLUSIONSThe low number of patients is not sufficient to provide statistically significant results, but the digital planning future prospects seem to be promising. This study results highlighted how a photogrammetric scanner for dental arches would only have a much smaller shooting field size and greater accuracy. Despite these considerations, the photogrammetric facial scanner provided excellent results for the measurement of individual teeth, showing a great versatility of use. The study aims to assess the accuracy of digital planning in dentistry, evaluating the characteristics of different intraoral 3D scanners and comparing it with traditional imaging 2D recording methods. Specifically, using computer aided design (CAD) software and measuring inside CAD software, authors want to verify the reliability of different models obtained with different techniques and machines. 12 patients that needed aesthetic restorative treatment were enrolled in the study. All the patients underwent recording data of the height and width dental elements 1.1, 1.2, and 1.3 size using different technologies and comparing 2D with 3D methods. A T test was then applied in order to verify whether there was a statistically significant difference between the measurements obtained, comparing the different tools data (Emerald, TRIOS, Photogrammetry and DSS (Digital Smile System)) with the reference values. No significant differences emerged in the measurements made with the different scanners (Trios 3Shape , Planmeca Emerald ) and photogrammetry. Therefore, what should be underlined regarding the 2D measurements is the speed and simplicity compared to all 3D techniques, so this work can help to better define the field of application and the limits connected to 2D techniques, giving a good window of the technique. The low number of patients is not sufficient to provide statistically significant results, but the digital planning future prospects seem to be promising. This study results highlighted how a photogrammetric scanner for dental arches would only have a much smaller shooting field size and greater accuracy. Despite these considerations, the photogrammetric facial scanner provided excellent results for the measurement of individual teeth, showing a great versatility of use. Aims: The study aims to assess the accuracy of digital planning in dentistry, evaluating the characteristics of different intraoral 3D scanners and comparing it with traditional imaging 2D recording methods. Specifically, using computer aided design (CAD) software and measuring inside CAD software, authors want to verify the reliability of different models obtained with different techniques and machines. Methods: 12 patients that needed aesthetic restorative treatment were enrolled in the study. All the patients underwent recording data of the height and width dental elements 1.1, 1.2, and 1.3 size using different technologies and comparing 2D with 3D methods. A T test was then applied in order to verify whether there was a statistically significant difference between the measurements obtained, comparing the different tools data (Emerald, TRIOS, Photogrammetry and DSS (Digital Smile System)) with the reference values. Results: No significant differences emerged in the measurements made with the different scanners (Trios 3Shape ® , Planmeca Emerald ® ) and photogrammetry. Therefore, what should be underlined regarding the 2D measurements is the speed and simplicity compared to all 3D techniques, so this work can help to better define the field of application and the limits connected to 2D techniques, giving a good window of the technique. Conclusions: The low number of patients is not sufficient to provide statistically significant results, but the digital planning future prospects seem to be promising. This study results highlighted how a photogrammetric scanner for dental arches would only have a much smaller shooting field size and greater accuracy. Despite these considerations, the photogrammetric facial scanner provided excellent results for the measurement of individual teeth, showing a great versatility of use. The subjects involved in dental treatment therefore favored comfortable clinical procedures, as well as other factors such as the precision of the procedures, the effectiveness of diagnostic devices, and the clinical experience of the dental team, which were all important elements for the final success [5,6,7,8,9]. [...]there is a need to replace conventional clinical procedures requiring physical contact with the patient with others that reduce the patient’s direct involvement and treatment times—without affecting the precision and aesthetic performance of the final prosthesis. The present study therefore aims to verify the reliability of the virtual planning of aesthetic cases, carried out starting from photographic acquisitions of the patient’s face using different technologies able to return on the one hand traditional, two-dimensional images, and from the innovative, three-dimensional representations. 2. Variables and Measurements The obtained values from the measurements performed on the 3D virtual models created by the scanning of the plaster models have been taken as reference values. |
Author | Lavorgna, Luca Di Leo, Giovanni Troiano, Giuseppe Ortensi, Marco Fiorillo, Luca Cervino, Gabriele Galantucci, Luigi Cicciù, Marco |
AuthorAffiliation | 1 Private Practice, Telese Terme 82037, Italy; info@odontosinergy.it (L.L.); giovannidileo@outlook.com (G.D.L.) 4 Department of Mechanics and Mathematics Management, University of Bari, 70100 Bari, Italy; luigimaria.galantucci@poliba.it 3 Department of Prosthodontics, University of Foggia, 71100 Foggia, Italy; giuseppe.troiano@unifg.it (G.T.); marco.ortensi90@gmail.com (M.O.) 2 Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, 98100 Messina, Italy; gcervino@unime.it |
AuthorAffiliation_xml | – name: 3 Department of Prosthodontics, University of Foggia, 71100 Foggia, Italy; giuseppe.troiano@unifg.it (G.T.); marco.ortensi90@gmail.com (M.O.) – name: 1 Private Practice, Telese Terme 82037, Italy; info@odontosinergy.it (L.L.); giovannidileo@outlook.com (G.D.L.) – name: 4 Department of Mechanics and Mathematics Management, University of Bari, 70100 Bari, Italy; luigimaria.galantucci@poliba.it – name: 2 Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, 98100 Messina, Italy; gcervino@unime.it |
Author_xml | – sequence: 1 givenname: Luca surname: Lavorgna fullname: Lavorgna, Luca – sequence: 2 givenname: Gabriele orcidid: 0000-0003-4619-4691 surname: Cervino fullname: Cervino, Gabriele – sequence: 3 givenname: Luca orcidid: 0000-0003-0335-4165 surname: Fiorillo fullname: Fiorillo, Luca – sequence: 4 givenname: Giovanni surname: Di Leo fullname: Di Leo, Giovanni – sequence: 5 givenname: Giuseppe orcidid: 0000-0001-5647-4414 surname: Troiano fullname: Troiano, Giuseppe – sequence: 6 givenname: Marco surname: Ortensi fullname: Ortensi, Marco – sequence: 7 givenname: Luigi orcidid: 0000-0003-2892-7433 surname: Galantucci fullname: Galantucci, Luigi – sequence: 8 givenname: Marco orcidid: 0000-0003-2311-9728 surname: Cicciù fullname: Cicciù, Marco |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/31888225$$D View this record in MEDLINE/PubMed |
BookMark | eNp1kstq3DAUhkVJaS7ttssi6KabSSXLluUuCkMmSQuBhPSyNbJ8PNbgkRxJLp0-UR4zZ3IjCXSlI_T9_7lpn-w474CQ95wdClGxz3YFYey5zPKCi-oV2eNSslkuGd95Eu-S_RhXjAmVy-oN2RVcKZVlxR65voTB6sYONm2o76imv21Ikx7oRfAx9b71Llmzva3AJHoJerD_oKWpD35a9ijIFlS7looFveh98sugxx4Vc3M12WiT9e4LnTt6_HeEYNfgEpr_SFOL-RzaAJJmCtrc5l_YroOAEEZLe4tuYoJ1fEted3qI8O7-PCC_To5_Hn2bnZ2ffj-an81MzlWalW0ru1byttG86UyRm0pLaE0pNWSiAANKd7wyolANzqJQTJaas6xkTZMDSHFAvt75jlOzRiGWEvRQj1i6Dpvaa1s_f3G2r5f-T41mjGcFGny6Nwj-aoKY6rWNBoZBO_BTrDMhuBRFznNEP75AV34KDttDKqukVKUokfrwtKLHUh6WiMDhHWBwZTFA94hwVm9_Sf38l6AgfyEwOOrtprAjO_xPdgN_9MW8 |
CitedBy_id | crossref_primary_10_1186_s12903_023_02918_y crossref_primary_10_3390_medicina59071311 crossref_primary_10_7759_cureus_62459 crossref_primary_10_1186_s12903_023_02811_8 crossref_primary_10_1097_SCS_0000000000006392 crossref_primary_10_3390_jcm9041238 crossref_primary_10_1016_j_prosdent_2020_10_015 crossref_primary_10_1097_SCS_0000000000008370 crossref_primary_10_3390_jcs7020080 crossref_primary_10_1097_SCS_0000000000008569 crossref_primary_10_1097_SCS_0000000000006941 crossref_primary_10_3390_app11031122 crossref_primary_10_1016_j_compbiomed_2021_104256 crossref_primary_10_23736_S2724_6329_21_04595_2 crossref_primary_10_23736_S2724_6329_21_04591_5 crossref_primary_10_25259_APOS_26_2024 crossref_primary_10_3390_app10217890 crossref_primary_10_26634_jidat_15_1_21542 crossref_primary_10_3390_ma13081982 crossref_primary_10_23736_S0026_4970_20_04374_5 crossref_primary_10_3390_ma13132894 crossref_primary_10_1007_s40496_021_00293_7 crossref_primary_10_3390_prosthesis4010004 crossref_primary_10_1111_clr_14230 crossref_primary_10_3390_prosthesis6010011 crossref_primary_10_1002_cre2_570 crossref_primary_10_1186_s12903_021_02008_x crossref_primary_10_3390_prosthesis2030013 crossref_primary_10_3390_app10061975 crossref_primary_10_3390_ijerph18010229 crossref_primary_10_14815_kjdm_2021_48_4_293 crossref_primary_10_1371_journal_pone_0259794 crossref_primary_10_5005_jp_journals_10024_3575 crossref_primary_10_1055_s_0040_1713952 crossref_primary_10_1515_em_2020_0003 crossref_primary_10_1002_cnm_3672 crossref_primary_10_1186_s12903_023_03344_w crossref_primary_10_3390_prosthesis2020009 crossref_primary_10_5005_jp_journals_10015_2316 crossref_primary_10_1097_SCS_0000000000007653 crossref_primary_10_23736_S2724_6329_23_04833_7 crossref_primary_10_1097_SCS_0000000000006926 crossref_primary_10_1136_bcr_2021_243576 crossref_primary_10_3390_ma13092172 crossref_primary_10_1097_SCS_0000000000008505 crossref_primary_10_3390_ijerph18010094 crossref_primary_10_1016_j_prosdent_2021_09_015 crossref_primary_10_1080_27705781_2025_2466130 crossref_primary_10_1563_aaid_joi_D_20_00014 crossref_primary_10_1002_ccr3_3104 crossref_primary_10_1563_aaid_joi_D_19_00125 crossref_primary_10_3390_prosthesis4030040 crossref_primary_10_1097_SCS_0000000000008332 crossref_primary_10_3390_jfmk5020024 crossref_primary_10_1097_SCS_0000000000008619 crossref_primary_10_3390_app11093947 crossref_primary_10_1016_j_bjps_2022_02_055 |
Cites_doi | 10.3390/medicina55100678 10.1007/s10103-011-0904-3 10.3390/ma12121958 10.2174/1874210601105010071 10.4103/1305-7456.110155 10.1007/s00784-019-02995-w 10.3390/dj7020030 10.11607/jomi.2667 10.3390/ma12091524 10.23736/S0026-4970.19.04288-2 10.3390/ijerph16050829 10.3390/md17010018 10.1016/j.jpor.2019.07.010 10.21815/JDE.017.081 10.1155/2015/164065 10.3390/ijms19071908 10.1111/j.1875-595X.2011.00043.x 10.1016/j.prosdent.2016.10.019 10.11607/jomi.3900 10.2174/1874210601812010219 10.1111/clr.12600 10.1155/2019/4274715 10.1111/clr.12982 10.3390/ma12040592 10.3390/ma12111763 10.1111/jopr.12410 10.1186/s12903-019-0922-2 10.1016/j.prosdent.2019.01.016 10.1177/1055665619835082 10.1186/1472-6831-14-10 10.1155/2016/9840594 10.1186/s12903-019-0792-7 10.1097/SCS.0000000000003210 10.1563/aaid-joi-D-19-00140 10.1111/cid.12039 10.1016/j.prosdent.2018.04.021 10.2174/1874210601711010171 10.1186/s12903-019-0746-0 |
ContentType | Journal Article |
Copyright | 2019. This work is licensed under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. 2019 by the authors. 2019 |
Copyright_xml | – notice: 2019. This work is licensed under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. – notice: 2019 by the authors. 2019 |
DBID | AAYXX CITATION CGR CUY CVF ECM EIF NPM 3V. 7X7 7XB 88E 8C1 8FI 8FJ 8FK ABUWG AFKRA AZQEC BENPR CCPQU DWQXO FYUFA GHDGH K9. M0S M1P PHGZM PHGZT PIMPY PJZUB PKEHL PPXIY PQEST PQQKQ PQUKI PRINS 7X8 5PM |
DOI | 10.3390/ijerph16245139 |
DatabaseName | CrossRef Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed ProQuest Central (Corporate) Health & Medical Collection ProQuest Central (purchase pre-March 2016) Medical Database (Alumni Edition) Public Health Database Hospital Premium Collection Hospital Premium Collection (Alumni Edition) ProQuest Central (Alumni) (purchase pre-March 2016) ProQuest Central (Alumni) ProQuest Central UK/Ireland ProQuest Central Essentials ProQuest Central ProQuest One Community College ProQuest Central Health Research Premium Collection (ProQuest) Health Research Premium Collection (Alumni) ProQuest Health & Medical Complete (Alumni) ProQuest Health & Medical Collection Medical Database ProQuest Central Premium ProQuest One Academic Publicly Available Content Database ProQuest Health & Medical Research Collection ProQuest One Academic Middle East (New) ProQuest One Health & Nursing ProQuest One Academic Eastern Edition (DO NOT USE) ProQuest One Academic ProQuest One Academic UKI Edition ProQuest Central China MEDLINE - Academic PubMed Central (Full Participant titles) |
DatabaseTitle | CrossRef MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) Publicly Available Content Database ProQuest One Academic Middle East (New) ProQuest Central Essentials ProQuest Health & Medical Complete (Alumni) ProQuest Central (Alumni Edition) ProQuest One Community College ProQuest One Health & Nursing ProQuest Central China ProQuest Central ProQuest Health & Medical Research Collection Health Research Premium Collection Health and Medicine Complete (Alumni Edition) ProQuest Central Korea Health & Medical Research Collection ProQuest Central (New) ProQuest Medical Library (Alumni) ProQuest Public Health ProQuest One Academic Eastern Edition ProQuest Hospital Collection Health Research Premium Collection (Alumni) ProQuest Hospital Collection (Alumni) ProQuest Health & Medical Complete ProQuest Medical Library ProQuest One Academic UKI Edition ProQuest One Academic ProQuest One Academic (New) ProQuest Central (Alumni) MEDLINE - Academic |
DatabaseTitleList | CrossRef MEDLINE - Academic MEDLINE Publicly Available Content Database |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database – sequence: 3 dbid: BENPR name: ProQuest Central url: https://www.proquest.com/central sourceTypes: Aggregation Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Public Health Dentistry |
EISSN | 1660-4601 |
ExternalDocumentID | PMC6950125 31888225 10_3390_ijerph16245139 |
Genre | Journal Article |
GeographicLocations | Denmark Italy Japan Germany |
GeographicLocations_xml | – name: Denmark – name: Germany – name: Italy – name: Japan |
GroupedDBID | --- 29J 2WC 53G 5GY 5VS 7X7 7XC 88E 8C1 8FE 8FG 8FH 8FI 8FJ 8R4 8R5 A8Z AADQD AAFWJ AAHBH AAYXX ABGAM ABUWG ACGFO ACGOD ACIWK ADBBV AENEX AFKRA AFRAH AFZYC AHMBA ALIPV ALMA_UNASSIGNED_HOLDINGS AOIJS BAWUL BCNDV BENPR BPHCQ BVXVI CCPQU CITATION CS3 DIK DU5 E3Z EBD EBS EJD EMB EMOBN F5P FYUFA GX1 HH5 HMCUK HYE KQ8 L6V M1P M48 MODMG O5R O5S OK1 OVT P2P PGMZT PHGZM PHGZT PIMPY PQQKQ PROAC PSQYO Q2X RNS RPM SV3 TR2 UKHRP XSB CGR CUY CVF ECM EIF NPM 3V. 7XB 8FK AZQEC DWQXO K9. PJZUB PKEHL PPXIY PQEST PQUKI PRINS 7X8 5PM |
ID | FETCH-LOGICAL-c418t-7dd6fd61dba1bfc54c9a6edc76ae235ece8af19c358b46958067a10270bb4ee63 |
IEDL.DBID | M48 |
ISSN | 1660-4601 1661-7827 |
IngestDate | Thu Aug 21 18:30:35 EDT 2025 Mon Jul 21 11:08:30 EDT 2025 Fri Jul 25 19:57:34 EDT 2025 Thu Apr 03 06:59:50 EDT 2025 Tue Jul 01 04:04:16 EDT 2025 Thu Apr 24 23:04:11 EDT 2025 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 24 |
Keywords | digital workflow virtual digital planning prosthodontic dentistry intraoral scanner |
Language | English |
License | https://creativecommons.org/licenses/by/4.0 Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c418t-7dd6fd61dba1bfc54c9a6edc76ae235ece8af19c358b46958067a10270bb4ee63 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
ORCID | 0000-0003-4619-4691 0000-0003-0335-4165 0000-0003-2892-7433 0000-0003-2311-9728 0000-0001-5647-4414 |
OpenAccessLink | http://journals.scholarsportal.info/openUrl.xqy?doi=10.3390/ijerph16245139 |
PMID | 31888225 |
PQID | 2329668737 |
PQPubID | 54923 |
ParticipantIDs | pubmedcentral_primary_oai_pubmedcentral_nih_gov_6950125 proquest_miscellaneous_2331635414 proquest_journals_2329668737 pubmed_primary_31888225 crossref_primary_10_3390_ijerph16245139 crossref_citationtrail_10_3390_ijerph16245139 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2019-12-16 |
PublicationDateYYYYMMDD | 2019-12-16 |
PublicationDate_xml | – month: 12 year: 2019 text: 2019-12-16 day: 16 |
PublicationDecade | 2010 |
PublicationPlace | Switzerland |
PublicationPlace_xml | – name: Switzerland – name: Basel |
PublicationTitle | International journal of environmental research and public health |
PublicationTitleAlternate | Int J Environ Res Public Health |
PublicationYear | 2019 |
Publisher | MDPI AG MDPI |
Publisher_xml | – name: MDPI AG – name: MDPI |
References | Sailer (ref_2) 2019; 121 Mangano (ref_34) 2012; 27 ref_14 ref_13 ref_12 Newby (ref_24) 2011; 61 ref_11 ref_33 ref_10 Herford (ref_16) 2017; 28 ref_32 ref_30 Giuliani (ref_36) 2014; 16 Joda (ref_20) 2016; 27 Gherlone (ref_22) 2016; 31 Mangano (ref_29) 2013; 28 Gjelvold (ref_21) 2016; 25 ref_38 ref_37 Cervino (ref_39) 2019; 29 Cervino (ref_26) 2018; 12 Bramanti (ref_27) 2013; 6 Rancitelli (ref_18) 2017; 11 Sakornwimon (ref_17) 2017; 118 Cervino (ref_42) 2020; 1 Mendes (ref_31) 2019; 7 ref_25 Joda (ref_19) 2017; 28 ref_23 (ref_43) 2020; 1 Maiorana (ref_41) 2011; 5 ref_1 Germano (ref_40) 2013; 7 ref_3 Zitzmann (ref_15) 2017; 81 ref_28 ref_9 ref_8 ref_5 Zarone (ref_35) 2016; 2016 ref_4 Patel (ref_6) 2019; 56 ref_7 |
References_xml | – ident: ref_5 doi: 10.3390/medicina55100678 – volume: 27 start-page: 181 year: 2012 ident: ref_34 article-title: Prospective clinical evaluation of 201 direct laser metal forming implants: Results from a 1-year multicenter study publication-title: Lasers Med. Sci. doi: 10.1007/s10103-011-0904-3 – ident: ref_7 doi: 10.3390/ma12121958 – volume: 5 start-page: 71 year: 2011 ident: ref_41 article-title: Histomorphometric evaluation of anorganic bovine bone coverage to reduce autogenous grafts resorption: Preliminary results publication-title: Open Dent. J. doi: 10.2174/1874210601105010071 – volume: 7 start-page: 152 year: 2013 ident: ref_40 article-title: Atomic force microscopy of bacteria from periodontal subgingival biofilm: Preliminary study results publication-title: Eur. J. Dent. doi: 10.4103/1305-7456.110155 – ident: ref_3 doi: 10.1007/s00784-019-02995-w – ident: ref_12 doi: 10.3390/dj7020030 – volume: 28 start-page: 51 year: 2013 ident: ref_29 article-title: Maxillary sinus grafting with biphasic calcium phosphate ceramics: Clinical and histologic evaluation in man publication-title: Int. J. Oral Maxillofac. Implant. doi: 10.11607/jomi.2667 – ident: ref_38 doi: 10.3390/ma12091524 – ident: ref_4 doi: 10.23736/S0026-4970.19.04288-2 – ident: ref_13 doi: 10.3390/ijerph16050829 – ident: ref_14 doi: 10.3390/md17010018 – ident: ref_10 doi: 10.1016/j.jpor.2019.07.010 – volume: 81 start-page: 1227 year: 2017 ident: ref_15 article-title: Dental students’ perceptions of digital and conventional impression techniques: A randomized controlled Trial publication-title: J. Dent. Educ. doi: 10.21815/JDE.017.081 – ident: ref_25 doi: 10.1155/2015/164065 – ident: ref_28 doi: 10.3390/ijms19071908 – volume: 1 start-page: 1 year: 2020 ident: ref_43 article-title: Prosthesis: new technological opportunities and innovative biomedical devices publication-title: Prostheses – volume: 61 start-page: 4 year: 2011 ident: ref_24 article-title: Quantification of gingival contour and volume from digital impressions as a novel method for assessing gingival health publication-title: Int. Dent. J. doi: 10.1111/j.1875-595X.2011.00043.x – volume: 118 start-page: 386 year: 2017 ident: ref_17 article-title: Clinical marginal fit of zirconia crowns and patients’ preferences for impression techniques using intraoral digital scanner versus polyvinyl siloxane material publication-title: J. Prosthet. Dent. doi: 10.1016/j.prosdent.2016.10.019 – volume: 31 start-page: 324 year: 2016 ident: ref_22 article-title: Conventional versus digital impressions for “all-on-four” restorations publication-title: Int. J. Oral Maxillofac. Implant. doi: 10.11607/jomi.3900 – volume: 12 start-page: 219 year: 2018 ident: ref_26 article-title: Fem and von mises analysis of OSSTEM ® dental implant structural components: evaluation of different direction dynamic loads publication-title: Open Dent. J. doi: 10.2174/1874210601812010219 – volume: 27 start-page: e185 year: 2016 ident: ref_20 article-title: Patient-centered outcomes comparing digital and conventional implant impression procedures: A randomized crossover trial publication-title: Clin. Oral Implant. Res. doi: 10.1111/clr.12600 – ident: ref_9 doi: 10.1155/2019/4274715 – volume: 28 start-page: 1318 year: 2017 ident: ref_19 article-title: Time efficiency, difficulty, and operator’s preference comparing digital and conventional implant impressions: A randomized controlled trial publication-title: Clin. Oral Implant. Res. doi: 10.1111/clr.12982 – ident: ref_11 doi: 10.3390/ma12040592 – volume: 1 start-page: 41 year: 2020 ident: ref_42 article-title: Prosthetic and mechanical parameters of the facial bone under the load of different dental implant shapes: A parametric study publication-title: Prostheses – volume: 7 start-page: 2050313x19871131 year: 2019 ident: ref_31 article-title: Total digital workflow in the fabrication of a partial removable dental prostheses: A case report publication-title: SAGE Open Med. Case Rep. – ident: ref_37 doi: 10.3390/ma12111763 – volume: 25 start-page: 282 year: 2016 ident: ref_21 article-title: Intraoral digital impression technique compared to conventional impression technique. A randomized clinical trial publication-title: J. Prosthodont. doi: 10.1111/jopr.12410 – ident: ref_30 doi: 10.1186/s12903-019-0922-2 – ident: ref_1 doi: 10.1016/j.prosdent.2019.01.016 – volume: 56 start-page: 1120 year: 2019 ident: ref_6 article-title: Intraoral digital impression technique for a neonate with bilateral cleft lip and palate publication-title: Cleft Palate-Craniofacial J. doi: 10.1177/1055665619835082 – ident: ref_23 doi: 10.1186/1472-6831-14-10 – volume: 2016 start-page: 10 year: 2016 ident: ref_35 article-title: “Digitally Oriented Materials”: Focus on Lithium Disilicate Ceramics publication-title: Int. J. Dent. doi: 10.1155/2016/9840594 – ident: ref_33 doi: 10.1186/s12903-019-0792-7 – volume: 28 start-page: e112 year: 2017 ident: ref_16 article-title: Tissue fluorescence imaging (VELscope) for quick non-invasive diagnosis in oral pathology publication-title: J. Craniofacial Surgery doi: 10.1097/SCS.0000000000003210 – ident: ref_8 doi: 10.1563/aaid-joi-D-19-00140 – volume: 16 start-page: 736 year: 2014 ident: ref_36 article-title: In vivo regenerative properties of coralline-derived (biocoral) scaffold grafts in human maxillary defects: Demonstrative and comparative study with beta-tricalcium phosphate and biphasic calcium phosphate by synchrotron radiation X-Ray microtomography publication-title: Clin. Implant Dent. Relat. Res. doi: 10.1111/cid.12039 – volume: 121 start-page: 69 year: 2019 ident: ref_2 article-title: Randomized controlled clinical trial of digital and conventional workflows for the fabrication of zirconia-ceramic fixed partial dentures. Part I: Time efficiency of complete-arch digital scans versus conventional impressions publication-title: J. Prosthet. Dent. doi: 10.1016/j.prosdent.2018.04.021 – volume: 11 start-page: 171 year: 2017 ident: ref_18 article-title: Reproducibility of a digital method to evaluate soft tissue modifications: A study of inter and intra-operative measurement concordance publication-title: Open Dent. J. doi: 10.2174/1874210601711010171 – volume: 29 start-page: 565 year: 2019 ident: ref_39 article-title: Application of bioengineering devices for the stress evaluation in dentistry: the last 10 years fem parametric analysis of outcomes and current trends publication-title: Minerva Stomatol. – volume: 6 start-page: 37 year: 2013 ident: ref_27 article-title: Oral health-related quality of life in partially edentulous patients before and after implant therapy: A 2-year longitudinal study publication-title: Oral Implantol. – ident: ref_32 doi: 10.1186/s12903-019-0746-0 |
SSID | ssj0038469 |
Score | 2.4484093 |
Snippet | Aims: The study aims to assess the accuracy of digital planning in dentistry, evaluating the characteristics of different intraoral 3D scanners and comparing... The study aims to assess the accuracy of digital planning in dentistry, evaluating the characteristics of different intraoral 3D scanners and comparing it with... The subjects involved in dental treatment therefore favored comfortable clinical procedures, as well as other factors such as the precision of the procedures,... |
SourceID | pubmedcentral proquest pubmed crossref |
SourceType | Open Access Repository Aggregation Database Index Database Enrichment Source |
StartPage | 5139 |
SubjectTerms | Accuracy Aesthetics Computer-Aided Design - standards Dental Arch - diagnostic imaging Dental Impression Technique - standards Dentistry Humans Imaging, Three-Dimensional - standards Laboratories Patient satisfaction Photography, Dental - standards Prostheses Prosthodontics - methods Reproducibility of Results Scanners Software Software - standards Virtual Reality |
SummonAdditionalLinks | – databaseName: Health & Medical Collection dbid: 7X7 link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV3fb9MwED7BeAAJIRi_AgMZCYmnaE1sxy4vqKKbJiTQhBjqW-TYDg1CydalD9tfxJ_JXeyGFgRvqXKuo5zj-84-fx_AazlxWmpn0oxLhwmKcqnJ8Yp28IQw0hhLO7ofPxUnZ-LDQi7igttlLKvczInDRO06S2vkhxj5EZlrxdW784uUVKNodzVKaNyEW0RdRiVdajEmXBxjK8HfDGNQipFQBdJGjmn-YfPdr0glIBcyI6Hw7aD0F9L8s2ByKwId34d7ETqyWfD1A7jh2324PadyH1Js24e7YQ2OhaNFD-En1RsHHu4r1tXMsK_Nis6LsFM667HEjBTbWvpFqzHsM7Zrrr1jUbwHG-RzZlrH-JydLrs-0Ftji5m9WDeh2ustm7XsaEsngFFpIvbX4t94tLTrlbFD__MoxtLj1bdmMA186Y_g7Pjoy_uTNCozpFZkuk-Vc0XtisxVJqtqK4WdmgJfjyqMz7n01mtTZ1PLpa7QB1JjTDQIZdSkqoT3BX8Me23X-qfAEHNxqRy3hdZi6jJttTGiVtapSlQTl0C6cU1pI205qWf8KDF9IVeWu65M4M1ofx4IO_5pebDxdBk_3Mvy9zBL4NV4Gz852kcxre_WZMMRxZJ-egJPwsAYu8IpEnOWXCagdobMaEB03rt32mY50Hrje0K0IJ_9_7Gewx3EbIOERVYcwF6_WvsXiIv66uUw-H8BvWIRHQ priority: 102 providerName: ProQuest |
Title | Reliability of a Virtual Prosthodontic Project Realized through a 2D and 3D Photographic Acquisition: An Experimental Study on the Accuracy of Different Digital Systems |
URI | https://www.ncbi.nlm.nih.gov/pubmed/31888225 https://www.proquest.com/docview/2329668737 https://www.proquest.com/docview/2331635414 https://pubmed.ncbi.nlm.nih.gov/PMC6950125 |
Volume | 16 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3fi9NAEB68O5ADEX-e0bOsIPgUbbq72a1wHPXaegh3lMNK38Jmd2MjR-rFFDz_Iv9MZ5K0tnq--BISMpOFnVnmm-zsNwAvZddpqZ0JIy4dJijKhaaHd7SDJ4SRxlja0T07j0-n4sNMzn7XP7UT-O3G1I76SU3Ly9ffr66PccEfUcaJKfub_IsvifG_JyTimR3Yw6ikaJGeifWOAsc4S1A4wngUYlRUDYHjDfr7cBv9HIEndc_ejFV_AdA_6yg3AtP4HtxtESUbNC5wH2754gHcaX7HseaU0UP4SaXHDSX3NVtkzLBPeUlHR9iEjn3MMTktUJ-e6McMu0C9_Id3rO3jgwq9ITOFY3zIJvNF1TBdo8bAXi3zpvDrLRsUbLTRMoBRlSKOV-BnPEraZWlsPf6w7ctS4d3nvBZtqNMfwXQ8-nhyGrZNGkIrIl2Fyrk4c3HkUhOlmZXC9k2MU6Ji43tceuu1yaK-5VKnaAKpMTwaRDWqm6bC-5g_ht1iUfgnwBB-cakct7HWou8ibbUxIlPWqVSkXRdAuDJHYlsGc2qkcZlgJkOWTLYtGcCrtfzXhrvjn5KHK-smKxdMEGtiLqgVVwG8WL_G1UdbKqbwiyXJcAS01Eo9gIPGGdZDrbwoALXlJmsBYvbeflPk85rhG-cJgYN8-t-az2AfkV3d6CKKD2G3Kpf-OaKnKu3AjpopvOqTiK7j9x3Yezc6n1x06gXzCxG7Iig |
linkProvider | Scholars Portal |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV3db9MwED-N8TAkhGB8FQYYCcRTtCSOYxcJoYpu6tiHJrShvgXHdmgQSrcuFRp_EU_8jdzFaWhB8LY3RznbUe58H_b5fgAvRGiVUFYHERcWAxRpAx1ji07wkkQLrQ2d6B4epaPT5P1YjNfg5-IuDKVVLnRio6jt1NAe-TZafvTMleTy7dl5QKhRdLq6gNDwYrHvLr9hyHbxZm-I_H0Zx7s7J-9GQYsqEJgkUnUgrU0Lm0Y211FeGJGYvk6dNTLVLubCGad0EfUNFyrH2FEo1OcazbAM8zxxLuU47jW4joY3pBUlx12Ax9GWk7sdoc0L0PJKXySS8364XX5xM0IliBMRETD5shH8y7P9M0FzyeLt3oZbravKBl627sCaqzZhY0jpRYQQtwk3_Z4f81eZ7sIPym_2db8v2bRgmn0sZ3Q_hR3T3ZIJRsDY19AT7f6wD9iv_O4sa8GCsEM8ZLqyjA_Z8WRa-3La2GNgzuelzy57zQYV21nCJWCUConzVTiMQ0ozn2nTzD9swV9qbH0uG1Jfn_0enF4Jz-7DejWt3ENg6ONxIS03qVJJ30bKKK2TQhor8yQPbQ-CBWsy05ZJJ7SOrxmGS8TKbJWVPXjV0Z_5AiH_pNxacDprFcVF9luse_C8e41LnM5tdOWmc6Lh6DUTXnsPHnjB6KZClYwxUix6IFdEpiOg8uGrb6py0pQRx_-E3ol49P_PegYbo5PDg-xg72j_MdxAf7GBz4jSLVivZ3P3BH2yOn_aLAQGn6565f0C6CpPpg |
linkToPdf | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1fb9MwED-NIQESQjD-FQYYCcRT1CaOYxcJoYqs2hhMFWKob5ljOzQIpVuXCo1PxGfg03EXp2EFwdveEuUujnJ3vjv7fD-AZ2JglVBWByEXFhMUaQMd4RXt4MWxFlob2tF9f5DsHsZvp2K6AT9XZ2GorHI1JzYTtZ0bWiPvo-fHyFxJLvtFWxYxScevj08CQpCindYVnIZXkX139g3Tt9NXeynK-nkUjXc-vtkNWoSBwMShqgNpbVLYJLS5DvPCiNgMdeKskYl2ERfOOKWLcGi4UDnmkULh3K7RJctBnsfOJRzfewkuSy5CsjE57ZI9jn6dQu8Q_V-AXlj6hpGcDwf98otbEEJBFCPbcN0h_hXl_lmsec77jW_CjTZsZSOvZ7dgw1VbcDWlUiNCi9uC6379j_ljTbfhB9U6-x7gZ2xeMM0-lQs6q8ImdM5khtkw8hq6o5Ug9gH5yu_OshY4CBmilOnKMp6yyWxe-9bayDEyJ8vSV5q9ZKOK7ZzDKGBUFonjVfgah5RmudCmGT9tgWBqvPpcNqS-V_sdOLwQmd2FzWpeufvAMN7jQlpuEqXioQ2VUVrHhTRW5nE-sD0IVqLJTNsynZA7vmaYOpEos3VR9uBFR3_sm4X8k3J7JemsnTROs98q3oOn3WM0d9rD0ZWbL4mGYwRN2O09uOcVoxsKp2fMlyLRA7mmMh0BtRJff1KVs6alOP4njFTEg_9_1hO4gjaXvds72H8I1zB0bJA0wmQbNuvF0j3C8KzOHzd2wODoog3vFyp4U9w |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Reliability+of+a+Virtual+Prosthodontic+Project+Realized+through+a+2D+and+3D+Photographic+Acquisition%3A+An+Experimental+Study+on+the+Accuracy+of+Different+Digital+Systems&rft.jtitle=International+journal+of+environmental+research+and+public+health&rft.au=Lavorgna%2C+Luca&rft.au=Cervino%2C+Gabriele&rft.au=Fiorillo%2C+Luca&rft.au=Di+Leo%2C+Giovanni&rft.date=2019-12-16&rft.pub=MDPI&rft.issn=1661-7827&rft.eissn=1660-4601&rft.volume=16&rft.issue=24&rft_id=info:doi/10.3390%2Fijerph16245139&rft_id=info%3Apmid%2F31888225&rft.externalDocID=PMC6950125 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1660-4601&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1660-4601&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1660-4601&client=summon |