Accuracy of PARTwear Inertial Sensor and Optojump Optical Measurement System for Measuring Ground Contact Time During Running
Ammann, R, Taube, W, and Wyss, T. Accuracy of PARTwear inertial sensor and Optojump optical measurement system for measuring ground contact time during running. J Strength Cond Res 30(7): 2057-2063, 2016-The aim of this study was to validate the detection of ground contact time (GCT) during running...
Saved in:
Published in | Journal of strength and conditioning research Vol. 30; no. 7; p. 2057 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
United States
01.07.2016
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Abstract | Ammann, R, Taube, W, and Wyss, T. Accuracy of PARTwear inertial sensor and Optojump optical measurement system for measuring ground contact time during running. J Strength Cond Res 30(7): 2057-2063, 2016-The aim of this study was to validate the detection of ground contact time (GCT) during running in 2 differently working systems: a small inertial measurement sensor, PARTwear (PW), worn on the shoe laces, and the optical measurement system, Optojump (OJ), placed on the track. Twelve well-trained subjects performed 12 runs each on an indoor track at speeds ranging from 3.0 to 9.0 m·s. GCT of one step per run (total 144) was simultaneously obtained by the PW, the OJ, and a high-speed video camera (HSC), whereby the latter served as reference system. The sampling rate was 1,000 Hz for all methods. Compared with the HSC, the PW and the OJ systems underestimated GCT by -1.3 ± 6.1% and -16.5 ± 6.7% (p-values ≤ 0.05), respectively. The intraclass correlation coefficients between PW and HSC and between OJ and HSC were 0.984 and 0.853 (p-values < 0.001), respectively. Despite the constant systematic underestimation of GCT, analyses indicated that PW successfully recorded GCT over a wide range of speeds. However, results showed only moderate validity for the OJ system, with increasing errors when speed decreased. In conclusion, the PW proved to be a highly useful and valid application, and its use can be recommended not only for laboratory settings but also for field applications. In contrast, data on GCT obtained by OJ during running must be treated with caution, specifically when running speed changes or when comparisons are made with GCT data collected by other measurement systems. |
---|---|
AbstractList | Ammann, R, Taube, W, and Wyss, T. Accuracy of PARTwear inertial sensor and Optojump optical measurement system for measuring ground contact time during running. J Strength Cond Res 30(7): 2057-2063, 2016-The aim of this study was to validate the detection of ground contact time (GCT) during running in 2 differently working systems: a small inertial measurement sensor, PARTwear (PW), worn on the shoe laces, and the optical measurement system, Optojump (OJ), placed on the track. Twelve well-trained subjects performed 12 runs each on an indoor track at speeds ranging from 3.0 to 9.0 m·s. GCT of one step per run (total 144) was simultaneously obtained by the PW, the OJ, and a high-speed video camera (HSC), whereby the latter served as reference system. The sampling rate was 1,000 Hz for all methods. Compared with the HSC, the PW and the OJ systems underestimated GCT by -1.3 ± 6.1% and -16.5 ± 6.7% (p-values ≤ 0.05), respectively. The intraclass correlation coefficients between PW and HSC and between OJ and HSC were 0.984 and 0.853 (p-values < 0.001), respectively. Despite the constant systematic underestimation of GCT, analyses indicated that PW successfully recorded GCT over a wide range of speeds. However, results showed only moderate validity for the OJ system, with increasing errors when speed decreased. In conclusion, the PW proved to be a highly useful and valid application, and its use can be recommended not only for laboratory settings but also for field applications. In contrast, data on GCT obtained by OJ during running must be treated with caution, specifically when running speed changes or when comparisons are made with GCT data collected by other measurement systems. |
Author | Wyss, Thomas Taube, Wolfgang Ammann, Rahel |
Author_xml | – sequence: 1 givenname: Rahel surname: Ammann fullname: Ammann, Rahel organization: 1Swiss Federal Institute of Sport Magglingen SFISM, Magglingen, Switzerland; and 2Department of Medicine, Movement and Sport Science, University of Fribourg, Fribourg, Switzerland – sequence: 2 givenname: Wolfgang surname: Taube fullname: Taube, Wolfgang – sequence: 3 givenname: Thomas surname: Wyss fullname: Wyss, Thomas |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/26677827$$D View this record in MEDLINE/PubMed |
BookMark | eNpNkM1OwzAQhC1URH_gDRDyC6TYThzbxypAKSoqasu52jprlKpxIicR6oF3J6ggsZcZ7bczhx2Tga88EnLL2ZRLbu5fNtmU_RsujLkgIy7jOEqEVoPeszSJNON8SMZNc2BMSCnjKzIUaaqUFmpEvmbWdgHsiVaOvs3W20-EQBceQ1vAkW7QN1Wg4HO6qtvq0JX1jylsz14Rmi5gib6lm1PTYkldf3teF_6DzkPV9cGs8i3Ylm6LEunDGa0773u9JpcOjg3e_OqEvD89brPnaLmaL7LZMrIJVybSLo0NxDnHxBnlpOaxdIZZJkwilbMG0EmmYQ-APePKCugDTnORWpuDmJC7c2_d7UvMd3UoSgin3d8fxDcjmmP- |
CitedBy_id | crossref_primary_10_1186_s40798_022_00477_0 crossref_primary_10_1177_1754337120977409 crossref_primary_10_3390_s18030873 crossref_primary_10_1080_14763141_2018_1452969 crossref_primary_10_1007_s40279_021_01443_8 crossref_primary_10_3389_fphys_2018_00610 crossref_primary_10_3390_app14125168 crossref_primary_10_1080_02640414_2024_2372940 crossref_primary_10_1123_jab_2016_0104 crossref_primary_10_1519_JSC_0000000000003008 crossref_primary_10_1080_24748668_2019_1657655 crossref_primary_10_1016_j_gaitpost_2019_07_123 crossref_primary_10_1519_JSC_0000000000004612 crossref_primary_10_1123_ijspp_2016_0746 crossref_primary_10_3390_s24072191 crossref_primary_10_3390_sports7090202 crossref_primary_10_1080_19424280_2021_1878287 crossref_primary_10_3390_s21217331 crossref_primary_10_1007_s40279_022_01760_6 crossref_primary_10_3390_children11010102 crossref_primary_10_3390_sports6010015 crossref_primary_10_3233_JIFS_189832 crossref_primary_10_3390_s20020354 |
ContentType | Journal Article |
DBID | CGR CUY CVF ECM EIF NPM |
DOI | 10.1519/JSC.0000000000001299 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
Discipline | Recreation & Sports |
EISSN | 1533-4287 |
ExternalDocumentID | 26677827 |
Genre | Validation Studies Journal Article Comparative Study |
GroupedDBID | -~X .Z2 01R 0R~ 123 186 29L 2FS 36B 40H 4R4 53G 5AM 5VS 6PF 7O~ 7RV 7X7 88E 88I 8AO 8C1 8FE 8FH 8FI 8FJ 8R4 8R5 9M8 AAAAV AAAXR AAGIX AAHPQ AAIQE AAJCS AAMOA AAQKA AARTV AASCR AAUEB AAWTL AAXQO ABASU ABBUW ABDIG ABJNI ABNJN ABPXF ABUWG ABVCZ ABXVJ ABXYN ABZAD ABZZY ACDDN ACDOF ACEWG ACGFO ACGFS ACGOD ACIFK ACILI ACJBD ACLDA ACPRK ACTAD ACTHT ACWDW ACWRI ACXJB ACXNZ ACZKN ADBBV ADBIZ ADEGP ADFPA ADGGA ADGHP ADHPY ADLEJ ADNKB ADNVM AEBDS AEETU AENEX AFBFQ AFDTB AFEXH AFKRA AFMBP AFNMH AFPHX AFSOK AFYGQ AGINI AHMBA AHOMT AHQNM AHQVU AHVBC AHWXW AIJEX AINUH AJCLO AJEOO AJIOK AJNWD AJNYG AJZMW AKCTQ AKULP ALIPV ALKUP ALMA_UNASSIGNED_HOLDINGS ALMTX AMJPA AMKUR AMNEI AOHHW AOQMC ATPOU AZQEC BBNVY BENPR BHPHI BKEYQ BKNYI BOYCO BPHCQ BQLVK BVXVI C45 CAG CCPQU CGR COF CUY CVF DIWNM DU5 DUNZO DWQXO D~A E.X EBS ECM EEVPB EIF EJD ERAAH EX3 FCALG FL- FYUFA GNUQQ GNXGY GQDEL HCIFZ HLJTE HMCUK HZ~ IKREB IKYAY IN~ IPNFZ IYOWL JK3 JK8 K8S K9- KD2 L-C LK8 M0R M1P M2P M7P MMDCI MPPUT NAPCQ NPM N~6 N~7 N~B O9- OBZCC OCUKA ODA ODMTH OGKNY OHT OHYEH OKBHI OLL OPUJH ORVUJ OUVQU OVD OVDLW OVDNE OVIDH OVLEI OVOZU OXXIT P2P PCD PHGZM PHGZT PJZUB PPXIY PQGLB PQQKQ PROAC PSQYO Q2X QMB R2J R58 RIG RLZ ROL RWF S4S SJN TEORI TSPGW TWG UAP UKHRP UKR UMD UPT V2I VJK W3M WF8 WH7 WOQ WOW X3V X3W XOL YQT YR5 YRY ZCA ZHY ZZMQN |
ID | FETCH-LOGICAL-c4179-8f639a3d1e4f97f58135f90c029457fc9aef508abaae81317c2a39af8126ccda2 |
ISSN | 1064-8011 |
IngestDate | Mon Jul 21 06:04:25 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 7 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c4179-8f639a3d1e4f97f58135f90c029457fc9aef508abaae81317c2a39af8126ccda2 |
PMID | 26677827 |
ParticipantIDs | pubmed_primary_26677827 |
PublicationCentury | 2000 |
PublicationDate | 2016-Jul |
PublicationDateYYYYMMDD | 2016-07-01 |
PublicationDate_xml | – month: 07 year: 2016 text: 2016-Jul |
PublicationDecade | 2010 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Journal of strength and conditioning research |
PublicationTitleAlternate | J Strength Cond Res |
PublicationYear | 2016 |
SSID | ssj0025553 |
Score | 2.314663 |
Snippet | Ammann, R, Taube, W, and Wyss, T. Accuracy of PARTwear inertial sensor and Optojump optical measurement system for measuring ground contact time during... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 2057 |
SubjectTerms | Accelerometry - instrumentation Adult Female Humans Light Male Running - physiology Videotape Recording |
Title | Accuracy of PARTwear Inertial Sensor and Optojump Optical Measurement System for Measuring Ground Contact Time During Running |
URI | https://www.ncbi.nlm.nih.gov/pubmed/26677827 |
Volume | 30 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9NAEF6l9MIFlZZXgWoOiAsy2LHXmz1GLVVBopX6EL1V6_VuK0ScCBIhkPhZ_L_OeGcdK7TikYNl7caO4-_T7MzsPIR4UXpdeVzHkgoXp6RQVZ6MrK2TsjZKZ1o5GQJkD8uDs-L9uTwfDH71opYW8-q1_XFjXsn_oIpjiCtlyf4Dst1NcQDPEV88IsJ4_CuMx9YuvlC_dgpkQ830G1XleddQqDQV-UALlUMkj2bz6ScEjk5aVD4sXYNctLyNNwzD0SeFF1LxKsqipEyRV3th6njRtjm6Ra2l5JPmskuYox1xdvlyXaHO_zyeTLhD87G5cstID7OoWi_rx-lnf2n4h2jd-P51NaaJ3RVZ2YW2RgmLOhAti2HIRambJ2S79cUyb9cE-qm-jE1DSevfhD8qo9TX-mQ3FKXkDyo0uv91hHA2aQmBuolCBUn9eXalJHecWhNraJxQt1VyEbGVL6UMWR38PzlfEx_uzU2PRtWo-XYrlk2r4ZxuiHuMIYwDz-6LgWs2xebSroCXcNJuMG2Jn5F5MPUQmQeReRCYB8gAiMwDZh70mAeBeYDMg455EJgHzDwg5kFgHjDzHoiz_benuwcJN_JILDW4S0Ye9WCT15krvFZejrJcep3adKgLqbzVxnk0FExljMO5TNmhwQs8Kp8lCg4zfCjuNNPGPRYwrH1Z2rTOVFYUde50nRqLICipnPZF_kQ8Cu_wYhaqtVzEt7t968xTcXfJ1Gdi3aN4cM9R15xXOy2214X4foQ |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Accuracy+of+PARTwear+Inertial+Sensor+and+Optojump+Optical+Measurement+System+for+Measuring+Ground+Contact+Time+During+Running&rft.jtitle=Journal+of+strength+and+conditioning+research&rft.au=Ammann%2C+Rahel&rft.au=Taube%2C+Wolfgang&rft.au=Wyss%2C+Thomas&rft.date=2016-07-01&rft.issn=1064-8011&rft.eissn=1533-4287&rft.volume=30&rft.issue=7&rft.spage=2057&rft_id=info:doi/10.1519%2FJSC.0000000000001299&rft_id=info%3Apmid%2F26677827&rft_id=info%3Apmid%2F26677827&rft.externalDocID=26677827 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1064-8011&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1064-8011&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1064-8011&client=summon |