Detection of Hepatocellular Carcinoma with Ferucarbotran (Resovist)-enhanced Breath-hold MR Imaging: Feasibility of 10 minute-delayed Images

Purpose: We evaluated the optimal timing for breath-hold MR imaging with bolus-injectable superparamagnetic iron oxide (SPIO) for detecting hepatocellular carcinoma (HCC). Materials and Methods: Twenty patients with 62 HCCs (52 hypervascular, 10 non-hypervascular) underwent MR imaging that included...

Full description

Saved in:
Bibliographic Details
Published inMagnetic Resonance in Medical Sciences Vol. 7; no. 3; pp. 123 - 130
Main Authors SAITO, Kazuhiro, SHINDO, Hiroaki, OZUKI, Taizo, ISHIKAWA, Aimi, KOTAKE, Fumio, SHIMAZAKI, Yoko, ABE, Kimihiko
Format Journal Article
LanguageEnglish
Published Japan Japanese Society for Magnetic Resonance in Medicine 2008
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose: We evaluated the optimal timing for breath-hold MR imaging with bolus-injectable superparamagnetic iron oxide (SPIO) for detecting hepatocellular carcinoma (HCC). Materials and Methods: Twenty patients with 62 HCCs (52 hypervascular, 10 non-hypervascular) underwent MR imaging that included unenhanced and SPIO-enhanced T1-weighted gradient echo (GRE) and T2-weighted fast spin echo (FSE) sequences, perfusion study, and SPIO-enhanced T2*-weighted GRE sequences. We obtained SPIO-enhanced T2*-weighted sequences 10 and 30 min after injecting SPIO and made 2 image sets, comprising 10- or 30-min delayed T2*-weighted images. Three observers performed alternative free response receiver operating characteristic (AFROC) analysis, and quantitative evaluation was performed. Results: Only Observers 2 and 3 recognized a significant difference in the area under the AFROC curve (Az) value in the 10-min delayed images; no significant difference was observed in the 30-min delayed images. There was no significant difference in the sensitivity of individual observers between 10- and 30-min delayed images. The contrast-to-noise (C/N) ratio of the 30-min delayed images was significantly higher than that of the 10-min delayed images. The C/N ratio of hypervascular HCCs in the 30-min delayed images was significantly higher than in the 10-min delayed images, but that of non-hypervascular HCCs showed no significant difference. Conclusion: In most cases, 10-min delayed SPIO-enhanced T2*-weighted images are sufficient to detect HCCs.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1347-3182
1880-2206
DOI:10.2463/mrms.7.123