To determine the values for the anterior best-fit sphere (BFS) and posterior BFS in an Asian population using the Orbscan II (Bausch & Lomb) slit-scanning Placido disk corneal topographer. Hospital-based refractive surgery center. This prospective nonrandomized study comprised of 1 eye of 724 su...

Full description

Saved in:
Bibliographic Details
Published inJournal of cataract and refractive surgery Vol. 32; no. 11; pp. 1814 - 1819
Main Authors Lim, Kooi-Ling, Fam, Han-Bor
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.11.2006
Subjects
Online AccessGet full text
ISSN0886-3350
1873-4502
DOI10.1016/j.jcrs.2006.08.022

Cover

Loading…
Abstract To determine the values for the anterior best-fit sphere (BFS) and posterior BFS in an Asian population using the Orbscan II (Bausch & Lomb) slit-scanning Placido disk corneal topographer. Hospital-based refractive surgery center. This prospective nonrandomized study comprised of 1 eye of 724 subjects. The eyes were measured with the Orbscan II. Default settings were used to generate relative elevation maps. Anterior BFS, posterior BFS, mean keratometry (K mean), spherical equivalent (SE), horizontal white-to-white size (WTW), and anterior chamber depth (ACD) were analyzed. The mean spherical equivalent (SE) in the 724 eyes was −5.32 diopters (D) ± 2.88 (SD). The anterior BFS and posterior BFS were normally distributed, with a mean of 43.05 ± 1.37 D and 52.43 ± 2.03 D, respectively. The regression equation of anterior BFS and posterior BFS was posterior BFS = 0.443 + 1.208 anterior BFS ( r 2 = 0.667, P<.01). The ratio of posterior BFS to anterior BFS was 1.22 ± 0.03. The anterior BFS was significantly correlated to posterior BFS ( P<.01), K mean ( P<.01), and horizontal WTW ( P<.01) but not to SE ( P = .28). The posterior BFS was significantly correlated to K mean ( P<.01) and the horizontal WTW ( P<.01) but not to SE ( P = .70). There was a close relationship between the various corneal parameters, which is significant in refractive surgery and intraocular lens calculation and design.
AbstractList To determine the values for the anterior best-fit sphere (BFS) and posterior BFS in an Asian population using the Orbscan II (Bausch & Lomb) slit-scanning Placido disk corneal topographer. Hospital-based refractive surgery center. This prospective nonrandomized study comprised of 1 eye of 724 subjects. The eyes were measured with the Orbscan II. Default settings were used to generate relative elevation maps. Anterior BFS, posterior BFS, mean keratometry (K mean), spherical equivalent (SE), horizontal white-to-white size (WTW), and anterior chamber depth (ACD) were analyzed. The mean spherical equivalent (SE) in the 724 eyes was −5.32 diopters (D) ± 2.88 (SD). The anterior BFS and posterior BFS were normally distributed, with a mean of 43.05 ± 1.37 D and 52.43 ± 2.03 D, respectively. The regression equation of anterior BFS and posterior BFS was posterior BFS = 0.443 + 1.208 anterior BFS ( r 2 = 0.667, P<.01). The ratio of posterior BFS to anterior BFS was 1.22 ± 0.03. The anterior BFS was significantly correlated to posterior BFS ( P<.01), K mean ( P<.01), and horizontal WTW ( P<.01) but not to SE ( P = .28). The posterior BFS was significantly correlated to K mean ( P<.01) and the horizontal WTW ( P<.01) but not to SE ( P = .70). There was a close relationship between the various corneal parameters, which is significant in refractive surgery and intraocular lens calculation and design.
To determine the values for the anterior best-fit sphere (BFS) and posterior BFS in an Asian population using the Orbscan II (Bausch & Lomb) slit-scanning Placido disk corneal topographer.PURPOSETo determine the values for the anterior best-fit sphere (BFS) and posterior BFS in an Asian population using the Orbscan II (Bausch & Lomb) slit-scanning Placido disk corneal topographer.Hospital-based refractive surgery center.SETTINGHospital-based refractive surgery center.This prospective nonrandomized study comprised of 1 eye of 724 subjects. The eyes were measured with the Orbscan II. Default settings were used to generate relative elevation maps. Anterior BFS, posterior BFS, mean keratometry (K(mean)), spherical equivalent (SE), horizontal white-to-white size (WTW), and anterior chamber depth (ACD) were analyzed.METHODSThis prospective nonrandomized study comprised of 1 eye of 724 subjects. The eyes were measured with the Orbscan II. Default settings were used to generate relative elevation maps. Anterior BFS, posterior BFS, mean keratometry (K(mean)), spherical equivalent (SE), horizontal white-to-white size (WTW), and anterior chamber depth (ACD) were analyzed.The mean spherical equivalent (SE) in the 724 eyes was -5.32 diopters (D) +/- 2.88 (SD). The anterior BFS and posterior BFS were normally distributed, with a mean of 43.05 +/- 1.37 D and 52.43 +/- 2.03 D, respectively. The regression equation of anterior BFS and posterior BFS was posterior BFS = 0.443 + 1.208 anterior BFS (r(2) = 0.667, P<.01). The ratio of posterior BFS to anterior BFS was 1.22 +/- 0.03. The anterior BFS was significantly correlated to posterior BFS (P<.01), K(mean) (P<.01), and horizontal WTW (P<.01) but not to SE (P = .28). The posterior BFS was significantly correlated to K(mean) (P<.01) and the horizontal WTW (P<.01) but not to SE (P = .70).RESULTSThe mean spherical equivalent (SE) in the 724 eyes was -5.32 diopters (D) +/- 2.88 (SD). The anterior BFS and posterior BFS were normally distributed, with a mean of 43.05 +/- 1.37 D and 52.43 +/- 2.03 D, respectively. The regression equation of anterior BFS and posterior BFS was posterior BFS = 0.443 + 1.208 anterior BFS (r(2) = 0.667, P<.01). The ratio of posterior BFS to anterior BFS was 1.22 +/- 0.03. The anterior BFS was significantly correlated to posterior BFS (P<.01), K(mean) (P<.01), and horizontal WTW (P<.01) but not to SE (P = .28). The posterior BFS was significantly correlated to K(mean) (P<.01) and the horizontal WTW (P<.01) but not to SE (P = .70).There was a close relationship between the various corneal parameters, which is significant in refractive surgery and intraocular lens calculation and design.CONCLUSIONThere was a close relationship between the various corneal parameters, which is significant in refractive surgery and intraocular lens calculation and design.
To determine the values for the anterior best-fit sphere (BFS) and posterior BFS in an Asian population using the Orbscan II (Bausch & Lomb) slit-scanning Placido disk corneal topographer. Hospital-based refractive surgery center. This prospective nonrandomized study comprised of 1 eye of 724 subjects. The eyes were measured with the Orbscan II. Default settings were used to generate relative elevation maps. Anterior BFS, posterior BFS, mean keratometry (K(mean)), spherical equivalent (SE), horizontal white-to-white size (WTW), and anterior chamber depth (ACD) were analyzed. The mean spherical equivalent (SE) in the 724 eyes was -5.32 diopters (D) +/- 2.88 (SD). The anterior BFS and posterior BFS were normally distributed, with a mean of 43.05 +/- 1.37 D and 52.43 +/- 2.03 D, respectively. The regression equation of anterior BFS and posterior BFS was posterior BFS = 0.443 + 1.208 anterior BFS (r(2) = 0.667, P<.01). The ratio of posterior BFS to anterior BFS was 1.22 +/- 0.03. The anterior BFS was significantly correlated to posterior BFS (P<.01), K(mean) (P<.01), and horizontal WTW (P<.01) but not to SE (P = .28). The posterior BFS was significantly correlated to K(mean) (P<.01) and the horizontal WTW (P<.01) but not to SE (P = .70). There was a close relationship between the various corneal parameters, which is significant in refractive surgery and intraocular lens calculation and design.
Author Fam, Han-Bor
Lim, Kooi-Ling
Author_xml – sequence: 1
  givenname: Kooi-Ling
  surname: Lim
  fullname: Lim, Kooi-Ling
  email: kooiling@ilasercentre.com
– sequence: 2
  givenname: Han-Bor
  surname: Fam
  fullname: Fam, Han-Bor
BackLink https://www.ncbi.nlm.nih.gov/pubmed/17081863$$D View this record in MEDLINE/PubMed
BookMark eNqFkE9v1DAQRy1URLeFL8AB-cQtYWLHjrfisqr4J1VCQnC2nMmEesnawfYW9duT7RaBeiinkUbv_Q7vjJ2EGIixlw3UDTT6zbbeYsq1ANA1mBqEeMJWjelk1SoQJ2wFxuhKSgWn7CznLQC0Qqpn7LTpwDRGyxWjLzS54mPI137mPZVfRIGXa-IYUyA38bxPo0PiLgx3fxcKJR8Tz_R9R6HwOP7DX_BN4JvsXeAzpTwTFn9Dz9nT0U2ZXtzfc_bt_buvlx-rq88fPl1uripsQZVKa4eyFw7WY9eqDgSttSLsuxEHXCtaGweEQskOcBicwL6VrpfCNVoIRUqes9fH3TnFn3vKxe58RpomFyjus9WmAb0ML-Cre3Df72iwc_I7l27tnzALII4ApphzovEvAvZQ327tob491Ldg7FJ_kcwDCX25q1uS89Pj6tujSkueG0_JZvQUkAafloZ2iP5x_eKBjpMPHt30g27_J_8G45S0rQ
CitedBy_id crossref_primary_10_1111_j_1475_1313_2010_00732_x
crossref_primary_10_1097_ICU_0b013e3281ca7121
crossref_primary_10_1016_j_clae_2013_02_007
crossref_primary_10_1016_j_jcrs_2009_06_031
crossref_primary_10_1097_ICU_0b013e3282887e1e
crossref_primary_10_1016_j_jcrs_2012_06_048
crossref_primary_10_1097_ICO_0b013e3181fb4fa7
crossref_primary_10_1016_j_jcrs_2017_02_027
crossref_primary_10_1007_s10792_014_0005_y
crossref_primary_10_1016_j_jcrs_2006_11_023
crossref_primary_10_1155_2020_7395081
crossref_primary_10_1371_journal_pone_0122441
crossref_primary_10_1016_j_jcrs_2007_09_033
crossref_primary_10_1117_1_3578461
crossref_primary_10_3928_1081597X_20090917_03
crossref_primary_10_1097_ICO_0b013e31824d0e40
crossref_primary_10_1371_journal_pone_0207710
Cites_doi 10.1111/j.1475-1313.2004.00268.x
10.1016/j.visres.2004.11.002
10.1111/j.1755-3768.1994.tb04687.x
10.1016/S0161-6420(99)90153-7
10.1016/S0886-3350(13)80395-1
10.1034/j.1600-0420.2002.800406.x
10.1016/j.ophtha.2005.11.004
10.3928/1081-597X-20000501-07
10.1167/iovs.04-1324
10.1016/S0161-6420(00)00224-4
10.1016/S0161-6420(00)00159-7
10.1097/01.opx.0000177804.53192.15
10.1136/bjo.2005.071118
10.1097/00006324-198205000-00011
10.1016/j.jcrs.2004.12.061
10.1016/j.jcrs.2004.09.047
10.1016/j.jcrs.2005.12.002
10.1016/S0886-3350(03)00409-7
10.1016/S0161-6420(00)00152-4
10.1097/00055735-200502000-00011
10.1097/00006324-199707000-00016
10.1097/00006324-199010000-00002
ContentType Journal Article
Copyright 2006 ASCRS and ESCRS
Copyright_xml – notice: 2006 ASCRS and ESCRS
DBID AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
7X8
DOI 10.1016/j.jcrs.2006.08.022
DatabaseName CrossRef
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
MEDLINE - Academic
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
MEDLINE - Academic
DatabaseTitleList
MEDLINE - Academic
MEDLINE

Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1873-4502
EndPage 1819
ExternalDocumentID 17081863
10_1016_j_jcrs_2006_08_022
S0886335006010625
Genre Journal Article
GroupedDBID ---
--K
.1-
.FO
.GJ
0R~
1B1
1P~
1~5
29K
4.4
457
4G.
53G
5GY
5VS
7-5
AAAAV
AAEDT
AAEDW
AAGIX
AAHPQ
AAIQE
AALRI
AAQFI
AAQKA
AAQQT
AAQXK
AASCR
AAXUO
ABASU
ABDIG
ABIID
ABJNI
ABLJU
ABMAC
ABPXF
ABVCZ
ABWVN
ABZZY
ACGFO
ACGFS
ACILI
ACIUM
ACLDA
ACRPL
ACVFH
ACXJB
ACZKN
ADBBV
ADCNI
ADGGA
ADHPY
ADMUD
ADNMO
ADSXY
AEETU
AENEX
AEUPX
AEVXI
AFBFQ
AFDTB
AFPUW
AFRHN
AFTJW
AGQPQ
AHOMT
AHQNM
AIGII
AINUH
AITUG
AJCLO
AJIOK
AJNWD
AJUYK
AJZMW
AKCTQ
AKRWK
AKULP
ALKUP
ALMA_UNASSIGNED_HOLDINGS
ALMTX
AMJPA
AMKUR
AMNEI
AMRAJ
AOQMC
ASPBG
AVWKF
AZFZN
BELOY
C45
C5W
CS3
D-I
DIWNM
DU5
EBS
EEVPB
EJD
ERAAH
F5P
FCALG
FDB
FEDTE
FGOYB
GBLVA
GNXGY
GQDEL
HLJTE
HVGLF
HZ~
IHE
IKREB
IKYAY
J1W
K-O
KOM
L7B
M41
MO0
NQ-
O9-
OF-
OPF
OQ~
OVD
P2P
R2-
RLZ
ROL
RPZ
SEL
SES
SJN
SSZ
TEORI
TSPGW
UHS
UV1
XH2
XPP
Z5R
ZGI
ZXP
ZZMQN
ADPAM
AFCTW
AGZHU
ALXNB
RIG
ZA5
AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
7X8
ID FETCH-LOGICAL-c405t-66ac3b2a09f745702e965ecb7fcdc95e98a0ec25370cdda2cb43ab32a16225e53
ISSN 0886-3350
IngestDate Fri Jul 11 11:08:26 EDT 2025
Fri Jun 06 19:40:25 EDT 2025
Tue Jul 01 03:17:20 EDT 2025
Thu Apr 24 23:13:23 EDT 2025
Fri Feb 23 02:23:07 EST 2024
Tue Aug 26 16:34:53 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 11
Language English
License https://www.elsevier.com/tdm/userlicense/1.0
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c405t-66ac3b2a09f745702e965ecb7fcdc95e98a0ec25370cdda2cb43ab32a16225e53
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
PMID 17081863
PQID 68106570
PQPubID 23479
PageCount 6
ParticipantIDs proquest_miscellaneous_68106570
pubmed_primary_17081863
crossref_primary_10_1016_j_jcrs_2006_08_022
crossref_citationtrail_10_1016_j_jcrs_2006_08_022
elsevier_sciencedirect_doi_10_1016_j_jcrs_2006_08_022
elsevier_clinicalkey_doi_10_1016_j_jcrs_2006_08_022
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2006-11-01
PublicationDateYYYYMMDD 2006-11-01
PublicationDate_xml – month: 11
  year: 2006
  text: 2006-11-01
  day: 01
PublicationDecade 2000
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Journal of cataract and refractive surgery
PublicationTitleAlternate J Cataract Refract Surg
PublicationYear 2006
Publisher Elsevier Inc
Publisher_xml – name: Elsevier Inc
References Cairns, McGhee (bib14) 2005; 31
Rabsilber, Becker, Frisch, Auffarth (bib27) 2003; 29
Rüfer, Schröder, Erb (bib25) 2005; 24
Binder, Lindstrom, Stulting (bib7) 2005; 31
Wei, Lim, Chan, Tan (bib8) 2006; 113
Horner, Salmon, Soni (bib22) 1998
Atchison, Smith (bib20) 2000
Klyce, Smolek (bib1) 1993; 19
Alessio, Boscia, La Tegola, Sborgia (bib5) 2000; 107
Horner, Salmon, Soni (bib13) 1998
Turner (bib3) 2001
Lo, Ho, Lau (bib30) 1996; 12
Hashemi, Yazdani, Mehravaran, Fotouhi (bib26) 2005; 82
Saw, Chua, Gazzard (bib32) 2005; 89
Allouch, Touzeau, Borderie (bib29) 2001; 24
Garner, Owens, Yap (bib16) 1997; 74
Findl (bib12) 2005; 16
Lackner, Schmidinger, Skorpik (bib28) 2005; 82
Ojaimi, Rose, Morgan (bib9) 2005; 46
Howland (bib10) 2005; 45
Knorz, Neuhann (bib4) 2000; 107
Norrby (bib21) 2005; 25
Wang, Chen, Yang (bib6) 1999; 106
Norrby, Lydahl, Koranyi, Taube (bib11) 2005; 31
Edmund (bib18) 1994; 72
Tomidokoro, Oshika, Amano (bib2) 2000; 107
Dubbelman, Weeber, van der Heijde, Völker-Dieben (bib19) 2002; 80
Wilson (bib15) 2000; 107
Martin, Holden (bib24) 1982; 59
Seitz, Langenbucher, Nguyen (bib23) 1999; 106
Royston, Dunne, Barnes (bib17) 1990; 67
Hosny, Alió, Claramonte (bib31) 2000; 16
Ojaimi (R9-7-20210210) 2005; 46
Howland (R10-7-20210210) 2005; 45
Norrby (R21-7-20210210) 2005; 25
Cairns (R14-7-20210210) 2005; 31
Hosny (R31-7-20210210) 2000; 16
Tomidokoro (R2-7-20210210) 2000; 107
Allouch (R29-7-20210210) 2001; 24
Wei (R8-7-20210210) 2006; 113
Hashemi (R26-7-20210210) 2005; 82
Norrby (R11-7-20210210) 2005; 31
Wilson (R15-7-20210210) 2000; 107
Findl (R12-7-20210210) 2005; 16
Binder (R7-7-20210210) 2005; 31
Martin (R24-7-20210210) 1982; 59
Lo (R30-7-20210210) 1996; 12
Dubbelman (R19-7-20210210) 2002; 80
Rabsilber (R27-7-20210210) 2003; 29
Lackner (R28-7-20210210) 2005; 82
Royston (R17-7-20210210) 1990; 67
Seitz (R23-7-20210210) 1999; 106
Saw (R32-7-20210210) 2005; 89
Garner (R16-7-20210210) 1997; 74
Klyce (R1-7-20210210) 1993; 19
Edmund (R18-7-20210210) 1994; 72
Alessio (R5-7-20210210) 2000; 107
Rufer (R25-7-20210210) 2005; 24
References_xml – volume: 16
  start-page: 336
  year: 2000
  end-page: 340
  ident: bib31
  article-title: Relationship between anterior chamber depth, refractive state, corneal diameter, and axial length
  publication-title: J Refract Surg
– volume: 107
  start-page: 1328
  year: 2000
  end-page: 1332
  ident: bib2
  article-title: Changes in anterior and posterior corneal curvatures in keratoconus
  publication-title: Ophthalmology
– volume: 106
  start-page: 406
  year: 1999
  end-page: 409
  ident: bib6
  article-title: Posterior corneal surface topographic changes after laser in situ keratomileusis are related to residual corneal bed thickness
  publication-title: Ophthalmology
– volume: 89
  start-page: 1489
  year: 2005
  end-page: 1494
  ident: bib32
  article-title: Eye growth changes in myopic children in Singapore
  publication-title: Br J Ophthalmol
– volume: 31
  start-page: 205
  year: 2005
  end-page: 220
  ident: bib14
  article-title: Orbscan computerized topography: attributes, applications, and limitations
  publication-title: J Cataract Refract Surg
– volume: 29
  start-page: 2115
  year: 2003
  end-page: 2121
  ident: bib27
  article-title: Anterior chamber depth in relation to refractive status measured with the Orbscan II Topography System
  publication-title: J Cataract Refract Surg
– start-page: 221
  year: 2001
  end-page: 227
  ident: bib3
  article-title: What corneal topography can tell you about corneal shape
  publication-title: Customized Corneal Ablation; the Quest for SuperVision
– volume: 59
  start-page: 436
  year: 1982
  end-page: 441
  ident: bib24
  article-title: A new method for measuring the diameter of the in vivo human cornea
  publication-title: Am J Optom Physiol Opt
– volume: 24
  start-page: 710
  year: 2001
  end-page: 715
  ident: bib29
  article-title: Biométrie oculaire à l'aide d'une fente lumineuse (Orbscan
  publication-title: J Fr Ophtalmol
– volume: 46
  start-page: 2748
  year: 2005
  end-page: 2754
  ident: bib9
  article-title: Distribution of ocular biometric parameters and refraction in a population-based study of Australian children
  publication-title: Invest Ophthalmol Vis Sci
– volume: 82
  start-page: 900
  year: 2005
  end-page: 904
  ident: bib26
  article-title: Anterior chamber depth measurement with a-scan ultrasonography, Orbscan II, and IOLMaster
  publication-title: Optom Vis Sci
– volume: 82
  start-page: 858
  year: 2005
  end-page: 861
  ident: bib28
  article-title: Validity and repeatability of anterior chamber depth measurements with Pentacam and Orbscan
  publication-title: Optom Vis Sci
– volume: 107
  start-page: 1578
  year: 2000
  end-page: 1587
  ident: bib5
  article-title: Topography-driven photorefractive keratectomy; results of corneal interactive programmed topographic ablation software
  publication-title: Ophthalmology
– volume: 113
  start-page: 177
  year: 2006
  end-page: 183
  ident: bib8
  article-title: Evaluation of Orbscan II corneal topography in individuals with myopia
  publication-title: Ophthalmology
– volume: 107
  start-page: 1223
  year: 2000
  ident: bib15
  article-title: Cautions regarding measurements of the posterior corneal curvature
  publication-title: Ophthalmology
– volume: 12
  start-page: 121
  year: 1996
  end-page: 125
  ident: bib30
  article-title: [Relationship between myopia and study and optical components-a study among Chinese Hong Kong student population]
  publication-title: Yen Ko Hsueh Pao
– start-page: 524
  year: 1998
  end-page: 558
  ident: bib13
  article-title: Corneal topography
  publication-title: Borish's Clinical Refraction
– volume: 16
  start-page: 61
  year: 2005
  end-page: 64
  ident: bib12
  article-title: Biometry and intraocular lens power calculation
  publication-title: Curr Opin Ophthalmol
– volume: 80
  start-page: 379
  year: 2002
  end-page: 383
  ident: bib19
  article-title: Radius and asphericity of the posterior corneal surface determined by corrected Scheimpflug photography
  publication-title: Acta Ophthalmol Scand
– volume: 31
  start-page: 2035
  year: 2005
  end-page: 2037
  ident: bib7
  article-title: Keratoconus and corneal ectasia after LASIK
  publication-title: J Cataract Refract Surg
– volume: 72
  start-page: 715
  year: 1994
  end-page: 720
  ident: bib18
  article-title: Posterior corneal curvature and its influence on corneal dioptric power
  publication-title: Acta Ophthalmol (Copenh)
– volume: 19
  start-page: 122
  year: 1993
  end-page: 130
  ident: bib1
  article-title: Corneal topography of excimer laser photorefractive keratectomy
  publication-title: J Cataract Refract Surg
– volume: 67
  start-page: 757
  year: 1990
  end-page: 763
  ident: bib17
  article-title: Measurement of posterior corneal surface toricity
  publication-title: Optom Vis Sci
– start-page: 524
  year: 1998
  end-page: 558
  ident: bib22
  article-title: Corneal topography
  publication-title: Borish's Clinical Refraction
– volume: 24
  start-page: 259
  year: 2005
  end-page: 261
  ident: bib25
  article-title: White-to-white corneal diameter; normal values in healthy humans obtained with the Orbscan II topography system
  publication-title: Cornea
– volume: 74
  start-page: 496
  year: 1997
  end-page: 498
  ident: bib16
  article-title: Radius of curvature of the posterior surface of the cornea
  publication-title: Optom Vis Sci
– volume: 45
  start-page: 1091
  year: 2005
  end-page: 1093
  ident: bib10
  article-title: Allometry and scaling of wave aberration of eyes
  publication-title: Vision Res
– volume: 31
  start-page: 1338
  year: 2005
  end-page: 1344
  ident: bib11
  article-title: Clinical application of the lens haptic plane concept with transformed axial lengths
  publication-title: J Cataract Refract Surg
– year: 2000
  ident: bib20
  article-title: Optics of the Human Eye
– volume: 107
  start-page: 2072
  year: 2000
  end-page: 2076
  ident: bib4
  article-title: Treatment of myopia and myopic astigmatism by customized laser in situ keratomileusis based on corneal topography
  publication-title: Ophthalmology
– volume: 106
  start-page: 693
  year: 1999
  end-page: 702
  ident: bib23
  article-title: Underestimation of intraocular lens power for cataract surgery after myopic photorefractive keratectomy
  publication-title: Ophthalmology
– volume: 25
  start-page: 153
  year: 2005
  end-page: 161
  ident: bib21
  article-title: The Dubbelman eye model analysed by ray tracing through aspheric surfaces
  publication-title: Ophthalmic Physiol Opt
– volume: 24
  start-page: 710
  year: 2001
  ident: R29-7-20210210
  article-title: Biometrie oculaire a laide dune fente lumineuse (Orbscan).
  publication-title: J Fr Ophtalmol
– volume: 25
  start-page: 153
  year: 2005
  ident: R21-7-20210210
  article-title: The Dubbelman eye model analysed by ray tracing through aspheric surfaces.
  publication-title: Ophthalmic Physiol Opt
  doi: 10.1111/j.1475-1313.2004.00268.x
– volume: 45
  start-page: 1091
  year: 2005
  ident: R10-7-20210210
  article-title: Allometry and scaling of wave aberration of eyes.
  publication-title: Vision Res
  doi: 10.1016/j.visres.2004.11.002
– volume: 72
  start-page: 715
  year: 1994
  ident: R18-7-20210210
  article-title: Posterior corneal curvature and its influence on corneal dioptric power.
  publication-title: Acta Ophthalmol (Copenh)
  doi: 10.1111/j.1755-3768.1994.tb04687.x
– volume: 106
  start-page: 693
  year: 1999
  ident: R23-7-20210210
  article-title: Underestimation of intraocular lens power for cataract surgery after myopic photorefractive keratectomy.
  publication-title: Ophthalmology
  doi: 10.1016/S0161-6420(99)90153-7
– volume: 19
  start-page: 122
  year: 1993
  ident: R1-7-20210210
  article-title: Corneal topography of excimer laser photorefractive keratectomy.
  publication-title: J Cataract Refract Surg
  doi: 10.1016/S0886-3350(13)80395-1
– volume: 80
  start-page: 379
  year: 2002
  ident: R19-7-20210210
  article-title: Radius and asphericity of the posterior corneal surface determined by corrected Scheimpflug photography.
  publication-title: Acta Ophthalmol Scand
  doi: 10.1034/j.1600-0420.2002.800406.x
– volume: 113
  start-page: 177
  year: 2006
  ident: R8-7-20210210
  article-title: Evaluation of Orbscan II corneal topography in individuals with myopia.
  publication-title: Ophthalmology
  doi: 10.1016/j.ophtha.2005.11.004
– volume: 16
  start-page: 336
  year: 2000
  ident: R31-7-20210210
  article-title: Relationship between anterior chamber depth, refractive state, corneal diameter, and axial length.
  publication-title: J Refract Surg
  doi: 10.3928/1081-597X-20000501-07
– volume: 46
  start-page: 2748
  year: 2005
  ident: R9-7-20210210
  article-title: Distribution of ocular biometric parameters and refraction in a population-based study of Australian children.
  publication-title: Invest Ophthalmol Vis Sci
  doi: 10.1167/iovs.04-1324
– volume: 107
  start-page: 1578
  year: 2000
  ident: R5-7-20210210
  article-title: Topography-driven photorefractive keratectomy; results of corneal interactive programmed topographic ablation software.
  publication-title: Ophthalmology
  doi: 10.1016/S0161-6420(00)00224-4
– volume: 107
  start-page: 1328
  year: 2000
  ident: R2-7-20210210
  article-title: Changes in anterior and posterior corneal curvatures in keratoconus.
  publication-title: Ophthalmology
  doi: 10.1016/S0161-6420(00)00159-7
– volume: 82
  start-page: 858
  year: 2005
  ident: R28-7-20210210
  article-title: Validity and repeatability of anterior chamber depth measurements with Pentacam and Orbscan.
  publication-title: Optom Vis Sci
  doi: 10.1097/01.opx.0000177804.53192.15
– volume: 89
  start-page: 1489
  year: 2005
  ident: R32-7-20210210
  article-title: Eye growth changes in myopic children in Singapore.
  publication-title: Br J Ophthalmol
  doi: 10.1136/bjo.2005.071118
– volume: 59
  start-page: 436
  year: 1982
  ident: R24-7-20210210
  article-title: A new method for measuring the diameter ofthe in vivo human cornea.
  publication-title: Am J Optom Physiol Opt
  doi: 10.1097/00006324-198205000-00011
– volume: 31
  start-page: 1338
  year: 2005
  ident: R11-7-20210210
  article-title: Clinical application of the lens haptic plane concept with transformed axial lengths.
  publication-title: J Cataract Refract Surg
  doi: 10.1016/j.jcrs.2004.12.061
– volume: 31
  start-page: 205
  year: 2005
  ident: R14-7-20210210
  article-title: Orbscan computerized topography: attributes, applications, and limitations.
  publication-title: J Cataract Refract Surg
  doi: 10.1016/j.jcrs.2004.09.047
– volume: 31
  start-page: 2035
  year: 2005
  ident: R7-7-20210210
  article-title: Keratoconus and corneal ectasia after LASIK letter.
  publication-title: J Cataract Refract Surg
  doi: 10.1016/j.jcrs.2005.12.002
– volume: 29
  start-page: 2115
  year: 2003
  ident: R27-7-20210210
  article-title: Anterior chamber depth in relation to refractive status measured with the Orbscan II Topography System.
  publication-title: J Cataract Refract Surg
  doi: 10.1016/S0886-3350(03)00409-7
– volume: 24
  start-page: 259
  year: 2005
  ident: R25-7-20210210
  article-title: White-to-white corneal diameter; normal values in healthy humans obtained with the Orbscan II topography system.
  publication-title: Cornea
– volume: 82
  start-page: 900
  year: 2005
  ident: R26-7-20210210
  article-title: Anterior chamber depth measurement with a-scan ultrasonography, Orbscan II, and IOLMaster.
  publication-title: Optom Vis Sci
– volume: 107
  start-page: 1223
  year: 2000
  ident: R15-7-20210210
  article-title: Cautions regarding measurements of the posterior corneal curvature editorial.
  publication-title: Ophthalmology
  doi: 10.1016/S0161-6420(00)00152-4
– volume: 12
  start-page: 121
  year: 1996
  ident: R30-7-20210210
  article-title: Relationship between myopia and study and optical components-a study among Chinese Hong Kong student population Chinese.
  publication-title: Yen Ko Hsueh Pao
– volume: 16
  start-page: 61
  year: 2005
  ident: R12-7-20210210
  article-title: Biometry and intraocular lens power calculation.
  publication-title: Curr Opin Ophthalmol
  doi: 10.1097/00055735-200502000-00011
– volume: 74
  start-page: 496
  year: 1997
  ident: R16-7-20210210
  article-title: Radius of curvature of the posterior surface of the cornea.
  publication-title: Optom Vis Sci
  doi: 10.1097/00006324-199707000-00016
– volume: 67
  start-page: 757
  year: 1990
  ident: R17-7-20210210
  article-title: Measurement of posterior corneal surface toricity.
  publication-title: Optom Vis Sci
  doi: 10.1097/00006324-199010000-00002
SSID ssj0004235
Score 1.9197004
Snippet To determine the values for the anterior best-fit sphere (BFS) and posterior BFS in an Asian population using the Orbscan II (Bausch & Lomb) slit-scanning...
SourceID proquest
pubmed
crossref
elsevier
SourceType Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage 1814
SubjectTerms Adolescent
Adult
Anterior Eye Segment - anatomy & histology
Asian Continental Ancestry Group - ethnology
Cornea - anatomy & histology
Corneal Topography - methods
Female
Humans
Male
Middle Aged
Prospective Studies
Reference Values
Title Relationship between the corneal surface and the anterior segment of the cornea: An Asian perspective
URI https://www.clinicalkey.com/#!/content/1-s2.0-S0886335006010625
https://dx.doi.org/10.1016/j.jcrs.2006.08.022
https://www.ncbi.nlm.nih.gov/pubmed/17081863
https://www.proquest.com/docview/68106570
Volume 32
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3JbtswECXaBCh6CdLdSRceegtkSCRFWb25RQujbnooEjQ3gaSoIkYqGbKdQ76-w01SAztdLoJBkZKg90wOR_NmEHrLeFImWpqYqkxFDBaESMoJi2IJlhyVTMa22MTpVz47Z58v0os-oYJVl6zlWN1s1ZX8D6rQBrgalew_INtdFBrgN-ALR0AYjn-FcRfJNoy4MpYkbClrkzF4tWkr4SUBpt2-xsumPVnpHyEKoO_vnYRTq6tc_q7C3GLAGs-P0Vi5EHVdWb3VtTY37ZTWJtTH1WueN81l9CUslDb9o22fiTp637S3vA9J530IkxTgTF3y2DCj9h7LTVCV-PkR7Am2deJ2PoTFeKHalf9ENBnHTrI8QHL500KZZDYTH-0XsS60MJy6j_YJ7Bxgrt6fzr99n_diWeKqroYH90oqF_R3-_Ymp6y_4C7DZdfGxBooZ4fowAODp44mj9A9XT9GD0597MQTpIdswZ4tGNDHni3YswUDnrY9sAV7tuCmGvR_h6c1tlzBA648ReefPp59mEW-yEakwFZfR5wLRSURcV5lLM1ionOeaiWzSpUqT3U-EbFWJKVZrMpSECUZFZISkXBYCnRKn6G9uqn1C4TBmq5MxceclynLNZ0oDrshZlwMJBExH6EkvMFC-Qz0phDKVRFCDReFAcCURuWFqY5KyAiddGOWLv_Knb1pAKYIymJYCwtg2Z2j0m6UtzudPfnHcW8C9gVMyuZLm6h1s1kVJsmfiSkboeeOEv2zezYd7TxzjB72f7SXaG_dbvQrMHzX8rWn8i8uMatM
linkProvider Library Specific Holdings
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Relationship+between+the+corneal+surface+and+the+anterior+segment+of+the+cornea%3A+An+Asian+perspective&rft.jtitle=Journal+of+cataract+and+refractive+surgery&rft.au=Lim%2C+Kooi-Ling&rft.au=Fam%2C+Han-Bor&rft.date=2006-11-01&rft.issn=0886-3350&rft.volume=32&rft.issue=11&rft.spage=1814&rft_id=info:doi/10.1016%2Fj.jcrs.2006.08.022&rft_id=info%3Apmid%2F17081863&rft.externalDocID=17081863
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0886-3350&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0886-3350&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0886-3350&client=summon