The elusive half-pole in the frequency domain transfer function of Peltier thermoelectric devices

A half-pole can be expected in the transfer function of a Peltier device because proportionality between the diffusion length and the square root of the diffusion time is intrinsic in the diffusion equation. The resulting -1∕2 bilogarithmic slope (10 dB∕dec) is, however, easily masked by the thermal...

Full description

Saved in:
Bibliographic Details
Published inReview of scientific instruments Vol. 82; no. 3; p. 034901
Main Authors De Marchi, Andrea, Giaretto, Valter
Format Journal Article
LanguageEnglish
Published United States 01.03.2011
Online AccessGet more information

Cover

Loading…
Abstract A half-pole can be expected in the transfer function of a Peltier device because proportionality between the diffusion length and the square root of the diffusion time is intrinsic in the diffusion equation. The resulting -1∕2 bilogarithmic slope (10 dB∕dec) is, however, easily masked by the thermal time constant of the load, which makes it elusive. The goal of this work is to identify the arrangements which can reveal and make usable the half-pole, because the latter can be instrumental in a servo control to increase the open-loop gain without risking instability. The diffusion equation was solved in a sine wave regime for a one-dimensional model of a Peltier device. The Laplace transform method was used, and the periodic solution was obtained using Cauchy's theorem and the method of residues. The -1∕2 slope of the half-pole appeared observable in a frequency range which can be several decades wide, depending on details of device configuration and considered position within. Amplitude and phase of temperature and heat flux in various spots are discussed with emphasis on the physical meaning, and a comparison is provided with solutions yielded by the lumped model, which cannot show the half-pole. An experimental check of the theoretical approach and analysis was made taking into account the deviations from one-dimensionality occurring in a real Peltier device. Given a constant amplitude sine wave injected current, the quadrature component of the Seebeck voltage across the whole series of junctions was identified as the most easily measurable quantity related to the thermal response of the device. Experimental results for the latter turned out in good agreement with analytical solutions.
AbstractList A half-pole can be expected in the transfer function of a Peltier device because proportionality between the diffusion length and the square root of the diffusion time is intrinsic in the diffusion equation. The resulting -1∕2 bilogarithmic slope (10 dB∕dec) is, however, easily masked by the thermal time constant of the load, which makes it elusive. The goal of this work is to identify the arrangements which can reveal and make usable the half-pole, because the latter can be instrumental in a servo control to increase the open-loop gain without risking instability. The diffusion equation was solved in a sine wave regime for a one-dimensional model of a Peltier device. The Laplace transform method was used, and the periodic solution was obtained using Cauchy's theorem and the method of residues. The -1∕2 slope of the half-pole appeared observable in a frequency range which can be several decades wide, depending on details of device configuration and considered position within. Amplitude and phase of temperature and heat flux in various spots are discussed with emphasis on the physical meaning, and a comparison is provided with solutions yielded by the lumped model, which cannot show the half-pole. An experimental check of the theoretical approach and analysis was made taking into account the deviations from one-dimensionality occurring in a real Peltier device. Given a constant amplitude sine wave injected current, the quadrature component of the Seebeck voltage across the whole series of junctions was identified as the most easily measurable quantity related to the thermal response of the device. Experimental results for the latter turned out in good agreement with analytical solutions.
Author Giaretto, Valter
De Marchi, Andrea
Author_xml – sequence: 1
  givenname: Andrea
  surname: De Marchi
  fullname: De Marchi, Andrea
  organization: Dipartimento di Elettronica, Politecnico di Torino, C.so Duca degli Abruzzi, 24-10129 Torino, Italy
– sequence: 2
  givenname: Valter
  surname: Giaretto
  fullname: Giaretto, Valter
BackLink https://www.ncbi.nlm.nih.gov/pubmed/21456778$$D View this record in MEDLINE/PubMed
BookMark eNo1T8tKAzEUDaLYhy78AckPTE0m76UUrUJBF3Vd8rihkZlMzcwU-veOqGdz4LzgLNBl7jIgdEfJihLJHuiKCaGlkRdoTok2lZI1m6FF33-SCYLSazSrKRdSKT1HdncADM3YpxPgg21idewawCnjYTJiga8Rsj_j0LX2Ryw29xEKjmP2Q-oy7iJ-h2ZIkzY1SttBA34oyeMAp-Shv0FX0TY93P7xEn08P-3WL9X2bfO6ftxWnhMxVMI6Y6zSkukgnVDMSh2DtM4ZX1NGAo_GRM6l0QK4rJVikwnETjkfnKiX6P539zi6FsL-WFJry3n__7X-BsnBVjU
CitedBy_id crossref_primary_10_35848_1347_4065_ac1f48
crossref_primary_10_1063_1_5040181
crossref_primary_10_7567_APEX_10_115801
crossref_primary_10_1063_1_5079832
crossref_primary_10_1007_s11664_018_06922_9
crossref_primary_10_1063_1_4901213
crossref_primary_10_1063_5_0196012
crossref_primary_10_7567_JJAP_55_126601
crossref_primary_10_1016_j_apenergy_2018_05_041
crossref_primary_10_1063_1_3656074
crossref_primary_10_1063_5_0045108
crossref_primary_10_1007_s11664_015_4271_x
crossref_primary_10_1063_1_4897189
crossref_primary_10_1063_5_0124602
crossref_primary_10_1007_s11664_013_2530_2
crossref_primary_10_1063_1_4789765
crossref_primary_10_1038_s41598_022_15947_4
crossref_primary_10_1007_s11664_016_4839_0
ContentType Journal Article
DBID NPM
DOI 10.1063/1.3558696
DatabaseName PubMed
DatabaseTitle PubMed
DatabaseTitleList PubMed
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Sciences (General)
EISSN 1089-7623
ExternalDocumentID 21456778
Genre Journal Article
GroupedDBID ---
-DZ
-~X
.DC
.GJ
0ZJ
123
186
1UP
2-P
29P
3O-
4.4
41~
53G
5RE
5VS
6TJ
85S
9M8
A9.
AAAAW
AABDS
AAEUA
AAPUP
AAYIH
AAYJJ
ABFTF
ABJNI
ACBEA
ACBRY
ACGFO
ACGFS
ACKIV
ACLYJ
ACNCT
ACZLF
ADCTM
ADIYS
ADRHT
AEGXH
AEJMO
AENEX
AFATG
AFFNX
AFHCQ
AGKCL
AGLKD
AGMXG
AGTJO
AHPGS
AHSDT
AIAGR
AJJCW
AJQPL
ALEPV
ALMA_UNASSIGNED_HOLDINGS
AQWKA
ATXIE
AWQPM
BDMKI
BPZLN
CS3
DU5
EBS
EJD
ESX
F20
F5P
FDOHQ
FFFMQ
HAM
L7B
M43
M6X
M71
M73
MVM
N9A
NEJ
NEUPN
NHB
NPM
NPSNA
O-B
OHT
P2P
QZG
RDFOP
RIP
RNS
ROL
RQS
TAE
TN5
UAO
UHB
VQA
WH7
XJT
XOL
XSW
YNT
YZZ
ZCG
ZXP
~02
ID FETCH-LOGICAL-c405t-5ab99a78638d6b573a68fd6abb9c2130d4f99f446985e4627736abe0aa68cdb52
IngestDate Sat Sep 28 07:51:32 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 3
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c405t-5ab99a78638d6b573a68fd6abb9c2130d4f99f446985e4627736abe0aa68cdb52
PMID 21456778
ParticipantIDs pubmed_primary_21456778
PublicationCentury 2000
PublicationDate 2011-03-01
PublicationDateYYYYMMDD 2011-03-01
PublicationDate_xml – month: 03
  year: 2011
  text: 2011-03-01
  day: 01
PublicationDecade 2010
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Review of scientific instruments
PublicationTitleAlternate Rev Sci Instrum
PublicationYear 2011
SSID ssj0000511
Score 2.13361
Snippet A half-pole can be expected in the transfer function of a Peltier device because proportionality between the diffusion length and the square root of the...
SourceID pubmed
SourceType Index Database
StartPage 034901
Title The elusive half-pole in the frequency domain transfer function of Peltier thermoelectric devices
URI https://www.ncbi.nlm.nih.gov/pubmed/21456778
Volume 82
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1NT9tAEF3xceFSkQItFKo9cKCKHILtXdvHqqJFSESoShA3tJ9qpCSOgjnAr-_M7tqYAIL2YkW7cRT5PY_frmfeEHKoTkycataPtGAcFijaRgKwjkysmEoyyTNXX3Ex4Gej9PyaXS9Vl1Sypx5erCv5H1RhDHDFKtl_QLb5URiAz4AvHAFhOL4bYzO5cxnof8TERnPMFQyZi3bhs6Tvu7qcChx0GtUsuvgsq4XipZlUWHCCOnBa-qY4Y4W1VBhB2tL1d1Pk4osoMccIU9krtF8IhlBOEmM3I3w90eRLNpH_1xh76rrGTd0r956-velw0sq66hkfKPt5EUEgTdqRNI9bjElaYRFNcPzpzyI2SCTcPOihzTv3zW1byM2nDjq0U0enu7dnl8yz66lVsprlGAYHuJlTP6hBbNZmUzw5bv6DM4j25y0tNpzoGG6SD2G1QL976Dtkxcw-kk6Ix7f0KJiGf9siArhAAxdowwU6nlFAljZcoJ4LtOYCrblAS0sDF-hTLtDAhW0y-nk6_HEWhfYZkQIVXkVMyKIQWQ4RVnPJskTw3GoupCxUDNJFp7YobIotRJlJeZxlCUyavoDvKS1ZvEPWZuXMfCYU1pWSG4XNzfJUmaQAVa0zaznc0UzFbJd88pfpZu49Um7qC7j36swXsvHIrH2ybuGmNAeg8Cr51eH0F5wXU_Y
link.rule.ids 783
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=The+elusive+half-pole+in+the+frequency+domain+transfer+function+of+Peltier+thermoelectric+devices&rft.jtitle=Review+of+scientific+instruments&rft.au=De+Marchi%2C+Andrea&rft.au=Giaretto%2C+Valter&rft.date=2011-03-01&rft.eissn=1089-7623&rft.volume=82&rft.issue=3&rft.spage=034901&rft_id=info:doi/10.1063%2F1.3558696&rft_id=info%3Apmid%2F21456778&rft_id=info%3Apmid%2F21456778&rft.externalDocID=21456778