Deep learning for improving ZTE MRI images in free breathing

Despite a growing interest in lung MRI, its broader use in a clinical setting remains challenging. Several factors limit the image quality of lung MRI, such as the extremely short T2 and T2* relaxation times of the lung parenchyma and cardiac and breathing motion. Zero Echo Time (ZTE) sequences are...

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance imaging Vol. 98; pp. 97 - 104
Main Authors Papp, D., Castillo T, Jose M., Wielopolski, P.A., Ciet, P., Veenland, Jifke F., Kotek, G., Hernandez-Tamames, J.
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier Inc 01.05.2023
Subjects
Online AccessGet full text

Cover

Loading…
Abstract Despite a growing interest in lung MRI, its broader use in a clinical setting remains challenging. Several factors limit the image quality of lung MRI, such as the extremely short T2 and T2* relaxation times of the lung parenchyma and cardiac and breathing motion. Zero Echo Time (ZTE) sequences are sensitive to short T2 and T2* species paving the way to improved “CT-like” MR images. To overcome this limitation, a retrospective respiratory gated version of ZTE (ZTE4D) which can obtain images in 16 different respiratory phases during free breathing was developed. Initial performance of ZTE4D have shown motion artifacts. To improve image quality, deep learning with fully convolutional neural networks (FCNNs) has been proposed. CNNs has been widely used for MR imaging, but it has not been used for improving free-breathing lung imaging yet. Our proposed pipeline facilitates the clinical work with patients showing difficulties/uncapable to perform breath-holding, or when the different gating techniques are not efficient due to the irregular respiratory pace. After signed informed consent and IRB approval, ZTE4D free breathing and breath-hold ZTE3D images were obtained from 10 healthy volunteers on a 1.5 T MRI scanner (GE Healthcare Signa Artist, Waukesha, WI). ZTE4D acquisition captured all 16 phases of the respiratory cycle. For the ZTE breath-hold, the subjects were instructed to hold their breath in 5 different inflation levels ranging from full expiration to full inspiration. The training dataset consisting of ZTE-BH images of 10 volunteers was split into 8 volunteers for training, 1 for validation and 1 for testing. In total 800 ZTE breath-hold images were constructed by adding Gaussian noise and performing image transformations (translations, rotations) to imitate the effect of motion in the respiratory cycle, and blurring from varying diaphragm positions, as it appears for ZTE4D. These sets were used to train a FCNN model to remove the artificially added noise and transformations from the ZTE breath-hold images and reproduce the original quality of the images. Mean squared error (MSE) was used as loss function. The remaining 2 healthy volunteer's ZTE4D images were used to test the model and qualitatively assess the predicted images. Our model obtained a MSE of 0.09% on the training set and 0.135% on the validation set. When tested on unseen data the predicted images from our model improved the contrast of the pulmonary parenchyma against air filled regions (airways or air trapping). The SNR of the lung parenchyma was quantitatively improved by a factor of 1.98 and the CNR lung- blood, which is indicating the visibility of the intrapulmonary vessels, was improved by 4.2%. Our network was able to reduce ghosting artifacts, such as diaphragm movement and blurring, and enhancing image quality. Free-breathing 3D and 4D lung imaging with MRI is feasible, however its quality is not yet acceptable for clinical use. This can be improved with deep learning techniques. Our FCNN improves the visual image quality and reduces artifacts of free-breathing ZTE4D. Our main goal was rather to remove ghosting artifacts from the ZTE4D images, to improve diagnostic quality of the images. As main results of the network, diaphragm contour increased with sharper edges by visual inspection and less blurring of the anatomical structures and lung parenchyma. With FCNNs, image quality of free breathing ZTE4D lung MRI can be improved and enable better visualization of the lung parenchyma in different respiratory phases.
AbstractList Despite a growing interest in lung MRI, its broader use in a clinical setting remains challenging. Several factors limit the image quality of lung MRI, such as the extremely short T2 and T2* relaxation times of the lung parenchyma and cardiac and breathing motion. Zero Echo Time (ZTE) sequences are sensitive to short T2 and T2* species paving the way to improved "CT-like" MR images. To overcome this limitation, a retrospective respiratory gated version of ZTE (ZTE4D) which can obtain images in 16 different respiratory phases during free breathing was developed. Initial performance of ZTE4D have shown motion artifacts. To improve image quality, deep learning with fully convolutional neural networks (FCNNs) has been proposed. CNNs has been widely used for MR imaging, but it has not been used for improving free-breathing lung imaging yet. Our proposed pipeline facilitates the clinical work with patients showing difficulties/uncapable to perform breath-holding, or when the different gating techniques are not efficient due to the irregular respiratory pace. After signed informed consent and IRB approval, ZTE4D free breathing and breath-hold ZTE3D images were obtained from 10 healthy volunteers on a 1.5 T MRI scanner (GE Healthcare Signa Artist, Waukesha, WI). ZTE4D acquisition captured all 16 phases of the respiratory cycle. For the ZTE breath-hold, the subjects were instructed to hold their breath in 5 different inflation levels ranging from full expiration to full inspiration. The training dataset consisting of ZTE-BH images of 10 volunteers was split into 8 volunteers for training, 1 for validation and 1 for testing. In total 800 ZTE breath-hold images were constructed by adding Gaussian noise and performing image transformations (translations, rotations) to imitate the effect of motion in the respiratory cycle, and blurring from varying diaphragm positions, as it appears for ZTE4D. These sets were used to train a FCNN model to remove the artificially added noise and transformations from the ZTE breath-hold images and reproduce the original quality of the images. Mean squared error (MSE) was used as loss function. The remaining 2 healthy volunteer's ZTE4D images were used to test the model and qualitatively assess the predicted images. Our model obtained a MSE of 0.09% on the training set and 0.135% on the validation set. When tested on unseen data the predicted images from our model improved the contrast of the pulmonary parenchyma against air filled regions (airways or air trapping). The SNR of the lung parenchyma was quantitatively improved by a factor of 1.98 and the CNR lung- blood, which is indicating the visibility of the intrapulmonary vessels, was improved by 4.2%. Our network was able to reduce ghosting artifacts, such as diaphragm movement and blurring, and enhancing image quality. Free-breathing 3D and 4D lung imaging with MRI is feasible, however its quality is not yet acceptable for clinical use. This can be improved with deep learning techniques. Our FCNN improves the visual image quality and reduces artifacts of free-breathing ZTE4D. Our main goal was rather to remove ghosting artifacts from the ZTE4D images, to improve diagnostic quality of the images. As main results of the network, diaphragm contour increased with sharper edges by visual inspection and less blurring of the anatomical structures and lung parenchyma. With FCNNs, image quality of free breathing ZTE4D lung MRI can be improved and enable better visualization of the lung parenchyma in different respiratory phases.
INTRODUCTIONDespite a growing interest in lung MRI, its broader use in a clinical setting remains challenging. Several factors limit the image quality of lung MRI, such as the extremely short T2 and T2* relaxation times of the lung parenchyma and cardiac and breathing motion. Zero Echo Time (ZTE) sequences are sensitive to short T2 and T2* species paving the way to improved "CT-like" MR images. To overcome this limitation, a retrospective respiratory gated version of ZTE (ZTE4D) which can obtain images in 16 different respiratory phases during free breathing was developed. Initial performance of ZTE4D have shown motion artifacts. To improve image quality, deep learning with fully convolutional neural networks (FCNNs) has been proposed. CNNs has been widely used for MR imaging, but it has not been used for improving free-breathing lung imaging yet. Our proposed pipeline facilitates the clinical work with patients showing difficulties/uncapable to perform breath-holding, or when the different gating techniques are not efficient due to the irregular respiratory pace. MATERIALS AND METHODSAfter signed informed consent and IRB approval, ZTE4D free breathing and breath-hold ZTE3D images were obtained from 10 healthy volunteers on a 1.5 T MRI scanner (GE Healthcare Signa Artist, Waukesha, WI). ZTE4D acquisition captured all 16 phases of the respiratory cycle. For the ZTE breath-hold, the subjects were instructed to hold their breath in 5 different inflation levels ranging from full expiration to full inspiration. The training dataset consisting of ZTE-BH images of 10 volunteers was split into 8 volunteers for training, 1 for validation and 1 for testing. In total 800 ZTE breath-hold images were constructed by adding Gaussian noise and performing image transformations (translations, rotations) to imitate the effect of motion in the respiratory cycle, and blurring from varying diaphragm positions, as it appears for ZTE4D. These sets were used to train a FCNN model to remove the artificially added noise and transformations from the ZTE breath-hold images and reproduce the original quality of the images. Mean squared error (MSE) was used as loss function. The remaining 2 healthy volunteer's ZTE4D images were used to test the model and qualitatively assess the predicted images. RESULTSOur model obtained a MSE of 0.09% on the training set and 0.135% on the validation set. When tested on unseen data the predicted images from our model improved the contrast of the pulmonary parenchyma against air filled regions (airways or air trapping). The SNR of the lung parenchyma was quantitatively improved by a factor of 1.98 and the CNR lung- blood, which is indicating the visibility of the intrapulmonary vessels, was improved by 4.2%. Our network was able to reduce ghosting artifacts, such as diaphragm movement and blurring, and enhancing image quality. DISCUSSIONFree-breathing 3D and 4D lung imaging with MRI is feasible, however its quality is not yet acceptable for clinical use. This can be improved with deep learning techniques. Our FCNN improves the visual image quality and reduces artifacts of free-breathing ZTE4D. Our main goal was rather to remove ghosting artifacts from the ZTE4D images, to improve diagnostic quality of the images. As main results of the network, diaphragm contour increased with sharper edges by visual inspection and less blurring of the anatomical structures and lung parenchyma. CONCLUSIONWith FCNNs, image quality of free breathing ZTE4D lung MRI can be improved and enable better visualization of the lung parenchyma in different respiratory phases.
Author Veenland, Jifke F.
Kotek, G.
Papp, D.
Castillo T, Jose M.
Ciet, P.
Wielopolski, P.A.
Hernandez-Tamames, J.
Author_xml – sequence: 1
  givenname: D.
  surname: Papp
  fullname: Papp, D.
  email: d.papp@erasmusmc.nl
  organization: Department of Radiology and Nuclear Medicine, Erasmus Medical Centre, Rotterdam, the Netherlands
– sequence: 2
  givenname: Jose M.
  surname: Castillo T
  fullname: Castillo T, Jose M.
  organization: Department of Radiology and Nuclear Medicine, Erasmus Medical Centre, Rotterdam, the Netherlands
– sequence: 3
  givenname: P.A.
  surname: Wielopolski
  fullname: Wielopolski, P.A.
  organization: Department of Radiology and Nuclear Medicine, Erasmus Medical Centre, Rotterdam, the Netherlands
– sequence: 4
  givenname: P.
  surname: Ciet
  fullname: Ciet, P.
  organization: Department of Radiology and Nuclear Medicine, Erasmus Medical Centre, Rotterdam, the Netherlands
– sequence: 5
  givenname: Jifke F.
  surname: Veenland
  fullname: Veenland, Jifke F.
  organization: Department of Radiology and Nuclear Medicine, Erasmus Medical Centre, Rotterdam, the Netherlands
– sequence: 6
  givenname: G.
  surname: Kotek
  fullname: Kotek, G.
  organization: Department of Radiology and Nuclear Medicine, Erasmus Medical Centre, Rotterdam, the Netherlands
– sequence: 7
  givenname: J.
  surname: Hernandez-Tamames
  fullname: Hernandez-Tamames, J.
  organization: Department of Radiology and Nuclear Medicine, Erasmus Medical Centre, Rotterdam, the Netherlands
BackLink https://www.ncbi.nlm.nih.gov/pubmed/36681310$$D View this record in MEDLINE/PubMed
BookMark eNp9kE1LAzEQhoNU7If-AC-yRy9bJ8ludoNepNYPqAhSQbyENDupKe1uTbYF_70prR6FgWGGZ17eefukUzc1EnJOYUiBiqvFcOXdkAHjQ6Cx5BHp0bLgaV7KrEN6UHBIC5a_d0k_hAUA5IznJ6TLhSgpp9AjN3eI62SJ2teunie28YlbrX2z3U0f03Hy_PoUN3qOIXF1Yj1iMvOo288InJJjq5cBzw59QN7ux9PRYzp5eXga3U5Sw6VoU6FZLqnNoCiZzioQQmRVZjlIYDmX0mpqS1ZpU2AhMcOqEtYaizbTnIPJ-IBc7nWjsa8NhlatXDC4XOoam01QrBAl47IQPKJ0jxrfhODRqrWP9v23oqB2oamFiqGpXWgKaCwZby4O8pvZCqu_i9-UInC9BzA-uXXoVTAOa4OV82haVTXuH_kf_Mt9Kg
CitedBy_id crossref_primary_10_1002_jmri_29388
Cites_doi 10.1002/jmri.25776
10.1109/ACCESS.2019.2908685
10.1016/j.rcl.2013.04.007
10.1002/jmri.21183
10.1148/radiology.180.3.1871305
10.1007/s00330-018-5889-x
10.1016/j.neuroimage.2006.01.015
10.1016/j.mric.2019.01.002
10.1002/ppul.23266
10.1148/radiology.160.3.3737921
10.1016/S0140-6736(12)60815-0
10.1007/s00330-020-06890-x
10.1007/s00247-015-3420-y
10.1259/bjr.20170037
10.1118/1.595711
10.3348/kjr.2019.0312
ContentType Journal Article
Copyright 2023 The Authors
Copyright © 2023 The Authors. Published by Elsevier Inc. All rights reserved.
Copyright_xml – notice: 2023 The Authors
– notice: Copyright © 2023 The Authors. Published by Elsevier Inc. All rights reserved.
DBID 6I.
AAFTH
CGR
CUY
CVF
ECM
EIF
NPM
AAYXX
CITATION
7X8
DOI 10.1016/j.mri.2023.01.019
DatabaseName ScienceDirect Open Access Titles
Elsevier:ScienceDirect:Open Access
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
CrossRef
MEDLINE - Academic
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
CrossRef
MEDLINE - Academic
DatabaseTitleList MEDLINE

MEDLINE - Academic
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1873-5894
EndPage 104
ExternalDocumentID 10_1016_j_mri_2023_01_019
36681310
S0730725X23000206
Genre Journal Article
GroupedDBID ---
--K
--M
.1-
.FO
.GJ
.~1
0R~
1B1
1P~
1RT
1~.
1~5
29M
3O-
4.4
457
4CK
4G.
53G
5GY
5RE
5VS
6I.
7-5
71M
8P~
9JM
9JN
AABNK
AACTN
AAEDT
AAEDW
AAFTH
AAIAV
AAIKJ
AAKOC
AALRI
AAOAW
AAQFI
AAQXK
AAXUO
ABBQC
ABFNM
ABGSF
ABJNI
ABLVK
ABMAC
ABMZM
ABNEU
ABOCM
ABUDA
ABXDB
ABYKQ
ACDAQ
ACFVG
ACGFS
ACIUM
ACNNM
ACRLP
ADBBV
ADEZE
ADMUD
ADUVX
AEBSH
AEHWI
AEKER
AENEX
AEVXI
AFCTW
AFFNX
AFKWA
AFRHN
AFTJW
AFXIZ
AGHFR
AGRDE
AGUBO
AGYEJ
AHHHB
AIEXJ
AIKHN
AITUG
AIVDX
AJBFU
AJOXV
AJRQY
AJUYK
ALMA_UNASSIGNED_HOLDINGS
AMFUW
AMRAJ
ANZVX
ASPBG
AVWKF
AXJTR
AZFZN
BKOJK
BLXMC
BNPGV
CS3
DOVZS
EBS
EFJIC
EFLBG
EJD
EO8
EO9
EP2
EP3
F5P
FDB
FEDTE
FGOYB
FIRID
FNPLU
FYGXN
G-2
G-Q
G8K
GBLVA
HEI
HMK
HMO
HVGLF
HZ~
IHE
J1W
KOM
LCYCR
M29
M41
MO0
N9A
O-L
O9-
OAUVE
OGIMB
OI~
OU0
OZT
P-8
P-9
P2P
PC.
Q38
R2-
RIG
ROL
RPZ
SAE
SCC
SDF
SDG
SDP
SEL
SES
SEW
SPC
SPCBC
SSH
SSQ
SSU
SSZ
T5K
WUQ
XPP
Z5R
ZGI
ZMT
~G-
~S-
AAXKI
AFJKZ
AKRWK
CGR
CUY
CVF
ECM
EIF
NPM
AAYXX
CITATION
7X8
ID FETCH-LOGICAL-c396t-6a2591f40782a4d06664d4f309025399fa1f82dac7e79e4edd6ffcfef4a330c43
IEDL.DBID .~1
ISSN 0730-725X
IngestDate Fri Oct 25 05:57:03 EDT 2024
Thu Sep 26 15:45:59 EDT 2024
Sat Sep 28 08:18:58 EDT 2024
Fri Feb 23 02:37:21 EST 2024
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Keywords Zero TE
Magnetic resonance imaging
Lung
Fully convolutional neural networks
Language English
License This is an open access article under the CC BY license.
Copyright © 2023 The Authors. Published by Elsevier Inc. All rights reserved.
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c396t-6a2591f40782a4d06664d4f309025399fa1f82dac7e79e4edd6ffcfef4a330c43
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
OpenAccessLink https://www.sciencedirect.com/science/article/pii/S0730725X23000206
PMID 36681310
PQID 2768239763
PQPubID 23479
PageCount 8
ParticipantIDs proquest_miscellaneous_2768239763
crossref_primary_10_1016_j_mri_2023_01_019
pubmed_primary_36681310
elsevier_sciencedirect_doi_10_1016_j_mri_2023_01_019
PublicationCentury 2000
PublicationDate May 2023
2023-05-00
20230501
PublicationDateYYYYMMDD 2023-05-01
PublicationDate_xml – month: 05
  year: 2023
  text: May 2023
PublicationDecade 2020
PublicationPlace Netherlands
PublicationPlace_xml – name: Netherlands
PublicationTitle Magnetic resonance imaging
PublicationTitleAlternate Magn Reson Imaging
PublicationYear 2023
Publisher Elsevier Inc
Publisher_xml – name: Elsevier Inc
References Bergin, Glover, Pauly (bb0020) Sep. 1991; 180
Long, Shelhamer, Darrell (bb0065) Jun. 2015
Bae (bb0055) Sep. 2020; 30
Macdougall, Strauss, Lee (bb0025) Jul. 2013; 51
Souza, Frayne (bb0090) Oct. 2019
Iwasawa (bb0110) Dec. 2007; 26
Liszewski, Ciet, Lee (bb0005) May 2019; 27
Do, Song, Chung (bb0060) Jan. 2020; 21
(bb0100) 2022
Henkelman (bb0080) Apr. 1985; 12
Han, Duan, Tao, Lu (bb0075) 2019; 7
Pearce (bb0030) Aug. 2012; 380
Bae (bb0040) May 2019; 29
Ouahabi (bb0085) May 2013
Yushkevich (bb0105) Jul. 2006; 31
Kumar (bb0050) Dec. 2017; 90
Nayak, Ojha (bb0115) 2020
Lewis, Prato, Drost, Nicholson (bb0045) Sep. 1986; 160
Simonyan, Zisserman (bb0070) Apr. 10, 2015
Zucker, Cheng, Haldipur, Carl, Vasanawala (bb0015) Jan. 2018; 47
Ciet (bb0035) 2015; 45
Souza (bb0095) Sep. 14, 2022
Tiddens (bb0010) Oct. 2015; 50
Tiddens (10.1016/j.mri.2023.01.019_bb0010) 2015; 50
Bae (10.1016/j.mri.2023.01.019_bb0040) 2019; 29
Ouahabi (10.1016/j.mri.2023.01.019_bb0085) 2013
Liszewski (10.1016/j.mri.2023.01.019_bb0005) 2019; 27
Do (10.1016/j.mri.2023.01.019_bb0060) 2020; 21
Macdougall (10.1016/j.mri.2023.01.019_bb0025) 2013; 51
Kumar (10.1016/j.mri.2023.01.019_bb0050) 2017; 90
Yushkevich (10.1016/j.mri.2023.01.019_bb0105) 2006; 31
Ciet (10.1016/j.mri.2023.01.019_bb0035) 2015; 45
Bergin (10.1016/j.mri.2023.01.019_bb0020) 1991; 180
Pearce (10.1016/j.mri.2023.01.019_bb0030) 2012; 380
Bae (10.1016/j.mri.2023.01.019_bb0055) 2020; 30
Long (10.1016/j.mri.2023.01.019_bb0065) 2015
Simonyan (10.1016/j.mri.2023.01.019_bb0070)
Lewis (10.1016/j.mri.2023.01.019_bb0045) 1986; 160
Souza (10.1016/j.mri.2023.01.019_bb0095)
Iwasawa (10.1016/j.mri.2023.01.019_bb0110) 2007; 26
Henkelman (10.1016/j.mri.2023.01.019_bb0080) 1985; 12
Zucker (10.1016/j.mri.2023.01.019_bb0015) 2018; 47
Han (10.1016/j.mri.2023.01.019_bb0075) 2019; 7
Nayak (10.1016/j.mri.2023.01.019_bb0115) 2020
Souza (10.1016/j.mri.2023.01.019_bb0090) 2019
References_xml – volume: 12
  start-page: 232
  year: Apr. 1985
  end-page: 233
  ident: bb0080
  article-title: Measurement of signal intensities in the presence of noise in MR images
  publication-title: Med Phys
  contributor:
    fullname: Henkelman
– volume: 31
  start-page: 1116
  year: Jul. 2006
  end-page: 1128
  ident: bb0105
  article-title: User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability
  publication-title: NeuroImage
  contributor:
    fullname: Yushkevich
– year: 2020
  ident: bb0115
  article-title: Data leakage detection and prevention: review and research directions
  contributor:
    fullname: Ojha
– volume: 29
  start-page: 2253
  year: May 2019
  end-page: 2262
  ident: bb0040
  article-title: Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study
  publication-title: Eur Radiol
  contributor:
    fullname: Bae
– volume: 7
  start-page: 43369
  year: 2019
  end-page: 43382
  ident: bb0075
  article-title: Dense convolutional networks for semantic segmentation
  publication-title: IEEE Access
  contributor:
    fullname: Lu
– year: Apr. 10, 2015
  ident: bb0070
  article-title: Very deep convolutional networks for large-scale image recognition
  contributor:
    fullname: Zisserman
– volume: 180
  start-page: 845
  year: Sep. 1991
  end-page: 848
  ident: bb0020
  article-title: Lung parenchyma: magnetic susceptibility in MR imaging
  publication-title: Radiology
  contributor:
    fullname: Pauly
– start-page: 257
  year: Oct. 2019
  end-page: 264
  ident: bb0090
  article-title: A hybrid frequency-domain/image-domain deep network for magnetic resonance image reconstruction
  publication-title: 2019 32nd SIBGRAPI conference on graphics, patterns and images (SIBGRAPI), Rio de Janeiro, Brazil
  contributor:
    fullname: Frayne
– year: Sep. 14, 2022
  ident: bb0095
  article-title: Hybrid-CS-Model-MRI
  contributor:
    fullname: Souza
– volume: 45
  start-page: 1901
  year: 2015
  end-page: 1915
  ident: bb0035
  article-title: Magnetic resonance imaging in children: common problems and possible solutions for lung and airways imaging
  publication-title: Pediatr Radiol
  contributor:
    fullname: Ciet
– year: 2022
  ident: bb0100
  article-title: josemanuel097/FBL_4DZTE_improvement
– volume: 51
  start-page: 743
  year: Jul. 2013
  end-page: 760
  ident: bb0025
  article-title: Managing radiation dose from thoracic multidetector computed tomography in pediatric patients: background, current issues, and recommendations
  publication-title: Radiol Clin North Am
  contributor:
    fullname: Lee
– start-page: 3431
  year: Jun. 2015
  end-page: 3440
  ident: bb0065
  article-title: Fully convolutional networks for semantic segmentation
  publication-title: 2015 IEEE conference on computer vision and pattern recognition (CVPR)
  contributor:
    fullname: Darrell
– start-page: 19
  year: May 2013
  end-page: 26
  ident: bb0085
  article-title: A review of wavelet denoising in medical imaging
  publication-title: 2013 8th international workshop on systems, signal processing and their applications (WoSSPA)
  contributor:
    fullname: Ouahabi
– volume: 90
  year: Dec. 2017
  ident: bb0050
  article-title: Feasibility of free breathing lung MRI for radiotherapy using non-Cartesian k-space acquisition schemes
  publication-title: Br J Radiol
  contributor:
    fullname: Kumar
– volume: 30
  start-page: 5130
  year: Sep. 2020
  end-page: 5138
  ident: bb0055
  article-title: Respiratory motion–resolved four-dimensional zero echo time (4D ZTE) lung MRI using retrospective soft gating: feasibility and image quality compared with 3D ZTE
  publication-title: Eur Radiol
  contributor:
    fullname: Bae
– volume: 21
  start-page: 33
  year: Jan. 2020
  end-page: 41
  ident: bb0060
  article-title: Basics of deep learning: a Radiologist’s guide to understanding published radiology articles on deep learning
  publication-title: Korean J Radiol
  contributor:
    fullname: Chung
– volume: 380
  start-page: 499
  year: Aug. 2012
  end-page: 505
  ident: bb0030
  article-title: Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study
  publication-title: Lancet Lond Engl
  contributor:
    fullname: Pearce
– volume: 47
  start-page: 200
  year: Jan. 2018
  end-page: 209
  ident: bb0015
  article-title: Free-breathing pediatric chest MRI: performance of self-navigated golden-angle ordered conical ultrashort echo time acquisition
  publication-title: J Magn Reson Imaging JMRI
  contributor:
    fullname: Vasanawala
– volume: 50
  start-page: S57
  year: Oct. 2015
  end-page: S65
  ident: bb0010
  article-title: Respiratory tract exacerbations revisited: ventilation, inflammation, perfusion, and structure (VIPS) monitoring to redefine treatment
  publication-title: Pediatr Pulmonol
  contributor:
    fullname: Tiddens
– volume: 27
  start-page: 201
  year: May 2019
  end-page: 225
  ident: bb0005
  article-title: MR imaging of lungs and airways in children
  publication-title: Magn Reson Imaging Clin N Am
  contributor:
    fullname: Lee
– volume: 160
  start-page: 803
  year: Sep. 1986
  end-page: 810
  ident: bb0045
  article-title: Comparison of respiratory triggering and gating techniques for the removal of respiratory artifacts in MR imaging
  publication-title: Radiology
  contributor:
    fullname: Nicholson
– volume: 26
  start-page: 1530
  year: Dec. 2007
  end-page: 1536
  ident: bb0110
  article-title: Correlation of lung parenchymal MR signal intensity with pulmonary function tests and quantitative computed tomography (CT) evaluation: a pilot study
  publication-title: J Magn Reson Imaging JMRI
  contributor:
    fullname: Iwasawa
– start-page: 19
  year: 2013
  ident: 10.1016/j.mri.2023.01.019_bb0085
  article-title: A review of wavelet denoising in medical imaging
  contributor:
    fullname: Ouahabi
– volume: 47
  start-page: 200
  issue: 1
  year: 2018
  ident: 10.1016/j.mri.2023.01.019_bb0015
  article-title: Free-breathing pediatric chest MRI: performance of self-navigated golden-angle ordered conical ultrashort echo time acquisition
  publication-title: J Magn Reson Imaging JMRI
  doi: 10.1002/jmri.25776
  contributor:
    fullname: Zucker
– volume: 7
  start-page: 43369
  year: 2019
  ident: 10.1016/j.mri.2023.01.019_bb0075
  article-title: Dense convolutional networks for semantic segmentation
  publication-title: IEEE Access
  doi: 10.1109/ACCESS.2019.2908685
  contributor:
    fullname: Han
– volume: 51
  start-page: 743
  issue: 4
  year: 2013
  ident: 10.1016/j.mri.2023.01.019_bb0025
  article-title: Managing radiation dose from thoracic multidetector computed tomography in pediatric patients: background, current issues, and recommendations
  publication-title: Radiol Clin North Am
  doi: 10.1016/j.rcl.2013.04.007
  contributor:
    fullname: Macdougall
– volume: 26
  start-page: 1530
  issue: 6
  year: 2007
  ident: 10.1016/j.mri.2023.01.019_bb0110
  article-title: Correlation of lung parenchymal MR signal intensity with pulmonary function tests and quantitative computed tomography (CT) evaluation: a pilot study
  publication-title: J Magn Reson Imaging JMRI
  doi: 10.1002/jmri.21183
  contributor:
    fullname: Iwasawa
– volume: 180
  start-page: 845
  issue: 3
  year: 1991
  ident: 10.1016/j.mri.2023.01.019_bb0020
  article-title: Lung parenchyma: magnetic susceptibility in MR imaging
  publication-title: Radiology
  doi: 10.1148/radiology.180.3.1871305
  contributor:
    fullname: Bergin
– ident: 10.1016/j.mri.2023.01.019_bb0095
  contributor:
    fullname: Souza
– volume: 29
  start-page: 2253
  issue: 5
  year: 2019
  ident: 10.1016/j.mri.2023.01.019_bb0040
  article-title: Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study
  publication-title: Eur Radiol
  doi: 10.1007/s00330-018-5889-x
  contributor:
    fullname: Bae
– start-page: 257
  year: 2019
  ident: 10.1016/j.mri.2023.01.019_bb0090
  article-title: A hybrid frequency-domain/image-domain deep network for magnetic resonance image reconstruction
  contributor:
    fullname: Souza
– volume: 31
  start-page: 1116
  issue: 3
  year: 2006
  ident: 10.1016/j.mri.2023.01.019_bb0105
  article-title: User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability
  publication-title: NeuroImage
  doi: 10.1016/j.neuroimage.2006.01.015
  contributor:
    fullname: Yushkevich
– year: 2020
  ident: 10.1016/j.mri.2023.01.019_bb0115
  contributor:
    fullname: Nayak
– volume: 27
  start-page: 201
  issue: 2
  year: 2019
  ident: 10.1016/j.mri.2023.01.019_bb0005
  article-title: MR imaging of lungs and airways in children
  publication-title: Magn Reson Imaging Clin N Am
  doi: 10.1016/j.mric.2019.01.002
  contributor:
    fullname: Liszewski
– volume: 50
  start-page: S57
  issue: Suppl. 40
  year: 2015
  ident: 10.1016/j.mri.2023.01.019_bb0010
  article-title: Respiratory tract exacerbations revisited: ventilation, inflammation, perfusion, and structure (VIPS) monitoring to redefine treatment
  publication-title: Pediatr Pulmonol
  doi: 10.1002/ppul.23266
  contributor:
    fullname: Tiddens
– volume: 160
  start-page: 803
  issue: 3
  year: 1986
  ident: 10.1016/j.mri.2023.01.019_bb0045
  article-title: Comparison of respiratory triggering and gating techniques for the removal of respiratory artifacts in MR imaging
  publication-title: Radiology
  doi: 10.1148/radiology.160.3.3737921
  contributor:
    fullname: Lewis
– volume: 380
  start-page: 499
  issue: 9840
  year: 2012
  ident: 10.1016/j.mri.2023.01.019_bb0030
  article-title: Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study
  publication-title: Lancet Lond Engl
  doi: 10.1016/S0140-6736(12)60815-0
  contributor:
    fullname: Pearce
– volume: 30
  start-page: 5130
  issue: 9
  year: 2020
  ident: 10.1016/j.mri.2023.01.019_bb0055
  article-title: Respiratory motion–resolved four-dimensional zero echo time (4D ZTE) lung MRI using retrospective soft gating: feasibility and image quality compared with 3D ZTE
  publication-title: Eur Radiol
  doi: 10.1007/s00330-020-06890-x
  contributor:
    fullname: Bae
– volume: 45
  start-page: 1901
  issue: 13
  year: 2015
  ident: 10.1016/j.mri.2023.01.019_bb0035
  article-title: Magnetic resonance imaging in children: common problems and possible solutions for lung and airways imaging
  publication-title: Pediatr Radiol
  doi: 10.1007/s00247-015-3420-y
  contributor:
    fullname: Ciet
– volume: 90
  issue: 1080
  year: 2017
  ident: 10.1016/j.mri.2023.01.019_bb0050
  article-title: Feasibility of free breathing lung MRI for radiotherapy using non-Cartesian k-space acquisition schemes
  publication-title: Br J Radiol
  doi: 10.1259/bjr.20170037
  contributor:
    fullname: Kumar
– ident: 10.1016/j.mri.2023.01.019_bb0070
  contributor:
    fullname: Simonyan
– volume: 12
  start-page: 232
  issue: 2
  year: 1985
  ident: 10.1016/j.mri.2023.01.019_bb0080
  article-title: Measurement of signal intensities in the presence of noise in MR images
  publication-title: Med Phys
  doi: 10.1118/1.595711
  contributor:
    fullname: Henkelman
– start-page: 3431
  year: 2015
  ident: 10.1016/j.mri.2023.01.019_bb0065
  article-title: Fully convolutional networks for semantic segmentation
  contributor:
    fullname: Long
– volume: 21
  start-page: 33
  issue: 1
  year: 2020
  ident: 10.1016/j.mri.2023.01.019_bb0060
  article-title: Basics of deep learning: a Radiologist’s guide to understanding published radiology articles on deep learning
  publication-title: Korean J Radiol
  doi: 10.3348/kjr.2019.0312
  contributor:
    fullname: Do
SSID ssj0005235
Score 2.4344451
Snippet Despite a growing interest in lung MRI, its broader use in a clinical setting remains challenging. Several factors limit the image quality of lung MRI, such as...
INTRODUCTIONDespite a growing interest in lung MRI, its broader use in a clinical setting remains challenging. Several factors limit the image quality of lung...
SourceID proquest
crossref
pubmed
elsevier
SourceType Aggregation Database
Index Database
Publisher
StartPage 97
SubjectTerms Deep Learning
Fully convolutional neural networks
Humans
Image Interpretation, Computer-Assisted - methods
Lung
Magnetic resonance imaging
Magnetic Resonance Imaging - methods
Respiration
Retrospective Studies
Zero TE
Title Deep learning for improving ZTE MRI images in free breathing
URI https://dx.doi.org/10.1016/j.mri.2023.01.019
https://www.ncbi.nlm.nih.gov/pubmed/36681310
https://search.proquest.com/docview/2768239763
Volume 98
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LSwMxEA6lgngR39ZHieBJ2HazSdNd8FJqS6u0B22heAnZ3URWcFv6uPrbndmHKKgHYS8bZtnwZZh8k5nMEHINKuQboMYOiwPPEczEThBipNC4VocumOWsTsFoLAdTcT9rzSqkW96FwbTKwvbnNj2z1sVIs0CzuUiS5hMqZ9sDZ4tn8TQsuy1g-wOdbrx_TfPIm2yCsIPSZWQzy_F6WyYN7B-eVe7EYjs_702_cc9sD-rvkd2CPNJOPr99UjHpAdkeFeHxQ3J7Z8yCFo0gXijwUZqUhwb0edKjo8chjIAJWdEkpXZpDA2RNeIx1BGZ9nuT7sAp2iM4EQ_k2pEaXBdmMRDnaRGjIyJiYTlmWmK9WauZ9b1YR23TDowwcSytjayxQnPuRoIfk2o6T80poUy6IkTy5UsQbPl4t7zt6ygKtGFh6NbITQmMWuRVMFSZHvaqAEWFKCqXwRPUiCihU9-WUoGV_uuzqxJmBSqOcQudmvlmpTxwiTzkTbxGTnL8P2fBpfQZUNSz__30nOzgW57BeEGq6-XGXALLWIf1TI3qZKszfBiMPwBLRs4T
link.rule.ids 315,783,787,4509,24128,27936,27937,45597,45691
linkProvider Elsevier
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3dS8MwED-mgvoifjs_I_gk1PUjpi34MuZGp9sedIL4EtI2kQp2Y87_37t-iIL6IPQpTWj45Xr5Xe5yB3CGIhRopMaWk4auxR2dWmFMnkJtGxXbqJaLPAXDkYge-M3j5WMDOvVdGAqrrHR_qdMLbV21tCo0W9Msa92TcPouGlte4U8TC7CEbCDEv3Op3b-NRl8iPco6m9jfogG1c7MI83qdZRdUQrxI3kn5dn7enn6jn8U21FuHtYo_snY5xQ1o6HwTloeVh3wLrq61nrKqFsQzQ0rKsvrcgD2Nu2x418cW1CJvLMuZmWnNYiKOdBK1DQ-97rgTWVWFBCvxQjG3hELrxTHki3MVT8kW4Sk3HgVbUspZoxwTuKlKfO2Hmus0FcYkRhuuPM9OuLcDi_kk13vAHGHzmPhXILDjZUDXy_1AJUmotBPHdhPOa2DktEyEIesIsReJKEpCUdoOPmETeA2d_LaaEhX1X8NOa5glSjm5LlSuJ-9v0kWryCXq5DVht8T_cxaeEIGDLHX_fx89gZVoPBzIQX90ewCr9KYMaDyExfnsXR8h6ZjHx5VQfQB8btDH
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Deep+learning+for+improving+ZTE+MRI+images+in+free+breathing&rft.jtitle=Magnetic+resonance+imaging&rft.au=Papp%2C+D.&rft.au=Castillo+T%2C+Jose+M.&rft.au=Wielopolski%2C+P.A.&rft.au=Ciet%2C+P.&rft.date=2023-05-01&rft.pub=Elsevier+Inc&rft.issn=0730-725X&rft.eissn=1873-5894&rft.volume=98&rft.spage=97&rft.epage=104&rft_id=info:doi/10.1016%2Fj.mri.2023.01.019&rft.externalDocID=S0730725X23000206
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0730-725X&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0730-725X&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0730-725X&client=summon