Angular reconstruction of a lead scintillating-fiber sandwiched electromagnetic calorimeter

The Neighbor Cell Deposited Energy Ratio (NCDER) is a new method that is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL). This method was applied to reconstruct the ECAL test beam data for the Alpha Magnetic Spectrometer-02...

Full description

Saved in:
Bibliographic Details
Published inChinese physics C Vol. 38; no. 5; pp. 76 - 81
Main Author 李祖豪 许伟伟 王玲玉 张诚 唐志成 严琪 杨民 吕雨生 陈国明 陈和生
Format Journal Article
LanguageEnglish
Published 01.05.2014
Subjects
Online AccessGet full text
ISSN1674-1137
0254-3052
DOI10.1088/1674-1137/38/5/056203

Cover

Loading…
Abstract The Neighbor Cell Deposited Energy Ratio (NCDER) is a new method that is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL). This method was applied to reconstruct the ECAL test beam data for the Alpha Magnetic Spectrometer-02 (AMS-02). The results show that this method can achieve an angular resolution of 7.36±0.08°/√E+0.28±0.02° in the determination of the photon's direction, which is much more precise than that obtained with the commonly-adopted Center of Gravity (COG) method (8.4±0.1°/E+0.8±0.3°). Furthermore, since it uses only the properties of electromagnetic showers, this new method could also be used for other type of fine grain sampling calorimeters.
AbstractList The Neighbor Cell Deposited Energy Ratio (NCDER) is a new method that is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL). This method was applied to reconstruct the ECAL test beam data for the Alpha Magnetic Spectrometer-02 (AMS-02). The results show that this method can achieve an angular resolution of 7.36 0.08[degrees][radical]E[+ in circle]0.28 0.02[degrees] in the determination of the photon's direction, which is much more precise than that obtained with the commonly-adopted Center of Gravity (COG) method (8.4 0.1[degrees]/[radical]E[+ in circle]0.8 0.3[degrees]). Furthermore, since it uses only the properties of electromagnetic showers, this new method could also be used for other type of fine grain sampling calorimeters.
The Neighbor Cell Deposited Energy Ratio (NCDER) is a new method that is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL). This method was applied to reconstruct the ECAL test beam data for the Alpha Magnetic Spectrometer-02 (AMS-02). The results show that this method can achieve an angular resolution of 7.36±0.08°/√E+0.28±0.02° in the determination of the photon's direction, which is much more precise than that obtained with the commonly-adopted Center of Gravity (COG) method (8.4±0.1°/E+0.8±0.3°). Furthermore, since it uses only the properties of electromagnetic showers, this new method could also be used for other type of fine grain sampling calorimeters.
Author 李祖豪 许伟伟 王玲玉 张诚 唐志成 严琪 杨民 吕雨生 陈国明 陈和生
AuthorAffiliation Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
Author_xml – sequence: 1
  fullname: 李祖豪 许伟伟 王玲玉 张诚 唐志成 严琪 杨民 吕雨生 陈国明 陈和生
BookMark eNqFkD1PwzAURS1UJFrgJyCFjSXUju3EEVNV8SVVYoGJwXpxXlqj1G5tV4h_T6pWHViY3nLP1btnQkbOOyTkhtF7RpWasrISOWO8mnI1lVMqy4LyMzKmhRQ5p7IYkfEpc0EmMX5RWooBHZPPmVvueghZQONdTGFnkvUu810GWY_QZtFYl2zfQ7JumXe2wZBFcO23NStsM-zRpODXsHSYrMkM9D7YNSYMV-S8gz7i9fFeko-nx_f5S754e36dzxa54bVMuQJesAZK1aJpoeoMFIa3TSU6WXLGBEcFBSoJCBRqbHhXStHIhtdF3RhT8ktyd-jdBL_dYUx6baPB4WWHfhc1q2pelEoJNUQfDlETfIwBO21sgv3iFMD2mlG9V6r3uvRel-ZKS31QOtDyD70ZpkL4-Ze7PXIr75bbweMJFLVQjAvBfwFZQInR
CitedBy_id crossref_primary_10_1007_s41605_019_0113_3
crossref_primary_10_1007_s41605_024_00475_8
crossref_primary_10_1007_s41605_018_0041_7
Cites_doi 10.1016/j.asr.2009.08.005
10.1016/S0920-5632(97)00087-X
10.1016/S0920-5632(02)01836-4
10.1088/1674-1137/32/3/006
10.1016/S0927-6505(99)00115-2
ContentType Journal Article
DBID 2RA
92L
CQIGP
~WA
AAYXX
CITATION
7U5
8FD
H8D
L7M
DOI 10.1088/1674-1137/38/5/056203
DatabaseName 维普期刊资源整合服务平台
中文科技期刊数据库-CALIS站点
维普中文期刊数据库
中文科技期刊数据库- 镜像站点
CrossRef
Solid State and Superconductivity Abstracts
Technology Research Database
Aerospace Database
Advanced Technologies Database with Aerospace
DatabaseTitle CrossRef
Aerospace Database
Solid State and Superconductivity Abstracts
Technology Research Database
Advanced Technologies Database with Aerospace
DatabaseTitleList Aerospace Database

DeliveryMethod fulltext_linktorsrc
Discipline Physics
DocumentTitleAlternate Angular reconstruction of a lead scintillating-fiber sandwiched electromagnetic calorimeter
EISSN 0254-3052
EndPage 81
ExternalDocumentID 10_1088_1674_1137_38_5_056203
49481344
GroupedDBID 02O
1JI
1WK
29B
2B.
2C.
2RA
4.4
5B3
5GY
5VR
5VS
7.M
92E
92I
92L
92Q
93N
AAGCD
AAGID
AAJIO
AAJKP
AALHV
AATNI
ABCXL
ABHWH
ABJNI
ACAFW
ACGFS
ACHIP
AENEX
AFUIB
AFYNE
AIBLX
AKPSB
ALMA_UNASSIGNED_HOLDINGS
ATQHT
BBWZM
CCEZO
CCVFK
CEBXE
CHBEP
CJUJL
CQIGP
CRLBU
CW9
DU5
EBS
EDWGO
EJD
EPQRW
EQZZN
ER.
FA0
FEDTE
HVGLF
IJHAN
IOP
IZVLO
JCGBZ
KNG
KOT
M45
N5L
NT-
NT.
OK1
PJBAE
Q02
RIN
RNS
ROL
RPA
RW3
SY9
TCJ
TGP
W28
~WA
-SA
-SC
-S~
AAYXX
ADEQX
AERVB
AOAED
CAJEA
CAJEC
CITATION
Q--
U1G
U5K
U5M
7U5
8FD
AEINN
H8D
L7M
ID FETCH-LOGICAL-c395t-8a321ba68decda7fca2c3db74f5631143e8a2e85aea0a9eb3f654b5b3929bcc63
ISSN 1674-1137
IngestDate Tue Aug 05 10:30:46 EDT 2025
Tue Jul 01 03:03:10 EDT 2025
Thu Apr 24 23:06:02 EDT 2025
Wed Feb 14 10:37:13 EST 2024
IsDoiOpenAccess false
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 5
Language English
License http://iopscience.iop.org/info/page/text-and-data-mining
http://iopscience.iop.org/page/copyright
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c395t-8a321ba68decda7fca2c3db74f5631143e8a2e85aea0a9eb3f654b5b3929bcc63
Notes The Neighbor Cell Deposited Energy Ratio (NCDER) is a new method that is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL). This method was applied to reconstruct the ECAL test beam data for the Alpha Magnetic Spectrometer-02 (AMS-02). The results show that this method can achieve an angular resolution of 7.36±0.08°/√E+0.28±0.02° in the determination of the photon's direction, which is much more precise than that obtained with the commonly-adopted Center of Gravity (COG) method (8.4±0.1°/E+0.8±0.3°). Furthermore, since it uses only the properties of electromagnetic showers, this new method could also be used for other type of fine grain sampling calorimeters.
11-5641/O4
electromagnetic calorimeter, angular resolution, lateral fit, Neighbor Cell Deposited Energy Ratio
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
OpenAccessLink http://cds.cern.ch/record/1595388
PQID 1793268848
PQPubID 23500
PageCount 6
ParticipantIDs proquest_miscellaneous_1793268848
crossref_citationtrail_10_1088_1674_1137_38_5_056203
crossref_primary_10_1088_1674_1137_38_5_056203
chongqing_primary_49481344
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2014-05-01
PublicationDateYYYYMMDD 2014-05-01
PublicationDate_xml – month: 05
  year: 2014
  text: 2014-05-01
  day: 01
PublicationDecade 2010
PublicationTitle Chinese physics C
PublicationTitleAlternate Chinese Physica C
PublicationYear 2014
References 1
2
Tao Jun-Quan (5) 2008; 32
3
6
Li Zu-Hao (7) 2004; 28
Wang Xiao-Bin (8) 2005; 29
Di Falco Stefano (4) 2010; 45
References_xml – volume: 45
  start-page: 112
  issn: 0273-1177
  year: 2010
  ident: 4
  publication-title: Advances in Space Research
  doi: 10.1016/j.asr.2009.08.005
– ident: 2
  doi: 10.1016/S0920-5632(97)00087-X
– ident: 3
  doi: 10.1016/S0920-5632(02)01836-4
– volume: 29
  start-page: 1071
  issn: 0899-9996
  year: 2005
  ident: 8
  publication-title: HEP & NP
– ident: 6
– volume: 32
  start-page: 191
  year: 2008
  ident: 5
  publication-title: Chinese Physics C (HEP & NP)
  doi: 10.1088/1674-1137/32/3/006
– ident: 1
  doi: 10.1016/S0927-6505(99)00115-2
– volume: 28
  start-page: 1182
  issn: 0899-9996
  year: 2004
  ident: 7
  publication-title: HEP & NP
SSID ssj0064088
Score 1.9692955
Snippet The Neighbor Cell Deposited Energy Ratio (NCDER) is a new method that is proposed to reconstruct incidence position in a single layer for a 3-dimensional...
The Neighbor Cell Deposited Energy Ratio (NCDER) is a new method that is proposed to reconstruct incidence position in a single layer for a 3-dimensional...
SourceID proquest
crossref
chongqing
SourceType Aggregation Database
Enrichment Source
Index Database
Publisher
StartPage 76
SubjectTerms Alpha Magnetic Spectrometer
Angular resolution
Center of gravity
Cog
Deposition
Reconstruction
Sampling
Showers
夹层
测定方法
电磁量能器
能量比率
角分辨率

闪烁光纤
阿尔法磁谱仪
Title Angular reconstruction of a lead scintillating-fiber sandwiched electromagnetic calorimeter
URI http://lib.cqvip.com/qk/92043A/201405/49481344.html
https://www.proquest.com/docview/1793268848
Volume 38
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3db9MwELdgCIkXxKfo-FCQeKu8JvFHncdpAhU0YA-bVODBsh2nRRoJqK2Q-Ou5c-Kk3SZgPDSKLOUa-Xc5n893vyPklWOFkoXjlJVCUi6loZbZkgpplaqUNNNAmf_-g5yd8XdzMR9O8EN1ydoeuF9X1pX8D6owBrhilew1kO2FwgDcA75wBYTh-k8YH9aLkEUadrU9E2xb8ngO4GG5Y73GvkKY3EwrzA4Zr0xd_sQE0HLc9cD5ZhY11jKOAa8G6f5jym5kMFiGPpVdFGQ1BFaPQyrA5w2dmSaOzTchbc9_pfAbwvWtSTnG1_i0uRStPlr6bgXtAhAZH9L9Opspp5xmWcvdEo0qU1vKI7YsJPhbgdTgsu0Ge4dhhCgN7gN1e-C-6J_aZcy-sJL1-YXhZF0pjcI0CtNMaaFbMTfJrRz2FNjn4-3Hk7hsS56GJqX9_8dyL6Um_diEqYmYtGKQjGPZ1IsfMHO7Ts3umh4cldN75G63w0gOW3W5T274-gG5fdJi95B86ZQm2VWapKkSk6DSJFcoTTIoTXJBaZItpXlEzt68Pj2a0a7DBoVvVKypMizPrJGq9K4008qZ3CHhNq-EZLBTZl6Z3CthvElN4S2rpOBWWHSqrXOSPSZ7dVP7JySpUlGq1MH-Myu4rWzhU--kceCAljC1ckT2--nS31smFY3cRBnjfER4nD_tOm56bJFyrv-I5Igc9I9FkX954GUER4MZxbMxU_tms9K4TuVSKa72ryv0KbkzfBbPyB4A55-Dp7q2L4KG_QYjoI1H
linkProvider IOP Publishing
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Angular+reconstruction+of+a+lead+scintillating-fiber+sandwiched+electromagnetic+calorimeter&rft.jtitle=Chinese+physics+C&rft.au=Li%2C+Zu-Hao&rft.au=Xu%2C+Wei-Wei&rft.au=Wang%2C+Ling-Yu&rft.au=Zhang%2C+Cheng&rft.date=2014-05-01&rft.issn=1674-1137&rft.volume=38&rft.issue=5&rft.spage=56203&rft_id=info:doi/10.1088%2F1674-1137%2F38%2F5%2F056203&rft.externalDBID=n%2Fa&rft.externalDocID=10_1088_1674_1137_38_5_056203
thumbnail_s http://utb.summon.serialssolutions.com/2.0.0/image/custom?url=http%3A%2F%2Fimage.cqvip.com%2Fvip1000%2Fqk%2F92043A%2F92043A.jpg