Evaluation of pulling rope wear and coefficient of friction for pipe-type cables

The coefficient of friction between the pulling rope and cable pipe for a high-pressure fluid-filled cable was determined in order to characterize the effects of pulling tension and sidewall pressure on this parameter. Pipe wear was also measured. The study found that variations in pulling tension w...

Full description

Saved in:
Bibliographic Details
Published inIEEE transactions on power delivery Vol. 12; no. 2; pp. 542 - 546
Main Authors Bascom, E.C., Stewart, J.R., Tang, L.Y.
Format Journal Article Conference Proceeding
LanguageEnglish
Published New York, NY IEEE 01.04.1997
Institute of Electrical and Electronics Engineers
Subjects
Online AccessGet full text
ISSN0885-8977
DOI10.1109/61.584318

Cover

Loading…
Abstract The coefficient of friction between the pulling rope and cable pipe for a high-pressure fluid-filled cable was determined in order to characterize the effects of pulling tension and sidewall pressure on this parameter. Pipe wear was also measured. The study found that variations in pulling tension were more strongly affected by pulling rope wear than pipe wear. The coefficient of friction of the pulling rope varied from 0.27 to 0.75. Pipe wear of 1.52 mm (60 mils) was measured during 430 m (1425 ft.) of pulls at 1414 kgf/m (950 lbs./ft.) sidewall pressure and 1.02 mm (40 mils) of wear was measured during 290 m (950 ft.) of pulls at 610 kgf/m (410 lbs./ft.) sidewall pressure.
AbstractList The coefficient of friction between the pulling rope and cable pipe for a high-pressure fluid-filled cable was determined in order to characterize the effects of pulling tension and sidewall pressure on this parameter. Pipe wear was also measured. The study found that variations in pulling tension were more strongly affected by pulling rope wear than pipe wear. The coefficient of friction of the pulling rope varied from 0.27 to 0.75. Pipe wear of 1.52 mm (60 mils) was measured during 430 m (1425 ft.) of pulls at 1414 kgf/m (950 lbs./ft.) sidewall pressure and 1.02 mm (40 mils) of wear was measured during 290 m (950 ft.) of pulls at 610 kgf/m (410 lbs./ft.) sidewall pressure.
The coefficient of friction between the pulling rope and cable pipe for a high-pressure fluid-filled cable was determined in order to characterize the effects of pulling tension and sidewall pressure on this parameter. Pipe wear was also measured. The study found that variations in pulling tension were more strongly affected by pulling rope wear than pipe wear. The coefficient of friction of the pulling rope varied from 0.27 to 0.75. Pipe wear of 1.52 mm (60 mils) was measured during 430 m (1425 ft.) of pulls at 1414 kgf/m (950 lbs./ft.) sidewall pressure and 1.02 mm (40 mils) of wear was measured during 290 m (950 ft.) of pulls at 610 kgf/m (410 lbs./ft.) sidewall pressure
Author Tang, L.Y.
Stewart, J.R.
Bascom, E.C.
Author_xml – sequence: 1
  givenname: E.C.
  surname: Bascom
  fullname: Bascom, E.C.
  organization: Power Technol. Inc., Schenectady, NY, USA
– sequence: 2
  givenname: J.R.
  surname: Stewart
  fullname: Stewart, J.R.
– sequence: 3
  givenname: L.Y.
  surname: Tang
  fullname: Tang, L.Y.
BackLink http://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=2640343$$DView record in Pascal Francis
BookMark eNqF0T1LxjAQB_AMCr4Ork4dRHCo5pq0TUYR30DQQedwTS8SiU1N-ih-e6vPo4MITjfc738cd1tsbYgDMbYH_BiA65MGjmslBag1tsmVqkul23aDbeX8xDmXXPNNdnf-imGBk49DEV0xLkLww2OR4kjFG2EqcOgLG8k5bz0N0ydyyduvgIupGP1I5fQ-c4tdoLzD1h2GTLurus0eLs7vz67Km9vL67PTm9IKLadS9KBa0WkldWUlNHUnO1KCV11jux61bnpEdD1vZN23yvIOegLSEnndgtJimx0u544pviwoT-bZZ0sh4EBxkU2lWhBVDf_DVs6rQP0vhIZDxat2hgcriNlicAkH67MZk3_G9G6qRnIhxcxOlsymmHMiZ6yfvi49JfTBADefbzINmOWb5sTRr8T3zL_s_tJ6Ivpxq-YHYhydTA
CODEN ITPDE5
CitedBy_id crossref_primary_10_1177_0954406212473887
crossref_primary_10_1016_j_mechmachtheory_2015_07_004
Cites_doi 10.1109/AIEEPAS.1953.4498766
10.1109/TDC.1979.712647
ContentType Journal Article
Conference Proceeding
Copyright 1997 INIST-CNRS
Copyright_xml – notice: 1997 INIST-CNRS
DBID AAYXX
CITATION
IQODW
7SP
8FD
L7M
DOI 10.1109/61.584318
DatabaseName CrossRef
Pascal-Francis
Electronics & Communications Abstracts
Technology Research Database
Advanced Technologies Database with Aerospace
DatabaseTitle CrossRef
Technology Research Database
Advanced Technologies Database with Aerospace
Electronics & Communications Abstracts
DatabaseTitleList Technology Research Database


Technology Research Database
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
Applied Sciences
EndPage 546
ExternalDocumentID 280150
2640343
10_1109_61_584318
584318
GroupedDBID -~X
.DC
0R~
29I
3EH
4.4
5GY
5VS
6IK
97E
AAJGR
AARMG
AASAJ
AAWTH
ABAZT
ABQJQ
ABVLG
ACGFO
ACGFS
ACIWK
ACKIV
AENEX
AETIX
AGQYO
AGSQL
AHBIQ
AI.
AIBXA
AKJIK
AKQYR
ALLEH
ALMA_UNASSIGNED_HOLDINGS
ASUFR
ATWAV
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CS3
DU5
EBS
EJD
HZ~
H~9
ICLAB
IFIPE
IFJZH
IPLJI
JAVBF
LAI
M43
MS~
O9-
OCL
P2P
RIA
RIE
RNS
TAE
TN5
TWZ
VH1
VJK
AAYOK
AAYXX
CITATION
RIG
IQODW
7SP
8FD
L7M
ID FETCH-LOGICAL-c394t-3d1873b98492c4165b4be8302b6cbda996daaafd0645d78c0b1de1e94a0571893
IEDL.DBID RIE
ISSN 0885-8977
IngestDate Fri Sep 05 04:23:51 EDT 2025
Fri Sep 05 11:57:09 EDT 2025
Thu Sep 04 17:13:19 EDT 2025
Mon Jul 21 09:14:33 EDT 2025
Thu Apr 24 23:01:43 EDT 2025
Tue Jul 01 02:11:03 EDT 2025
Tue Aug 26 20:56:52 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 2
Keywords Cable
Tensile stress
Pipe cable
Mechanical measurement
Tube wall
Wear
Friction coefficient
Oil filled cable
Electrical cable
Experimental study
Pressure
Language English
License https://ieeexplore.ieee.org/Xplorehelp/downloads/license-information/IEEE.html
CC BY 4.0
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c394t-3d1873b98492c4165b4be8302b6cbda996daaafd0645d78c0b1de1e94a0571893
Notes ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
PQID 16012027
PQPubID 23500
PageCount 5
ParticipantIDs crossref_citationtrail_10_1109_61_584318
proquest_miscellaneous_16012027
proquest_miscellaneous_28713251
crossref_primary_10_1109_61_584318
pascalfrancis_primary_2640343
ieee_primary_584318
proquest_miscellaneous_27418715
ProviderPackageCode CITATION
AAYXX
PublicationCentury 1900
PublicationDate 1997-04-01
PublicationDateYYYYMMDD 1997-04-01
PublicationDate_xml – month: 04
  year: 1997
  text: 1997-04-01
  day: 01
PublicationDecade 1990
PublicationPlace New York, NY
PublicationPlace_xml – name: New York, NY
PublicationTitle IEEE transactions on power delivery
PublicationTitleAbbrev TPWRD
PublicationYear 1997
Publisher IEEE
Institute of Electrical and Electronics Engineers
Publisher_xml – name: IEEE
– name: Institute of Electrical and Electronics Engineers
References ref3
ref2
(ref1) 1983
References_xml – ident: ref3
  doi: 10.1109/AIEEPAS.1953.4498766
– ident: ref2
  doi: 10.1109/TDC.1979.712647
– year: 1983
  ident: ref1
  publication-title: Increasing Pipe Cable Section Lengths
SSID ssj0004090
Score 1.5316327
SecondaryResourceType review_article
Snippet The coefficient of friction between the pulling rope and cable pipe for a high-pressure fluid-filled cable was determined in order to characterize the effects...
SourceID proquest
pascalfrancis
crossref
ieee
SourceType Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage 542
SubjectTerms Aluminum
Applied sciences
Cables
Conducting materials
Electric connection. Cables. Wiring
Electrical engineering. Electrical power engineering
Exact sciences and technology
Force measurement
Friction
Materials testing
Pressure measurement
Pulleys
Q1
Steel
Testing
Various equipment and components
Winches
Title Evaluation of pulling rope wear and coefficient of friction for pipe-type cables
URI https://ieeexplore.ieee.org/document/584318
https://www.proquest.com/docview/16012027
https://www.proquest.com/docview/27418715
https://www.proquest.com/docview/28713251
Volume 12
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LS8QwEA6uJz34WBVXXQ3iwUt3mzbbTY4iigiKBwVvJa-CKO1itwj-emeS7voWL6U0kz5mks6Xx3xDyJFKC-WcLCLAFiLiKRy0VjrSVgGeAw8uDa7oXl1nF3f88n503_Js-1gY55zffOYGeOrX8m1lGpwqG4KzhCbYIR1oZSFU6z0EMg7TKUKMIgHPbUmEWCyHGRuEip9cj8-lgjshVQ3KKEIWi28_ZO9lzldD-HbtyQlxc8njoJnqgXn9Qt34zw9YIyst2qQnoXmskwVXdsnyBw7CDXJzNuf7plVBJ40n6aY4R09foBtQVVpqKuepJuDuKIS5hXwFQLx08jBxEc7kUoNhWPUmuTs_uz29iNo0C5FJJZ9GqWVinGopuEwM4LOR5tohLZjODJgMBkRWKVVYZLazY2FizaxjTnIFWI8B3tkii2VVum0MAJc8KUD_idNc4HCOZ0j_A0NwIworeuR4ZoHctBzkmArjKfdjkVjmGcuDknrkcC46CcQbPwl1UclzgdnV_ierzosB_MUpT3vkYGblHDoTrpCo0lVNnbMMY4mT8e8Snu1nzEZ_SEBxCqhx58d32yVLgQAX9_7skcXpc-P6AGumet836Dck7_Yy
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1JS8QwFA4uB_XgLo5rEA9eOjbTtJMcRZRxxYOCt5KtIEo7OFMEf73vJZ1xFy-lNC9d3kv6vizve4Tsq6RQzskiAmwhIp7AQWulI20V4Dnw4NLgiu7Vdda74-f36X3Ds-1jYZxzfvOZa-OpX8u3lalxquwQnCU0wUkyDW6fpyFY6z0IMg4TKkKkkYAnNzRCLJaHGWuHqp-cj8-mgnsh1QDUUYQ8Ft9-yd7PnC6EAO6BpyfE7SWP7Xqo2-b1C3njPz9hkcw3eJMehQayRCZcuUzmPrAQrpCbkzHjN60K2q89TTfFWXr6Ah2BqtJSUzlPNgF3RyHMLuQrAOal_Ye-i3AulxoMxBqskrvTk9vjXtQkWohMIvkwSiwT3URLwWXHAEJLNdcOicF0ZsBoMCSySqnCIred7QoTa2Ydc5IrQHsMEM8amSqr0q1jCLjknQL033GaCxzQ8QwJgGAQbkRhRYscjCyQm4aFHJNhPOV-NBLLPGN5UFKL7I1F-4F64yehZVTyWGB0dfuTVcfFAP_ihCctsjuycg7dCddIVOmqepCzDKOJO93fJTzfT5elf0hAcQK4cePHd9slM73bq8v88uz6YpPMBjpc3Am0RaaGz7XbBpAz1Du-cb8BKDj5fw
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=proceeding&rft.title=IEEE+transactions+on+power+delivery&rft.atitle=Evaluation+of+pulling+rope+wear+and+coefficient+of+friction+for+pipe-type+cables&rft.au=BASCOM%2C+E.+C&rft.au=STEWART%2C+J.+R&rft.au=TANG%2C+L.+Y&rft.date=1997-04-01&rft.pub=Institute+of+Electrical+and+Electronics+Engineers&rft.issn=0885-8977&rft.volume=12&rft.issue=2&rft.spage=542&rft.epage=546&rft_id=info:doi/10.1109%2F61.584318&rft.externalDBID=n%2Fa&rft.externalDocID=2640343
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0885-8977&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0885-8977&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0885-8977&client=summon