Comparison of Sampling Positions when Measuring Personal Exposure to Solder Fume
A sampling device based on a telephone headset was developed and used to support a sampler close to the mouth during personal exposure monitoring of solder fume. In a field trial, it was compared with the established method of mounting the sampler on the arm of a pair of spectacles, and a linear cor...
Saved in:
Published in | The Annals of occupational hygiene Vol. 49; no. 5; pp. 439 - 442 |
---|---|
Main Author | |
Format | Journal Article |
Language | English |
Published |
Oxford
Oxford University Press
01.07.2005
|
Subjects | |
Online Access | Get full text |
ISSN | 0003-4878 1475-3162 1475-3162 |
DOI | 10.1093/annhyg/meh107 |
Cover
Loading…
Abstract | A sampling device based on a telephone headset was developed and used to support a sampler close to the mouth during personal exposure monitoring of solder fume. In a field trial, it was compared with the established method of mounting the sampler on the arm of a pair of spectacles, and a linear correlation was evident between the two positions (slope 1.56 ± 0.05, r2 = 0.98). Although the headset sampler held the sampler closer to the breathing zone, experience showed that the spectacles position was less intrusive on the subject and allowed a more consistent and stable sampling position. On balance, the spectacles position was the preferred sampling location. |
---|---|
AbstractList | A sampling device based on a telephone headset was developed and used to support a sampler close to the mouth during personal exposure monitoring of solder fume. In a field trial, it was compared with the established method of mounting the sampler on the arm of a pair of spectacles, and a linear correlation was evident between the two positions (slope 1.56 ± 0.05, r2 = 0.98). Although the headset sampler held the sampler closer to the breathing zone, experience showed that the spectacles position was less intrusive on the subject and allowed a more consistent and stable sampling position. On balance, the spectacles position was the preferred sampling location. A sampling device based on a telephone headset was developed and used to support a sampler close to the mouth during personal exposure monitoring of solder fume. In a field trial, it was compared with the established method of mounting the sampler on the arm of a pair of spectacles, and a linear correlation was evident between the two positions (slope 1.56 +/- 0.05, r(2) = 0.98). Although the headset sampler held the sampler closer to the breathing zone, experience showed that the spectacles position was less intrusive on the subject and allowed a more consistent and stable sampling position. On balance, the spectacles position was the preferred sampling location.A sampling device based on a telephone headset was developed and used to support a sampler close to the mouth during personal exposure monitoring of solder fume. In a field trial, it was compared with the established method of mounting the sampler on the arm of a pair of spectacles, and a linear correlation was evident between the two positions (slope 1.56 +/- 0.05, r(2) = 0.98). Although the headset sampler held the sampler closer to the breathing zone, experience showed that the spectacles position was less intrusive on the subject and allowed a more consistent and stable sampling position. On balance, the spectacles position was the preferred sampling location. A sampling device based on a telephone headset was developed and used to support a sampler close to the mouth during personal exposure monitoring of solder fume. In a field trial, it was compared with the established method of mounting the sampler on the arm of a pair of spectacles, and a linear correlation was evident between the two positions (slope 1.56 +/- 0.05, r(2) = 0.98). Although the headset sampler held the sampler closer to the breathing zone, experience showed that the spectacles position was less intrusive on the subject and allowed a more consistent and stable sampling position. On balance, the spectacles position was the preferred sampling location. A sampling device based on a telephone headset was developed and used to support a sampler close to the mouth during personal exposure monitoring of solder fume. In a field trial, it was compared with the established method of mounting the sampler on the arm of a pair of spectacles, and a linear correlation was evident between the two positions (slope 1.56 plus or minus 0.05, r super(2) = 0.98). Although the headset sampler held the sampler closer to the breathing zone, experience showed that the spectacles position was less intrusive on the subject and allowed a more consistent and stable sampling position. On balance, the spectacles position was the preferred sampling location. |
Author | SIMPSON, A. T |
Author_xml | – sequence: 1 givenname: A. T surname: SIMPSON fullname: SIMPSON, A. T organization: Health and Safety Laboratory, Harpur Hill, Buxton, SK17 9JN, United Kingdom |
BackLink | http://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=16980346$$DView record in Pascal Francis https://www.ncbi.nlm.nih.gov/pubmed/15689396$$D View this record in MEDLINE/PubMed |
BookMark | eNqF0cFu1DAQBmALFdFt4cgV5QK3UE_txPYRhS5FKmJFQUJcLMcZdw2JHexEtG9Pll2KxAFOlu1vRqP5T8hRiAEJeQr0JVDFzkwI27ubswG3QMUDsgIuqpJBfX5EVpRSVnIp5DE5yfnrcuVMwSNyDFUtFVP1imyaOIwm-RxDEV1xbYax9-Gm2MTsJx9DLn5sMRTv0OQ5_frAtFjTFxe3Y1zesJhicR37DlOxngd8TB4602d8cjhPyaf1xcfmsrx6_-Zt8-qqtEzRqXTIWmUVdsxxZquKdwBKUUZBcGespEx21EHb2hYkgGS8E_y8pU51gBIFOyUv9n3HFL_PmCc9-Gyx703AOGddy10rXv0Xgqg5W-gCnx3g3A7Y6TH5waQ7_XtZC3h-ACZb07tkgvX5j6vVMjbfObZ3NsWcEzpt_WR225yS8b0GqnfR6X10eh_dUlX-VXXf-N_e5wlv77FJ33QtmKj05ecvGprmw_r1ZqM5-wkuoKyL |
CODEN | AOHYA3 |
CitedBy_id | crossref_primary_10_1093_annhyg_mep075 crossref_primary_10_1093_occmed_kqm034 crossref_primary_10_1093_annhyg_mep001 |
ContentType | Journal Article |
Copyright | 2005 INIST-CNRS |
Copyright_xml | – notice: 2005 INIST-CNRS |
DBID | BSCLL AAYXX CITATION IQODW CGR CUY CVF ECM EIF NPM 7T2 7TV C1K 7X8 |
DOI | 10.1093/annhyg/meh107 |
DatabaseName | Istex CrossRef Pascal-Francis Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed Health and Safety Science Abstracts (Full archive) Pollution Abstracts Environmental Sciences and Pollution Management MEDLINE - Academic |
DatabaseTitle | CrossRef MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) Pollution Abstracts Health & Safety Science Abstracts Environmental Sciences and Pollution Management MEDLINE - Academic |
DatabaseTitleList | MEDLINE - Academic MEDLINE Pollution Abstracts |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine Occupational Therapy & Rehabilitation |
EISSN | 1475-3162 |
EndPage | 442 |
ExternalDocumentID | 15689396 16980346 10_1093_annhyg_meh107 ark_67375_HXZ_1CCRFDPP_4 |
Genre | Research Support, Non-U.S. Gov't Journal Article Comparative Study |
GroupedDBID | --- --K -E4 .2P .55 .GJ .HR .I3 .XZ .ZR 04C 1B1 23M 2WC 3O- 4.4 482 48X 53G 5GY 5RE 5VS 5WA 5WD 6J9 70D A8Z AABZA AACZT AAEDT AAFWJ AAIMJ AAJKP AALRI AAMDB AAMVS AAOGV AAPGJ AAPNW AAPQZ AAPXW AAQFI AAQXK AARHZ AAUAY AAUQX AAVAP AAVLN AAWDT AAWTL AAXUO ABDFA ABEJV ABEUO ABGNP ABIME ABIXL ABJNI ABKDP ABMAC ABMNT ABNGD ABNHQ ABNKS ABPIB ABPQP ABPTD ABQLI ABSMQ ABVGC ABWST ABWVN ABXVV ABXZS ABZBJ ABZEO ACFRR ACGFO ACGFS ACPQN ACRPL ACUFI ACUKT ACUTJ ACUTO ACVCV ACVFH ACZBC ADBBV ADCNI ADEYI ADEZT ADFTL ADGKP ADGZP ADHKW ADHZD ADIPN ADMTO ADMUD ADNMO ADOCK ADQBN ADRTK ADVEK ADYVW ADZTZ ADZXQ AEGPL AEGXH AEHUL AEJOX AEKPW AEKSI AELWJ AEMDU AENEX AENZO AEPUE AETBJ AEUPX AFFQV AFFZL AFGWE AFIYH AFOFC AFPUW AFSHK AFYAG AGINJ AGKEF AGKRT AGMDO AGQPQ AGQXC AGSYK AHMMS AHXPO AI. AIAGR AIJHB AJDVS AJEEA AKHUL AKWXX ALMA_UNASSIGNED_HOLDINGS ALUQC ALXQX ANFBD APIBT APJGH APWMN AQDSO AQKUS ARIXL ASAOO ASPBG ATDFG ATGXG AVNTJ AVWKF AXUDD AYOIW AZFZN BAWUL BAYMD BCRHZ BHONS BMSDO BQDIO BSCLL BSWAC BTRTY BVRKM BZKNY CAG CDBKE COF CS3 CZ4 DIK DILTD D~K E3Z EBD EBS EE~ EIHBH EIHJH EJD ELUNK F5P F9B FDB FEDTE FGOYB FHSFR FLUFQ FOEOM FOTVD FQBLK GAUVT H13 H5~ HAR HVGLF HW0 HZ~ I-F IHE IOX J21 KOP KQ8 KSI KSN L7B M-Z M41 MBLQV MBTAY N9A NGC NLBLG NOMLY NOYVH NQ- NTWIH NU- NVLIB O0~ O9- OAWHX OBFPC OBOKY OCZFY ODMLO OJQWA OJZSN OPAEJ OVD O~Y P2P PB- PEELM Q1. Q5Y QBD R2- R44 RD5 RIG RNI ROL ROX ROZ RPZ RW1 RXO RZF RZO SEW TCN TEORI TJX TLC TMA TR2 UHS VH1 W8F WOQ WOW X7H X7M YKOAZ YXANX ZKX ZXP ~91 ~KM AAYXX CITATION M49 IQODW 1TH 6.Y ABQTQ ABSAR ADJQC ADRIX AFXEN CGR CUY CVF ECM EIF NPM OK1 UCJ 7T2 7TV C1K 7X8 |
ID | FETCH-LOGICAL-c390t-fe3b9c9ed3f43c554d1199030174fac8038d0f1bbcb1811834d742b0f9d1e8e73 |
ISSN | 0003-4878 1475-3162 |
IngestDate | Fri Jul 11 16:00:41 EDT 2025 Fri Jul 11 12:22:48 EDT 2025 Wed Feb 19 01:43:33 EST 2025 Mon Jul 21 09:14:47 EDT 2025 Tue Jul 01 03:15:05 EDT 2025 Thu Apr 24 22:58:36 EDT 2025 Tue Aug 05 16:48:38 EDT 2025 |
IsPeerReviewed | false |
IsScholarly | false |
Issue | 5 |
Keywords | resin acids Welding Samplings Occupational exposure Concentration measurement breathing zone Ambient air concentration Sampling equipment Ergonomics Portable equipment Sampling Face Fumes Occupational medicine Comparative study solder fume |
Language | English |
License | CC BY 4.0 |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c390t-fe3b9c9ed3f43c554d1199030174fac8038d0f1bbcb1811834d742b0f9d1e8e73 |
Notes | local:meh107 Tel: +44 1298 218518; fax: +44 1298 218570; e-mail: andrew.simpson@hsl.gov.uk ark:/67375/HXZ-1CCRFDPP-4 istex:F1A0305BDA619CC0161EC37F8D6FD6D1F3A89888 ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 |
PMID | 15689396 |
PQID | 17643174 |
PQPubID | 23462 |
PageCount | 4 |
ParticipantIDs | proquest_miscellaneous_68017445 proquest_miscellaneous_17643174 pubmed_primary_15689396 pascalfrancis_primary_16980346 crossref_citationtrail_10_1093_annhyg_meh107 crossref_primary_10_1093_annhyg_meh107 istex_primary_ark_67375_HXZ_1CCRFDPP_4 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2005-07-01 |
PublicationDateYYYYMMDD | 2005-07-01 |
PublicationDate_xml | – month: 07 year: 2005 text: 2005-07-01 day: 01 |
PublicationDecade | 2000 |
PublicationPlace | Oxford |
PublicationPlace_xml | – name: Oxford – name: England |
PublicationTitle | The Annals of occupational hygiene |
PublicationTitleAlternate | Ann Occup Hyg |
PublicationYear | 2005 |
Publisher | Oxford University Press |
Publisher_xml | – name: Oxford University Press |
SSID | ssj0004391 |
Score | 1.4300421 |
Snippet | A sampling device based on a telephone headset was developed and used to support a sampler close to the mouth during personal exposure monitoring of solder... |
SourceID | proquest pubmed pascalfrancis crossref istex |
SourceType | Aggregation Database Index Database Enrichment Source Publisher |
StartPage | 439 |
SubjectTerms | Adult Air Pollutants, Occupational - analysis Biological and medical sciences breathing zone Environmental Monitoring - instrumentation Environmental Monitoring - methods Equipment Design Ergonomics. Workplace layout Ergonomics. Workplace layout. Occupational psychology Female Gases Humans Male Medical sciences Occupational Exposure - analysis Occupational medicine Public health. Hygiene-occupational medicine resin acids sampling solder fume Welding |
Title | Comparison of Sampling Positions when Measuring Personal Exposure to Solder Fume |
URI | https://api.istex.fr/ark:/67375/HXZ-1CCRFDPP-4/fulltext.pdf https://www.ncbi.nlm.nih.gov/pubmed/15689396 https://www.proquest.com/docview/17643174 https://www.proquest.com/docview/68017445 |
Volume | 49 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1bb9MwFLZgkxAvE4xbBww_wF5Ktqa2c3lEHVMHKlRbJ1W8RIljU2lbgtZUbPx6zomdG1BuL1GUWrbr8_nks3P8HUJecpGGIhimTphwDQsUTPPiJb4zVEHKXC6FV0psTD544zP-bi7mVa52e7qkSPblt1-eK_kfq8IzsCuekv0Hy9aVwgO4B_vCFSwM17-y8aidRLC_jDE6HA-XV4FY_a8LlfUvy23A8gfLvFHXP8etQWSe0EXUk9CrrmxBma25VlfO22LEi5vP4BBqRJweT6anH024wL4Nuq72EUQdc1r87nxix3cyB5Y3Qdt3GrlRixHRcoTcSBTZdyo3Clo_uWsjZRVnGXQcbi7VwubA7Qpj__DCqsMIXS8MBox7t8nmEFYJ6JcPj983x2JZkzARO24lVqHRA9PkgWmwQ0k2cXZdY4hsvIRZok16k_Xrj5KHzO6RLbuAoG8MGu6TWyrbJncmNkRim7xq60bTmRGNoHv0pCPJ_oBMG_DQXNMKPLQGD0Xw0Bo8tAIPrcBDi5wa8FAEz0NydvR2Nho7Nr2GI1k4KBytWBLKUKVMcyaBVqauC9wEPL7PdSxhZIN0oN0kkQnQQHD9PPX5MBnoMHVVoHz2iGxkeaaeECriQOgQmKEOgOEC54V3l5RAfaUSMWe8R15XIxxJ-0cxBcpFZGIgWGQMEhmD9MheXfyLEV1ZW7A0V10qvjrHSEVfROP5p8gdjU6ODqfTCDqw27FnU62FUI-8qAwcgYPFr2ZxpvLVMnJ9D0k2X1_CC3DIuOiRxwYZTe3Cg_VA6O38qfmn5G4zJ5-RjeJqpZ4D2y2S3RLT3wGJU7HS |
linkProvider | Flying Publisher |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Comparison+of+sampling+positions+when+measuring+personal+exposure+to+solder+fume&rft.jtitle=The+Annals+of+occupational+hygiene&rft.au=SIMPSON%2C+A.+T&rft.date=2005-07-01&rft.pub=Oxford+University+Press&rft.issn=0003-4878&rft.volume=49&rft.issue=5&rft.spage=439&rft.epage=442&rft_id=info:doi/10.1093%2Fannhyg%2Fmeh107&rft.externalDBID=n%2Fa&rft.externalDocID=16980346 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0003-4878&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0003-4878&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0003-4878&client=summon |