FEA Comparison of the Mechanical Behavior of Three Dental Crown Materials: Enamel, Ceramic, and Zirconia

The restoration of endodontically treated teeth is one of the main challenges of restorative dentistry. The structure of the tooth is a complex assembly in which the materials that make it up, enamel and dentin, have very different mechanical behaviors. Therefore, finding alternative replacement mat...

Full description

Saved in:
Bibliographic Details
Published inMaterials Vol. 17; no. 3; p. 673
Main Authors Ceddia, Mario, Lamberti, Luciano, Trentadue, Bartolomeo
Format Journal Article
LanguageEnglish
Published Switzerland MDPI AG 30.01.2024
Subjects
Online AccessGet full text

Cover

Loading…
Abstract The restoration of endodontically treated teeth is one of the main challenges of restorative dentistry. The structure of the tooth is a complex assembly in which the materials that make it up, enamel and dentin, have very different mechanical behaviors. Therefore, finding alternative replacement materials for dental crowns in the area of restorative care isa highly significant challenge, since materials such as ceramic and zirconia have very different stress load resistance values. The aim of this study is to assess which material, either ceramic or zirconia, optimizes the behavior of a restored tooth under various typical clinical conditions and the masticatory load. A finite element analysis (FEA) framework is developed for this purpose. The 3D model of the restored tooth is input into the FEA software (Ansys Workbench R23)and meshed into tetrahedral elements. The presence of masticatory forces is considered: in particular, vertical, 45° inclined, and horizontal resultant forces of 280 N are applied on five contact points of the occlusal surface. The numerical results show that the maximum stress developed in the restored tooth including a ceramic crown and subject to axial load is about 39.381 MPa, which is rather close to the 62.32 MPa stress computed for the natural tooth; stresses of about 18 MPa are localized at the roots of both crown materials. In the case of the zirconia crown, the stresses are much higher than those in the ceramic crown, except for the 45° load direction, while, for the horizontal loads, the stress peak in the zirconia crown is almost three times as large as its counterpart in the ceramic crown (i.e., 163.24 MPa vs. 56.114 MPa, respectively). Therefore, the zirconia crown exhibits higher stresses than enamel and ceramic that could increase in the case of parafunctions, such as bruxism. The clinician’s choice between the two materials should be evaluated based on the patient’s medical condition.
AbstractList The restoration of endodontically treated teeth is one of the main challenges of restorative dentistry. The structure of the tooth is a complex assembly in which the materials that make it up, enamel and dentin, have very different mechanical behaviors. Therefore, finding alternative replacement materials for dental crowns in the area of restorative care isa highly significant challenge, since materials such as ceramic and zirconia have very different stress load resistance values. The aim of this study is to assess which material, either ceramic or zirconia, optimizes the behavior of a restored tooth under various typical clinical conditions and the masticatory load. A finite element analysis (FEA) framework is developed for this purpose. The 3D model of the restored tooth is input into the FEA software (Ansys Workbench R23)and meshed into tetrahedral elements. The presence of masticatory forces is considered: in particular, vertical, 45° inclined, and horizontal resultant forces of 280 N are applied on five contact points of the occlusal surface. The numerical results show that the maximum stress developed in the restored tooth including a ceramic crown and subject to axial load is about 39.381 MPa, which is rather close to the 62.32 MPa stress computed for the natural tooth; stresses of about 18 MPa are localized at the roots of both crown materials. In the case of the zirconia crown, the stresses are much higher than those in the ceramic crown, except for the 45° load direction, while, for the horizontal loads, the stress peak in the zirconia crown is almost three times as large as its counterpart in the ceramic crown (i.e., 163.24 MPa vs. 56.114 MPa, respectively). Therefore, the zirconia crown exhibits higher stresses than enamel and ceramic that could increase in the case of parafunctions, such as bruxism. The clinician’s choice between the two materials should be evaluated based on the patient’s medical condition.
The restoration of endodontically treated teeth is one of the main challenges of restorative dentistry. The structure of the tooth is a complex assembly in which the materials that make it up, enamel and dentin, have very different mechanical behaviors. Therefore, finding alternative replacement materials for dental crowns in the area of restorative care isa highly significant challenge, since materials such as ceramic and zirconia have very different stress load resistance values. The aim of this study is to assess which material, either ceramic or zirconia, optimizes the behavior of a restored tooth under various typical clinical conditions and the masticatory load. A finite element analysis (FEA) framework is developed for this purpose. The 3D model of the restored tooth is input into the FEA software (Ansys Workbench R23)and meshed into tetrahedral elements. The presence of masticatory forces is considered: in particular, vertical, 45° inclined, and horizontal resultant forces of 280 N are applied on five contact points of the occlusal surface. The numerical results show that the maximum stress developed in the restored tooth including a ceramic crown and subject to axial load is about 39.381 MPa, which is rather close to the 62.32 MPa stress computed for the natural tooth; stresses of about 18 MPa are localized at the roots of both crown materials. In the case of the zirconia crown, the stresses are much higher than those in the ceramic crown, except for the 45° load direction, while, for the horizontal loads, the stress peak in the zirconia crown is almost three times as large as its counterpart in the ceramic crown (i.e., 163.24 MPa vs. 56.114 MPa, respectively). Therefore, the zirconia crown exhibits higher stresses than enamel and ceramic that could increase in the case of parafunctions, such as bruxism. The clinician's choice between the two materials should be evaluated based on the patient's medical condition.The restoration of endodontically treated teeth is one of the main challenges of restorative dentistry. The structure of the tooth is a complex assembly in which the materials that make it up, enamel and dentin, have very different mechanical behaviors. Therefore, finding alternative replacement materials for dental crowns in the area of restorative care isa highly significant challenge, since materials such as ceramic and zirconia have very different stress load resistance values. The aim of this study is to assess which material, either ceramic or zirconia, optimizes the behavior of a restored tooth under various typical clinical conditions and the masticatory load. A finite element analysis (FEA) framework is developed for this purpose. The 3D model of the restored tooth is input into the FEA software (Ansys Workbench R23)and meshed into tetrahedral elements. The presence of masticatory forces is considered: in particular, vertical, 45° inclined, and horizontal resultant forces of 280 N are applied on five contact points of the occlusal surface. The numerical results show that the maximum stress developed in the restored tooth including a ceramic crown and subject to axial load is about 39.381 MPa, which is rather close to the 62.32 MPa stress computed for the natural tooth; stresses of about 18 MPa are localized at the roots of both crown materials. In the case of the zirconia crown, the stresses are much higher than those in the ceramic crown, except for the 45° load direction, while, for the horizontal loads, the stress peak in the zirconia crown is almost three times as large as its counterpart in the ceramic crown (i.e., 163.24 MPa vs. 56.114 MPa, respectively). Therefore, the zirconia crown exhibits higher stresses than enamel and ceramic that could increase in the case of parafunctions, such as bruxism. The clinician's choice between the two materials should be evaluated based on the patient's medical condition.
Audience Academic
Author Ceddia, Mario
Lamberti, Luciano
Trentadue, Bartolomeo
Author_xml – sequence: 1
  givenname: Mario
  surname: Ceddia
  fullname: Ceddia, Mario
– sequence: 2
  givenname: Luciano
  surname: Lamberti
  fullname: Lamberti, Luciano
– sequence: 3
  givenname: Bartolomeo
  orcidid: 0000-0002-5759-0692
  surname: Trentadue
  fullname: Trentadue, Bartolomeo
BackLink https://www.ncbi.nlm.nih.gov/pubmed/38591528$$D View this record in MEDLINE/PubMed
BookMark eNptkU1v1DAQhi1URD_ohR-ALHFBVbf4I45jbtuwBaRWXMqFSzTrjImrxN7a2Vb997ja8qEK--CR55lXM_Mekr0QAxLyhrMzKQ37MAHXTLJayxfkgBtTL7ipqr1_4n1ynPMNK0dK3gjziuzLRhmuRHNAhovVkrZx2kDyOQYaHZ0HpFdoBwjewkjPcYA7H9Nj6npIiPQThrkk2hTvA72CGZOHMX-kqwATjqe0xQSTt6cUQk9_-GRj8PCavHSFwuOn94h8v1hdt18Wl98-f22XlwtbppkXFnVla7Z20CtrdW0dWGYax6QCoVFVvVNu7SrUtheWW6Ul47yu9VqjrhWTR-T9TneT4u0W89xNPlscRwgYt7mTRYlpJRQv6Ltn6E3cplC664QR0ihdi6ZQZzvqJ4zY-eDinMCW22MZspjhfPlf6kawslMpSsHbJ9ntesK-2yQ_QXrofi-9ACc7wKaYc0L3B-GsezS1-2tqgdkz2PoZZh9DacOP_yv5BWIIoMI
CitedBy_id crossref_primary_10_1016_j_compbiomed_2024_109241
crossref_primary_10_61189_974215qcjfzk
crossref_primary_10_1111_edt_13040
crossref_primary_10_3390_jfb15070199
crossref_primary_10_3390_ma18061295
crossref_primary_10_1515_cls_2024_0015
crossref_primary_10_3390_biomimetics10020072
crossref_primary_10_3390_jsan13050052
Cites_doi 10.1016/S0278-2391(99)90437-8
10.1016/j.dental.2007.12.006
10.1007/s11517-015-1289-4
10.1016/j.dental.2006.03.013
10.1038/srep19849
10.1016/j.dental.2011.11.019
10.1007/s11914-021-00664-0
10.1016/0001-6160(73)90064-3
10.1034/j.1600-0501.2001.120614.x
10.14219/jada.archive.2009.0316
10.1177/10454411000110010101
10.1016/j.prosdent.2003.08.008
10.1016/j.dental.2020.04.022
10.20944/preprints202306.1720.v1
10.1111/jopr.12016
10.1111/ocr.12527
10.1111/jopr.12130
10.1016/j.jdent.2012.07.007
10.4047/jap.2015.7.6.475
10.3390/ma16134756
10.1016/j.dental.2003.07.002
10.1016/S0003-9969(99)00080-1
10.1016/j.clinbiomech.2007.08.024
10.1155/2017/1029574
10.4012/dmj.2016-298
10.1016/j.dental.2006.06.036
10.1016/0003-9969(95)00109-3
10.1080/10255842.2014.951927
10.1016/j.ajodo.2007.11.023
10.1016/S0021-9290(97)00131-0
10.1016/j.ajodo.2007.03.032
10.3390/osteology3040015
10.1016/S0109-5641(99)00070-6
10.1016/S1359-6454(97)00296-6
10.15406/jdhodt.2014.01.00022
10.1016/j.prosdent.2004.02.001
10.17219/acem/67441
10.1016/j.jbiomech.2008.05.017
10.1016/j.ceramint.2016.06.133
10.1016/j.jmbbm.2016.04.014
10.1016/S0021-9290(00)00069-5
10.1002/(SICI)1097-4555(199702)28:2/3<151::AID-JRS71>3.0.CO;2-5
10.1111/j.1600-0501.2007.01468.x
10.1067/mpr.2001.115251
10.1016/S0022-3913(10)60184-9
10.1002/jbm.820270605
10.1007/s10237-013-0514-z
10.1016/j.sdentj.2019.10.005
10.1016/j.dental.2008.04.015
10.1016/S0022-3913(98)70067-8
10.1111/j.1600-0722.2004.00197.x
10.1177/00220345010800021001
10.1016/j.jcms.2013.02.005
10.1016/j.prosdent.2014.06.010
10.1016/S0889-5406(03)00164-1
10.1067/mpr.2003.89
10.11607/ijp.4168
10.1146/annurev-bioeng-062117-121139
10.1016/S0300-5712(01)00040-9
10.5005/jp-journals-10024-2626
10.1177/154405910208100711
10.1007/s00784-015-1455-y
10.1103/PhysRevB.59.14202
10.1111/j.1708-8208.2011.00388.x
10.1016/j.dental.2006.06.015
ContentType Journal Article
Copyright COPYRIGHT 2024 MDPI AG
2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Copyright_xml – notice: COPYRIGHT 2024 MDPI AG
– notice: 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
DBID AAYXX
CITATION
NPM
7SR
8FD
8FE
8FG
ABJCF
ABUWG
AFKRA
AZQEC
BENPR
BGLVJ
CCPQU
D1I
DWQXO
HCIFZ
JG9
KB.
PDBOC
PHGZM
PHGZT
PIMPY
PKEHL
PQEST
PQGLB
PQQKQ
PQUKI
7X8
DOI 10.3390/ma17030673
DatabaseName CrossRef
PubMed
Engineered Materials Abstracts
Technology Research Database
ProQuest SciTech Collection
ProQuest Technology Collection
Materials Science & Engineering Collection
ProQuest Central (Alumni)
ProQuest Central UK/Ireland
ProQuest Central Essentials
ProQuest Central
Technology Collection
ProQuest One Community College
ProQuest Materials Science Collection
ProQuest Central Korea
SciTech Premium Collection
Materials Research Database
Materials Science Database
Materials Science Collection
ProQuest Central Premium
ProQuest One Academic
Publicly Available Content Database
ProQuest One Academic Middle East (New)
ProQuest One Academic Eastern Edition (DO NOT USE)
ProQuest One Applied & Life Sciences
ProQuest One Academic
ProQuest One Academic UKI Edition
MEDLINE - Academic
DatabaseTitle CrossRef
PubMed
Publicly Available Content Database
ProQuest Materials Science Collection
Materials Research Database
Technology Collection
Technology Research Database
ProQuest One Academic Middle East (New)
ProQuest Central Essentials
ProQuest One Academic Eastern Edition
Materials Science Collection
ProQuest Central (Alumni Edition)
SciTech Premium Collection
ProQuest One Community College
ProQuest Technology Collection
ProQuest SciTech Collection
ProQuest Central
ProQuest One Applied & Life Sciences
Engineered Materials Abstracts
ProQuest One Academic UKI Edition
ProQuest Central Korea
Materials Science & Engineering Collection
Materials Science Database
ProQuest Central (New)
ProQuest One Academic
ProQuest One Academic (New)
MEDLINE - Academic
DatabaseTitleList Publicly Available Content Database

MEDLINE - Academic
CrossRef
PubMed
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: 8FG
  name: ProQuest Technology Collection
  url: https://search.proquest.com/technologycollection1
  sourceTypes: Aggregation Database
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
Dentistry
EISSN 1996-1944
ExternalDocumentID A782091532
38591528
10_3390_ma17030673
Genre Journal Article
GeographicLocations United States--US
GeographicLocations_xml – name: United States--US
GroupedDBID 29M
2WC
2XV
53G
5GY
5VS
8FE
8FG
AADQD
AAFWJ
AAHBH
AAYXX
ABDBF
ABJCF
ACUHS
ADBBV
ADMLS
AENEX
AFKRA
AFZYC
ALMA_UNASSIGNED_HOLDINGS
AOIJS
BCNDV
BENPR
BGLVJ
CCPQU
CITATION
CZ9
D1I
E3Z
EBS
ESX
FRP
GX1
HCIFZ
HH5
HYE
I-F
IAO
ITC
KB.
KC.
KQ8
MK~
MODMG
M~E
OK1
OVT
P2P
PDBOC
PGMZT
PHGZM
PHGZT
PIMPY
PROAC
RPM
TR2
TUS
NPM
PQGLB
PMFND
7SR
8FD
ABUWG
AZQEC
DWQXO
JG9
PKEHL
PQEST
PQQKQ
PQUKI
7X8
ID FETCH-LOGICAL-c390t-ce74c60bfad5cc76cfac098f035a27e54df5fbf4e7cd2c1c573011667b7e76503
IEDL.DBID BENPR
ISSN 1996-1944
IngestDate Fri Jul 11 05:30:39 EDT 2025
Fri Jul 25 11:43:07 EDT 2025
Tue Jun 10 21:12:31 EDT 2025
Mon Jul 21 06:02:25 EDT 2025
Tue Jul 01 04:28:55 EDT 2025
Thu Apr 24 23:14:52 EDT 2025
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 3
Keywords dentin
finite element analysis
dental stress analysis
crown materials
prosthetic dentistry
crown
Language English
License https://creativecommons.org/licenses/by/4.0
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c390t-ce74c60bfad5cc76cfac098f035a27e54df5fbf4e7cd2c1c573011667b7e76503
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ORCID 0000-0002-5759-0692
OpenAccessLink https://www.proquest.com/docview/2923957628?pq-origsite=%requestingapplication%
PMID 38591528
PQID 2923957628
PQPubID 2032366
ParticipantIDs proquest_miscellaneous_3035075251
proquest_journals_2923957628
gale_infotracacademiconefile_A782091532
pubmed_primary_38591528
crossref_primary_10_3390_ma17030673
crossref_citationtrail_10_3390_ma17030673
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2024-Jan-30
PublicationDateYYYYMMDD 2024-01-30
PublicationDate_xml – month: 01
  year: 2024
  text: 2024-Jan-30
  day: 30
PublicationDecade 2020
PublicationPlace Switzerland
PublicationPlace_xml – name: Switzerland
– name: Basel
PublicationTitle Materials
PublicationTitleAlternate Materials (Basel)
PublicationYear 2024
Publisher MDPI AG
Publisher_xml – name: MDPI AG
References Wirtz (ref_32) 2000; 33
Blatz (ref_48) 2004; 91
Kinney (ref_11) 1999; 44
Asgar (ref_13) 1988; 23
Morgan (ref_45) 2018; 20
Kanat (ref_23) 2014; 23
Silva (ref_36) 2014; 112
Rocha (ref_68) 2011; 105
(ref_30) 2000; 11
Fathy (ref_67) 2014; 1
Moraguez (ref_55) 2015; 19
Viecilli (ref_77) 2008; 133
Jiang (ref_14) 2010; 45
ref_24
Armstrong (ref_6) 1997; 28
Mori (ref_17) 1973; 21
Huo (ref_9) 2000; 16
Sailer (ref_52) 2007; 18
Toms (ref_72) 2003; 123
Goff (ref_50) 1999; 59
Pilo (ref_59) 1998; 79
ref_27
Munari (ref_38) 2015; 53
Alla (ref_42) 2015; 3
Blatz (ref_16) 2003; 89
Gommers (ref_18) 1998; 46
Himmlova (ref_64) 2004; 91
Reich (ref_58) 2005; 113
Sorrentino (ref_62) 2016; 61
Taskonak (ref_69) 2008; 24
Ovy (ref_73) 2022; 25
Aboushelib (ref_60) 2007; 23
Magne (ref_63) 2007; 23
Su (ref_39) 2014; 13
Omur (ref_49) 2019; 28
Grzebieluch (ref_19) 2017; 26
Cattaneo (ref_75) 2021; 19
Shimizu (ref_46) 1993; 27
ref_31
Luthardt (ref_47) 2002; 81
Field (ref_76) 2009; 135
Shinno (ref_20) 2016; 6
Ogata (ref_4) 2001; 26
Geng (ref_65) 2001; 85
Son (ref_71) 2012; 40
Kosmac (ref_15) 1999; 15
Karimi (ref_74) 2020; 32
Miura (ref_37) 2009; 25
Misch (ref_44) 1999; 57
Casson (ref_61) 2001; 29
Lin (ref_57) 1998; 11
Helgason (ref_34) 2008; 23
Rocha (ref_41) 2015; 18
Kharouf (ref_3) 2019; 20
Kinney (ref_5) 1996; 41
Heydecke (ref_66) 2007; 23
Christensen (ref_2) 2009; 140
Lertchirakarn (ref_8) 2001; 80
Reddy (ref_21) 2005; 7
Schileo (ref_33) 2008; 41
Dejak (ref_43) 2012; 28
Larsson (ref_53) 2010; 23
Pallav (ref_70) 2004; 20
Bramanti (ref_22) 2017; 2017
Alhasanyah (ref_1) 2013; 22
Ceddia (ref_28) 2023; 3
Li (ref_29) 2014; 42
Alsadon (ref_51) 2017; 36
Cakan (ref_56) 2015; 28
Shahmoradi (ref_25) 2020; 36
Ha (ref_26) 2015; 7
Williams (ref_35) 2001; 12
Schwarz (ref_54) 2012; 14
Wang (ref_10) 1998; 31
Ha (ref_40) 2016; 42
Huo (ref_7) 1999; 15
Kalk (ref_12) 2011; 24
References_xml – volume: 15
  start-page: 355
  year: 1999
  ident: ref_7
  article-title: Effect of dentin tubules to the mechanical properties of dentin. Part I: Stress–strain relations and strength criterion
  publication-title: Acta Mech. Sin. (Engl. Ser.)
– volume: 57
  start-page: 700
  year: 1999
  ident: ref_44
  article-title: Mechanical properties of trabecular bone in the human mandible: Implications for dental implant treatment planning and surgical placement
  publication-title: J. Oral Maxillofac. Surg.
  doi: 10.1016/S0278-2391(99)90437-8
– volume: 24
  start-page: 1077
  year: 2008
  ident: ref_69
  article-title: Fractographic analyses of zirconia-based fixed partial dentures
  publication-title: Dent. Mater.
  doi: 10.1016/j.dental.2007.12.006
– volume: 53
  start-page: 751
  year: 2015
  ident: ref_38
  article-title: Stress distribution in a premolar 3D model with anisotropic and isotropic enamel
  publication-title: Med. Biol. Eng. Comput.
  doi: 10.1007/s11517-015-1289-4
– volume: 23
  start-page: 539
  year: 2007
  ident: ref_63
  article-title: Efficient 3D finite element analysis of dental restorative procedures using micro-CT data
  publication-title: Dent. Mater.
  doi: 10.1016/j.dental.2006.03.013
– volume: 16
  start-page: 75
  year: 2000
  ident: ref_9
  article-title: Effect of dentin tubules to the mechanical properties of dentin. Part II: Experimental study
  publication-title: Acta Mech. Sin. (Engl. Ser.)
– volume: 6
  start-page: 19849
  year: 2016
  ident: ref_20
  article-title: Comprehensive analyses of how tubule occlusion and advanced glycation end-products diminish strength of aged dentin
  publication-title: Sci. Rep.
  doi: 10.1038/srep19849
– volume: 28
  start-page: 433
  year: 2012
  ident: ref_43
  article-title: Three-dimensional finite element analysis of molars with thin-walled prosthetic crowns made of various materials
  publication-title: Dent. Mater.
  doi: 10.1016/j.dental.2011.11.019
– volume: 19
  start-page: 175
  year: 2021
  ident: ref_75
  article-title: Orthodontic tooth movement studied by finite element analysis: An update. What can we learn from these simulations?
  publication-title: Curr. Osteoporos. Rep.
  doi: 10.1007/s11914-021-00664-0
– volume: 21
  start-page: 571
  year: 1973
  ident: ref_17
  article-title: Average stress in matrix and average elastic energy of materials with misfitting inclusions
  publication-title: Acta Metall.
  doi: 10.1016/0001-6160(73)90064-3
– volume: 12
  start-page: 648
  year: 2001
  ident: ref_35
  article-title: Anisotropic elasticity of cortical and cancellous bone in the posterior mandible increases peri-implant stress and strain under oblique loading
  publication-title: Clin. Oral. Implant. Res.
  doi: 10.1034/j.1600-0501.2001.120614.x
– volume: 140
  start-page: 1036
  year: 2009
  ident: ref_2
  article-title: Porcelain-fused-to-metal versus zirconia based ceramic restorations
  publication-title: J. Am. Dent. Assoc.
  doi: 10.14219/jada.archive.2009.0316
– volume: 11
  start-page: 123
  year: 2000
  ident: ref_30
  article-title: Biomechanics of the mandible
  publication-title: Crit. Rev. Oral Biol. Med.
  doi: 10.1177/10454411000110010101
– volume: 91
  start-page: 20
  year: 2004
  ident: ref_64
  article-title: Influence of implant length and diameter on stress distribution: A finite element analysis
  publication-title: J. Prosthet. Dent.
  doi: 10.1016/j.prosdent.2003.08.008
– volume: 36
  start-page: 1038
  year: 2020
  ident: ref_25
  article-title: Monolithic crowns fracture analysis: The effect of material properties, cusp angle and crown thickness
  publication-title: Dent. Mater.
  doi: 10.1016/j.dental.2020.04.022
– ident: ref_27
  doi: 10.20944/preprints202306.1720.v1
– volume: 22
  start-page: 383
  year: 2013
  ident: ref_1
  article-title: Effect of core thickness differences on post-fatigue indentation fracture resistance of veneered zirconia crowns
  publication-title: J. Prosthodont.
  doi: 10.1111/jopr.12016
– volume: 25
  start-page: 199
  year: 2022
  ident: ref_73
  article-title: Modelling and evaluating periodontal ligament mechanical behaviour and properties: A scoping review of current approaches and limitations
  publication-title: Orthod. Craniofac. Res.
  doi: 10.1111/ocr.12527
– volume: 23
  start-page: 445
  year: 2014
  ident: ref_23
  article-title: Effect of various veneering techniques on mechanical strength of computer-controlled zirconia framework designs
  publication-title: J. Prosthodont.
  doi: 10.1111/jopr.12130
– volume: 3
  start-page: 13
  year: 2015
  ident: ref_42
  article-title: Dental ceramics: Part I—An overview of composition, structure and properties
  publication-title: Am. J. Mater. Eng. Technol.
– volume: 40
  start-page: 866
  year: 2012
  ident: ref_71
  article-title: Influence of internal-gap width and cement type on the retentive force of zirconia copings in pullout testing
  publication-title: J. Dent.
  doi: 10.1016/j.jdent.2012.07.007
– volume: 7
  start-page: 475
  year: 2015
  ident: ref_26
  article-title: Biomechanical three-dimensional finite element analysis of monolithic zirconia crown with different cement type
  publication-title: J. Adv. Prosthodont.
  doi: 10.4047/jap.2015.7.6.475
– ident: ref_31
– volume: 11
  start-page: 580
  year: 1998
  ident: ref_57
  article-title: The effect of tooth preparation form on the fit of Procera copings
  publication-title: Int. J. Prosthodont.
– ident: ref_24
  doi: 10.3390/ma16134756
– volume: 20
  start-page: 457
  year: 2004
  ident: ref_70
  article-title: The apparent increase of the Young’s modulus in thin cement layers
  publication-title: Dent. Mater.
  doi: 10.1016/j.dental.2003.07.002
– volume: 44
  start-page: 813
  year: 1999
  ident: ref_11
  article-title: A micromechanics model of the elastic properties of human dentine
  publication-title: Arch. Oral Biol.
  doi: 10.1016/S0003-9969(99)00080-1
– volume: 23
  start-page: 135
  year: 2008
  ident: ref_34
  article-title: Mathematical relationships between bone density and mechanical properties: A literature review
  publication-title: Clin. Biomech.
  doi: 10.1016/j.clinbiomech.2007.08.024
– volume: 2017
  start-page: 1029574
  year: 2017
  ident: ref_22
  article-title: FEM and Von Mises analysis on prosthetic crowns structural elements: Evaluation of different applied materials
  publication-title: Sci. World J.
  doi: 10.1155/2017/1029574
– volume: 36
  start-page: 289
  year: 2017
  ident: ref_51
  article-title: Fracture resistance of zirconia-composite veneered crowns in comparison with zirconia-porcelain crowns
  publication-title: Dent. Mater. J.
  doi: 10.4012/dmj.2016-298
– volume: 23
  start-page: 952
  year: 2007
  ident: ref_60
  article-title: Effect of loading method on the fracture mechanics of two layered all-ceramic restorative systems
  publication-title: Dent. Mater.
  doi: 10.1016/j.dental.2006.06.036
– volume: 41
  start-page: 9
  year: 1996
  ident: ref_5
  article-title: Hardness and Young’s modulus of human peritubular and intertubular dentine
  publication-title: Arch. Oral Biol.
  doi: 10.1016/0003-9969(95)00109-3
– volume: 18
  start-page: 1744
  year: 2015
  ident: ref_41
  article-title: Zirconia-based dental crown to support a removable partial denture: A three-dimensional finite element analysis using contact elements and micro-CT data
  publication-title: Comput. Methods Biomech. Biomed. Eng.
  doi: 10.1080/10255842.2014.951927
– volume: 133
  start-page: 791.e11
  year: 2008
  ident: ref_77
  article-title: Three-dimensional mechanical environment of orthodontic tooth movement and root resorption
  publication-title: Am. J. Orthod. Dentofac. Orthop.
  doi: 10.1016/j.ajodo.2007.11.023
– volume: 31
  start-page: 135
  year: 1998
  ident: ref_10
  article-title: Strain–structure relations in human teeth using moiré fringes
  publication-title: J. Biomech.
  doi: 10.1016/S0021-9290(97)00131-0
– volume: 135
  start-page: 174
  year: 2009
  ident: ref_76
  article-title: Mechanical responses to orthodontic loading: A 3-dimensional finite element multi-tooth model
  publication-title: Am. J. Orthod. Dentofac. Orthop.
  doi: 10.1016/j.ajodo.2007.03.032
– volume: 7
  start-page: 102
  year: 2005
  ident: ref_21
  article-title: Three-dimensional finite element analysis of stress in the periodontium
  publication-title: J. Int. Acad. Periodontol.
– volume: 3
  start-page: 140
  year: 2023
  ident: ref_28
  article-title: Finite Element Analysis (FEA) for the evaluation of retention in a Conometric Connection for Implant and Prosthesis
  publication-title: Osteology
  doi: 10.3390/osteology3040015
– volume: 15
  start-page: 426
  year: 1999
  ident: ref_15
  article-title: The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic
  publication-title: Dent. Mater.
  doi: 10.1016/S0109-5641(99)00070-6
– volume: 46
  start-page: 2223
  year: 1998
  ident: ref_18
  article-title: The Mori-Tanaka method applied to textile composite materials
  publication-title: Acta Mater.
  doi: 10.1016/S1359-6454(97)00296-6
– volume: 1
  start-page: 89
  year: 2014
  ident: ref_67
  article-title: Three-dimensional finite element analysis of lower molar tooth restored with fully milled and layered zirconia crowns
  publication-title: J. Dent. Health Oral Disord. Ther.
  doi: 10.15406/jdhodt.2014.01.00022
– volume: 91
  start-page: 356
  year: 2004
  ident: ref_48
  article-title: In vitro evaluation of shear bond strengths of resin to densely sintered high-purity zirconium-oxide ceramic after long-term storage and thermal cycling
  publication-title: J. Prosthet. Dent.
  doi: 10.1016/j.prosdent.2004.02.001
– volume: 23
  start-page: 555
  year: 2010
  ident: ref_53
  article-title: Five-year follow-up of implant-supported Y-TZP and ZTA fixed dental prostheses. A randomized, prospective clinical trial comparing two different material systems
  publication-title: Int. J. Prosthodont.
– volume: 26
  start-page: 645
  year: 2017
  ident: ref_19
  article-title: The mechanical properties of human dentin for 3-D finite element modeling: Numerical and analytical evaluation
  publication-title: Adv. Clin. Exp. Med.
  doi: 10.17219/acem/67441
– volume: 41
  start-page: 2483
  year: 2008
  ident: ref_33
  article-title: An accurate estimation of bone density improves the accuracy of subject-specific finite element models
  publication-title: J. Biomech.
  doi: 10.1016/j.jbiomech.2008.05.017
– volume: 42
  start-page: 14928
  year: 2016
  ident: ref_40
  article-title: Biomechanical three dimensional finite element analysis of monolithic zirconia crown with different cement thickness
  publication-title: Ceram. Int.
  doi: 10.1016/j.ceramint.2016.06.133
– volume: 26
  start-page: 27
  year: 2001
  ident: ref_4
  article-title: Influence of the direction of tubules on bond strength to dentin
  publication-title: Oper. Dent.
– volume: 61
  start-page: 328
  year: 2016
  ident: ref_62
  article-title: In vitro analysis of the fracture resistance of CAD-CAM monolithic zirconia molar crowns with different occlusal thickness
  publication-title: J. Mech. Behav. Biomed. Mater.
  doi: 10.1016/j.jmbbm.2016.04.014
– volume: 33
  start-page: 1325
  year: 2000
  ident: ref_32
  article-title: Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur
  publication-title: J. Biomech.
  doi: 10.1016/S0021-9290(00)00069-5
– volume: 28
  start-page: 151
  year: 1997
  ident: ref_6
  article-title: Fourier transform Raman microscopic mapping of the molecular components in a human tooth
  publication-title: J. Raman Spectrosc.
  doi: 10.1002/(SICI)1097-4555(199702)28:2/3<151::AID-JRS71>3.0.CO;2-5
– volume: 18
  start-page: 86
  year: 2007
  ident: ref_52
  article-title: A systematic review of the survival and complication rates of all ceramic and metal–ceramic reconstructions after an observation period of at least 3 years. Part II: Fixed dental prostheses
  publication-title: Clin. Oral Implant. Res.
  doi: 10.1111/j.1600-0501.2007.01468.x
– volume: 85
  start-page: 585
  year: 2001
  ident: ref_65
  article-title: Application of finite element analysis in implant dentistry: A review of the literature
  publication-title: J. Prosthet. Dent.
  doi: 10.1067/mpr.2001.115251
– volume: 105
  start-page: 14
  year: 2011
  ident: ref_68
  article-title: Mechanical behavior of ceramic veneer in zirconia-based restorations: A 3-dimensional finite element analysis using microcomputed tomography data
  publication-title: J. Prosthet. Dent.
  doi: 10.1016/S0022-3913(10)60184-9
– volume: 27
  start-page: 729
  year: 1993
  ident: ref_46
  article-title: Time-dependent changes in the mechanical properties of zirconia ceramic
  publication-title: J. Biomed. Mater. Res.
  doi: 10.1002/jbm.820270605
– volume: 13
  start-page: 527
  year: 2014
  ident: ref_39
  article-title: An investigation of dentinal fluid flow in dental pulp during food mastication: Simulation of fluid–structure interaction
  publication-title: Biomech. Model. Mechanobiol.
  doi: 10.1007/s10237-013-0514-z
– volume: 32
  start-page: 349
  year: 2020
  ident: ref_74
  article-title: Finite element modeling of the periodontal ligament under a realistic kinetic loading of the jaw system
  publication-title: Saudi Dent. J.
  doi: 10.1016/j.sdentj.2019.10.005
– volume: 25
  start-page: 67
  year: 2009
  ident: ref_37
  article-title: Multiscale analysis of stress distribution in teeth under applied forces
  publication-title: Dent. Mater.
  doi: 10.1016/j.dental.2008.04.015
– volume: 79
  start-page: 621
  year: 1998
  ident: ref_59
  article-title: In vivo retrospective study of cement thickness under crowns
  publication-title: J. Prosthet. Dent.
  doi: 10.1016/S0022-3913(98)70067-8
– volume: 113
  start-page: 174
  year: 2005
  ident: ref_58
  article-title: Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems
  publication-title: Eur. J. Oral Sci.
  doi: 10.1111/j.1600-0722.2004.00197.x
– volume: 80
  start-page: 453
  year: 2001
  ident: ref_8
  article-title: Anisotropy of tensile strength of root dentin
  publication-title: J. Dent. Res.
  doi: 10.1177/00220345010800021001
– volume: 42
  start-page: 73
  year: 2014
  ident: ref_29
  article-title: Optimal design of an individual endoprosthesis for the reconstruction of extensive mandibular defects with finite element analysis
  publication-title: J. Cranio-Maxillofac. Surg.
  doi: 10.1016/j.jcms.2013.02.005
– volume: 112
  start-page: 1479
  year: 2014
  ident: ref_36
  article-title: Biomechanical evaluation of screw- and cement-retained implant-supported prostheses: A nonlinear finite element analysis
  publication-title: J. Prosthet. Dent.
  doi: 10.1016/j.prosdent.2014.06.010
– volume: 123
  start-page: 657
  year: 2003
  ident: ref_72
  article-title: A nonlinear finite element analysis of the periodontal ligament under orthodontic tooth loading
  publication-title: Am. J. Orthod. Dentofac. Orthop.
  doi: 10.1016/S0889-5406(03)00164-1
– volume: 28
  start-page: e186
  year: 2019
  ident: ref_49
  article-title: Effects of silica coating by physical vapor deposition and repeated firing on the low temperature degradation and flexural strength of a zirconia ceramic
  publication-title: J. Prosthodont.
– volume: 89
  start-page: 381
  year: 2003
  ident: ref_16
  article-title: In vitro evaluation of long-term bonding of ProceraAllCeram alumina restorations with a modified resin luting agent
  publication-title: J. Prosthet. Dent.
  doi: 10.1067/mpr.2003.89
– volume: 28
  start-page: 152
  year: 2015
  ident: ref_56
  article-title: Zirconia-based crowns up to 5 years in function: A retrospective clinical study and evaluation of prosthetic restorations and failures
  publication-title: Int. J. Prosthodont.
  doi: 10.11607/ijp.4168
– volume: 20
  start-page: 119
  year: 2018
  ident: ref_45
  article-title: Bone mechanical properties in healthy and diseased states
  publication-title: Annu. Rev. Biomed. Eng.
  doi: 10.1146/annurev-bioeng-062117-121139
– volume: 29
  start-page: 539
  year: 2001
  ident: ref_61
  article-title: The effect of luting media on the fracture resistance of a flame sprayed all-ceramic crown
  publication-title: J. Dent.
  doi: 10.1016/S0300-5712(01)00040-9
– volume: 20
  start-page: 915
  year: 2019
  ident: ref_3
  article-title: Effectiveness of etching by three acids on the morphological and chemical features of dentin tissue
  publication-title: J. Contemp. Dent. Pract.
  doi: 10.5005/jp-journals-10024-2626
– volume: 81
  start-page: 487
  year: 2002
  ident: ref_47
  article-title: Reliability and properties of ground Y-TZP-zirconia ceramics
  publication-title: J. Dent. Res.
  doi: 10.1177/154405910208100711
– volume: 23
  start-page: 3
  year: 1988
  ident: ref_13
  article-title: Casting metals in dentistry: Past present future
  publication-title: Adv. Dent. Res.
– volume: 19
  start-page: 2295
  year: 2015
  ident: ref_55
  article-title: Three-to nine-year survival estimates and fracture mechanisms of zirconia-and alumina-based restorations using standardized criteria to distinguish the severity of ceramic fractures
  publication-title: Clin. Oral Investig.
  doi: 10.1007/s00784-015-1455-y
– volume: 24
  start-page: 566
  year: 2011
  ident: ref_12
  article-title: A systematic review of ceramic inlays in posterior teeth: An update
  publication-title: Int. J. Prosthodont.
– volume: 45
  start-page: 376
  year: 2010
  ident: ref_14
  article-title: Zhonghua kou qiang yi xue za zhi = Zhonghua kouqiang yixue zazhi
  publication-title: Chin. J. Stomatol.
– volume: 59
  start-page: 14202
  year: 1999
  ident: ref_50
  article-title: Defect structure of yttria stabilized zirconia and its influence on the ionic conductivity at elevated temperatures
  publication-title: Phys. Rev. B
  doi: 10.1103/PhysRevB.59.14202
– volume: 14
  start-page: e119
  year: 2012
  ident: ref_54
  article-title: Survival and chipping of zirconia based and metal–ceramic implant supported single crowns
  publication-title: Clin. Implant. Dent. Relat. Res.
  doi: 10.1111/j.1708-8208.2011.00388.x
– volume: 23
  start-page: 785
  year: 2007
  ident: ref_66
  article-title: Material characteristics of a novel shrinkage-free ZrSiO4 ceramic for the fabrication of posterior crowns
  publication-title: Dent. Mater.
  doi: 10.1016/j.dental.2006.06.015
SSID ssj0000331829
Score 2.4334095
Snippet The restoration of endodontically treated teeth is one of the main challenges of restorative dentistry. The structure of the tooth is a complex assembly in...
SourceID proquest
gale
pubmed
crossref
SourceType Aggregation Database
Index Database
Enrichment Source
StartPage 673
SubjectTerms Axial loads
Biomechanics
Ceramics
Comparative analysis
Crack propagation
Dental crowns
Dental enamel
Dental materials
Dentin
Dentistry
Finite element method
Load resistance
Mastication
Mechanical properties
Prostheses
Stresses
Teeth
Three dimensional models
Zirconium dioxide
Zirconium oxide
Title FEA Comparison of the Mechanical Behavior of Three Dental Crown Materials: Enamel, Ceramic, and Zirconia
URI https://www.ncbi.nlm.nih.gov/pubmed/38591528
https://www.proquest.com/docview/2923957628
https://www.proquest.com/docview/3035075251
Volume 17
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV3da9swED_W9GHbw9i6L_cLjQ3GoKa2bFlyX0aWJi2DlDFaCHsxsj5YoXXaJP3_d2cr7lrGHo2EkHWn0-_upN8BfPIWDb_kJiaq7zhXuoxrkfkYDSaeEM6mVlNGd3pWnF7k32diFgJuy3Ctcm0TW0Nt54Zi5IcckUiJ4Jirrze3MVWNouxqKKGxAZtogpUawOa38dmPn32UJclQZ3nZ8ZJm6N8fXutUtjg5e3ASPbbHj1Bme9pMXsKLABPZsJPrK3jimi14ekxXe6g62xY8_4tI8DX8noyHbNSXFGRzzxDYsamjd70kBhZ4EBfUdI7yc-y4fQjJRuSHs6ledap4xMaNvnZXB2zkFlSr_oDpxrJflwt0nC_1G7iYjM9Hp3GooRAb_NtVbJzMTZHUXlthjCyM1yYplU8yobl0Irde-NrnThrLTWpEu-OLQtbSSURv2VsYNPPGvQemvC5tYqQscEyfSq25VaU09JTWSZlG8GW9npUJBONU5-KqQkeD1r66X_sIPvZ9bzpajX_2-kxiqWiv4UhGhycDOB9iraqGRPZXos3mEeyuJVeFTbis7lUmgg99M24fyonoxs3vllVGmVUpEOVF8K6TeD-hjLj9BFfb_x98B55xVHiKy2TJLgxWizu3h0hlVe_Dhpqc7AelxK-TWfoHRfHoqQ
linkProvider ProQuest
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1baxQxFD7U-lD7IFpvo1UjKiJ06EzmkhlBZNmLW9vt0xaKLzGTC13oztbdLeKf8jd6ztyqRXzrc0IIObfvJDnfAXjjDDp-wbVPVN9-nKncL5LI-egwMUJYExpFL7qT43R8En85TU434FdbC0PfKlufWDlqs9B0R77PEYnkCI559uniu09do-h1tW2hUavFof35A1O21ceDAcr3Leej4bQ_9puuAr7G_H7taytinQaFUybRWqTaKR3kmQuiRHFhk9i4xBUutkIbrkOdVDaQpqIQViCeiXDdW3A7jjCSU2X66HN3pxNEaCE8r1lQcTzYn6tQVKg8-ivuXff-1zBtFdtG9-BuA0pZr9ai-7Bhyx3YGtBHIuoFtwPbf9AWPoCz0bDH-l0DQ7ZwDGEkm1iqIiahs4Z1cUlDU9QWywZV2SXrU9bPJmpdK_4HNizV3J7vsb5dqvlM7zFVGvZ1tsQ0faYewsmNnO0j2CwXpX0CLHMqN4EWIsU1XSiU4ibLhabCXStE6MH79jylbujMqavGucS0hs5eXp29B6-7uRc1icc_Z70jsUiybFxJq6ZAAfdDHFmyR9SCOUYI7sFuKznZmPxKXimoB6-6YTRWeoFRpV1crmRE77giQUzpweNa4t2GImISTHj29P-Lv4St8XRyJI8Ojg-fwR2OpkY3QlGwC5vr5aV9jhhpXbyoFJPBt5u2hN_UciOp
linkToPdf http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1ZaxRBEC7iBjweROM1GrVFRQIZdqbn6BlBZN2DxLhLkASCL2NPH7iQnY27G0L-Wn5dquaKBvEtz9P0NNV1fNXd9RXAO6vR8QuuXKL6dsNEpm4eBdZFh4kRwmhfS7rRHU_incPw61F0tAYXTS0MPatsfGLpqPVc0Rl5lyMSSREc86Rr62cR-4PR55PfLnWQopvWpp1GpSJ75vwM07flp90B7vV7zkfDg_6OW3cYcBXm-itXGRGq2Mut1JFSIlZWKi9NrBdEkgsThdpGNrehEUpz5auotIc4FrkwArFNgPPegnVBWVEH1r8MJ_vf2xMeL0B74WnFiRrg_7oz6YsSowd_RcHrseAawi0j3egB3K8hKutVOvUQ1kyxAXcG9KyIOsNtwL0_SAwfwa_RsMf6bTtDNrcMQSUbG6opJhVgNQfjgj4doO4YNiiLMFmfzgDYWK4qM_jIhoWcmeNt1jcLOZuqbSYLzX5MF5i0T-VjOLwR6T6BTjEvzDNgiZWp9pQQMc5pfSEl10kqFJXxGiF8B7YaeWaqJjenHhvHGSY5JPvsSvYOvG3HnlSUHv8c9YG2JSM7x5mUrMsVcD3EmJX1iGgwxXjBHdhsdi6rHcAyu1JXB960n9F06T5GFmZ-uswCutUVESJMB55WO94uKCBewYgnz_8_-Wu4jVaQfdud7L2Auxztjo6HAm8TOqvFqXmJgGmVv6o1k8HPmzaGSyvXKTs
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=FEA+Comparison+of+the+Mechanical+Behavior+of+Three+Dental+Crown+Materials%3A+Enamel%2C+Ceramic%2C+and+Zirconia&rft.jtitle=Materials&rft.au=Ceddia%2C+Mario&rft.au=Lambe&rft.au=Trentadue%2C+Bartolomeo&rft.date=2024-01-30&rft.pub=MDPI+AG&rft.issn=1996-1944&rft.eissn=1996-1944&rft.volume=17&rft.issue=3&rft_id=info:doi/10.3390%2Fma17030673&rft.externalDocID=A782091532
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1996-1944&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1996-1944&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1996-1944&client=summon