Endoscopic bridge operating-guide device applied for intracorporeal antegrade ureteric stenting during laparoscopic pyeloplasty
To describe our novel technique of laparoscopic pyeloplasty with an antegrade placement of a ureteral stent with a bridge operating-guide device (BOGD). After completing the posterior suture line of the dismembered pyeloplasty, a guidewire is inserted through the BOGD and grasped within the renal pe...
Saved in:
Published in | Journal of endourology Vol. 23; no. 11; p. 1871 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
United States
01.11.2009
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Abstract | To describe our novel technique of laparoscopic pyeloplasty with an antegrade placement of a ureteral stent with a bridge operating-guide device (BOGD).
After completing the posterior suture line of the dismembered pyeloplasty, a guidewire is inserted through the BOGD and grasped within the renal pelvis. Then, the BOGD is removed and the ureteral stent advanced until it is positioned in the renal pelvis, and the lower end of the stent lies in the bladder. The anastomosis is completed. Fifteen patients underwent the laparoscopic placement of ureteral stents with this technique.
With this method, the ureteral stent insertion is very convenient and time saving (the mean time for inserting a stent was 5 minutes). The stents were successfully inserted in all patients.
This technique is reliable and effective in laparoscopic ureteral operations. It uses an endoscopic urological equipment, and costs are reduced. |
---|---|
AbstractList | To describe our novel technique of laparoscopic pyeloplasty with an antegrade placement of a ureteral stent with a bridge operating-guide device (BOGD).
After completing the posterior suture line of the dismembered pyeloplasty, a guidewire is inserted through the BOGD and grasped within the renal pelvis. Then, the BOGD is removed and the ureteral stent advanced until it is positioned in the renal pelvis, and the lower end of the stent lies in the bladder. The anastomosis is completed. Fifteen patients underwent the laparoscopic placement of ureteral stents with this technique.
With this method, the ureteral stent insertion is very convenient and time saving (the mean time for inserting a stent was 5 minutes). The stents were successfully inserted in all patients.
This technique is reliable and effective in laparoscopic ureteral operations. It uses an endoscopic urological equipment, and costs are reduced. |
Author | El Atat, Rabii Derouiche, Amine Chebil, Mohamed Ben Slama, Mohamed Riadh |
Author_xml | – sequence: 1 givenname: Amine surname: Derouiche fullname: Derouiche, Amine organization: Department of Urology, Charles Nicolle Hospital, Tunis, Tunisia – sequence: 2 givenname: Rabii surname: El Atat fullname: El Atat, Rabii – sequence: 3 givenname: Mohamed Riadh surname: Ben Slama fullname: Ben Slama, Mohamed Riadh – sequence: 4 givenname: Mohamed surname: Chebil fullname: Chebil, Mohamed |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/19619061$$D View this record in MEDLINE/PubMed |
BookMark | eNo1kEtLAzEURoMo9qFLt5I_MPUmmZlOllLqAwpuFNyVO8ntEJkmIZMRuvKv26Jdnc3HOfDN2KUPnhi7E7AQ0OgH8nYhAfQCoJYXbCqqallogM8Jmw3DF4BQtVDXbCJ0LTTUYsp-1t6GwYToDG-Tsx3xEClhdr4rutFZ4pa-nSGOMfaOLN-FxJ3PCU1IMSTCnqPP1CU8bsdEmdLRNWTyJwe3Yzqhx4jpHIoH6kPscciHG3a1w36g23_O2cfT-n31Umzenl9Xj5vCqEbngkjgThlaVo2gxlZSQEkoSVuoKhS6lQraemlKpYRVVYllbZQy0hpjwdZSztn9nzeO7Z7sNia3x3TYnp-Qvyx1ZFI |
CitedBy_id | crossref_primary_10_1089_vid_2015_0019 crossref_primary_10_1089_end_2014_0208 crossref_primary_10_1089_end_2011_0168 crossref_primary_10_1089_end_2014_0458 crossref_primary_10_1016_j_jpurol_2010_10_010 crossref_primary_10_1007_s11255_017_1560_8 crossref_primary_10_1016_j_eururo_2013_06_053 |
ContentType | Journal Article |
DBID | CGR CUY CVF ECM EIF NPM |
DOI | 10.1089/end.2009.0062 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1557-900X |
ExternalDocumentID | 19619061 |
Genre | Clinical Trial Journal Article |
GroupedDBID | --- .GJ 0R~ 29K 34G 39C 4.4 53G 5GY 5RE ABBKN ACGFS ADBBV AENEX ALMA_UNASSIGNED_HOLDINGS BNQNF CAG CGR COF CS3 CUY CVF D-I DU5 EBS ECM EIF EJD EMOBN F5P I4R IAO IER IHR IM4 ITC MV1 NPM NQHIM O9- P2P RIG RML RMSOB UE5 |
ID | FETCH-LOGICAL-c389t-ee1af3ce7581e8d52104ea2e9d055a19b230b67c4331d354a46c33c2dccd0d622 |
IngestDate | Sat Sep 28 07:54:11 EDT 2024 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 11 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c389t-ee1af3ce7581e8d52104ea2e9d055a19b230b67c4331d354a46c33c2dccd0d622 |
PMID | 19619061 |
ParticipantIDs | pubmed_primary_19619061 |
PublicationCentury | 2000 |
PublicationDate | 2009-11-01 |
PublicationDateYYYYMMDD | 2009-11-01 |
PublicationDate_xml | – month: 11 year: 2009 text: 2009-11-01 day: 01 |
PublicationDecade | 2000 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Journal of endourology |
PublicationTitleAlternate | J Endourol |
PublicationYear | 2009 |
SSID | ssj0013613 |
Score | 1.9637685 |
Snippet | To describe our novel technique of laparoscopic pyeloplasty with an antegrade placement of a ureteral stent with a bridge operating-guide device (BOGD).
After... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 1871 |
SubjectTerms | Adolescent Adult Anastomosis, Surgical Female Humans Laparoscopy Male Preoperative Care Reconstructive Surgical Procedures - instrumentation Stents Surgical Instruments Ureter - surgery Young Adult |
Title | Endoscopic bridge operating-guide device applied for intracorporeal antegrade ureteric stenting during laparoscopic pyeloplasty |
URI | https://www.ncbi.nlm.nih.gov/pubmed/19619061 |
Volume | 23 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3JjtQwELV6QEJcEPuwygduo0AWZzuiodEIqeeAZqS-jRy7wkRiOq0oOcCFP-IbeV7SkzQglksUxZ20lXp5fi5XlRl7VeQ6rMMqDWJookAQPsVKJCIQIEJRxEmd1MbfsTrNTs7Fh3W6Xiy-T6KWhr56rb7-Mq_kf6yKa7CryZL9B8vuHooLOId9cYSFcfwrGy83ujVpJY068olX7dYUScZwFHwaGm1zohqTEuC1Zm2jz_sONGgKGJMtFGDrReC3Q2dCY_AsGN7tH-FzGD9jQO3GP9p-MUFG0Nz9bEF4ImwJvRq6mbv-HXXtYIJOLRVdTdbyl0AI9K61tKyaZuceIPAO0Gq17aq9lBi1jz42Uu_c18eXVDkHtm-eOTBKn8lnxx9PumkelGG4nrKyy0Ie0RdNODYq3KYtP5F_WJQWBnosQ-p4fgKE7ZVFAlgHOiiL_ty6V4t7bDpgB3lh-PTU-IbGNSsoI1_FFT15M-uHrU3r7t2bv1gdc3aX3fF24m8dmu6xBW3us1srH2LxgH27BhV3oOJ7oOIOVNyDigNUfA4qvgMVH0HFR1BxByo-BRWfgOohO3-_PDs-CfwuHYGC2O0DokjWiSJMPCMqNORgKEjGVOowTWVUVpjkVlmuTGqeTlIhRaaSRMVaKR3qLI4fsRubdkOHjAvMps18Pc5yEjKSUulUppRVmmxQ5BP22L26i60rxXIxvtSnv215xm5fg-45u1nj26cXEJJ99dLa7weszHty |
link.rule.ids | 786 |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Endoscopic+bridge+operating-guide+device+applied+for+intracorporeal+antegrade+ureteric+stenting+during+laparoscopic+pyeloplasty&rft.jtitle=Journal+of+endourology&rft.au=Derouiche%2C+Amine&rft.au=El+Atat%2C+Rabii&rft.au=Ben+Slama%2C+Mohamed+Riadh&rft.au=Chebil%2C+Mohamed&rft.date=2009-11-01&rft.eissn=1557-900X&rft.volume=23&rft.issue=11&rft.spage=1871&rft_id=info:doi/10.1089%2Fend.2009.0062&rft_id=info%3Apmid%2F19619061&rft_id=info%3Apmid%2F19619061&rft.externalDocID=19619061 |