Central arterial pulse waveform acquisition with a portable pen-like optical fiber sensor

Pulse waveform features related to cardiovascular pathologies and arterial stiffness have been extensively studied, and optical fiber sensors have been studied with an aim to simplify the pulse waveform acquisition in the carotid artery. In this paper, a novel optical fiber sensor to record pulse wa...

Full description

Saved in:
Bibliographic Details
Published inBlood pressure monitoring Vol. 20; no. 1; p. 43
Main Authors Leitão, Cátia, Antunes, Paulo, André, Paulo, Pinto, João L, Bastos, José M
Format Journal Article
LanguageEnglish
Published England 01.02.2015
Subjects
Online AccessGet more information
ISSN1473-5725
DOI10.1097/MBP.0000000000000079

Cover

Loading…
Abstract Pulse waveform features related to cardiovascular pathologies and arterial stiffness have been extensively studied, and optical fiber sensors have been studied with an aim to simplify the pulse waveform acquisition in the carotid artery. In this paper, a novel optical fiber sensor to record pulse waveform in the carotid artery has been proposed. The pulse waveform optical fiber sensor design, based on fiber Bragg gratings, is presented. The probe was characterized, and its response to controlled waveforms was studied. Finally, tests were performed on human subjects. The developed sensor has a displacement sensitivity of 21.2 pm/μm, with ability to detect the carotid pulse wave in the neck surface, with a resolution of 1.3 mmHg. This study revealed a new technological approach for acquisition of the central pulse waveform.
AbstractList Pulse waveform features related to cardiovascular pathologies and arterial stiffness have been extensively studied, and optical fiber sensors have been studied with an aim to simplify the pulse waveform acquisition in the carotid artery. In this paper, a novel optical fiber sensor to record pulse waveform in the carotid artery has been proposed. The pulse waveform optical fiber sensor design, based on fiber Bragg gratings, is presented. The probe was characterized, and its response to controlled waveforms was studied. Finally, tests were performed on human subjects. The developed sensor has a displacement sensitivity of 21.2 pm/μm, with ability to detect the carotid pulse wave in the neck surface, with a resolution of 1.3 mmHg. This study revealed a new technological approach for acquisition of the central pulse waveform.
Author André, Paulo
Antunes, Paulo
Pinto, João L
Leitão, Cátia
Bastos, José M
Author_xml – sequence: 1
  givenname: Cátia
  surname: Leitão
  fullname: Leitão, Cátia
  organization: aI3N, University of Aveiro bDepartment of Physics, University of Aveiro cInstituto de Telecomunicações, Aveiro dInstituto de Telecomunicações and Department of Electrical and Computer Engineering, Instituto Superior Técnico, Technical University of Lisbon eSchool of Health, University of Aveiro, Portugal
– sequence: 2
  givenname: Paulo
  surname: Antunes
  fullname: Antunes, Paulo
– sequence: 3
  givenname: Paulo
  surname: André
  fullname: André, Paulo
– sequence: 4
  givenname: João L
  surname: Pinto
  fullname: Pinto, João L
– sequence: 5
  givenname: José M
  surname: Bastos
  fullname: Bastos, José M
BackLink https://www.ncbi.nlm.nih.gov/pubmed/25115621$$D View this record in MEDLINE/PubMed
BookMark eNpVj8tOwzAURC0Eog_4A4T8Aym-duPbLCGigFQEC1iwqmz3WhjywnGo-HsiAQtmM7M5R5oZO2zahhg7A7EAUeDF_dXjQvwLFgdsCktUWY4yn7BZ378JAXqFeMwmMgfItYQpeympSdFU3MREMYyjG6qe-N58km9jzY37GEIfUmgbvg_plRvetTEZWxHvqMmq8E687VJwI-uDpch7avo2nrAjb0bV6W_P2fP6-qm8zTYPN3fl5SZzCjFlViFIKKywAh2sljvtqSiMyT14bRUZWYAFUg7QrzRqn1vpFShcCtTOWTln5z_ebrA17bZdDLWJX9u_j_IbnxZVfQ
CitedBy_id crossref_primary_10_1088_2040_8986_aac68d
crossref_primary_10_1109_TIM_2023_3311052
crossref_primary_10_3390_photonics8050142
crossref_primary_10_3390_s17102414
crossref_primary_10_1016_j_sna_2024_115084
crossref_primary_10_1109_JSEN_2021_3055245
crossref_primary_10_1007_s11082_016_0494_1
crossref_primary_10_1109_JSEN_2020_2997465
crossref_primary_10_1109_TBME_2017_2722008
crossref_primary_10_1364_OL_400978
crossref_primary_10_1002_jbio_202400083
crossref_primary_10_1109_TBME_2018_2873754
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.1097/MBP.0000000000000079
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
Anatomy & Physiology
EISSN 1473-5725
ExternalDocumentID 25115621
Genre Research Support, Non-U.S. Gov't
Journal Article
GroupedDBID ---
.Z2
0R~
23N
4Q1
4Q2
4Q3
53G
5GY
5VS
6J9
6PF
8L-
AAAAV
AAHPQ
AAIQE
AAMTA
AARTV
AASCR
AAWTL
AAYEP
ABASU
ABBUW
ABDIG
ABJNI
ABOCM
ABVCZ
ABXVJ
ABZAD
ABZZY
ACDDN
ACEWG
ACGFO
ACGFS
ACILI
ACWDW
ACWRI
ACXJB
ACXNZ
ADFPA
ADGGA
ADHPY
ADNKB
AE3
AEETU
AENEX
AFBFQ
AFDTB
AHQNM
AHVBC
AINUH
AJCLO
AJIOK
AJNWD
AJNYG
AJZMW
AKCTQ
ALKUP
ALMA_UNASSIGNED_HOLDINGS
ALMTX
AMJPA
AMKUR
AMNEI
AOHHW
AOQMC
BQLVK
BS7
C45
CAG
CGR
COF
CS3
CUY
CVF
DIWNM
DU5
DUNZO
E.X
EBS
ECM
EEVPB
EIF
EJD
EX3
F5P
FCALG
FL-
GNXGY
GQDEL
H0~
HLJTE
HZ~
IKREB
IN~
IPNFZ
JF9
JG8
JK3
JK8
K8S
KD2
L-C
NPM
N~M
O9-
OAG
OAH
OCUKA
ODA
ONV
OPUJH
ORVUJ
OUVQU
OVD
OVDNE
OWU
OWV
OWW
OWX
OWY
OWZ
OXXIT
P-K
P2P
R58
RIG
RLZ
S4R
S4S
T8P
TEORI
TSPGW
V2I
VVN
W3M
WOQ
WOW
X3V
X3W
XXN
XYM
YFH
ZFV
ZZMQN
ID FETCH-LOGICAL-c377t-b371219b0b07c184d6fe99aa5f1f6b3ea291b1e3c17f8676f5b2f31374076ccb2
IngestDate Thu Apr 03 07:04:21 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 1
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c377t-b371219b0b07c184d6fe99aa5f1f6b3ea291b1e3c17f8676f5b2f31374076ccb2
PMID 25115621
ParticipantIDs pubmed_primary_25115621
PublicationCentury 2000
PublicationDate 2015-02-01
PublicationDateYYYYMMDD 2015-02-01
PublicationDate_xml – month: 02
  year: 2015
  text: 2015-02-01
  day: 01
PublicationDecade 2010
PublicationPlace England
PublicationPlace_xml – name: England
PublicationTitle Blood pressure monitoring
PublicationTitleAlternate Blood Press Monit
PublicationYear 2015
SSID ssj0016877
Score 2.1569216
Snippet Pulse waveform features related to cardiovascular pathologies and arterial stiffness have been extensively studied, and optical fiber sensors have been studied...
SourceID pubmed
SourceType Index Database
StartPage 43
SubjectTerms Adolescent
Adult
Blood Pressure - physiology
Carotid Arteries - physiology
Female
Fiber Optic Technology - instrumentation
Humans
Male
Pulse Wave Analysis - instrumentation
Vascular Stiffness - physiology
Young Adult
Title Central arterial pulse waveform acquisition with a portable pen-like optical fiber sensor
URI https://www.ncbi.nlm.nih.gov/pubmed/25115621
Volume 20
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3Li9QwGA-zCuJFdFddn-QgXkq0adokPY6iLMLIHnZhPS1JmkJxp61rR9E_w7_YL6_ZcWfFRw-lJBBKv1-_9wOhZxJgZBnPidSMEzfqntRVXRGVG5mXTVHoxvk7Fu_5wXH57qQ6mc1-bGQtrSb9wny_sq7kf6gKa0BXVyX7D5RdHwoL8Az0hTtQGO5_RePoms18XqZzfY8rkHTZV_XFOl00U-bTqgtJWbGILfPqtquWGm1PzrqPNhvGWMbockeyz2DWDue_hHpdanvm82VdsGHpmcB5kng-l6ebfLydBberf6ZTt2b4c5Br64kAq7PhYr2JgfqtrcOun0JMaIhHx_KI6KCgVcppdvIlMNVSMFKJUOCcuG6Rb6ErsNDQtWmLs4eOwYtXh6Hj5PoKo2g2iD0uPbWd6QS6Hf3z7qV-22lrB-2A5eFGqTr_T4xLcSlEKsCsxcurXse1l45HXDJVvMpydBvdirYGngfg3EEz2--ivXmvpmH5DT_HPvvXh1V20Y1FTLLYQx8irHCCFfawwglWeANW2MEKK5xghROscIQV9rDCAVZ30fHbN0evD0icwEEME2IimgkKIk3nOheGyrLhra1rpaqWtlwzq4qaamqZoaKVXPC20kXLKBNlLrgxuriHrvVDb_cRbowwkgmtalaWRuXSNqIuQBrUwBQYlw_Q_fCtTsfQZuU0fcWHv915hG5eAO4xut7Cf22fgJI46aeebj8B3wRivw
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Central+arterial+pulse+waveform+acquisition+with+a+portable+pen-like+optical+fiber+sensor&rft.jtitle=Blood+pressure+monitoring&rft.au=Leit%C3%A3o%2C+C%C3%A1tia&rft.au=Antunes%2C+Paulo&rft.au=Andr%C3%A9%2C+Paulo&rft.au=Pinto%2C+Jo%C3%A3o+L&rft.date=2015-02-01&rft.eissn=1473-5725&rft.volume=20&rft.issue=1&rft.spage=43&rft_id=info:doi/10.1097%2FMBP.0000000000000079&rft_id=info%3Apmid%2F25115621&rft_id=info%3Apmid%2F25115621&rft.externalDocID=25115621