An estimation model for the heating and cooling demand of a residential building with a different envelope design using the finite element method

•It is necessary to estimate heating and cooling demand by building envelope design.•The finite element method can be applied to estimate the heating and cooling demand.•Average error rate for heating and cooling demand was 4.95% and 5.77%, respectively.•Decision-makers can use the proposed model by...

Full description

Saved in:
Bibliographic Details
Published inApplied energy Vol. 115; pp. 205 - 215
Main Authors Koo, Choongwan, Park, Sungki, Hong, Taehoon, Park, Hyo Seon
Format Journal Article
LanguageEnglish
Published Kidlington Elsevier Ltd 15.02.2014
Elsevier
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:•It is necessary to estimate heating and cooling demand by building envelope design.•The finite element method can be applied to estimate the heating and cooling demand.•Average error rate for heating and cooling demand was 4.95% and 5.77%, respectively.•Decision-makers can use the proposed model by entering the simple information.•It can be applied to any other country or sector in a global environment. Building envelope design is considered one of the typical energy-saving techniques. Building envelope serves as the physical separator between building’s interior and exterior environment so as to maintain indoor thermal comfort. To achieve building sustainability, this research aims to develop an estimation model for the heating and cooling demand of a residential building with a different envelope design using the finite element method. This research was conducted in three steps: (i) selection of building envelope design elements affecting the heating and cooling demand of a multi-family housing unit; (ii) establishment of a standard database for the heating and cooling demand by building envelope design through energy simulation; and (iii) implementation of the finite element method for estimating the heating and cooling demand by building envelope design. The proposed model was validated compared to the simulation results and the actual data. Regarding the comparison with the simulation results, the average error rate for the heating and cooling demand was determined to be 1.09% and 6.61%, respectively. Also, regarding the comparison with the actual data, the average error rate for the heating and cooling consumption was determined to be 4.95% and 5.77%, respectively. The proposed model could allow an architect or a construction manager to easily and accurately estimate the heating and cooling demand of a residential building with a different envelope design in the early design phase. It could also be useful for contractors in a competitive bidding process to analyze the alternatives.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0306-2619
1872-9118
DOI:10.1016/j.apenergy.2013.11.014