Serum sFlt-1/PlGF ratio has better diagnostic ability in early- compared to late-onset pre-eclampsia

Background To establish gestational specific cutoffs for the soluble fms-like tyrosine kinase-1 (sFlt-1) and placental growth factor (PlGF) ratio as a diagnostic tool for pre-eclampsia (PE) in an Asian population. Methods 82 subjects (48 PE patients and 34 controls) were recruited. sFlt-1 and PlGF w...

Full description

Saved in:
Bibliographic Details
Published inJournal of perinatal medicine Vol. 47; no. 1; pp. 35 - 40
Main Authors Chuah, Theng Theng, Tey, Wan Shi, Ng, Mor Jack, Tan, Edward T.H., Chern, Bernard, Tan, Kok Hian
Format Journal Article
LanguageEnglish
Published Germany De Gruyter 01.01.2019
Walter de Gruyter GmbH
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background To establish gestational specific cutoffs for the soluble fms-like tyrosine kinase-1 (sFlt-1) and placental growth factor (PlGF) ratio as a diagnostic tool for pre-eclampsia (PE) in an Asian population. Methods 82 subjects (48 PE patients and 34 controls) were recruited. sFlt-1 and PlGF were analysed on the Roche Cobas e411 analyzer and their ratio was calculated. Diagnostic performance was evaluated using receiver-operating characteristics (ROC) curves. Optimal cutoffs for sFlt-1/PlGF ratio were determined for different gestation phases. Results The most optimal cut-off for the study group is 32 with a sensitivity and specificity of 85.1% and 100% and Youden Index (J) of 0.85. Applying this cutoff for early-onset PE (EO-PE), sensitivity increased to 95.8% while specificity remains at 100% (J=0.96). However, for late onset PE (LO-PE), sensitivity decreases to 73.9% while specificity remains at 100% (J=0.74). Two cutoffs were further determined for EO-PE and LO-PE - the first focusing on high sensitivity; the second focusing on high specificity. For EO-PE, cutoff <17 yielded sensitivity of 100% and specificity of 94.4% (J=0.94) while cutoff ≥32 yielded sensitivity of 95.8% and specificity of 100% (J=0.95). For LO-PE, cutoff <22 has a sensitivity of 82.6% and a specificity of 91.7% (J=0.74) while cutoff ≥32 yielded sensitivity of 73.9% and specificity of 100% (J=0.74). Conclusion While our study found an overall cutoff at 32 regardless of gestation age, it has limited diagnostic accuracy for LO-PE in our study. Multiple cutoffs focusing on either high sensitivity or high specificity enhance the performance of the sFlt-1/PlGF ratio as a diagnostic tool for PE and contribute to the identification of women at risk of PE in our Asian region.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0300-5577
1619-3997
DOI:10.1515/jpm-2017-0288