Deposits on hydrophilic 'bandage' lenses. A scanning electronmicroscopic and x-ray microanalytic study

Scanning electronmicroscopy of 34 continuously worn Sauflon PW 'bandage' lenses showed an initial deposition of cellular debris, followed by an increasing, general, non-penetrating, organic coating, particularly on the anterior lens surface. No microorganisms were found. X-ray microanalysi...

Full description

Saved in:
Bibliographic Details
Published inActa ophthalmologica Vol. 62; no. 6; p. 849
Main Authors Høvding, G, Seland, J H
Format Journal Article
LanguageEnglish
Published Denmark 01.12.1984
Subjects
Online AccessGet more information

Cover

Loading…
Abstract Scanning electronmicroscopy of 34 continuously worn Sauflon PW 'bandage' lenses showed an initial deposition of cellular debris, followed by an increasing, general, non-penetrating, organic coating, particularly on the anterior lens surface. No microorganisms were found. X-ray microanalysis of the 34 Sauflon PW lenses as well as 11 daily worn Hydroflex m lenses showed that elements may be added to or 'washed out' from the lenses during storage before preparation for microscopy. The elements obtained were constituents of both normal tear fluid and lens storage solutions. Only sulphur appeared firmly bound in the deposits, probably as sulphur-containing macromolecules of ocular mucus. Calcium was only detected in a few cases.
AbstractList Scanning electronmicroscopy of 34 continuously worn Sauflon PW 'bandage' lenses showed an initial deposition of cellular debris, followed by an increasing, general, non-penetrating, organic coating, particularly on the anterior lens surface. No microorganisms were found. X-ray microanalysis of the 34 Sauflon PW lenses as well as 11 daily worn Hydroflex m lenses showed that elements may be added to or 'washed out' from the lenses during storage before preparation for microscopy. The elements obtained were constituents of both normal tear fluid and lens storage solutions. Only sulphur appeared firmly bound in the deposits, probably as sulphur-containing macromolecules of ocular mucus. Calcium was only detected in a few cases.
Author Høvding, G
Seland, J H
Author_xml – sequence: 1
  givenname: G
  surname: Høvding
  fullname: Høvding, G
– sequence: 2
  givenname: J H
  surname: Seland
  fullname: Seland, J H
BackLink https://www.ncbi.nlm.nih.gov/pubmed/6524311$$D View this record in MEDLINE/PubMed
BookMark eNotj8tqwzAURLVISZO0n1AQ3WQl90qy_FiG9AmBblroLuhKcuJgS8ZyIP77mjazGTjMDMySzHzwjpBHDgmf9HRKeK4Uk3lWJLws0mRAKFKpksuMLACAs0yWP7dkGeMJQMoshzmZZ0qkkvMFqZ5dF2I9RBo8PY62D92xbmpD16i91Qe3po3z0cWEbmg02vvaH6hrnBn64Nva9CGa0E2FKU4vrNcj_aPa62YcJh6Hsx3vyE2lm-jur74i368vX9t3tvt8-9hudszIHBRTJaBWkOZY5MKAkIAorAGJaCuFFrSq0GWldWiVtLLQXBcVVymgQM6dWJGH_93ujK2z-66vW92P--tf8QtOrlwp
CitedBy_id crossref_primary_10_3109_02713688608995162
crossref_primary_10_1016_j_iac_2007_11_001
crossref_primary_10_1016_S0889_8561_05_70290_3
crossref_primary_10_1016_S0033_8389_22_00260_3
crossref_primary_10_1097_ACI_0b013e32830e6af0
crossref_primary_10_1016_S0161_6420_90_32596_4
crossref_primary_10_1016_S0141_7037_94_80013_8
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.1111/j.1755-3768.1984.tb08435.x
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
ExternalDocumentID 6524311
Genre Journal Article
GroupedDBID .55
.GJ
1OB
1OC
3O-
53G
5RE
8-1
ACBWZ
ACGFS
ACNCT
ACXQS
AFFNX
ALMA_UNASSIGNED_HOLDINGS
AZFZN
BDRZF
CGR
CUY
CVF
DUUFO
ECM
EIF
F5P
NPM
PALCI
SAMSI
WXSBR
X7M
ZGI
ZXP
ID FETCH-LOGICAL-c3705-590ba5047b872c0230bb2dc03bbdf5bd0a5fbe69debd53d38a1a8f1540b2b11e2
ISSN 0001-639X
IngestDate Thu May 23 23:50:47 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 6
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c3705-590ba5047b872c0230bb2dc03bbdf5bd0a5fbe69debd53d38a1a8f1540b2b11e2
PMID 6524311
ParticipantIDs pubmed_primary_6524311
PublicationCentury 1900
PublicationDate December 1984
PublicationDateYYYYMMDD 1984-12-01
PublicationDate_xml – month: 12
  year: 1984
  text: December 1984
PublicationDecade 1980
PublicationPlace Denmark
PublicationPlace_xml – name: Denmark
PublicationTitle Acta ophthalmologica
PublicationTitleAlternate Acta Ophthalmol (Copenh)
PublicationYear 1984
SSID ssj0033670
Score 1.3190969
Snippet Scanning electronmicroscopy of 34 continuously worn Sauflon PW 'bandage' lenses showed an initial deposition of cellular debris, followed by an increasing,...
SourceID pubmed
SourceType Index Database
StartPage 849
SubjectTerms Contact Lenses, Hydrophilic - adverse effects
Electron Probe Microanalysis
Humans
Microscopy, Electron, Scanning
Time Factors
Title Deposits on hydrophilic 'bandage' lenses. A scanning electronmicroscopic and x-ray microanalytic study
URI https://www.ncbi.nlm.nih.gov/pubmed/6524311
Volume 62
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LT9tAEF5BKxAXRAsISqn2UIlDZGR7vd7NMX0ghEQuBCk3NPsSB_IQRFXh13f24cSNgnhcVtGuY8f7fR7PTOZByHemCgAhdFaBxgFBz6ByPLPGdZ3MmTTBdXHZr8-vq4shHy5ll8zUqX5amVfyHlRxDnH1WbJvQHZ-UpzAz4gvjogwjq_C-JcNMVfB43_7aO4nU-8e0QinUN5D4Numiw6-Vx7QHEYR8KBjh6JO0_xm5MPxfGJKqtr6N7uHx06YBV-txFdzXRSgbYrV6hl08FKzW7gbJdk5Z4f_4_2H_GNSq5R5564r24RQXqR8CBNz72TVCttoxGeRoUozbIvPumzRpC0LZaxF-ryMFpx7-SZP_bW8i1qi7hajN1vgTUcBvZqXqOsULy4uVc9OK-tkXUgvAPvemRNf1MzXrovWUbyrVJO2CfRa_eu2yEY655IhEhSSwQ7ZTpYE7UVafCJrdvyZbF6mWIld4hp20MmYtthBTxI3TmhiBu3Rhhl0BTMoHk4DM-h_zKCBGXvk-uz34Od5lrpqZJqJnGe8myvgeSWUFKX2JqhSpdE5U8o4rkwO3Clbd41VhjPDJBQgHWrauSpVUdhyn3wYT8b2gFDGAZgTVuF2VAA1qrYOH36JXwUrBRyS_bhDN9NYOuUmbd2X5xaOyNaCeF_JR4dPqj1GtW-mvgXw_gHuMlW1
link.rule.ids 786
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Deposits+on+hydrophilic+%27bandage%27+lenses.+A+scanning+electronmicroscopic+and+x-ray+microanalytic+study&rft.jtitle=Acta+ophthalmologica&rft.au=H%C3%B8vding%2C+G&rft.au=Seland%2C+J+H&rft.date=1984-12-01&rft.issn=0001-639X&rft.volume=62&rft.issue=6&rft.spage=849&rft_id=info:doi/10.1111%2Fj.1755-3768.1984.tb08435.x&rft_id=info%3Apmid%2F6524311&rft_id=info%3Apmid%2F6524311&rft.externalDocID=6524311
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0001-639X&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0001-639X&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0001-639X&client=summon