Effect of Nonionic Iodinated Contrast Media on Blood Pressure during Contrast-enhanced Computed Tomography of Abdomen Examination: A Cross-sectional Study
ABSTRACT Introduction: Computed tomography (CT) scan has high sensitivity and specificity for numerous conditions. The images produced by a CT scanner can be enhanced using iodinated contrast media. Significant hemodynamic changes are seen with rapid intravenous contrast media injection. The average...
Saved in:
Published in | Asian journal of pharmaceutical research and health care Vol. 16; no. 2; pp. 203 - 207 |
---|---|
Main Authors | , |
Format | Journal Article |
Language | English |
Published |
India
Wolters Kluwer - Medknow
01.04.2024
|
Edition | 2 |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | ABSTRACT
Introduction:
Computed tomography (CT) scan has high sensitivity and specificity for numerous conditions. The images produced by a CT scanner can be enhanced using iodinated contrast media. Significant hemodynamic changes are seen with rapid intravenous contrast media injection. The average acceptable blood pressure (BP) value is 120/80 mmHg. Many studies have related hypertensive crises with high-osmolar contrast media, whereas its relation with low-osmolar contrast media is still unclear. This study aims to evaluate the effect of nonionic iodinated contrast media on BP during contrast-enhanced CT (CECT) of the abdomen.
Materials and Methods:
A cross-sectional study was conducted from April 2022 to August 2023. A total of 146 subjects (73 males and 73 females were included in the study). Statistical analysis of data was done using SPSS 23.0. A comparison of systolic BP and diastolic BP across the three periods was done using repeated measures of ANOVA. A between-group comparison was performed by unpaired t-test. The level of significance was set as 5%. All subjects underwent a CECT abdomen, including a plain, arterial, and venous phase. A bolus of 80 mL of Ultravist was administered. BP was measured before the contrast injection (baseline value), between the arterial and venous phases, and 3 min after the contrast injection.
Results:
Injection of nonionic contrast media caused a decrease in BP among subjects. The mean systolic BP readings before contrast injection in males and females were 127.5 ± 8 mmHg and 122.8 ± 8.4 mmHg, respectively. The mean diastolic BP before contrast injection was 79.2 ± 6.4 and 76 ± 6.4 mmHg among males and females, respectively. For systolic, these values decreased to 123 ± 10.3 mmHg in males and in females to 115 ± 14.6 mmHg when measured between arterial and venous phases. Similarly, for diastolic BP, the mean values recorded between the arterial-venous phase reduced to 76.7 ± 9.3 mmHg and 72.3 ± 10 mmHg, respectively. The BP readings, however, increased near baseline value when measured 3 min after the injection. The mean systolic BP measured 126.1 ± 8.5 mmHg and 124.9 ± 11.8 mmHg for males and females at 3 min after injection. Similarly, the mean diastolic BP values taken after 3 min of contrast injection were 78.3 ± 6.5 mmHg and 76.2 ± 7 mmHg in males and females, respectively, P < 0.001. BP in both male and female groups was affected similarly.
Conclusion:
Bolus administration of 80 mL of Ultravist reduced BP. This reduction was short-term and got back to normal within a few minutes. The contrast media similarly affected both genders. The BP changes had no clinical significance. |
---|---|
AbstractList | ABSTRACT
Introduction:
Computed tomography (CT) scan has high sensitivity and specificity for numerous conditions. The images produced by a CT scanner can be enhanced using iodinated contrast media. Significant hemodynamic changes are seen with rapid intravenous contrast media injection. The average acceptable blood pressure (BP) value is 120/80 mmHg. Many studies have related hypertensive crises with high-osmolar contrast media, whereas its relation with low-osmolar contrast media is still unclear. This study aims to evaluate the effect of nonionic iodinated contrast media on BP during contrast-enhanced CT (CECT) of the abdomen.
Materials and Methods:
A cross-sectional study was conducted from April 2022 to August 2023. A total of 146 subjects (73 males and 73 females were included in the study). Statistical analysis of data was done using SPSS 23.0. A comparison of systolic BP and diastolic BP across the three periods was done using repeated measures of ANOVA. A between-group comparison was performed by unpaired t-test. The level of significance was set as 5%. All subjects underwent a CECT abdomen, including a plain, arterial, and venous phase. A bolus of 80 mL of Ultravist was administered. BP was measured before the contrast injection (baseline value), between the arterial and venous phases, and 3 min after the contrast injection.
Results:
Injection of nonionic contrast media caused a decrease in BP among subjects. The mean systolic BP readings before contrast injection in males and females were 127.5 ± 8 mmHg and 122.8 ± 8.4 mmHg, respectively. The mean diastolic BP before contrast injection was 79.2 ± 6.4 and 76 ± 6.4 mmHg among males and females, respectively. For systolic, these values decreased to 123 ± 10.3 mmHg in males and in females to 115 ± 14.6 mmHg when measured between arterial and venous phases. Similarly, for diastolic BP, the mean values recorded between the arterial-venous phase reduced to 76.7 ± 9.3 mmHg and 72.3 ± 10 mmHg, respectively. The BP readings, however, increased near baseline value when measured 3 min after the injection. The mean systolic BP measured 126.1 ± 8.5 mmHg and 124.9 ± 11.8 mmHg for males and females at 3 min after injection. Similarly, the mean diastolic BP values taken after 3 min of contrast injection were 78.3 ± 6.5 mmHg and 76.2 ± 7 mmHg in males and females, respectively, P < 0.001. BP in both male and female groups was affected similarly.
Conclusion:
Bolus administration of 80 mL of Ultravist reduced BP. This reduction was short-term and got back to normal within a few minutes. The contrast media similarly affected both genders. The BP changes had no clinical significance. |
Author | Jaseemudheen, M. M. Betkar, Dakshata Dattaram |
Author_xml | – sequence: 1 givenname: Dakshata Dattaram surname: Betkar fullname: Betkar, Dakshata Dattaram – sequence: 2 givenname: M. M. surname: Jaseemudheen fullname: Jaseemudheen, M. M. email: jaseemudheen12@gmail.com |
BookMark | eNp9kN1OwjAUxxuDiYg8gTd9gWHblX14hwSVBMVEvG66fsBga5d2C_IqPq2bIPHKpMlpTs7v_E9-16BnrFEA3GI0ohiFd3xbuY0YHQvDhBF6AfqEjFGAaYR65z-lV2Do_RYh1HJhisd98DXTWokaWg1frcnbJ-DcytzwWkk4taZ23NfwRcmcQ2vgQ2GthG9Oed84BWXjcrM-zwXKbLgRP2RZNd2KlS3t2vFqc-gyJpm0pTJw9snLLqMNvIcTOHXW-8C3h7QNXsD3upGHG3CpeeHV8FQH4ONxtpo-B4vl03w6WQQijFIRJKmIVRJqjLmMaarGhCOdpVoSlKIsjjIaEYniJMo0TpNQaCzSRBJN8ZggSnU4AOFxr-iucEqzyuUldweGEesMs5Pav4Zbanmk9raolfO7otkrx0old8bu_0MZaftH7cxq9qs9_AadoJRP |
Cites_doi | 10.1186/s13054-020-02859-w 10.1213/ANE.0000000000002346 10.2214/ajr.157.6.1950858 10.1097/00004424-198904000-00007 10.1016/S0140-6736(16)31919-5 10.1016/j.radi.2019.04.008 10.1097/00004424-198711000-00011 10.1097/RTI.0b013e3181efe8b0 10.1148/117.2.257 10.1007/s11604-011-0573-y 10.1016/S0720-048X(98)00018-7 10.2214/ajr.107.4.869 10.1097/RLI.0000000000000696 |
ContentType | Journal Article |
Copyright | Copyright: © 2024 Asian Journal of Pharmaceutical Research and Health Care |
Copyright_xml | – notice: Copyright: © 2024 Asian Journal of Pharmaceutical Research and Health Care |
DBID | AAYXX CITATION |
DOI | 10.4103/ajprhc.ajprhc_12_24 |
DatabaseName | CrossRef |
DatabaseTitle | CrossRef |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Pharmacy, Therapeutics, & Pharmacology |
EISSN | 2250-1460 |
Edition | 2 |
EndPage | 207 |
ExternalDocumentID | 10_4103_ajprhc_ajprhc_12_24 AJPRH-16-203 |
GroupedDBID | --- 5VS AAKDD ALMA_UNASSIGNED_HOLDINGS H13 IAO IHR INH ITC KQ8 OK1 OVD RMW TEORI W3E AAYXX ADJBI CITATION |
ID | FETCH-LOGICAL-c369c-89c7e83f11ad749e52a0fb9fd2090b76b462d0786bf1983cf1c98d2f4152044f3 |
IEDL.DBID | W3E |
ISSN | 2250-1444 |
IngestDate | Tue Jul 01 01:33:42 EDT 2025 Wed May 28 23:12:26 EDT 2025 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 2 |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c369c-89c7e83f11ad749e52a0fb9fd2090b76b462d0786bf1983cf1c98d2f4152044f3 |
OpenAccessLink | https://doi.org/10.4103/ajprhc.ajprhc_12_24 |
PageCount | 5 |
ParticipantIDs | crossref_primary_10_4103_ajprhc_ajprhc_12_24 wolterskluwer_medknow_10_4103_ajprhc_ajprhc_12_24_203_Effect_of_Nonionic |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2024-04-01 |
PublicationDateYYYYMMDD | 2024-04-01 |
PublicationDate_xml | – month: 04 year: 2024 text: 2024-04-01 day: 01 |
PublicationDecade | 2020 |
PublicationPlace | India |
PublicationPlace_xml | – name: India |
PublicationTitle | Asian journal of pharmaceutical research and health care |
PublicationYear | 2024 |
Publisher | Wolters Kluwer - Medknow |
Publisher_xml | – name: Wolters Kluwer - Medknow |
References | Morris (R17-20240901) 1989; 24 Morcos (R12-20240901) 1998; 29 (R15-20240901) 1995 Ramos-Duran (R13-20240901) 2010; 25 Alfidi (R4-20240901) 1975; 117 Harnish (R9-20240901) 1987; 22 (R3-20240901) 2017; 389 John (R8-20240901) 2019; 25 Saugel (R2-20240901) 2020; 24 Delius (R18-20240901) 1969; 107 Bush (R7-20240901) 1991; 157 Nakano (R10-20240901) 2011; 29 Schöckel (R5-20240901) 2020; 55 Widmann (R16-20240901) 2018; 126 |
References_xml | – volume: 24 start-page: 172 year: 2020 ident: R2-20240901 article-title: How to measure blood pressure using an arterial catheter: A systematic 5-step approach publication-title: Crit Care doi: 10.1186/s13054-020-02859-w – volume: 126 start-page: 769 year: 2018 ident: R16-20240901 article-title: Systemic hypotension following intravenous administration of nonionic contrast medium during computed tomography: Iopromide versus iodixanol publication-title: Anesth Analg doi: 10.1213/ANE.0000000000002346 – year: 1995 ident: R15-20240901 publication-title: ULTRAVIST (Iopromide) Injection, for Intravenous or Intra-Arterial Use Initial U. S. Approval – volume: 157 start-page: 1153 year: 1991 ident: R7-20240901 article-title: Acute reactions to intravascular contrast media: Types, risk factors, recognition, and specific treatment publication-title: AJR Am J Roentgenol doi: 10.2214/ajr.157.6.1950858 – volume: 24 start-page: 294 year: 1989 ident: R17-20240901 article-title: A comparison of the systemic responses to rapid intravenous injections of ioxilan, iohexol, and diatrizoate in rabbits publication-title: Invest Radiol doi: 10.1097/00004424-198904000-00007 – volume: 389 start-page: 37 year: 2017 ident: R3-20240901 publication-title: Lancet doi: 10.1016/S0140-6736(16)31919-5 – volume: 25 start-page: 346 year: 2019 ident: R8-20240901 article-title: Effect of bolus administration of non-ionic radiopaque contrast media on blood pressure variation publication-title: Radiography (Lond) doi: 10.1016/j.radi.2019.04.008 – volume: 22 start-page: 901 year: 1987 ident: R9-20240901 article-title: Physiologic effects of contrast media in the rabbit publication-title: Invest Radiol doi: 10.1097/00004424-198711000-00011 – volume: 25 start-page: 270 year: 2010 ident: R13-20240901 article-title: Current contrast media delivery strategies for cardiac and pulmonary multidetector-row computed tomography angiography publication-title: J Thorac Imaging doi: 10.1097/RTI.0b013e3181efe8b0 – volume: 117 start-page: 257 year: 1975 ident: R4-20240901 article-title: Computed tomography of the thorax and abdomen;a preliminary report publication-title: Radiology doi: 10.1148/117.2.257 – volume: 29 start-page: 449 year: 2011 ident: R10-20240901 article-title: Hypertensive crisis due to contrast-enhanced computed tomography in a patient with malignant pheochromocytoma publication-title: Jpn J Radiol doi: 10.1007/s11604-011-0573-y – volume: 29 start-page: 31 year: 1998 ident: R12-20240901 article-title: The haemodynamic effects of iodinated water soluble radiographic contrast media: A review publication-title: Eur J Radiol doi: 10.1016/S0720-048X(98)00018-7 – volume: 107 start-page: 869 year: 1969 ident: R18-20240901 article-title: Effect of contrast medium on blood flow and blood pressure in lower extremities publication-title: Am J Roentgenol Radium Ther Nucl Med doi: 10.2214/ajr.107.4.869 – volume: 55 start-page: 592 year: 2020 ident: R5-20240901 article-title: Developments in X-ray contrast media and the potential impact on computed tomography publication-title: Invest Radiol doi: 10.1097/RLI.0000000000000696 |
SSID | ssj0001033915 |
Score | 2.256353 |
Snippet | ABSTRACT
Introduction:
Computed tomography (CT) scan has high sensitivity and specificity for numerous conditions. The images produced by a CT scanner can be... |
SourceID | crossref wolterskluwer |
SourceType | Index Database Publisher |
StartPage | 203 |
SubjectTerms | Original Article |
Title | Effect of Nonionic Iodinated Contrast Media on Blood Pressure during Contrast-enhanced Computed Tomography of Abdomen Examination: A Cross-sectional Study |
URI | https://doi.org/10.4103/ajprhc.ajprhc_12_24 |
Volume | 16 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV3LTtwwFLVauqlUVfSlUh66C8Rq3MaPODG7AYGmLBCLQWVn-RELtSJBM4NgfoWvxTcOZVjQVVeRosSRdWzd49xzzyVktyi9jKUtKXZ2obLkluoiOmpd9MqqKm2vXuV7qibn8uSivBh8trEWZiV_L1khftjf17NL_z1fDOOGy9fkDa94ifqtX2Llh0oh0Owcm8mlsE7TQUFml6GXxnkWid7ddpidnv_pxekrIeZ4nbwfuCGMM5gfyKum_Uj2zrK59HIE06daqfkI9uDsyXZ6-YncZyNi6CKcpo2Klrfws0uhKbHJAOhCNbPzBWBmxkLXwgFK1iGXB84ayPWKf5-jTXvZiwNg6PsQYNpdDf7W-I2xC2jeAEd3FtU0iO8-jOEQ50rnvcALJ4M6xeVncn58ND2c0KHzAvVCaU9r7aumFpExGyqpmwRhAlDHwAtduEo5qXhI5EK5yHQtfGRe14FHZAOFlFF8IWtt1zZfCZRChkapmskQpCu0C0JHHZysg2eOsQ0yekTBXGeDDZMOJgiaGdBaBW2DTJ4hZa5y1eC_3jE83c8YmC6aRwy-_b-hNslbnshOVvRskbXF7KbZTmRl4Xb6RfoACqvwaQ |
linkProvider | Wolters Kluwer Health |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Effect+of+Nonionic+Iodinated+Contrast+Media+on+Blood+Pressure+during+Contrast-enhanced+Computed+Tomography+of+Abdomen+Examination%3A+A+Cross-sectional+Study&rft.jtitle=Asian+journal+of+pharmaceutical+research+and+health+care&rft.au=Betkar%2C+Dakshata+Dattaram&rft.au=Jaseemudheen%2C+M.+M.&rft.date=2024-04-01&rft.issn=2250-1444&rft.eissn=2250-1460&rft.volume=16&rft.issue=2&rft.spage=203&rft.epage=207&rft_id=info:doi/10.4103%2Fajprhc.ajprhc_12_24&rft.externalDBID=n%2Fa&rft.externalDocID=10_4103_ajprhc_ajprhc_12_24 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2250-1444&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2250-1444&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2250-1444&client=summon |