Quantitative analysis of repaired rabbit supraspinatus tendons (± channeling) using magnetic resonance imaging at 7 Tesla

BACKGROUNDThe quantitative assessment of supraspinatus tendons by conventional magnetic resonance is limited by low contrast-to-noise ratio (CNR). Magnetic resonance imaging (MRI) scanners operating at 7 Tesla offer high signal-to noise ratio (SNR), low CNR and high spatial resolution that are well-...

Full description

Saved in:
Bibliographic Details
Published inQuantitative imaging in medicine and surgery Vol. 11; no. 8; pp. 3460 - 3471
Main Authors Trudel, Guy, Duchesne-Bélanger, Samuel, Thomas, Justin, Melkus, Gerd, Cron, Greg O., Larson, Peder E. Z., Schweitzer, Mark, Sheikh, Adnan, Louati, Hakim, Laneuville, Odette
Format Journal Article
LanguageEnglish
Published AME Publishing Company 01.08.2021
Subjects
Online AccessGet full text

Cover

Loading…
Abstract BACKGROUNDThe quantitative assessment of supraspinatus tendons by conventional magnetic resonance is limited by low contrast-to-noise ratio (CNR). Magnetic resonance imaging (MRI) scanners operating at 7 Tesla offer high signal-to noise ratio (SNR), low CNR and high spatial resolution that are well-suited for rapidly relaxing tissues like tendons. Few studies have applied T2 and T2* mapping to musculoskeletal imaging and to the rotator cuff tendons. Our objective was to analyze the T2 and T2* relaxation times from surgically repaired supraspinatus tendons and the effect of bone channeling. METHODSOne supraspinatus tendon of 112 adult female New Zealand white rabbits was surgically detached and repaired one week later. Rabbits were randomly assigned to channeling (n=64) or control (n=48) groups and harvested at 0, 1, 2, and 4 weeks. A 7T magnet was used for signal acquisition. For T2 mapping, a sagittal multi slice 2D multi-echo spin-echo (MESE) CPMG sequence with fat saturation was applied and T2* mapping was performed using a 3D UTE sequence. Magnetic resonance images from supraspinatus tendons were analyzed by two raters. Three regions of interest were manually drawn on the first T2-weighted dataset. For T2 and T2*, different ROI masks were generated to obtain relaxation times. RESULTST2-weighted maps but not T2*-weighted maps generated reliable signals for relaxation time measurement. Torn supraspinatus tendons had lower T2 than controls at the time of repair (20.0±3.4 vs. 25.6±3.9 ms; P<0.05). T2 increased at 1, 2 and 4 postoperative weeks: 22.7±3.1, 23.3±3.9 and 24.0±5.1 ms, respectively, and values were significantly different from contralateral supraspinatus tendons (24.8±3.1; 26.8±4.3 and 26.5±3.6 ms; all P<0.05). Bone channeling did not affect T2 (P>0.05). CONCLUSIONSSupraspinatus tendons detached for 1 week had shorter T2 relaxation time compared to contralateral as measured with 7T MRI.
AbstractList BACKGROUNDThe quantitative assessment of supraspinatus tendons by conventional magnetic resonance is limited by low contrast-to-noise ratio (CNR). Magnetic resonance imaging (MRI) scanners operating at 7 Tesla offer high signal-to noise ratio (SNR), low CNR and high spatial resolution that are well-suited for rapidly relaxing tissues like tendons. Few studies have applied T2 and T2* mapping to musculoskeletal imaging and to the rotator cuff tendons. Our objective was to analyze the T2 and T2* relaxation times from surgically repaired supraspinatus tendons and the effect of bone channeling. METHODSOne supraspinatus tendon of 112 adult female New Zealand white rabbits was surgically detached and repaired one week later. Rabbits were randomly assigned to channeling (n=64) or control (n=48) groups and harvested at 0, 1, 2, and 4 weeks. A 7T magnet was used for signal acquisition. For T2 mapping, a sagittal multi slice 2D multi-echo spin-echo (MESE) CPMG sequence with fat saturation was applied and T2* mapping was performed using a 3D UTE sequence. Magnetic resonance images from supraspinatus tendons were analyzed by two raters. Three regions of interest were manually drawn on the first T2-weighted dataset. For T2 and T2*, different ROI masks were generated to obtain relaxation times. RESULTST2-weighted maps but not T2*-weighted maps generated reliable signals for relaxation time measurement. Torn supraspinatus tendons had lower T2 than controls at the time of repair (20.0±3.4 vs. 25.6±3.9 ms; P<0.05). T2 increased at 1, 2 and 4 postoperative weeks: 22.7±3.1, 23.3±3.9 and 24.0±5.1 ms, respectively, and values were significantly different from contralateral supraspinatus tendons (24.8±3.1; 26.8±4.3 and 26.5±3.6 ms; all P<0.05). Bone channeling did not affect T2 (P>0.05). CONCLUSIONSSupraspinatus tendons detached for 1 week had shorter T2 relaxation time compared to contralateral as measured with 7T MRI.
Author Trudel, Guy
Melkus, Gerd
Duchesne-Bélanger, Samuel
Thomas, Justin
Cron, Greg O.
Larson, Peder E. Z.
Laneuville, Odette
Sheikh, Adnan
Louati, Hakim
Schweitzer, Mark
Author_xml – sequence: 1
  givenname: Guy
  surname: Trudel
  fullname: Trudel, Guy
– sequence: 2
  givenname: Samuel
  surname: Duchesne-Bélanger
  fullname: Duchesne-Bélanger, Samuel
– sequence: 3
  givenname: Justin
  surname: Thomas
  fullname: Thomas, Justin
– sequence: 4
  givenname: Gerd
  surname: Melkus
  fullname: Melkus, Gerd
– sequence: 5
  givenname: Greg O.
  surname: Cron
  fullname: Cron, Greg O.
– sequence: 6
  givenname: Peder E. Z.
  surname: Larson
  fullname: Larson, Peder E. Z.
– sequence: 7
  givenname: Mark
  surname: Schweitzer
  fullname: Schweitzer, Mark
– sequence: 8
  givenname: Adnan
  surname: Sheikh
  fullname: Sheikh, Adnan
– sequence: 9
  givenname: Hakim
  surname: Louati
  fullname: Louati, Hakim
– sequence: 10
  givenname: Odette
  surname: Laneuville
  fullname: Laneuville, Odette
BookMark eNpVkctqHTEMhk1JadKTLLv3Ml1M68vM-HhTKKE3CIRAsjYaj-bEZY49sTyB9K36Cn2y-jRpodpI6BefhP7X7CimiIy9keKdkkKb9_dhT40SjdStfsFOlFK6abXoj_7Wyqpjdkb0XdQwW2mkeMWO63QrjdIn7Mf1CrGEAiU8IIcI8yMF4mniGRcIGUeeYRhC4bQuGWgJEcpKvGAcUyR-_usn93cQI84h7t7ylWrie9hFLMFXCKUI0SMPtXeQoHDDb5BmOGUvJ5gJz57zht1-_nRz8bW5vPry7eLjZeN135ZGDbYbxWgHO2BvvJVKSt3bTopeidFLGDvbT3YEg5Nt1SCtMcPWWxitbycFesM-PHGXddjj6DGWDLNbcj0pP7oEwf2vxHDndunBbVVb0X0FnD8DcrpfkYrbB_I4zxAxreRU15lOb3V96IY1T6M-J6KM0781Urg_lrmDZU4Jd7BM_wYLfo4i
CitedBy_id crossref_primary_10_1155_2022_1544440
ContentType Journal Article
Copyright 2021 Quantitative Imaging in Medicine and Surgery. All rights reserved. 2021 Quantitative Imaging in Medicine and Surgery.
Copyright_xml – notice: 2021 Quantitative Imaging in Medicine and Surgery. All rights reserved. 2021 Quantitative Imaging in Medicine and Surgery.
DBID AAYXX
CITATION
7X8
5PM
DOI 10.21037/qims-20-1343
DatabaseName CrossRef
MEDLINE - Academic
PubMed Central (Full Participant titles)
DatabaseTitle CrossRef
MEDLINE - Academic
DatabaseTitleList MEDLINE - Academic
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 2223-4306
EndPage 3471
ExternalDocumentID 10_21037_qims_20_1343
GroupedDBID 53G
AAKDD
AAYXX
ALMA_UNASSIGNED_HOLDINGS
CITATION
DIK
HYE
M~E
OK1
RPM
7X8
5PM
ID FETCH-LOGICAL-c364t-2b95d0d9b9be67c91211369510620dc1ad596f9da7ef942b1977b8c9ad9c4f2a3
IEDL.DBID RPM
ISSN 2223-4292
IngestDate Fri Sep 01 02:23:42 EDT 2023
Fri Aug 16 04:55:03 EDT 2024
Fri Aug 23 02:11:30 EDT 2024
IsDoiOpenAccess false
IsOpenAccess true
IsPeerReviewed false
IsScholarly true
Issue 8
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c364t-2b95d0d9b9be67c91211369510620dc1ad596f9da7ef942b1977b8c9ad9c4f2a3
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Contributions: (I) Conception and design: G Trudel, PEZ Larson, M Schweitzer, O Laneuville; (II) Administrative support: G Trudel, O Laneuville; (III) Provision of study materials or patients: G Trudel, O Laneuville; (IV) Collection and assembly of data: G Trudel, S Duchesne-Bélanger, J Thomas, G Melkus, GO Cron, A Sheikh, O Laneuville; (V) Data analysis and interpretation: G Trudel, S Duchesne-Bélanger, G Melkus, GO Cron, A Sheikh, O Laneuville; (VI) Manuscript writing: All authors; (VII) Final approval of manuscript: All authors.
OpenAccessLink https://qims.amegroups.com/article/viewFile/70535/pdf
PMID 34341723
PQID 2557538372
PQPubID 23479
PageCount 12
ParticipantIDs pubmedcentral_primary_oai_pubmedcentral_nih_gov_8245966
proquest_miscellaneous_2557538372
crossref_primary_10_21037_qims_20_1343
PublicationCentury 2000
PublicationDate 2021-8-00
20210801
PublicationDateYYYYMMDD 2021-08-01
PublicationDate_xml – month: 08
  year: 2021
  text: 2021-8-00
PublicationDecade 2020
PublicationTitle Quantitative imaging in medicine and surgery
PublicationYear 2021
Publisher AME Publishing Company
Publisher_xml – name: AME Publishing Company
SSID ssj0000781710
Score 2.2085536
Snippet BACKGROUNDThe quantitative assessment of supraspinatus tendons by conventional magnetic resonance is limited by low contrast-to-noise ratio (CNR). Magnetic...
SourceID pubmedcentral
proquest
crossref
SourceType Open Access Repository
Aggregation Database
StartPage 3460
SubjectTerms Original
Title Quantitative analysis of repaired rabbit supraspinatus tendons (± channeling) using magnetic resonance imaging at 7 Tesla
URI https://search.proquest.com/docview/2557538372
https://pubmed.ncbi.nlm.nih.gov/PMC8245966
Volume 11
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3LatwwFBWTWZRuQh8pmfSBCiWkC2VsSbasZQkNoTClgQSyM3o5McSayYxnk7_KL_TLeq_G02a23XhjWxjdg-6Rde65hHwJ3miRi4JlgnsmCyVYJYRjSgcntWhK45Pa4md5cS1_3BQ3I1Jsa2GSaN_Z9jTed6exvUvaykXnplud2PTX7KzisgCaPt0jewDQZ1v0tPyqKlfJhQBTH8N2TBtvTZ7MfB7abgXQYLmQ2EMHrhJyuNhNS_-45q5S8lnqOX9F9gfOSL9tvu01GYX4hryYDafib8nj5drEVCwGSxc1g80InTd0CckG1jRPl8batqer9WJpVosW7TxXFH9_A-joye8nigXAMdWmf6Wohb-lnbmNWOEIgyBdB3DQtks9jajpqaJXAdB0QK7Pv1-dXbChpwJzopQ941YXPvPaahtK5TQ6vIkSaVbJM-9y42FmG-2NCo2W3ObAD23ltPHayYYb8Y6M4zyGQ0KrhlteOVvqoGQwGF1TuQwIoQ5VpsKEHG-ntF5srDNq2HKkMNQYhprjaZoUE_J5O-E1gBtPLEwM8zU8UACbxD00nxC1E4m_I6I99u4dQE2yyR5QcvTfb74nLzkqWJLc7wMZ98t1-AgUpLefEuT-ACkL34U
link.rule.ids 230,315,730,783,787,888,27937,27938,53805,53807
linkProvider National Library of Medicine
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Nb9QwELVKkYAL5atioYCREIKDdxPbieMjqlot0K1A2qLeIn-lRBDvsptc-q_4C_wyxt6EdrnBJRcnVqIZe97Eb94g9MpZJVnKMpIwagnPBCMFY4YI6QyXrMqVjWyL03x6xj-cZ-c7KBtqYSJp3-h67L83Y19_jdzKZWMmA09s8ml2WFCeAUyf3EA3Yb0m2bUkPW7AokhF1CEIwY-EhkwbdU0a5Xx-1M0anIOkjIcuOnDlEMXZdmC6QpvbXMlrwed4D30ZXnvDOfk27lo9Npd_KTr-83fdQ3d7OIrfbYbvox3nH6Bbs_7A_SG6_NwpH-vQYFfEqlcwwYsKryCOwXZp8UppXbd43S1Xar2sg1LoGoc_6-DP-M2vnzjUFvtY9v4WB5r9BW7UhQ_FkzBJyATA73DdxHZJWLVY4LkDR32Ezo6P5odT0rdrIIblvCVUy8wmVmqpXS6MDOJxLA8ILqeJNamy8HGVtEq4SnKqU4CeujBSWWl4RRXbR7t-4d1jhIuKaloYnUsnuFPBcVRhEsCa0hWJcCP0erBVudyocpSQzUT7lsG-JQ0HdZyN0MvBkiWsm3AYorxbdHBDBkA1pOd0hMSWif_MGJS3t0fAcFGBuzfUk_9-8gW6PZ3PTsqT96cfn6I7NBBlIqvwAO22q849A6TT6ufRr38DqSQBkw
linkToPdf http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9QwELagSBUX3qhbXkZCCA7e3dhOHB9RYVUerYrUShWXyK-UCJJNd5NL_xV_gV_GjDcLuxx7ySWOFeubeGbib74h5FXwRotEpGwquGcyVYLlQjimdHBSizIzPrItjrPDM_npPD3faPUVSfvOVuPmZz1uqu-RW9nWbrLmiU1Ojg5yLlMI0yetLyc3ya0URdM3EvW4Cas8UVGLAB0gw6ZMK4VNHiV9Lqt6CQbCEiGxkw5cJXhyse2c_kWc23zJDQc0u0u-rV99xTv5Me47O3ZX_6k6Xmtt98idISyl71ZD7pMboXlAdo-Gg_eH5Oprb5pYjwa7IzWDkgmdl3QB_gy2TU8Xxtqqo8u-XZhlW6Fi6JLiH3awa_rm9y-KNcZNLH9_S5Fuf0Frc9FgESVMghkB2B-t6tg2iZqOKnoawGAfkbPZh9ODQza0bWBOZLJj3OrUT7222oZMOY0iciLDSC7jU-8S42GBpfZGhVJLbhMIQW3utPHayZIb8ZjsNPMm7BGal9zy3NlMByWDQQMyuZtCzKkDYB5G5PUar6JdqXMUkNVEjAvEuOB4YCfFiLxco1nA94OHIqYJ8x4GpBCwYprOR0Rtwfx3RlTg3r4D4EUl7gGs_Ws_-YLsnryfFV8-Hn9-Qm5z5MtEcuFTstMt-vAMAp7OPo-m_Qef6gQT
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Quantitative+analysis+of+repaired+rabbit+supraspinatus+tendons+%28%C2%B1+channeling%29+using+magnetic+resonance+imaging+at+7+Tesla&rft.jtitle=Quantitative+imaging+in+medicine+and+surgery&rft.au=Trudel%2C+Guy&rft.au=Duchesne-B%C3%A9langer%2C+Samuel&rft.au=Thomas%2C+Justin&rft.au=Melkus%2C+Gerd&rft.date=2021-08-01&rft.pub=AME+Publishing+Company&rft.issn=2223-4292&rft.eissn=2223-4306&rft.volume=11&rft.issue=8&rft.spage=3460&rft.epage=3471&rft_id=info:doi/10.21037%2Fqims-20-1343&rft_id=info%3Apmid%2F34341723&rft.externalDBID=PMC8245966
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2223-4292&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2223-4292&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2223-4292&client=summon