Beam test of a one-dimensional position sensitive chamber on synchrotron radiation
A one-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of Beijing Synchrotron Radiation Source. The data of the beam te...
Saved in:
Published in | Chinese physics C Vol. 37; no. 10; pp. 105 - 109 |
---|---|
Main Author | |
Format | Journal Article |
Language | English |
Published |
01.10.2013
|
Subjects | |
Online Access | Get full text |
ISSN | 1674-1137 0254-3052 |
DOI | 10.1088/1674-1137/37/10/108001 |
Cover
Loading…
Abstract | A one-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of Beijing Synchrotron Radiation Source. The data of the beam test were analyzed and some diffraction angles were obtained. The experimental results were in good agreement with standard data from ICDD powder diffraction file. The precision of diffraction angles was 1% to 4.7%. Most of the relative errors between measured values of diffraction angles and existing data were less than 1%. As for the detector, the best position resolution in the test was 138 p.m (a value) with an X-ray tube. Finally, discussions of the results were given. The major factor that affected the precision of measurement was deviation from the flat structure of the detector. The effect was analyzed and the conclusion was reached that it would be the optimal measurement scheme when the distance between the powder sample and detector was from 400 mm to 600 mm. |
---|---|
AbstractList | A one-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO sub(2) has been accomplished at 1W2B laboratory of Beijing Synchrotron Radiation Source. The data of the beam test were analyzed and some diffraction angles were obtained. The experimental results were in good agreement with standard data from ICDD powder diffraction file. The precision of diffraction angles was 1% to 4.7%. Most of the relative errors between measured values of diffraction angles and existing data were less than 1%. As for the detector, the best position resolution in the test was 138 mu m ([sigma] value) with an X-ray tube. Finally, discussions of the results were given. The major factor that affected the precision of measurement was deviation from the flat structure of the detector. The effect was analyzed and the conclusion was reached that it would be the optimal measurement scheme when the distance between the powder sample and detector was from 400 mm to 600 mm. A one-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of Beijing Synchrotron Radiation Source. The data of the beam test were analyzed and some diffraction angles were obtained. The experimental results were in good agreement with standard data from ICDD powder diffraction file. The precision of diffraction angles was 1% to 4.7%. Most of the relative errors between measured values of diffraction angles and existing data were less than 1%. As for the detector, the best position resolution in the test was 138 p.m (a value) with an X-ray tube. Finally, discussions of the results were given. The major factor that affected the precision of measurement was deviation from the flat structure of the detector. The effect was analyzed and the conclusion was reached that it would be the optimal measurement scheme when the distance between the powder sample and detector was from 400 mm to 600 mm. |
Author | 刘梅 代洪亮 祁辉荣 庄保安 张建 刘荣光 朱启明 欧阳群 陈元柏 江晓山 王雅洁 刘鹏 常广才 |
AuthorAffiliation | State Key Laboratory of Particle Detection and Electronics, Beijing 100049, China CAS Key Laboratory for Biological Effects of Nanomaterials and Nanosafety, Beijing 100049, China Institute of High Energy Physics, Chinese Academy of Sciemces, Beijing 100049, China University of Chinese Academy of Sciences, Beijing 100049, China |
Author_xml | – sequence: 1 fullname: 刘梅 代洪亮 祁辉荣 庄保安 张建 刘荣光 朱启明 欧阳群 陈元柏 江晓山 王雅洁 刘鹏 常广才 |
BookMark | eNqFUE1LAzEQDVLBtvoXJN68rM3XJrvgRYtfUBBEzyHNJm1kN2mTrdB_b9ZKD16EBzPzeG-GeRMw8sEbAC4xusGoqmaYC1ZgTMUsA6OMCiF8AsaIlKygqCQjMD6KzsAkpU-EOMveMXi7N6qDvUk9DBYqmFcXjeuMTy541cJNSK7PLUwD1bsvA_VadUsT4UDuvV7H0MfcR9U4NUjPwalVbTIXv3UKPh4f3ufPxeL16WV-tyg05aQvGK8rjRphLTJ1zSrFcVMRUtpaW8oIskItiaDLUiC9JKUirDG24XlsCFNM0ym4PuzdxLDd5Q9k55I2bau8Cbsksagp4YSIKkv5QapjSCkaKzfRdSruJUZyCFEO-cghH5lxIHOI2Xj7x6hd__NlH5Vr_7df_drXwa-2zq-Oh5mgnKNK0G_M3IUn |
CitedBy_id | crossref_primary_10_7498_aps_64_082901 crossref_primary_10_1088_1748_0221_12_04_P04015 |
Cites_doi | 10.1016/0167-5087(82)90024-2 10.1016/0029-554X(78)90690-0 10.1016/0029-554X(68)90371-6 10.1016/j.nima.2007.06.114 10.1016/j.nima.2006.07.037 10.1002/9781118521014.ch3 |
ContentType | Journal Article |
DBID | 2RA 92L CQIGP ~WA AAYXX CITATION 7U5 8FD H8D L7M |
DOI | 10.1088/1674-1137/37/10/108001 |
DatabaseName | 维普期刊资源整合服务平台 中文科技期刊数据库-CALIS站点 中文科技期刊数据库-7.0平台 中文科技期刊数据库- 镜像站点 CrossRef Solid State and Superconductivity Abstracts Technology Research Database Aerospace Database Advanced Technologies Database with Aerospace |
DatabaseTitle | CrossRef Aerospace Database Solid State and Superconductivity Abstracts Technology Research Database Advanced Technologies Database with Aerospace |
DatabaseTitleList | Aerospace Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Physics |
DocumentTitleAlternate | Beam test of a one-dimensional position sensitive chamber on synchrotron radiation |
EISSN | 0254-3052 |
EndPage | 109 |
ExternalDocumentID | 10_1088_1674_1137_37_10_108001 47366087 |
GroupedDBID | 02O 1JI 1WK 29B 2B. 2C. 2RA 4.4 5B3 5GY 5VR 5VS 7.M 92E 92I 92L 92Q 93N AAGCD AAGID AAJIO AAJKP AALHV AATNI ABCXL ABHWH ABJNI ACAFW ACGFS ACHIP AENEX AFUIB AFYNE AIBLX AKPSB ALMA_UNASSIGNED_HOLDINGS ATQHT BBWZM CCEZO CCVFK CEBXE CHBEP CJUJL CQIGP CRLBU CW9 DU5 EBS EDWGO EJD EPQRW EQZZN ER. FA0 FEDTE HVGLF IJHAN IOP IZVLO JCGBZ KNG KOT M45 N5L NT- NT. OK1 PJBAE Q02 RIN RNS ROL RPA RW3 SY9 TCJ TGP W28 ~WA -SA -SC -S~ AAYXX ADEQX AERVB AOAED CAJEA CAJEC CITATION Q-- U1G U5K U5M 7U5 8FD AEINN H8D L7M |
ID | FETCH-LOGICAL-c362t-4698c0d7ff0e9948a61d8225f9cf3420f7ab273b570cb25a24defd6570d24a4c3 |
ISSN | 1674-1137 |
IngestDate | Fri Sep 05 09:08:19 EDT 2025 Thu Apr 24 23:03:06 EDT 2025 Tue Jul 01 03:03:10 EDT 2025 Wed Feb 14 10:39:41 EST 2024 |
IsDoiOpenAccess | false |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 10 |
Language | English |
License | http://iopscience.iop.org/info/page/text-and-data-mining http://iopscience.iop.org/page/copyright |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c362t-4698c0d7ff0e9948a61d8225f9cf3420f7ab273b570cb25a24defd6570d24a4c3 |
Notes | gaseous detector, synchrotron radiation, powder X-ray diffraction, ICDD-pdf 11-5641/O4 A one-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of Beijing Synchrotron Radiation Source. The data of the beam test were analyzed and some diffraction angles were obtained. The experimental results were in good agreement with standard data from ICDD powder diffraction file. The precision of diffraction angles was 1% to 4.7%. Most of the relative errors between measured values of diffraction angles and existing data were less than 1%. As for the detector, the best position resolution in the test was 138 p.m (a value) with an X-ray tube. Finally, discussions of the results were given. The major factor that affected the precision of measurement was deviation from the flat structure of the detector. The effect was analyzed and the conclusion was reached that it would be the optimal measurement scheme when the distance between the powder sample and detector was from 400 mm to 600 mm. ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
OpenAccessLink | https://iopscience.iop.org/article/10.1088/1674-1137/37/10/108001/pdf |
PQID | 1793262278 |
PQPubID | 23500 |
PageCount | 5 |
ParticipantIDs | proquest_miscellaneous_1793262278 crossref_primary_10_1088_1674_1137_37_10_108001 crossref_citationtrail_10_1088_1674_1137_37_10_108001 chongqing_primary_47366087 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2013-10-01 |
PublicationDateYYYYMMDD | 2013-10-01 |
PublicationDate_xml | – month: 10 year: 2013 text: 2013-10-01 day: 01 |
PublicationDecade | 2010 |
PublicationTitle | Chinese physics C |
PublicationTitleAlternate | Chinese Physica C |
PublicationYear | 2013 |
References | 1 2 3 4 5 6 (8) 2006 7 9 |
References_xml | – year: 2006 ident: 8 publication-title: PDF-ICDD Powder Diffraction File — 2 (Set 46-1045) – ident: 4 doi: 10.1016/0167-5087(82)90024-2 – ident: 5 doi: 10.1016/0029-554X(78)90690-0 – ident: 1 doi: 10.1016/0029-554X(68)90371-6 – ident: 3 doi: 10.1016/j.nima.2007.06.114 – ident: 9 – ident: 7 – ident: 2 doi: 10.1016/j.nima.2006.07.037 – ident: 6 doi: 10.1002/9781118521014.ch3 |
SSID | ssj0064088 |
Score | 1.9181237 |
Snippet | A one-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A... |
SourceID | proquest crossref chongqing |
SourceType | Aggregation Database Enrichment Source Index Database Publisher |
StartPage | 105 |
SubjectTerms | Beams (radiation) Chambers Detectors Deviation Diffraction Optimization Standard data Synchrotron radiation 一维 位置分辨率 光束 同步辐射光源 敏感 测试 粉末衍射 衍射实验 |
Title | Beam test of a one-dimensional position sensitive chamber on synchrotron radiation |
URI | http://lib.cqvip.com/qk/92043A/201310/47366087.html https://www.proquest.com/docview/1793262278 |
Volume | 37 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3da9swEBdbx2AvY58s7TY02FvQ4jiyZT-2o6UbWVtKAmEvQtZHE9jsNYkftr9-d5Zlp6OwbhCEfESyuftxOp_vg5D3eayFsDZiQpmccQEzJTLNwPQuxhaOCJVjgvOXs_R0zj8vkkWfrthkl2yLD_rXrXkl_yNVoIFcMUv2HyTbbQoEmIN8YQQJw3gnGR9Z9X0ItmKb5ViVlhms1u8rbQxDQNZwg6QmRkgvFXYAwU8Em5-lXq4rdIUP11ihoBNRKFywbNpTts6PTe9Pna7qxo9qV72f2ze_rsorNgXAXXX-VE-vV-yy6qlfl3Xrpj5SFTssd10P4z6ILWjLVHCQqq_aEtRpe9XCJtpRjhjO2C73Ry0G0yGJJbcqc1CA6FcIN4G5rw8QNUO_124N7bNzeTKfTuXseDG7Tx7E8PKADT0-nV-E8znlUdONtNs35I1n2aijjSZYkWDk74JlN5bApGswJm6aLzdP78YkmT0hj9t3CXrogfGU3LPlM_LwwovrOblEeFCEB60cVfQPeNAAD9rBg7bwoEjs4UE7eLwg85Pj2cdT1rbQYBosky3D_qA6MsK5yOY5z1Q6NmASJi7XbsLjyAlVgAFbJCLSRZyomBvrDIZDmZgrricvyV4Jj_eKUMdVGhsHNo-NOJidGXepGFsTx8oWRtgB2e-4JH_4UimSi0maRpkYkCSwTeq2-Dz2QPkmmyCILJPIeomsl_DzRGD9gIy6dWHPv614F6QiQVPi5y9V2qreSDyK4hRTv_fv8J8D8qiH_Guyt13X9g3Yn9vibQOn3_Wjfpw |
linkProvider | IOP Publishing |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Beam+test+of+a+one-dimensional+position+sensitive+chamber+on+synchrotron+radiation&rft.jtitle=Chinese+physics+C&rft.au=Liu%2C+Mei&rft.au=Dai%2C+Hong-Liang&rft.au=Qi%2C+Hui-Rong&rft.au=Zhuang%2C+Bao-An&rft.date=2013-10-01&rft.issn=1674-1137&rft.volume=37&rft.issue=10&rft.spage=108001&rft.epage=1-108001-5&rft_id=info:doi/10.1088%2F1674-1137%2F37%2F10%2F108001&rft.externalDBID=NO_FULL_TEXT |
thumbnail_s | http://utb.summon.serialssolutions.com/2.0.0/image/custom?url=http%3A%2F%2Fimage.cqvip.com%2Fvip1000%2Fqk%2F92043A%2F92043A.jpg |