Beam test of a one-dimensional position sensitive chamber on synchrotron radiation

A one-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of Beijing Synchrotron Radiation Source. The data of the beam te...

Full description

Saved in:
Bibliographic Details
Published inChinese physics C Vol. 37; no. 10; pp. 105 - 109
Main Author 刘梅 代洪亮 祁辉荣 庄保安 张建 刘荣光 朱启明 欧阳群 陈元柏 江晓山 王雅洁 刘鹏 常广才
Format Journal Article
LanguageEnglish
Published 01.10.2013
Subjects
Online AccessGet full text
ISSN1674-1137
0254-3052
DOI10.1088/1674-1137/37/10/108001

Cover

Loading…
Abstract A one-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of Beijing Synchrotron Radiation Source. The data of the beam test were analyzed and some diffraction angles were obtained. The experimental results were in good agreement with standard data from ICDD powder diffraction file. The precision of diffraction angles was 1% to 4.7%. Most of the relative errors between measured values of diffraction angles and existing data were less than 1%. As for the detector, the best position resolution in the test was 138 p.m (a value) with an X-ray tube. Finally, discussions of the results were given. The major factor that affected the precision of measurement was deviation from the flat structure of the detector. The effect was analyzed and the conclusion was reached that it would be the optimal measurement scheme when the distance between the powder sample and detector was from 400 mm to 600 mm.
AbstractList A one-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO sub(2) has been accomplished at 1W2B laboratory of Beijing Synchrotron Radiation Source. The data of the beam test were analyzed and some diffraction angles were obtained. The experimental results were in good agreement with standard data from ICDD powder diffraction file. The precision of diffraction angles was 1% to 4.7%. Most of the relative errors between measured values of diffraction angles and existing data were less than 1%. As for the detector, the best position resolution in the test was 138 mu m ([sigma] value) with an X-ray tube. Finally, discussions of the results were given. The major factor that affected the precision of measurement was deviation from the flat structure of the detector. The effect was analyzed and the conclusion was reached that it would be the optimal measurement scheme when the distance between the powder sample and detector was from 400 mm to 600 mm.
A one-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of Beijing Synchrotron Radiation Source. The data of the beam test were analyzed and some diffraction angles were obtained. The experimental results were in good agreement with standard data from ICDD powder diffraction file. The precision of diffraction angles was 1% to 4.7%. Most of the relative errors between measured values of diffraction angles and existing data were less than 1%. As for the detector, the best position resolution in the test was 138 p.m (a value) with an X-ray tube. Finally, discussions of the results were given. The major factor that affected the precision of measurement was deviation from the flat structure of the detector. The effect was analyzed and the conclusion was reached that it would be the optimal measurement scheme when the distance between the powder sample and detector was from 400 mm to 600 mm.
Author 刘梅 代洪亮 祁辉荣 庄保安 张建 刘荣光 朱启明 欧阳群 陈元柏 江晓山 王雅洁 刘鹏 常广才
AuthorAffiliation State Key Laboratory of Particle Detection and Electronics, Beijing 100049, China CAS Key Laboratory for Biological Effects of Nanomaterials and Nanosafety, Beijing 100049, China Institute of High Energy Physics, Chinese Academy of Sciemces, Beijing 100049, China University of Chinese Academy of Sciences, Beijing 100049, China
Author_xml – sequence: 1
  fullname: 刘梅 代洪亮 祁辉荣 庄保安 张建 刘荣光 朱启明 欧阳群 陈元柏 江晓山 王雅洁 刘鹏 常广才
BookMark eNqFUE1LAzEQDVLBtvoXJN68rM3XJrvgRYtfUBBEzyHNJm1kN2mTrdB_b9ZKD16EBzPzeG-GeRMw8sEbAC4xusGoqmaYC1ZgTMUsA6OMCiF8AsaIlKygqCQjMD6KzsAkpU-EOMveMXi7N6qDvUk9DBYqmFcXjeuMTy541cJNSK7PLUwD1bsvA_VadUsT4UDuvV7H0MfcR9U4NUjPwalVbTIXv3UKPh4f3ufPxeL16WV-tyg05aQvGK8rjRphLTJ1zSrFcVMRUtpaW8oIskItiaDLUiC9JKUirDG24XlsCFNM0ym4PuzdxLDd5Q9k55I2bau8Cbsksagp4YSIKkv5QapjSCkaKzfRdSruJUZyCFEO-cghH5lxIHOI2Xj7x6hd__NlH5Vr_7df_drXwa-2zq-Oh5mgnKNK0G_M3IUn
CitedBy_id crossref_primary_10_7498_aps_64_082901
crossref_primary_10_1088_1748_0221_12_04_P04015
Cites_doi 10.1016/0167-5087(82)90024-2
10.1016/0029-554X(78)90690-0
10.1016/0029-554X(68)90371-6
10.1016/j.nima.2007.06.114
10.1016/j.nima.2006.07.037
10.1002/9781118521014.ch3
ContentType Journal Article
DBID 2RA
92L
CQIGP
~WA
AAYXX
CITATION
7U5
8FD
H8D
L7M
DOI 10.1088/1674-1137/37/10/108001
DatabaseName 维普期刊资源整合服务平台
中文科技期刊数据库-CALIS站点
中文科技期刊数据库-7.0平台
中文科技期刊数据库- 镜像站点
CrossRef
Solid State and Superconductivity Abstracts
Technology Research Database
Aerospace Database
Advanced Technologies Database with Aerospace
DatabaseTitle CrossRef
Aerospace Database
Solid State and Superconductivity Abstracts
Technology Research Database
Advanced Technologies Database with Aerospace
DatabaseTitleList Aerospace Database

DeliveryMethod fulltext_linktorsrc
Discipline Physics
DocumentTitleAlternate Beam test of a one-dimensional position sensitive chamber on synchrotron radiation
EISSN 0254-3052
EndPage 109
ExternalDocumentID 10_1088_1674_1137_37_10_108001
47366087
GroupedDBID 02O
1JI
1WK
29B
2B.
2C.
2RA
4.4
5B3
5GY
5VR
5VS
7.M
92E
92I
92L
92Q
93N
AAGCD
AAGID
AAJIO
AAJKP
AALHV
AATNI
ABCXL
ABHWH
ABJNI
ACAFW
ACGFS
ACHIP
AENEX
AFUIB
AFYNE
AIBLX
AKPSB
ALMA_UNASSIGNED_HOLDINGS
ATQHT
BBWZM
CCEZO
CCVFK
CEBXE
CHBEP
CJUJL
CQIGP
CRLBU
CW9
DU5
EBS
EDWGO
EJD
EPQRW
EQZZN
ER.
FA0
FEDTE
HVGLF
IJHAN
IOP
IZVLO
JCGBZ
KNG
KOT
M45
N5L
NT-
NT.
OK1
PJBAE
Q02
RIN
RNS
ROL
RPA
RW3
SY9
TCJ
TGP
W28
~WA
-SA
-SC
-S~
AAYXX
ADEQX
AERVB
AOAED
CAJEA
CAJEC
CITATION
Q--
U1G
U5K
U5M
7U5
8FD
AEINN
H8D
L7M
ID FETCH-LOGICAL-c362t-4698c0d7ff0e9948a61d8225f9cf3420f7ab273b570cb25a24defd6570d24a4c3
ISSN 1674-1137
IngestDate Fri Sep 05 09:08:19 EDT 2025
Thu Apr 24 23:03:06 EDT 2025
Tue Jul 01 03:03:10 EDT 2025
Wed Feb 14 10:39:41 EST 2024
IsDoiOpenAccess false
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 10
Language English
License http://iopscience.iop.org/info/page/text-and-data-mining
http://iopscience.iop.org/page/copyright
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c362t-4698c0d7ff0e9948a61d8225f9cf3420f7ab273b570cb25a24defd6570d24a4c3
Notes gaseous detector, synchrotron radiation, powder X-ray diffraction, ICDD-pdf
11-5641/O4
A one-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of Beijing Synchrotron Radiation Source. The data of the beam test were analyzed and some diffraction angles were obtained. The experimental results were in good agreement with standard data from ICDD powder diffraction file. The precision of diffraction angles was 1% to 4.7%. Most of the relative errors between measured values of diffraction angles and existing data were less than 1%. As for the detector, the best position resolution in the test was 138 p.m (a value) with an X-ray tube. Finally, discussions of the results were given. The major factor that affected the precision of measurement was deviation from the flat structure of the detector. The effect was analyzed and the conclusion was reached that it would be the optimal measurement scheme when the distance between the powder sample and detector was from 400 mm to 600 mm.
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
OpenAccessLink https://iopscience.iop.org/article/10.1088/1674-1137/37/10/108001/pdf
PQID 1793262278
PQPubID 23500
PageCount 5
ParticipantIDs proquest_miscellaneous_1793262278
crossref_primary_10_1088_1674_1137_37_10_108001
crossref_citationtrail_10_1088_1674_1137_37_10_108001
chongqing_primary_47366087
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2013-10-01
PublicationDateYYYYMMDD 2013-10-01
PublicationDate_xml – month: 10
  year: 2013
  text: 2013-10-01
  day: 01
PublicationDecade 2010
PublicationTitle Chinese physics C
PublicationTitleAlternate Chinese Physica C
PublicationYear 2013
References 1
2
3
4
5
6
(8) 2006
7
9
References_xml – year: 2006
  ident: 8
  publication-title: PDF-ICDD Powder Diffraction File — 2 (Set 46-1045)
– ident: 4
  doi: 10.1016/0167-5087(82)90024-2
– ident: 5
  doi: 10.1016/0029-554X(78)90690-0
– ident: 1
  doi: 10.1016/0029-554X(68)90371-6
– ident: 3
  doi: 10.1016/j.nima.2007.06.114
– ident: 9
– ident: 7
– ident: 2
  doi: 10.1016/j.nima.2006.07.037
– ident: 6
  doi: 10.1002/9781118521014.ch3
SSID ssj0064088
Score 1.9181237
Snippet A one-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A...
SourceID proquest
crossref
chongqing
SourceType Aggregation Database
Enrichment Source
Index Database
Publisher
StartPage 105
SubjectTerms Beams (radiation)
Chambers
Detectors
Deviation
Diffraction
Optimization
Standard data
Synchrotron radiation
一维
位置分辨率
光束
同步辐射光源
敏感
测试
粉末衍射
衍射实验
Title Beam test of a one-dimensional position sensitive chamber on synchrotron radiation
URI http://lib.cqvip.com/qk/92043A/201310/47366087.html
https://www.proquest.com/docview/1793262278
Volume 37
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3da9swEBdbx2AvY58s7TY02FvQ4jiyZT-2o6UbWVtKAmEvQtZHE9jsNYkftr9-d5Zlp6OwbhCEfESyuftxOp_vg5D3eayFsDZiQpmccQEzJTLNwPQuxhaOCJVjgvOXs_R0zj8vkkWfrthkl2yLD_rXrXkl_yNVoIFcMUv2HyTbbQoEmIN8YQQJw3gnGR9Z9X0ItmKb5ViVlhms1u8rbQxDQNZwg6QmRkgvFXYAwU8Em5-lXq4rdIUP11ihoBNRKFywbNpTts6PTe9Pna7qxo9qV72f2ze_rsorNgXAXXX-VE-vV-yy6qlfl3Xrpj5SFTssd10P4z6ILWjLVHCQqq_aEtRpe9XCJtpRjhjO2C73Ry0G0yGJJbcqc1CA6FcIN4G5rw8QNUO_124N7bNzeTKfTuXseDG7Tx7E8PKADT0-nV-E8znlUdONtNs35I1n2aijjSZYkWDk74JlN5bApGswJm6aLzdP78YkmT0hj9t3CXrogfGU3LPlM_LwwovrOblEeFCEB60cVfQPeNAAD9rBg7bwoEjs4UE7eLwg85Pj2cdT1rbQYBosky3D_qA6MsK5yOY5z1Q6NmASJi7XbsLjyAlVgAFbJCLSRZyomBvrDIZDmZgrricvyV4Jj_eKUMdVGhsHNo-NOJidGXepGFsTx8oWRtgB2e-4JH_4UimSi0maRpkYkCSwTeq2-Dz2QPkmmyCILJPIeomsl_DzRGD9gIy6dWHPv614F6QiQVPi5y9V2qreSDyK4hRTv_fv8J8D8qiH_Guyt13X9g3Yn9vibQOn3_Wjfpw
linkProvider IOP Publishing
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Beam+test+of+a+one-dimensional+position+sensitive+chamber+on+synchrotron+radiation&rft.jtitle=Chinese+physics+C&rft.au=Liu%2C+Mei&rft.au=Dai%2C+Hong-Liang&rft.au=Qi%2C+Hui-Rong&rft.au=Zhuang%2C+Bao-An&rft.date=2013-10-01&rft.issn=1674-1137&rft.volume=37&rft.issue=10&rft.spage=108001&rft.epage=1-108001-5&rft_id=info:doi/10.1088%2F1674-1137%2F37%2F10%2F108001&rft.externalDBID=NO_FULL_TEXT
thumbnail_s http://utb.summon.serialssolutions.com/2.0.0/image/custom?url=http%3A%2F%2Fimage.cqvip.com%2Fvip1000%2Fqk%2F92043A%2F92043A.jpg