Computer-assisted quantification of occlusion and coil densities on angiographic and histological images of experimental aneurysms
Occlusion rates (OR) and coil densities were quantified by computer-assisted morphometry on angiograms and histological ground sections of coil-embolized experimental aneurysms. The aims of this study were 1) to develop computer-assisted evaluations of angiographic OR and histometrical OR, 2) to com...
Saved in:
Published in | Neurosurgery Vol. 58; no. 3; p. 559 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
United States
01.03.2006
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Abstract | Occlusion rates (OR) and coil densities were quantified by computer-assisted morphometry on angiograms and histological ground sections of coil-embolized experimental aneurysms. The aims of this study were 1) to develop computer-assisted evaluations of angiographic OR and histometrical OR, 2) to compare these results to subjectively estimated angiographic OR from clinical practice, and 3) to test the correlation between histometrical data of coil density and occlusion.
Eight rabbit carotid-bifurcation aneurysms had been followed by digital subtraction angiography (DSA) before and after Guglielmi detachable coil embolization and at sacrifice (1 h to 24 wk postembolization). Angiographic OR was subjectively estimated, then determined by computer-assisted density-gradient distinction on digitized DSAs. Histometrically, maximum length, neck width, total area, recanalized area, and coil-occupied area were measured on digitized and calibrated color micrographs from surface-stained histological ground sections of the aneurysms. Histometrical OR and coil density were calculated as indirect parameters.
Subjective versus computer-assisted angiographic OR yielded for one aneurysm, 100% versus 100%, and for three aneurysms less than 90% versus 65 to 60% occlusion. For four aneurysms, OR was estimated greater than 90%, whereas computer-assisted OR ranged between 45 to 80%, the latter being more precise because of better definition of the aneurysm's total area on digitized DSA. Histometrical OR ranged between 32.8 and 87.6%, but did not correlate significantly with computer-assisted angiographic OR (r = 0.467, P > 0.1) because of differences in two aneurysms. Coil densities between 5.5 and 22.1% were slightly lower than reported in literature but significantly correlated to histometrical OR (r = 0.646, P < 0.05).
Computer-assisted DSA evaluation, delivering more precise values than subjectively estimated occlusion, may be a useful tool for follow-up studies. Comparing computer-assisted angiographic with histometrical occlusion demonstrates limits of DSA in displaying the real morphology of coil-embolized aneurysms. The clinically postulated correlation of OR and coil densities was statistically corroborated. |
---|---|
AbstractList | Occlusion rates (OR) and coil densities were quantified by computer-assisted morphometry on angiograms and histological ground sections of coil-embolized experimental aneurysms. The aims of this study were 1) to develop computer-assisted evaluations of angiographic OR and histometrical OR, 2) to compare these results to subjectively estimated angiographic OR from clinical practice, and 3) to test the correlation between histometrical data of coil density and occlusion.
Eight rabbit carotid-bifurcation aneurysms had been followed by digital subtraction angiography (DSA) before and after Guglielmi detachable coil embolization and at sacrifice (1 h to 24 wk postembolization). Angiographic OR was subjectively estimated, then determined by computer-assisted density-gradient distinction on digitized DSAs. Histometrically, maximum length, neck width, total area, recanalized area, and coil-occupied area were measured on digitized and calibrated color micrographs from surface-stained histological ground sections of the aneurysms. Histometrical OR and coil density were calculated as indirect parameters.
Subjective versus computer-assisted angiographic OR yielded for one aneurysm, 100% versus 100%, and for three aneurysms less than 90% versus 65 to 60% occlusion. For four aneurysms, OR was estimated greater than 90%, whereas computer-assisted OR ranged between 45 to 80%, the latter being more precise because of better definition of the aneurysm's total area on digitized DSA. Histometrical OR ranged between 32.8 and 87.6%, but did not correlate significantly with computer-assisted angiographic OR (r = 0.467, P > 0.1) because of differences in two aneurysms. Coil densities between 5.5 and 22.1% were slightly lower than reported in literature but significantly correlated to histometrical OR (r = 0.646, P < 0.05).
Computer-assisted DSA evaluation, delivering more precise values than subjectively estimated occlusion, may be a useful tool for follow-up studies. Comparing computer-assisted angiographic with histometrical occlusion demonstrates limits of DSA in displaying the real morphology of coil-embolized aneurysms. The clinically postulated correlation of OR and coil densities was statistically corroborated. |
Author | Bavinzski, Gerhard Grossschmidt, Karl Plenk, Jr, Hanns Sherif, Camillo Kanz, Fabian |
Author_xml | – sequence: 1 givenname: Camillo surname: Sherif fullname: Sherif, Camillo organization: Department of Neurosurgery, Medical University of Vienna, Vienna, Austria – sequence: 2 givenname: Hanns surname: Plenk, Jr fullname: Plenk, Jr, Hanns – sequence: 3 givenname: Karl surname: Grossschmidt fullname: Grossschmidt, Karl – sequence: 4 givenname: Fabian surname: Kanz fullname: Kanz, Fabian – sequence: 5 givenname: Gerhard surname: Bavinzski fullname: Bavinzski, Gerhard |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/16528198$$D View this record in MEDLINE/PubMed |
BookMark | eNo1kE1LxDAQhoMo7of-BQneW5M0mbTHZVk_YNGLe17SNOlG2qQ2LbhXf7ndVWcOw7w8PAyzQJc-eIPQPSUpZUw-EJq-bnYpmYoWkhckBQKSpKv8As2pYDzhhJMZWsT4MSHAZX6NZhQEy2mRz9H3OrTdOJg-UTG6OJgKf47KD846rQYXPA4WB62bMZ4W5Susg2twZXx0gzMRn9PahbpX3cHpM3KYTKEJ9eRosGtVfeIsNl-d6V1r_DDFypuxP8Y23qArq5pobv_mEu0eN-_r52T79vSyXm0TnQErEskywYVUBIxgwDk3pQQqQduMUcuMZQUHKTglUpQMps6zsgRbARUgc8KW6O7X241la6p9N52i-uP-_xnsB80bZTY |
CitedBy_id | crossref_primary_10_1136_neurintsurg_2017_013481 crossref_primary_10_1002_jemt_21094 crossref_primary_10_3174_ajnr_A2843 crossref_primary_10_1016_j_wneu_2018_02_096 crossref_primary_10_1007_s00701_009_0237_1 crossref_primary_10_1007_s00701_010_0867_3 crossref_primary_10_1007_s13239_012_0113_7 crossref_primary_10_3174_ajnr_A3085 crossref_primary_10_1007_s10237_018_1059_y crossref_primary_10_1179_1743132812Y_0000000040 crossref_primary_10_3174_ajnr_A2302 crossref_primary_10_3174_ajnr_A2335 crossref_primary_10_3174_ajnr_A2235 crossref_primary_10_1002_jbm_b_31660 crossref_primary_10_1007_s00701_010_0615_8 crossref_primary_10_3174_ajnr_A1463 crossref_primary_10_1007_s10143_017_0892_2 crossref_primary_10_1016_j_jneumeth_2016_04_020 crossref_primary_10_1039_b707177a |
ContentType | Journal Article |
DBID | CGR CUY CVF ECM EIF NPM |
DOI | 10.1227/01.NEU.0000197490.60670.A8 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
EISSN | 1524-4040 |
ExternalDocumentID | 16528198 |
Genre | Journal Article Comparative Study |
GroupedDBID | --- .-D .3C .55 .GJ .Z2 01R 0R~ 123 1TH 354 3O- 3V. 40H 48X 4Q1 4Q2 4Q3 53G 5RE 5VS 71W 77Y 7O~ 7X7 88E 8FI 8FJ A9M AAAAV AAAXR AAGIX AAHPQ AAIQE AAJQQ AAKAS AAPQZ AAQKA AAQOH AAQQT AARTV AASCR AASOK AASXQ AAUQX AAVAP AAYEP ABASU ABDIG ABHFT ABJNI ABLJU ABOCM ABPPZ ABPTD ABSAR ABUWG ABZAD ACDDN ACFRR ACGFO ACGFS ACILI ACOAL ACUTJ ACWRI ACXJB ACXNZ ADBBV ADBIZ ADFPA ADGZP ADHKW ADHPY ADRTK ADZCM AE3 AE6 AEETU AEMDU AENEX AENZO AETBJ AEWNT AFDTB AFFZL AFKRA AFOFC AFTRI AFUWQ AGINI AGINJ AGKRT AHMBA AHOMT AHQNM AHRYX AHVBC AIZYK AJNWD AJNYG AJZMW ALIPV ALMA_UNASSIGNED_HOLDINGS AMNEI APIBT AQDSO AQKUS ASAOO ATDFG AWKKM BAYMD BCRHZ BENPR BOYCO BPHCQ BS7 BTRTY BVXVI BYPQX C45 CCPQU CDBKE CGR CS3 CUY CVF DAKXR E.X EBS ECM EEVPB EIF EIHJH EJD ELUNK ENERS ERAAH EX3 F2K F2L F2M F2N F5P FCALG FECEO FL- FLUFQ FOEOM FOTVD FQBLK FW0 FYUFA GAUVT GJXCC H0~ H13 HLJTE HMCUK HZ~ IAO IHR INH INR IN~ IPNFZ J5H JF7 JF9 JG8 JK3 JK8 K8S KD2 KMI KOP KSI KSN L-C L7B LMP M18 M1P MBLQV MBTAY MHKGH N4W N9A NOYVH NPM NVLIB N~7 N~B N~M O9- OAG OAH OBH OCUKA ODA ODMLO OHH OL1 OLB OLG OLH OLU OLV OLY OLZ ORVUJ OVD OWU OWV OWW OWX OWY OWZ P-K P2P PAFKI PEELM PQQKQ PROAC PSQYO R58 RIG RLZ ROX ROZ RUSNO RXW S4R SJN TEORI TJX UKHRP V2I VVN W3M WOQ WOW X3V X3W X7M XXN XYM YAYTL YCJ YFH YKOAZ YOC YXANX ZCG ZFV ZGI ZXP ZY1 |
ID | FETCH-LOGICAL-c3629-7235457a06e526444eb76176cf321f2ef29467541075b2626283bb6fd61567802 |
IngestDate | Sat Sep 28 07:44:22 EDT 2024 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 3 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c3629-7235457a06e526444eb76176cf321f2ef29467541075b2626283bb6fd61567802 |
PMID | 16528198 |
ParticipantIDs | pubmed_primary_16528198 |
PublicationCentury | 2000 |
PublicationDate | 2006-Mar |
PublicationDateYYYYMMDD | 2006-03-01 |
PublicationDate_xml | – month: 03 year: 2006 text: 2006-Mar |
PublicationDecade | 2000 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Neurosurgery |
PublicationTitleAlternate | Neurosurgery |
PublicationYear | 2006 |
SSID | ssj0016478 |
Score | 1.9726024 |
Snippet | Occlusion rates (OR) and coil densities were quantified by computer-assisted morphometry on angiograms and histological ground sections of coil-embolized... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 559 |
SubjectTerms | Aneurysm - pathology Aneurysm - therapy Angiography, Digital Subtraction - methods Animals Carotid Artery Diseases - pathology Carotid Artery Diseases - therapy Embolization, Therapeutic Image Processing, Computer-Assisted - methods Rabbits |
Title | Computer-assisted quantification of occlusion and coil densities on angiographic and histological images of experimental aneurysms |
URI | https://www.ncbi.nlm.nih.gov/pubmed/16528198 |
Volume | 58 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Nb9QwELW2cOGCQHyWD_nArUrIep04OVaosCpiT12pt8pO4iqom1Tq9gBHfg8_kjf-SNOWSoWLFdmJFWVexm-SmWfGPlhVSCUrnVRl0yRSZTgCK000FcsUpgBHoQLnb6tiuZaHx_nxbPZ7krV0uTVp_fOvdSX_Y1X0wa5UJfsPlh0nRQeOYV-0sDDae9k4bsmQgAGTuRqqkfTZPyMTHOr67PIiJh3XQ3e211DSOgmp7rne087LVgflVqdAHD1it9GnXpb22lYAmmQwf1wEpfPvUQGKpDEnZdZB-bGzPrOENjgaRleM1c454kMHmaXu-5Hdf6GVG1H3pmu2oWBtzAP5Ci7rCLc2EdiTbxYxaSttg58VEqGrV2qKjjgvJ4BbTLxq7kXDb3l7IZSrYEhXB2snRDlHdFRlaUHFR-l-Ob0IljvfOBzMi5z-Ht5j9IYSdxzaYTuqJG-6oi9D4Y8V1ewGUVvc1se7b4pkasNEN0IZR2mOnrDHIRbh-x5YT9ms7Z-xX7dAxa-Dig-Wj6DiQAwnUPERVNz1XoHKnTIFFfegonmmoOIjqJ6z9eeDo0_LJGzUkdTgP1WixAJEXOmsaHMi2LI1Csy4qO1CzK1oraiwHudyDn5qBEJocFpjCtuAToMsZeIFe9APffuKcax3oslrq9BIW8nSaJyQNbWoEci0-jV76R_ZyblXYzmJD3P3zpE37NEVCN-yhxavf_sOXHJr3jsj_gGDJXZo |
link.rule.ids | 786 |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Computer-assisted+quantification+of+occlusion+and+coil+densities+on+angiographic+and+histological+images+of+experimental+aneurysms&rft.jtitle=Neurosurgery&rft.au=Sherif%2C+Camillo&rft.au=Plenk%2C+Jr%2C+Hanns&rft.au=Grossschmidt%2C+Karl&rft.au=Kanz%2C+Fabian&rft.date=2006-03-01&rft.eissn=1524-4040&rft.volume=58&rft.issue=3&rft.spage=559&rft_id=info:doi/10.1227%2F01.NEU.0000197490.60670.A8&rft_id=info%3Apmid%2F16528198&rft_id=info%3Apmid%2F16528198&rft.externalDocID=16528198 |