Contact force and ablation assessment of surgical bipolar radiofrequency clamps in the treatment of atrial fibrillation
Abstract OBJECTIVES Atrial fibrillation is treated surgically by creating conduction block lesions. Radiofrequency (RF) lesions have reduced efficacy compared to ‘cut-and-sew’. Catheter ablation studies demonstrate a relationship between lesion depth and contact force. We hypothesized that contact f...
Saved in:
Published in | Interactive cardiovascular and thoracic surgery Vol. 28; no. 1; pp. 85 - 93 |
---|---|
Main Authors | , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
England
Oxford University Press
01.01.2019
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Abstract
OBJECTIVES
Atrial fibrillation is treated surgically by creating conduction block lesions. Radiofrequency (RF) lesions have reduced efficacy compared to ‘cut-and-sew’. Catheter ablation studies demonstrate a relationship between lesion depth and contact force. We hypothesized that contact force and lesion depth are dependent on design of the bipolar surgical RF clamps.
METHODS
Hinged and parallel jaw style RF clamps were studied. Muscle samples were clamped with pressure-sensitive film at increasing tissue thicknesses. Films were analysed determining clamp pressure profiles. A sheep model was utilized for ablation testing using each clamp style until the device indicated transmurality. Separate muscle areas had 1, 2 or 3 burns applied. The muscle was excised, sectioned every 1 cm and stained for lesion depth and fat thickness analysis.
RESULTS
Pressure profiling comparing the proximal and distal segments of each clamp style demonstrated only one statistically significant difference in the parallel clamp; the hinged clamp had statistically significant differences (P ≤ 0.03) for all tissue thicknesses. There was no evidence for differences in the proximal lesion depth of both clamps (P = 0.13) but deeper distally in the parallel clamp (10.17 mm vs 8.02 mm, P = 0.003). The logistic regression analysis demonstrated increased odds of transmurality with parallel clamps at 1, 2 or 3 burns (P = 0.03, P = 0.003 and P = 0.002). Every 1 mm increase in overlying fat decreased likelihood of transmurality by 11% (P < 0.05).
CONCLUSIONS
The parallel and hinged clamps have different pressure profiles with higher likelihood of transmurality using the parallel clamp. Fat reduces the ability of RF to deliver a transmural lesion. These findings have implications for optimal surgical RF ablation technique. |
---|---|
AbstractList | Atrial fibrillation is treated surgically by creating conduction block lesions. Radiofrequency (RF) lesions have reduced efficacy compared to 'cut-and-sew'. Catheter ablation studies demonstrate a relationship between lesion depth and contact force. We hypothesized that contact force and lesion depth are dependent on design of the bipolar surgical RF clamps.
Hinged and parallel jaw style RF clamps were studied. Muscle samples were clamped with pressure-sensitive film at increasing tissue thicknesses. Films were analysed determining clamp pressure profiles. A sheep model was utilized for ablation testing using each clamp style until the device indicated transmurality. Separate muscle areas had 1, 2 or 3 burns applied. The muscle was excised, sectioned every 1 cm and stained for lesion depth and fat thickness analysis.
Pressure profiling comparing the proximal and distal segments of each clamp style demonstrated only one statistically significant difference in the parallel clamp; the hinged clamp had statistically significant differences (P ≤ 0.03) for all tissue thicknesses. There was no evidence for differences in the proximal lesion depth of both clamps (P = 0.13) but deeper distally in the parallel clamp (10.17 mm vs 8.02 mm, P = 0.003). The logistic regression analysis demonstrated increased odds of transmurality with parallel clamps at 1, 2 or 3 burns (P = 0.03, P = 0.003 and P = 0.002). Every 1 mm increase in overlying fat decreased likelihood of transmurality by 11% (P < 0.05).
The parallel and hinged clamps have different pressure profiles with higher likelihood of transmurality using the parallel clamp. Fat reduces the ability of RF to deliver a transmural lesion. These findings have implications for optimal surgical RF ablation technique. OBJECTIVESAtrial fibrillation is treated surgically by creating conduction block lesions. Radiofrequency (RF) lesions have reduced efficacy compared to 'cut-and-sew'. Catheter ablation studies demonstrate a relationship between lesion depth and contact force. We hypothesized that contact force and lesion depth are dependent on design of the bipolar surgical RF clamps. METHODSHinged and parallel jaw style RF clamps were studied. Muscle samples were clamped with pressure-sensitive film at increasing tissue thicknesses. Films were analysed determining clamp pressure profiles. A sheep model was utilized for ablation testing using each clamp style until the device indicated transmurality. Separate muscle areas had 1, 2 or 3 burns applied. The muscle was excised, sectioned every 1 cm and stained for lesion depth and fat thickness analysis. RESULTSPressure profiling comparing the proximal and distal segments of each clamp style demonstrated only one statistically significant difference in the parallel clamp; the hinged clamp had statistically significant differences (P ≤ 0.03) for all tissue thicknesses. There was no evidence for differences in the proximal lesion depth of both clamps (P = 0.13) but deeper distally in the parallel clamp (10.17 mm vs 8.02 mm, P = 0.003). The logistic regression analysis demonstrated increased odds of transmurality with parallel clamps at 1, 2 or 3 burns (P = 0.03, P = 0.003 and P = 0.002). Every 1 mm increase in overlying fat decreased likelihood of transmurality by 11% (P < 0.05). CONCLUSIONSThe parallel and hinged clamps have different pressure profiles with higher likelihood of transmurality using the parallel clamp. Fat reduces the ability of RF to deliver a transmural lesion. These findings have implications for optimal surgical RF ablation technique. Abstract OBJECTIVES Atrial fibrillation is treated surgically by creating conduction block lesions. Radiofrequency (RF) lesions have reduced efficacy compared to ‘cut-and-sew’. Catheter ablation studies demonstrate a relationship between lesion depth and contact force. We hypothesized that contact force and lesion depth are dependent on design of the bipolar surgical RF clamps. METHODS Hinged and parallel jaw style RF clamps were studied. Muscle samples were clamped with pressure-sensitive film at increasing tissue thicknesses. Films were analysed determining clamp pressure profiles. A sheep model was utilized for ablation testing using each clamp style until the device indicated transmurality. Separate muscle areas had 1, 2 or 3 burns applied. The muscle was excised, sectioned every 1 cm and stained for lesion depth and fat thickness analysis. RESULTS Pressure profiling comparing the proximal and distal segments of each clamp style demonstrated only one statistically significant difference in the parallel clamp; the hinged clamp had statistically significant differences (P ≤ 0.03) for all tissue thicknesses. There was no evidence for differences in the proximal lesion depth of both clamps (P = 0.13) but deeper distally in the parallel clamp (10.17 mm vs 8.02 mm, P = 0.003). The logistic regression analysis demonstrated increased odds of transmurality with parallel clamps at 1, 2 or 3 burns (P = 0.03, P = 0.003 and P = 0.002). Every 1 mm increase in overlying fat decreased likelihood of transmurality by 11% (P < 0.05). CONCLUSIONS The parallel and hinged clamps have different pressure profiles with higher likelihood of transmurality using the parallel clamp. Fat reduces the ability of RF to deliver a transmural lesion. These findings have implications for optimal surgical RF ablation technique. |
Author | Worthington, Michael Varzaly, Jason A Louise, Jennie Lau, Dennis H Chapman, Darius Edwards, Suzanne Edwards, James Mahajan, Rajiv Sanders, Prashanthan |
Author_xml | – sequence: 1 givenname: Jason A surname: Varzaly fullname: Varzaly, Jason A organization: Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, University of Adelaide, Adelaide, Australia – sequence: 2 givenname: Darius surname: Chapman fullname: Chapman, Darius organization: Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, University of Adelaide, Adelaide, Australia – sequence: 3 givenname: Dennis H surname: Lau fullname: Lau, Dennis H organization: Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, University of Adelaide, Adelaide, Australia – sequence: 4 givenname: Suzanne surname: Edwards fullname: Edwards, Suzanne organization: Department of Public Health, Data, Design and Statistics Service, Adelaide Health Technology Assessment, University of Adelaide, Adelaide, Australia – sequence: 5 givenname: Jennie surname: Louise fullname: Louise, Jennie organization: Department of Public Health, Data, Design and Statistics Service, Adelaide Health Technology Assessment, University of Adelaide, Adelaide, Australia – sequence: 6 givenname: James surname: Edwards fullname: Edwards, James organization: Department of Cardiothoracic Surgery, Royal Adelaide Hospital, Adelaide, Australia – sequence: 7 givenname: Rajiv surname: Mahajan fullname: Mahajan, Rajiv organization: Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, University of Adelaide, Adelaide, Australia – sequence: 8 givenname: Michael surname: Worthington fullname: Worthington, Michael organization: Department of Cardiothoracic Surgery, Royal Adelaide Hospital, Adelaide, Australia – sequence: 9 givenname: Prashanthan surname: Sanders fullname: Sanders, Prashanthan email: prash.sanders@adelaide.edu.au organization: Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, University of Adelaide, Adelaide, Australia |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/29982423$$D View this record in MEDLINE/PubMed |
BookMark | eNp9kDtPwzAUhS1URFtgY0beYCDgR5zGI6p4SZVYYI6uHQeMEjvYTlH_PYEAI9O9w3eOjr4lmjnvDEInlFxSIvmV1dsUr-x2RyXdQwsqCplJVorZ3y_5HC1jfCOESsLJAZozKUuWM75AH2vvEuiEGx-0weBqDKqFZL3DEKOJsTMuYd_gOIQXq6HFyva-hYAD1NY3wbwPxukd1i10fcTW4fRqcAoG0m8UUrBjsLEq2HYqP0L7DbTRHP_cQ_R8e_O0vs82j3cP6-tNpnlBU1bAipeKCJYrCXVtlCqBEZlzJvK6FFRTkxdlTSTkhBslNBOF4CVQAKBCKn6IzqfePvhxaExVZ6M24wpn_BArRooV5VSs8hG9mFAdfIzBNFUfbAdhV1FSfamuvlVXk-oRP_1pHlRn6j_41-0InE2AH_r_qz4B7C2NnA |
CitedBy_id | crossref_primary_10_1097_CM9_0000000000000276 crossref_primary_10_1016_j_ijcard_2024_131749 crossref_primary_10_1016_j_hrthm_2024_03_017 crossref_primary_10_1007_s10840_024_01771_5 crossref_primary_10_1016_j_athoracsur_2023_02_055 crossref_primary_10_1093_europace_euae043 crossref_primary_10_1161_CIRCEP_118_007088 crossref_primary_10_3389_fcvm_2024_1335407 |
Cites_doi | 10.1111/j.1540-8167.2009.01693.x 10.1016/j.hrthm.2013.10.004 10.1111/j.1540-8167.2010.01750.x 10.1093/europace/euv057 10.1016/S0022-5223(19)36684-X 10.1161/CIRCEP.108.803650 10.1016/j.hrthm.2015.12.033 10.1161/CIRCEP.113.000184 10.1016/j.hrthm.2012.07.016 10.1016/j.athoracsur.2015.07.027 10.1161/CIRCEP.111.962720 10.1016/j.jtcvs.2004.02.044 10.1097/MAT.0b013e3182a394f1 10.1016/j.jtcvs.2006.09.115 |
ContentType | Journal Article |
Copyright | The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved. 2018 |
Copyright_xml | – notice: The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved. 2018 |
DBID | NPM AAYXX CITATION 7X8 |
DOI | 10.1093/icvts/ivy191 |
DatabaseName | PubMed CrossRef MEDLINE - Academic |
DatabaseTitle | PubMed CrossRef MEDLINE - Academic |
DatabaseTitleList | PubMed MEDLINE - Academic |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
EISSN | 1569-9285 |
EndPage | 93 |
ExternalDocumentID | 10_1093_icvts_ivy191 29982423 10.1093/icvts/ivy191 |
Genre | Research Support, Non-U.S. Gov't Journal Article |
GrantInformation_xml | – fundername: National Heart Foundation of Australia funderid: 10.13039/501100001030 – fundername: National Health and Medical Research Council of Australia – fundername: Centre for Heart Rhythm Disorders – fundername: Postgraduate Scholarship from the University of Adelaide |
GroupedDBID | --- 0R~ 18M 29J 2WC 4.4 48X 5GY AAIYJ AAJKP AAOGV AAPXW AAVAP ABKDP ABNKS ABOCM ABPTD ABQLI ABXVV ABZBJ ACGFO ACGFS ADBBV ADEYI ADHKW ADJQC ADOCK ADRIX ADRTK ADYVW ADZXQ AEGPL AEJOX AEKSI AENEX AEPUE AFOFC AFULF AFXEN AGINJ ALMA_UNASSIGNED_HOLDINGS AWCFO AXUDD BAWUL BAYMD BHONS CS3 DIK DPORF DPPUQ DU5 E3Z EBD EBS EE~ EJD EMOBN F5P F9B GX1 H13 H5~ HZ~ KBUDW KSI M~E O9- OK1 O~Y RNS ROX RPM RXO SV3 TEU TJX TOX TR2 W8F WOQ XSB ZCN NPM AAYXX ABEJV CITATION 7X8 |
ID | FETCH-LOGICAL-c361t-6a738b0524b9addebb8a20943254d851c1e468d09a403eb5c256538a1aaa159b3 |
IEDL.DBID | TOX |
ISSN | 1569-9293 1569-9285 |
IngestDate | Wed Dec 04 12:23:15 EST 2024 Fri Dec 06 09:29:06 EST 2024 Wed Oct 16 00:50:07 EDT 2024 Wed Aug 28 03:19:36 EDT 2024 |
IsDoiOpenAccess | false |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 1 |
Keywords | Lesion Contact force Radiofrequency Ablation Surgery Atrial fibrillation |
Language | English |
License | This article is published and distributed under the terms of the Oxford University Press, Standard Journals Publication Model (https://academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model) https://academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c361t-6a738b0524b9addebb8a20943254d851c1e468d09a403eb5c256538a1aaa159b3 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
OpenAccessLink | https://academic.oup.com/icvts/article-pdf/28/1/85/28013303/ivy191.pdf |
PMID | 29982423 |
PQID | 2067131574 |
PQPubID | 23479 |
PageCount | 9 |
ParticipantIDs | proquest_miscellaneous_2067131574 crossref_primary_10_1093_icvts_ivy191 pubmed_primary_29982423 oup_primary_10_1093_icvts_ivy191 |
PublicationCentury | 2000 |
PublicationDate | 20190101 2019-01-01 |
PublicationDateYYYYMMDD | 2019-01-01 |
PublicationDate_xml | – month: 01 year: 2019 text: 20190101 day: 01 |
PublicationDecade | 2010 |
PublicationPlace | England |
PublicationPlace_xml | – name: England |
PublicationTitle | Interactive cardiovascular and thoracic surgery |
PublicationTitleAlternate | Interact Cardiovasc Thorac Surg |
PublicationYear | 2019 |
Publisher | Oxford University Press |
Publisher_xml | – name: Oxford University Press |
References | Cox ( key 2019030510361576300_ivy191-B1) 1991; 101 Gaynor ( key 2019030510361576300_ivy191-B2) 2004; 128 Melby ( key 2019030510361576300_ivy191-B4) 2013; 59 Stulak ( key 2019030510361576300_ivy191-B5) 2007; 133 Ho ( key 2019030510361576300_ivy191-B14) 2012; 5 Takahashi ( key 2019030510361576300_ivy191-B13) 2016; 13 Thiagalingam ( key 2019030510361576300_ivy191-B8) 2010; 21 Yokoyama ( key 2019030510361576300_ivy191-B9) 2008; 1 Wong ( key 2019030510361576300_ivy191-B6) 2013; 6 Kasirajan ( key 2019030510361576300_ivy191-B12) 2016; 101 Shah ( key 2019030510361576300_ivy191-B7) 2010; 21 Reddy ( key 2019030510361576300_ivy191-B10) 2012; 9 Kautzner ( key 2019030510361576300_ivy191-B11) 2015; 17 Damiano ( key 2019030510361576300_ivy191-B3) 2014; 11 |
References_xml | – volume: 21 start-page: 806 year: 2010 ident: key 2019030510361576300_ivy191-B8 article-title: Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter publication-title: J Cardiovasc Electrophysiol doi: 10.1111/j.1540-8167.2009.01693.x contributor: fullname: Thiagalingam – volume: 11 start-page: 39 year: 2014 ident: key 2019030510361576300_ivy191-B3 article-title: The CURE-AF trial: a prospective, multicenter trial of irrigated radiofrequency ablation for the treatment of persistent atrial fibrillation during concomitant cardiac surgery publication-title: Heart Rhythm doi: 10.1016/j.hrthm.2013.10.004 contributor: fullname: Damiano – volume: 21 start-page: 1038 year: 2010 ident: key 2019030510361576300_ivy191-B7 article-title: Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model publication-title: J Cardiovasc Electrophysiol doi: 10.1111/j.1540-8167.2010.01750.x contributor: fullname: Shah – volume: 17 start-page: 1229 year: 2015 ident: key 2019030510361576300_ivy191-B11 article-title: EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation publication-title: Europace doi: 10.1093/europace/euv057 contributor: fullname: Kautzner – volume: 101 start-page: 569 year: 1991 ident: key 2019030510361576300_ivy191-B1 article-title: The surgical treatment of atrial fibrillation. III. Development of a definitive surgical procedure publication-title: J Thoracic Cardiovasc Surg doi: 10.1016/S0022-5223(19)36684-X contributor: fullname: Cox – volume: 1 start-page: 354 year: 2008 ident: key 2019030510361576300_ivy191-B9 article-title: Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus publication-title: Circ Arrhythm Electrophysiol doi: 10.1161/CIRCEP.108.803650 contributor: fullname: Yokoyama – volume: 13 start-page: 1059 year: 2016 ident: key 2019030510361576300_ivy191-B13 article-title: Mechanisms of postoperative atrial tachycardia following biatrial surgical ablation of atrial fibrillation in relation to the surgical lesion sets publication-title: Heart Rhythm doi: 10.1016/j.hrthm.2015.12.033 contributor: fullname: Takahashi – volume: 6 start-page: 1222 year: 2013 ident: key 2019030510361576300_ivy191-B6 article-title: Characterization of catheter-tissue contact force during epicardial radiofrequency ablation in an ovine model publication-title: Circ Arrhythm Electrophysiol doi: 10.1161/CIRCEP.113.000184 contributor: fullname: Wong – volume: 9 start-page: 1789 year: 2012 ident: key 2019030510361576300_ivy191-B10 article-title: The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study publication-title: Heart Rhythm doi: 10.1016/j.hrthm.2012.07.016 contributor: fullname: Reddy – volume: 101 start-page: 638 year: 2016 ident: key 2019030510361576300_ivy191-B12 article-title: Histopathology of bipolar radiofrequency ablation in the human atrium publication-title: Ann Thorac Surg doi: 10.1016/j.athoracsur.2015.07.027 contributor: fullname: Kasirajan – volume: 5 start-page: 220 year: 2012 ident: key 2019030510361576300_ivy191-B14 article-title: Left atrial anatomy revisited publication-title: Circ Arrhythm Electrophysiol doi: 10.1161/CIRCEP.111.962720 contributor: fullname: Ho – volume: 128 start-page: 535 year: 2004 ident: key 2019030510361576300_ivy191-B2 article-title: A prospective, single-center clinical trial of a modified Cox maze procedure with bipolar radiofrequency ablation publication-title: J Thorac Cardiovasc Surg doi: 10.1016/j.jtcvs.2004.02.044 contributor: fullname: Gaynor – volume: 59 start-page: 461 year: 2013 ident: key 2019030510361576300_ivy191-B4 article-title: Ablation technology for the surgical treatment of atrial fibrillation publication-title: ASAIO J doi: 10.1097/MAT.0b013e3182a394f1 contributor: fullname: Melby – volume: 133 start-page: 1022 year: 2007 ident: key 2019030510361576300_ivy191-B5 article-title: Superiority of cut-and-sew technique for the Cox maze procedure: comparison with radiofrequency ablation publication-title: J Thorac Cardiovasc Surg doi: 10.1016/j.jtcvs.2006.09.115 contributor: fullname: Stulak |
SSID | ssj0019030 |
Score | 2.272776 |
Snippet | Abstract
OBJECTIVES
Atrial fibrillation is treated surgically by creating conduction block lesions. Radiofrequency (RF) lesions have reduced efficacy compared... Atrial fibrillation is treated surgically by creating conduction block lesions. Radiofrequency (RF) lesions have reduced efficacy compared to 'cut-and-sew'.... OBJECTIVESAtrial fibrillation is treated surgically by creating conduction block lesions. Radiofrequency (RF) lesions have reduced efficacy compared to... |
SourceID | proquest crossref pubmed oup |
SourceType | Aggregation Database Index Database Publisher |
StartPage | 85 |
Title | Contact force and ablation assessment of surgical bipolar radiofrequency clamps in the treatment of atrial fibrillation |
URI | https://www.ncbi.nlm.nih.gov/pubmed/29982423 https://search.proquest.com/docview/2067131574 |
Volume | 28 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwhV1LS8NAEF6kJy-i-KovVtDj0mw22WyOIpYiqJcWegv7CgQkKUla6b93NpsGqoKnXLIbmH3MN5lvvkHoIeZCcDhDJNexIZHijEgAJkSY2ORWpdKErnb47Z3PFtHrMl72IknNHyn8lE0KvWmbSbHZ0q5KnfLAaeTPP5ZDtiANup4iEIqkBNw96wnuPwfvuZ69crZfqLLzLtNjdNTDQvzk1_EEHdjyFH056SipWwzAUlsMMT-WynPXsBwUNXGV42ZddzcYVsXKxaq4lqao8trzpLdYw7qvGlyUGPAeHsjlbqjs-nbg3FH_P_3kZ2gxfZk_z0jfKIFoxmlLuEyYUEEcRs64xiolZOgogxD9GYBUmtqICxOkMgqYVbEGnAMXnaRSSoAzip2jUVmV9hLhQEWBicLAUniIVIqc2zxkTButYpEkY_S4s2G28noYmc9js6yzdeZtPUYYDPzPK_c762ewp12iQpa2WjeZk5SnjMZJNEYXflmGmcB9CocBr_7_wDU6BHiT-h8mN2jU1mt7CxCiVXfd_vkGpDnHzA |
link.rule.ids | 314,780,784,1604,27924,27925 |
linkProvider | Oxford University Press |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Contact+force+and+ablation+assessment+of+surgical+bipolar+radiofrequency+clamps+in+the+treatment+of+atrial+fibrillation&rft.jtitle=Interactive+cardiovascular+and+thoracic+surgery&rft.au=Varzaly%2C+Jason+A&rft.au=Chapman%2C+Darius&rft.au=Lau%2C+Dennis+H&rft.au=Edwards%2C+Suzanne&rft.date=2019-01-01&rft.issn=1569-9285&rft.eissn=1569-9285&rft.volume=28&rft.issue=1&rft.spage=85&rft.epage=93&rft_id=info:doi/10.1093%2Ficvts%2Fivy191&rft.externalDBID=n%2Fa&rft.externalDocID=10_1093_icvts_ivy191 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1569-9293&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1569-9293&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1569-9293&client=summon |