Parametric Finite Element Analysis of Intramedullary Nail Fixation of Proximal Femur Fractures

ABSTRACT Proximal femur fracture fixation with intramedullary nailing relies on stability at the fracture site and integrity of the fixation construct to achieve union. The biomechanics that dictate fracture site stability and implant stress depend on fracture type as well as implant features such a...

Full description

Saved in:
Bibliographic Details
Published inJournal of orthopaedic research Vol. 37; no. 11; pp. 2358 - 2366
Main Authors Tucker, Scott M., Wee, Hwabok, Fox, Edward, Reid, J. Spence, Lewis, Gregory S.
Format Journal Article
LanguageEnglish
Published United States 01.11.2019
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:ABSTRACT Proximal femur fracture fixation with intramedullary nailing relies on stability at the fracture site and integrity of the fixation construct to achieve union. The biomechanics that dictate fracture site stability and implant stress depend on fracture type as well as implant features such as nail length, nail diameter, presence of distal fixation screws, and material composition of the implant. When deciding how to fix a fracture, surgeons have choices in these implant‐related design variables. This study models all combinations of a range of implant variables for nine standard AO/OTA proximal femur fractures using finite element analysis. Under simulated maximum load during gait, the maximum stress in the implant and screws as well as interfragmentary motions at the fracture site in the axial and shear directions were computed. The results were separated by fracture type to show the influence of each design variable on measured biomechanical outcomes. Filling the reamed canal with the largest fitting nail diameter reduced axial and shear interfragmentary motion for all fracture types. Nail length was less predictive of shear interfragmentary motion for most simulated fracture types than other construct variables. Furthermore, gapping at the fracture site predisposed the construct to higher implant stresses and larger interfragmentary motions. Clinical significance: Biomechanical outcomes from this computational study can aid in surgical decision‐making for optimizing hip fracture fixation with IM nailing. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:2358–2366, 2019
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Undefined-3
ISSN:0736-0266
1554-527X
DOI:10.1002/jor.24401