APEX protocol implementation on a lab-on-a-chip for SNPs detection

In this work a detection module for the single nucleotide polymorphisms (SNPs) detection was realised. In particular arrayed primer extension (APEX) was selected as innovative method for SNPs detection and this protocol was scaled down following a micro total analysis approach in order to fabricate...

Full description

Saved in:
Bibliographic Details
Published inMicroelectronic engineering Vol. 85; no. 5-6; pp. 1326 - 1329
Main Authors Marasso, S.L., Canavese, G., Cocuzza, M., Ferrarini, A., Giuri, E., Lo Bartolo, S., Mantero, G., Perrone, D., Quaglio, M., Vallini, I.
Format Journal Article Conference Proceeding
LanguageEnglish
Published Amsterdam Elsevier B.V 01.05.2008
Elsevier Science
Subjects
Online AccessGet full text

Cover

Loading…
Abstract In this work a detection module for the single nucleotide polymorphisms (SNPs) detection was realised. In particular arrayed primer extension (APEX) was selected as innovative method for SNPs detection and this protocol was scaled down following a micro total analysis approach in order to fabricate a lab-on-a-chip (LOC). Finite element analysis and behavioural simulations with commercial tools to properly design the microfluidic circuitry have preceded the technological processes for the production of the device. The fluidic was designed to contain 5μl of DNA and reagents that are inserted through three inlets. The layout includes two mixers and a sealed reaction chamber. Glass/silicon prototypes were fabricated with the employment of micro-electro-mechanical-system (MEMS) processes. The devices were tested with APEX biological protocols customized for the scaled volumes. Furthermore, in order to demonstrate the absence of any negative interaction between the chip and the APEX reagents, different chips were tested in intermediate steps together with the protocol executed in standard conditions. The final result demonstrates that the thermo sequenase extended the probes with the dideoxynucleotides modified with Cy5 fluorophore, thus indicating the possibility of implementation of the APEX protocol on LOC devices.
AbstractList In this work a detection module for the single nucleotide polymorphisms (SNPs) detection was realised. In particular arrayed primer extension (APEX) was selected as innovative method for SNPs detection and this protocol was scaled down following a micro total analysis approach in order to fabricate a lab-on-a-chip (LOC). Finite element analysis and behavioural simulations with commercial tools to properly design the microfluidic circuitry have preceded the technological processes for the production of the device. The fluidic was designed to contain 5μl of DNA and reagents that are inserted through three inlets. The layout includes two mixers and a sealed reaction chamber. Glass/silicon prototypes were fabricated with the employment of micro-electro-mechanical-system (MEMS) processes. The devices were tested with APEX biological protocols customized for the scaled volumes. Furthermore, in order to demonstrate the absence of any negative interaction between the chip and the APEX reagents, different chips were tested in intermediate steps together with the protocol executed in standard conditions. The final result demonstrates that the thermo sequenase extended the probes with the dideoxynucleotides modified with Cy5 fluorophore, thus indicating the possibility of implementation of the APEX protocol on LOC devices.
In this work a detection module for the single nucleotide polymorphisms (SNPs) detection was realised. In particular arrayed primer extension (APEX) was selected as innovative method for SNPs detection and this protocol was scaled down following a micro total analysis approach in order to fabricate a lab-on-a-chip (LOC). Finite element analysis and behavioural simulations with commercial tools to properly design the microfluidic circuitry have preceded the technological processes for the production of the device. The fluidic was designed to contain 5 mul of DNA and reagents that are inserted through three inlets. The layout includes two mixers and a sealed reaction chamber. Glass/silicon prototypes were fabricated with the employment of micro-electro-mechanical-system (MEMS) processes. The devices were tested with APEX biological protocols customized for the scaled volumes. Furthermore, in order to demonstrate the absence of any negative interaction between the chip and the APEX reagents, different chips were tested in intermediate steps together with the protocol executed in standard conditions. The final result demonstrates that the thermo sequenase extended the probes with the dideoxynucleotides modified with Cy5 fluorophore, thus indicating the possibility of implementation of the APEX protocol on LOC devices.
Author Perrone, D.
Giuri, E.
Lo Bartolo, S.
Marasso, S.L.
Vallini, I.
Ferrarini, A.
Canavese, G.
Cocuzza, M.
Mantero, G.
Quaglio, M.
Author_xml – sequence: 1
  givenname: S.L.
  surname: Marasso
  fullname: Marasso, S.L.
  email: simone.marasso@polito.it
  organization: χlab – Materials and Microsystems Laboratory, Polytechnic of Turin – Latemar Unit, Chivasso (Turin) 10034, Italy
– sequence: 2
  givenname: G.
  surname: Canavese
  fullname: Canavese, G.
  organization: χlab – Materials and Microsystems Laboratory, Polytechnic of Turin – Latemar Unit, Chivasso (Turin) 10034, Italy
– sequence: 3
  givenname: M.
  surname: Cocuzza
  fullname: Cocuzza, M.
  organization: χlab – Materials and Microsystems Laboratory, Polytechnic of Turin – Latemar Unit, Chivasso (Turin) 10034, Italy
– sequence: 4
  givenname: A.
  surname: Ferrarini
  fullname: Ferrarini, A.
  organization: Dipartimento Scientifico e Tecnologico, Università di Verona – Latemar Unit, Verona 37134, Italy
– sequence: 5
  givenname: E.
  surname: Giuri
  fullname: Giuri, E.
  organization: χlab – Materials and Microsystems Laboratory, Polytechnic of Turin – Latemar Unit, Chivasso (Turin) 10034, Italy
– sequence: 6
  givenname: S.
  surname: Lo Bartolo
  fullname: Lo Bartolo, S.
  organization: Biodiversity S.p.A. – Latemar Unit, Brescia 25124, Italy
– sequence: 7
  givenname: G.
  surname: Mantero
  fullname: Mantero, G.
  organization: Biodiversity S.p.A. – Latemar Unit, Brescia 25124, Italy
– sequence: 8
  givenname: D.
  surname: Perrone
  fullname: Perrone, D.
  organization: χlab – Materials and Microsystems Laboratory, Polytechnic of Turin – Latemar Unit, Chivasso (Turin) 10034, Italy
– sequence: 9
  givenname: M.
  surname: Quaglio
  fullname: Quaglio, M.
  organization: χlab – Materials and Microsystems Laboratory, Polytechnic of Turin – Latemar Unit, Chivasso (Turin) 10034, Italy
– sequence: 10
  givenname: I.
  surname: Vallini
  fullname: Vallini, I.
  organization: Biodiversity S.p.A. – Latemar Unit, Brescia 25124, Italy
BackLink http://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=20492351$$DView record in Pascal Francis
BookMark eNp9kE1LAzEQhoNUsK3-AG970duu-WxSPNVSP6BoQQVvIU0nmLK7qclW8N-bpcWjEBgCz7wz84zQoA0tIHRJcEUwmdxsqwagohjLitAKU36ChkRJVgoxUQM0zIwsp4zIMzRKaYvzn2M1RHez1eKj2MXQBRvqwje7GhpoO9P50Bb5maI26zK0pSntp98VLsTi9XmVig10YHvqHJ06Uye4ONYxer9fvM0fy-XLw9N8tiwtE6orAQtCrbC5Gm6UEoLT6cYxuiZSMWGMosJJITmWbi2FVQos5sAFOOME52yMrg-5eduvPaRONz5ZqGvTQtgnzZiQciJJBskBtDGkFMHpXfSNiT-aYN3b0ludbeneliZUZ1u55-oYbpI1tYumtT79NVLMp5SJPvv2wEG-9NtD1Ml6aC1sfMw69Cb4f6b8Ao4yf0s
CODEN MIENEF
CitedBy_id crossref_primary_10_3390_s8096077
crossref_primary_10_3390_w15061222
crossref_primary_10_1007_s10544_010_9467_5
crossref_primary_10_1007_s10544_014_9869_x
crossref_primary_10_1109_TED_2017_2732733
crossref_primary_10_1088_2058_8585_ab4dce
crossref_primary_10_1007_s00216_009_2826_5
crossref_primary_10_1116_1_5003203
crossref_primary_10_1002_elps_200900305
Cites_doi 10.1088/0960-1317/16/12/022
10.1101/gr.1.1.17
10.1021/ac0352629
10.1016/S1525-1578(10)60567-3
10.1542/peds.2005-2519
10.1089/gte.2005.9.212
10.1093/clinchem/48.11.2051
10.1109/JMEMS.2004.839334
ContentType Journal Article
Conference Proceeding
Copyright 2007 Elsevier B.V.
2008 INIST-CNRS
Copyright_xml – notice: 2007 Elsevier B.V.
– notice: 2008 INIST-CNRS
DBID IQODW
AAYXX
CITATION
7SP
8FD
L7M
DOI 10.1016/j.mee.2007.12.024
DatabaseName Pascal-Francis
CrossRef
Electronics & Communications Abstracts
Technology Research Database
Advanced Technologies Database with Aerospace
DatabaseTitle CrossRef
Technology Research Database
Advanced Technologies Database with Aerospace
Electronics & Communications Abstracts
DatabaseTitleList
Technology Research Database
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
Applied Sciences
Physics
EISSN 1873-5568
EndPage 1329
ExternalDocumentID 10_1016_j_mee_2007_12_024
20492351
S0167931707007721
GroupedDBID --K
--M
.~1
0R~
123
1B1
1RT
1~.
1~5
29M
4.4
457
4G.
5VS
7-5
71M
8P~
9JN
AABNK
AABXZ
AACTN
AAEDT
AAEDW
AAEPC
AAIAV
AAIKJ
AAKOC
AALRI
AAOAW
AAQFI
AAQXK
AAXUO
AAYFN
ABBOA
ABFNM
ABFRF
ABJNI
ABMAC
ABNEU
ABXDB
ABXRA
ABYKQ
ACDAQ
ACFVG
ACGFO
ACGFS
ACNNM
ACRLP
ACZNC
ADBBV
ADEZE
ADJOM
ADMUD
ADTZH
AEBSH
AECPX
AEFWE
AEKER
AENEX
AEZYN
AFFNX
AFKWA
AFRZQ
AFTJW
AGHFR
AGUBO
AGYEJ
AHHHB
AHJVU
AHZHX
AIALX
AIEXJ
AIKHN
AITUG
AIVDX
AJBFU
AJOXV
ALMA_UNASSIGNED_HOLDINGS
AMFUW
AMRAJ
AOUOD
ASPBG
AVWKF
AXJTR
AZFZN
BBWZM
BJAXD
BKOJK
BLXMC
CS3
DU5
EBS
EFJIC
EFLBG
EJD
EO8
EO9
EP2
EP3
F0J
FDB
FEDTE
FGOYB
FIRID
FNPLU
FYGXN
G-2
G-Q
G8K
GBLVA
GBOLZ
HLZ
HMV
HVGLF
HX~
HZ~
IHE
J1W
JJJVA
KOM
LG9
LY7
M24
M38
M41
MAGPM
MO0
N9A
NDZJH
O-L
O9-
OAUVE
OGIMB
OZT
P-8
P-9
P2P
PC.
Q38
R2-
RIG
RNS
ROL
RPZ
SBC
SDF
SDG
SDP
SES
SET
SEW
SMS
SPC
SPCBC
SPD
SPG
SSM
SSQ
SST
SSV
SSZ
T5K
UHS
WUQ
XFK
ZMT
~G-
AAPBV
ABPIF
ABPTK
IQODW
AAXKI
AAYXX
AFJKZ
AKRWK
CITATION
7SP
8FD
L7M
ID FETCH-LOGICAL-c358t-e0512c5ce05a4a8855429df32b17835aa825f757407fb75c88ec04e45efaf5443
IEDL.DBID .~1
ISSN 0167-9317
IngestDate Fri Oct 25 04:37:01 EDT 2024
Thu Sep 26 16:10:05 EDT 2024
Sun Oct 29 17:09:13 EDT 2023
Fri Feb 23 02:22:36 EST 2024
IsPeerReviewed true
IsScholarly true
Issue 5-6
Keywords Lab-on-a-chip
Silicon
SNP
Detection
APEX
DNA
Fluid mechanics
Prototype
Mixer
Numerical method
System on a chip
Micromachine
Implementation
Finite element method
Integrated circuit testing
Behavioral analysis
Integrated circuit
Miniaturization
Microelectromechanical device
Microfluidics
Language English
License CC BY 4.0
LinkModel DirectLink
MeetingName International Conference on Micro- and Nano-Engineering (MNE) held in Copenhagen, Denmark, September 23-26, 2007
MergedId FETCHMERGED-LOGICAL-c358t-e0512c5ce05a4a8855429df32b17835aa825f757407fb75c88ec04e45efaf5443
Notes SourceType-Scholarly Journals-2
ObjectType-Feature-2
ObjectType-Conference Paper-1
content type line 23
SourceType-Conference Papers & Proceedings-1
ObjectType-Article-3
PQID 33577671
PQPubID 23500
PageCount 4
ParticipantIDs proquest_miscellaneous_33577671
crossref_primary_10_1016_j_mee_2007_12_024
pascalfrancis_primary_20492351
elsevier_sciencedirect_doi_10_1016_j_mee_2007_12_024
PublicationCentury 2000
PublicationDate 2008-05-01
PublicationDateYYYYMMDD 2008-05-01
PublicationDate_xml – month: 05
  year: 2008
  text: 2008-05-01
  day: 01
PublicationDecade 2000
PublicationPlace Amsterdam
PublicationPlace_xml – name: Amsterdam
PublicationTitle Microelectronic engineering
PublicationYear 2008
Publisher Elsevier B.V
Elsevier Science
Publisher_xml – name: Elsevier B.V
– name: Elsevier Science
References Lu (bib5) 2005; 9
Schrijver, Oitmaa, Metspalu, Gardner (bib6) 2005; 7
Eckert, Kundel (bib2) 1991; 1
Gardner (bib4) 2006; 118
Gemignani (bib1) 2002; 48
Pirri (bib3) 2004; 76
Xia (bib7) 2006; 16
Satyanarayana, Karnik, Majumdar (bib8) 2005; 14
Satyanarayana (10.1016/j.mee.2007.12.024_bib8) 2005; 14
Pirri (10.1016/j.mee.2007.12.024_bib3) 2004; 76
Lu (10.1016/j.mee.2007.12.024_bib5) 2005; 9
Xia (10.1016/j.mee.2007.12.024_bib7) 2006; 16
Gemignani (10.1016/j.mee.2007.12.024_bib1) 2002; 48
Schrijver (10.1016/j.mee.2007.12.024_bib6) 2005; 7
Gardner (10.1016/j.mee.2007.12.024_bib4) 2006; 118
Eckert (10.1016/j.mee.2007.12.024_bib2) 1991; 1
References_xml – volume: 7
  start-page: 375
  year: 2005
  ident: bib6
  publication-title: J. Mol. Diagn.
  contributor:
    fullname: Gardner
– volume: 1
  start-page: 17
  year: 1991
  ident: bib2
  publication-title: PCR Meth. Appl.
  contributor:
    fullname: Kundel
– volume: 14
  start-page: 392
  year: 2005
  ident: bib8
  publication-title: J. Microelectromech. Syst.
  contributor:
    fullname: Majumdar
– volume: 9
  start-page: 212
  year: 2005
  ident: bib5
  publication-title: Genet Test
  contributor:
    fullname: Lu
– volume: 76
  start-page: 1352
  year: 2004
  ident: bib3
  publication-title: Anal. Chem.
  contributor:
    fullname: Pirri
– volume: 118
  start-page: 985
  year: 2006
  ident: bib4
  publication-title: Pediatrics
  contributor:
    fullname: Gardner
– volume: 48
  start-page: 2051
  year: 2002
  ident: bib1
  publication-title: Clin. Chem.
  contributor:
    fullname: Gemignani
– volume: 16
  start-page: 2684
  year: 2006
  ident: bib7
  publication-title: J. Micromech. Microeng.
  contributor:
    fullname: Xia
– volume: 16
  start-page: 2684
  year: 2006
  ident: 10.1016/j.mee.2007.12.024_bib7
  publication-title: J. Micromech. Microeng.
  doi: 10.1088/0960-1317/16/12/022
  contributor:
    fullname: Xia
– volume: 1
  start-page: 17
  issue: 1
  year: 1991
  ident: 10.1016/j.mee.2007.12.024_bib2
  publication-title: PCR Meth. Appl.
  doi: 10.1101/gr.1.1.17
  contributor:
    fullname: Eckert
– volume: 76
  start-page: 1352
  issue: 5
  year: 2004
  ident: 10.1016/j.mee.2007.12.024_bib3
  publication-title: Anal. Chem.
  doi: 10.1021/ac0352629
  contributor:
    fullname: Pirri
– volume: 7
  start-page: 375
  issue: 3
  year: 2005
  ident: 10.1016/j.mee.2007.12.024_bib6
  publication-title: J. Mol. Diagn.
  doi: 10.1016/S1525-1578(10)60567-3
  contributor:
    fullname: Schrijver
– volume: 118
  start-page: 985
  issue: 3
  year: 2006
  ident: 10.1016/j.mee.2007.12.024_bib4
  publication-title: Pediatrics
  doi: 10.1542/peds.2005-2519
  contributor:
    fullname: Gardner
– volume: 9
  start-page: 212
  issue: 3
  year: 2005
  ident: 10.1016/j.mee.2007.12.024_bib5
  publication-title: Genet Test
  doi: 10.1089/gte.2005.9.212
  contributor:
    fullname: Lu
– volume: 48
  start-page: 2051
  issue: 11
  year: 2002
  ident: 10.1016/j.mee.2007.12.024_bib1
  publication-title: Clin. Chem.
  doi: 10.1093/clinchem/48.11.2051
  contributor:
    fullname: Gemignani
– volume: 14
  start-page: 392
  issue: 2
  year: 2005
  ident: 10.1016/j.mee.2007.12.024_bib8
  publication-title: J. Microelectromech. Syst.
  doi: 10.1109/JMEMS.2004.839334
  contributor:
    fullname: Satyanarayana
SSID ssj0016408
Score 1.9401977
Snippet In this work a detection module for the single nucleotide polymorphisms (SNPs) detection was realised. In particular arrayed primer extension (APEX) was...
SourceID proquest
crossref
pascalfrancis
elsevier
SourceType Aggregation Database
Index Database
Publisher
StartPage 1326
SubjectTerms APEX
Applied fluid mechanics
Applied sciences
Circuit properties
Design. Technologies. Operation analysis. Testing
Detection
DNA
Electric, optical and optoelectronic circuits
Electronic circuits
Electronics
Exact sciences and technology
Fluid dynamics
Fluidics
Fundamental areas of phenomenology (including applications)
Integrated circuits
Lab-on-a-chip
Micro- and nanoelectromechanical devices (mems/nems)
Physics
Semiconductor electronics. Microelectronics. Optoelectronics. Solid state devices
Signal convertors
Silicon
SNP
Title APEX protocol implementation on a lab-on-a-chip for SNPs detection
URI https://dx.doi.org/10.1016/j.mee.2007.12.024
https://search.proquest.com/docview/33577671
Volume 85
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1bS8MwFA5jvigiXnFeZh58EuJ6SdrucY6NqTgGc7C3kKYJTlhbXPfqb_ckbYdD9EEoBEpLy3eSk3OSL99B6DZxdCSohtwEolUC8a0igqmYOEzJUCXS9Zk5jfwyDkYz-jRn8wbq12dhDK2y8v2lT7feurrTqdDs5ItFZ2oI9F2Y_qDTOhAj2hPszA7O-88NzQOyAVuVzup7m6frnU3L8VoqVaoYmhVBj_42N-3nYgWI6bLUxQ-vbaei4SE6qGJI3Ct_8wg1VHqM9r4pC56gh95kMMdGhCEDS-PFsqaJGztguAQG85MsJYLIt0WOIXbF0_FkhRNVWHZWeopmw8Frf0SqcglE-iwqiILx5UkmoRVURIZ_5nUT7Xuxa5Z3hIBkUIcshBROxyGTUaSkQxVlSgttZPDOUDPNUnWOsBHJYxIiC4cllIYyZsIPoiCGNgh91m2huxoonpeqGLymi71zQNVUtwy563FAtYVoDSXfMi0Hr_3Xa-0t2Dcf8hwjKsfcFrqp7cBhTJiNDpGqbL3ivs-MSJF78b8vX6LdkhViaI1XqFl8rNU1hB5F3LZ9q412eo_Po_EXTBzV5Q
link.rule.ids 310,311,315,783,787,792,793,4511,23944,23945,24130,25154,27938,27939,45599,45693
linkProvider Elsevier
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1JawIxFA5SD20ppSu1i-bQUyE4SzLL0YqidUFQwVvIZBJqwVHq-P_7MotUSnsoDAQGQob3Xl6-TL58D6Hn2NKBoBr2JoBWCeBbRQRTEbGYkr6Kpe0ycxt5NPZ6c_q2YIsKapd3YQytssj9eU7PsnXxpllYs7lZLptTQ6APYfmDoLUAI8IWqApoIIRgr7b6g954f5jg0awwXSbxbTqUh5sZzWulVC5kaH4KOvS35elsI7ZgNJ1Xu_iRuLPVqHuBzgsYiVv5l16iikqu0Ok3ccFr9NqadBbY6DCswdl4uSqZ4sYVGB6BIQLIOiGCyPflBgN8xdPxZItjlWYEreQGzbudWbtHiooJRLosSImCKeZIJqEVVASGguaEsXadyDZ_eISA_aD2mQ-7OB35TAaBkhZVlCkttFHCu0VHyTpRdwgbnTwmAVxYLKbUlxETrhd4EbSe77Kwhl5KQ_FNLozBS8bYBwermgKXPrcdDlatIVqakh94l0Pi_qtb_cDs-4Ecy-jKMbuGGqUfOEwLc9YhErXebbnrMqNTZN__b-QGOu7NRkM-7I8HD-gkJ4kYluMjOko_d-oJkEga1YtI-wLTMNii
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=proceeding&rft.title=Microelectronic+engineering&rft.atitle=APEX+protocol+implementation+on+a+lab-on-a-chip+for+SNPs+detection&rft.au=MARASSO%2C+S.+L&rft.au=CANAVESE%2C+G&rft.au=COCUZZA%2C+M&rft.au=FERRARINI%2C+A&rft.date=2008-05-01&rft.pub=Elsevier+Science&rft.issn=0167-9317&rft.eissn=1873-5568&rft.volume=85&rft.issue=5-6&rft.spage=1326&rft.epage=1329&rft_id=info:doi/10.1016%2Fj.mee.2007.12.024&rft.externalDBID=n%2Fa&rft.externalDocID=20492351
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0167-9317&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0167-9317&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0167-9317&client=summon