Dispersive Aortic Cannulas Reduce Aortic Wall Shear Stress Affecting Atherosclerotic Plaque Embolization

Neurologic complications during on‐pump cardiovascular surgery are often induced by mobilization of atherosclerotic plaques, which is directly related to enhanced wall shear stress. In the present study, we numerically evaluated the impact of dispersive aortic cannulas on aortic blood flow character...

Full description

Saved in:
Bibliographic Details
Published inArtificial organs Vol. 39; no. 3; pp. 203 - 211
Main Authors Assmann, Alexander, Gül, Fethi, Benim, Ali Cemal, Joos, Franz, Akhyari, Payam, Lichtenberg, Artur
Format Journal Article
LanguageEnglish
Published United States Blackwell Publishing Ltd 01.03.2015
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Neurologic complications during on‐pump cardiovascular surgery are often induced by mobilization of atherosclerotic plaques, which is directly related to enhanced wall shear stress. In the present study, we numerically evaluated the impact of dispersive aortic cannulas on aortic blood flow characteristics, with special regard to the resulting wall shear stress profiles. An idealized numerical model of the human aorta and its branches was created and used to model straight as well as bent dispersive aortic cannulas with meshlike tips inserted in the distal ascending aorta. Standard cannulas with straight beveled or bent tips served as controls. Using a recently optimized computing method, simulations of pulsatile and nonpulsatile extracorporeal circulation were performed. Dispersive aortic cannulas reduced the maximum and average aortic wall shear stress values to approximately 50% of those with control cannulas, while the difference in local values was even larger. Moreover, under pulsatile circulation, dispersive cannulas shortened the time period during which wall shear stress values were increased. The turbulent kinetic energy was also diminished by utilizing dispersive cannulas, reducing the risk of hemolysis. In summary, dispersive aortic cannulas decrease aortic wall shear stress and turbulence during extracorporeal circulation and may therefore reduce the risk of endothelial and blood cell damage as well as that of neurologic complications caused by atherosclerotic plaque mobilization.
Bibliography:ArticleID:AOR12359
istex:2E2E5B097EB3A73CCDD16E68F001008AA18396E3
Sorin Group (Milan, Italy)
ark:/67375/WNG-NB9C59HF-C
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0160-564X
1525-1594