Analysis of Intrasession Repeatability of Ocular Aberrometric Measurements and Validation of Keratometry Provided by a New Integrated System in Mild to Moderate Keratoconus
To evaluate the intrasession repeatability and validity of corneal curvature measurements provided by a new multifunctional device and to assess the intrasession repeatability of its ocular aberrometric measures. This prospective study comprises 37 mild to moderate keratoconus eyes of 37 patients. I...
Saved in:
Published in | Cornea Vol. 38; no. 9; p. 1097 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
United States
01.09.2019
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Abstract | To evaluate the intrasession repeatability and validity of corneal curvature measurements provided by a new multifunctional device and to assess the intrasession repeatability of its ocular aberrometric measures.
This prospective study comprises 37 mild to moderate keratoconus eyes of 37 patients. In all cases, 3 repeated measures of corneal topography and ocular aberrometry were performed with the iDesign 2 system (iD2; Johnson & Johnson Vision Care Inc, Jacksonville, FL) and one keratometric measurement was performed with the intraocular lens-(IOL) Master 500 (Carl Zeiss Meditec Inc, Dublin, CA) and Sirius (CSO) (SIR) systems.
The within-subject SD (Sw) was <0.50 D for all iD2 keratometric measurements, with intraclass correlation coefficient (ICC) >0.980. Sw and ICC for the keratometric axis were 2.60 degrees and 0.992, respectively. Concerning aberrations, all Sw values for high-order Zernike terms were ≤0.11 μm (ICC > 0.900), and all Sw values for refraction data were <0.75 D (ICC > 0.95), except for J45. No statistically significant differences were found between the devices in any keratometric parameter evaluated (P ≥ 0.222), but the limits of agreement between the devices were clinically relevant. The magnitude of K readings and astigmatism correlated significantly with the difference in these parameters between iD2 and SIR (0.432 ≤ r ≤ 0.489, P ≤ 0.041).
The iD2 system provides consistent measures of keratometry and ocular aberrometry in eyes with mild to moderate keratoconus. Keratometric data obtained with this system in these eyes cannot be considered as interchangeable with data provided by intraocular lens-Master 500 and SIR. |
---|---|
AbstractList | To evaluate the intrasession repeatability and validity of corneal curvature measurements provided by a new multifunctional device and to assess the intrasession repeatability of its ocular aberrometric measures.
This prospective study comprises 37 mild to moderate keratoconus eyes of 37 patients. In all cases, 3 repeated measures of corneal topography and ocular aberrometry were performed with the iDesign 2 system (iD2; Johnson & Johnson Vision Care Inc, Jacksonville, FL) and one keratometric measurement was performed with the intraocular lens-(IOL) Master 500 (Carl Zeiss Meditec Inc, Dublin, CA) and Sirius (CSO) (SIR) systems.
The within-subject SD (Sw) was <0.50 D for all iD2 keratometric measurements, with intraclass correlation coefficient (ICC) >0.980. Sw and ICC for the keratometric axis were 2.60 degrees and 0.992, respectively. Concerning aberrations, all Sw values for high-order Zernike terms were ≤0.11 μm (ICC > 0.900), and all Sw values for refraction data were <0.75 D (ICC > 0.95), except for J45. No statistically significant differences were found between the devices in any keratometric parameter evaluated (P ≥ 0.222), but the limits of agreement between the devices were clinically relevant. The magnitude of K readings and astigmatism correlated significantly with the difference in these parameters between iD2 and SIR (0.432 ≤ r ≤ 0.489, P ≤ 0.041).
The iD2 system provides consistent measures of keratometry and ocular aberrometry in eyes with mild to moderate keratoconus. Keratometric data obtained with this system in these eyes cannot be considered as interchangeable with data provided by intraocular lens-Master 500 and SIR. |
Author | Piñero, David P Ruiz-Fortes, Pedro Soto-Negro, Roberto Pérez-Cambrodí, Rafael J Fukumitsu, Hideki |
Author_xml | – sequence: 1 givenname: David P surname: Piñero fullname: Piñero, David P organization: Department of Ophthalmology (OFTALMAR), Vithas Medimar International Hospital, Alicante, Spain – sequence: 2 givenname: Roberto surname: Soto-Negro fullname: Soto-Negro, Roberto organization: Department of Ophthalmology (OFTALMAR), Vithas Medimar International Hospital, Alicante, Spain – sequence: 3 givenname: Pedro surname: Ruiz-Fortes fullname: Ruiz-Fortes, Pedro organization: Department of Ophthalmology (OFTALMAR), Vithas Medimar International Hospital, Alicante, Spain – sequence: 4 givenname: Rafael J surname: Pérez-Cambrodí fullname: Pérez-Cambrodí, Rafael J organization: Department of Ophthalmology (OFTALMAR), Vithas Medimar International Hospital, Alicante, Spain – sequence: 5 givenname: Hideki surname: Fukumitsu fullname: Fukumitsu, Hideki organization: Department of Ophthalmology, Marina Baixa Hospital, Villajoyosa, Alicante, Spain |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/31246681$$D View this record in MEDLINE/PubMed |
BookMark | eNpNkNtKAzEQhoMo1lbfQCQv0LqnJLuXpXgotlY83ZZJMiuR3WxJssq-kw_prlZwbgb-wzcwY3JoG4uEnMfRLI4KcblcbGbRv0miNDsgJzFL-TQTRT4iY-_fe0MInhyTURonGed5fEK-5haqzhtPm5IubXDg0XvTWPqIO4QA0lQmdIO7UW0Fjs4lOtfUGJxRdI3gW4c12uApWE1foTIawgDoK3foIPxkO_rgmg-jUVPZUaD3-Dmcw7c-0GtPnQ9YU2Pp2lSahoauGz2Ucc9QjW39KTkqofJ4tt8T8nJ99by4na42N8vFfDVVKePZVGYFVykCY7mAsmC5VDkrIE3KSDDEMmIZz7QquIZM6CQty1iiypWQvcxkmUzIxS9318oa9XbnTA2u2_69LfkGu2N0vQ |
CitedBy_id | crossref_primary_10_1097_j_jcrs_0000000000000359 crossref_primary_10_1007_s00417_023_06348_y crossref_primary_10_1080_02713683_2020_1822418 crossref_primary_10_18502_jovr_v18i4_14551 crossref_primary_10_1097_ICL_0000000000000787 crossref_primary_10_2174_1874364102014010059 crossref_primary_10_1111_cxo_13002 crossref_primary_10_3390_polym14235321 |
ContentType | Journal Article |
DBID | CGR CUY CVF ECM EIF NPM |
DOI | 10.1097/ICO.0000000000002034 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1536-4798 |
ExternalDocumentID | 31246681 |
Genre | Validation Studies Journal Article |
GroupedDBID | --- .-D .3C .GJ .Z2 01R 0R~ 1J1 40H 4Q1 4Q2 4Q3 53G 5GY 5RE 5VS 71W 77Y 7O~ 8L- AAAAV AAAXR AAGIX AAHPQ AAIQE AAMOA AAMTA AAQKA AAQQT AARTV AASCR AASOK AAUEB AAXQO AAYEP ABASU ABBUW ABDIG ABJNI ABVCZ ABXRP ABXVJ ABZAD ABZZY ACCJW ACDDN ACDOF ACEWG ACGFO ACGFS ACIJW ACILI ACLDA ACNCT ACNWC ACWDW ACWRI ACXJB ACXNZ ACZKN ADFPA ADGGA ADHPY ADNKB AE3 AE6 AEETU AENEX AFBFQ AFDTB AFMBP AFSOK AFUWQ AGINI AHOMT AHQNM AHRYX AHVBC AIJEX AINUH AJCLO AJIOK AJNWD AJNYG AJZMW AKCTQ AKULP ALKUP ALMA_UNASSIGNED_HOLDINGS ALMTX AMJPA AMKUR AMNEI AOHHW AOQMC BOYCO BQLVK BS7 C45 CGR CS3 CUY CVF DIWNM DU5 DUNZO E.X EBS ECM EEVPB EIF EJD ERAAH EX3 F2K F2L F2M F2N F5P FCALG FL- FW0 GNXGY GQDEL H0~ HLJTE HZ~ IKREB IKYAY IN~ IPNFZ JF9 JG8 JK3 JK8 K8S KD2 KMI L-C N9A NPM N~7 N~B N~M O9- OAG OAH OCUKA ODA OL1 OLG OLH OLU OLV OLY OLZ OPUJH ORVUJ OUVQU OVD OVDNE OVIDH OVLEI OVOZU OWU OWV OWW OWX OWY OWZ OXXIT P-K P2P R58 RIG RLZ S4R S4S T8P TEORI TSPGW V2I VVN W3M WOQ WOW X3V X3W XXN XYM YFH ZB8 ZFV ZGI ZZMQN |
ID | FETCH-LOGICAL-c3564-b496c3ea5587af958bc859a32f075eef05464dc96da47d23ff1bec8c7b64d5bf2 |
IngestDate | Thu Apr 03 07:09:41 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 9 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c3564-b496c3ea5587af958bc859a32f075eef05464dc96da47d23ff1bec8c7b64d5bf2 |
PMID | 31246681 |
ParticipantIDs | pubmed_primary_31246681 |
PublicationCentury | 2000 |
PublicationDate | 2019-Sep |
PublicationDateYYYYMMDD | 2019-09-01 |
PublicationDate_xml | – month: 09 year: 2019 text: 2019-Sep |
PublicationDecade | 2010 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Cornea |
PublicationTitleAlternate | Cornea |
PublicationYear | 2019 |
SSID | ssj0007762 |
Score | 2.3408356 |
Snippet | To evaluate the intrasession repeatability and validity of corneal curvature measurements provided by a new multifunctional device and to assess the... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 1097 |
SubjectTerms | Aberrometry - instrumentation Aberrometry - standards Adolescent Adult Aged Corneal Topography - instrumentation Corneal Topography - standards Female Humans Keratoconus - diagnosis Male Middle Aged Prospective Studies Reproducibility of Results Young Adult |
Title | Analysis of Intrasession Repeatability of Ocular Aberrometric Measurements and Validation of Keratometry Provided by a New Integrated System in Mild to Moderate Keratoconus |
URI | https://www.ncbi.nlm.nih.gov/pubmed/31246681 |
Volume | 38 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LbxMxELZSkKpeEO83mgM3ZMg-vT6WQtWA0laiRb1V9tqWIpXdKqQH8pv4X_wNxq9dUwUE5LCKPLveKPNpPDOe-UzIS82rBo2gpjmTmlr-EiozbaiuSsYFbw1Xrsr3sD44LT-cVWeTyY-kaulqJV-36419Jf-jVRxDvdou2X_Q7DApDuB31C9eUcN4_Ssdp4wiM5ul_epZNqxbjTbWU3C7LfQjX266K_XS8hNYWv5X8zE96ImaP6NPrgYX8qOlW3b32iZC16_nnFXhaiJnkWZCBdJzmziZLy6UdWbdAWsoC3NgyB3SC5ESoV92elgPjhd2t_5tpn3LjauyH9vOPvWrnh7iu_qxELwftomuFmu6b-uF_XkDWi0H2bGvAVjqNXWNab1yA-_cNMIIfRG2xELOIxuLunDJina6tknBJjXkRZMAlidW2e6yb1wuPA3xbO_I01iGTz71-dUEQZdfHIQK9Ibq2p8x82fpNRLvKNoiWxjO2PNZbVIpOAwMF6TY1cnZm00_Z4dsxymuxT_ODzq5TW6FAAZ2PRrvkInu7pLteSjRuEe-R1BCbyAFJfwCSiv1oIQUlJCCEhCUMILSPpKAEiIoQX4DAQhKGEEJHpSw6MCCElY9RFBCAsr75HT__cneAQ1HgtC2qOqSypLXbaFFVTVMGLQzsm0qLorcoOurtcEApC5Vy2slSqbywpgMjVTTMonDlTT5A3Kj6zv9iMBUo_PWcIYhQ1Y2gmGooVkutGkllyqfPiYP_f98ful5X86jBp78VvKU7IxwfUZuGjQ0-jl6rSv5wun8J7Zom1k |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Analysis+of+Intrasession+Repeatability+of+Ocular+Aberrometric+Measurements+and+Validation+of+Keratometry+Provided+by+a+New+Integrated+System+in+Mild+to+Moderate+Keratoconus&rft.jtitle=Cornea&rft.au=Pi%C3%B1ero%2C+David+P&rft.au=Soto-Negro%2C+Roberto&rft.au=Ruiz-Fortes%2C+Pedro&rft.au=P%C3%A9rez-Cambrod%C3%AD%2C+Rafael+J&rft.date=2019-09-01&rft.eissn=1536-4798&rft.volume=38&rft.issue=9&rft.spage=1097&rft_id=info:doi/10.1097%2FICO.0000000000002034&rft_id=info%3Apmid%2F31246681&rft_id=info%3Apmid%2F31246681&rft.externalDocID=31246681 |