Analysis of Intrasession Repeatability of Ocular Aberrometric Measurements and Validation of Keratometry Provided by a New Integrated System in Mild to Moderate Keratoconus

To evaluate the intrasession repeatability and validity of corneal curvature measurements provided by a new multifunctional device and to assess the intrasession repeatability of its ocular aberrometric measures. This prospective study comprises 37 mild to moderate keratoconus eyes of 37 patients. I...

Full description

Saved in:
Bibliographic Details
Published inCornea Vol. 38; no. 9; p. 1097
Main Authors Piñero, David P, Soto-Negro, Roberto, Ruiz-Fortes, Pedro, Pérez-Cambrodí, Rafael J, Fukumitsu, Hideki
Format Journal Article
LanguageEnglish
Published United States 01.09.2019
Subjects
Online AccessGet more information

Cover

Loading…
Abstract To evaluate the intrasession repeatability and validity of corneal curvature measurements provided by a new multifunctional device and to assess the intrasession repeatability of its ocular aberrometric measures. This prospective study comprises 37 mild to moderate keratoconus eyes of 37 patients. In all cases, 3 repeated measures of corneal topography and ocular aberrometry were performed with the iDesign 2 system (iD2; Johnson & Johnson Vision Care Inc, Jacksonville, FL) and one keratometric measurement was performed with the intraocular lens-(IOL) Master 500 (Carl Zeiss Meditec Inc, Dublin, CA) and Sirius (CSO) (SIR) systems. The within-subject SD (Sw) was <0.50 D for all iD2 keratometric measurements, with intraclass correlation coefficient (ICC) >0.980. Sw and ICC for the keratometric axis were 2.60 degrees and 0.992, respectively. Concerning aberrations, all Sw values for high-order Zernike terms were ≤0.11 μm (ICC > 0.900), and all Sw values for refraction data were <0.75 D (ICC > 0.95), except for J45. No statistically significant differences were found between the devices in any keratometric parameter evaluated (P ≥ 0.222), but the limits of agreement between the devices were clinically relevant. The magnitude of K readings and astigmatism correlated significantly with the difference in these parameters between iD2 and SIR (0.432 ≤ r ≤ 0.489, P ≤ 0.041). The iD2 system provides consistent measures of keratometry and ocular aberrometry in eyes with mild to moderate keratoconus. Keratometric data obtained with this system in these eyes cannot be considered as interchangeable with data provided by intraocular lens-Master 500 and SIR.
AbstractList To evaluate the intrasession repeatability and validity of corneal curvature measurements provided by a new multifunctional device and to assess the intrasession repeatability of its ocular aberrometric measures. This prospective study comprises 37 mild to moderate keratoconus eyes of 37 patients. In all cases, 3 repeated measures of corneal topography and ocular aberrometry were performed with the iDesign 2 system (iD2; Johnson & Johnson Vision Care Inc, Jacksonville, FL) and one keratometric measurement was performed with the intraocular lens-(IOL) Master 500 (Carl Zeiss Meditec Inc, Dublin, CA) and Sirius (CSO) (SIR) systems. The within-subject SD (Sw) was <0.50 D for all iD2 keratometric measurements, with intraclass correlation coefficient (ICC) >0.980. Sw and ICC for the keratometric axis were 2.60 degrees and 0.992, respectively. Concerning aberrations, all Sw values for high-order Zernike terms were ≤0.11 μm (ICC > 0.900), and all Sw values for refraction data were <0.75 D (ICC > 0.95), except for J45. No statistically significant differences were found between the devices in any keratometric parameter evaluated (P ≥ 0.222), but the limits of agreement between the devices were clinically relevant. The magnitude of K readings and astigmatism correlated significantly with the difference in these parameters between iD2 and SIR (0.432 ≤ r ≤ 0.489, P ≤ 0.041). The iD2 system provides consistent measures of keratometry and ocular aberrometry in eyes with mild to moderate keratoconus. Keratometric data obtained with this system in these eyes cannot be considered as interchangeable with data provided by intraocular lens-Master 500 and SIR.
Author Piñero, David P
Ruiz-Fortes, Pedro
Soto-Negro, Roberto
Pérez-Cambrodí, Rafael J
Fukumitsu, Hideki
Author_xml – sequence: 1
  givenname: David P
  surname: Piñero
  fullname: Piñero, David P
  organization: Department of Ophthalmology (OFTALMAR), Vithas Medimar International Hospital, Alicante, Spain
– sequence: 2
  givenname: Roberto
  surname: Soto-Negro
  fullname: Soto-Negro, Roberto
  organization: Department of Ophthalmology (OFTALMAR), Vithas Medimar International Hospital, Alicante, Spain
– sequence: 3
  givenname: Pedro
  surname: Ruiz-Fortes
  fullname: Ruiz-Fortes, Pedro
  organization: Department of Ophthalmology (OFTALMAR), Vithas Medimar International Hospital, Alicante, Spain
– sequence: 4
  givenname: Rafael J
  surname: Pérez-Cambrodí
  fullname: Pérez-Cambrodí, Rafael J
  organization: Department of Ophthalmology (OFTALMAR), Vithas Medimar International Hospital, Alicante, Spain
– sequence: 5
  givenname: Hideki
  surname: Fukumitsu
  fullname: Fukumitsu, Hideki
  organization: Department of Ophthalmology, Marina Baixa Hospital, Villajoyosa, Alicante, Spain
BackLink https://www.ncbi.nlm.nih.gov/pubmed/31246681$$D View this record in MEDLINE/PubMed
BookMark eNpNkNtKAzEQhoMo1lbfQCQv0LqnJLuXpXgotlY83ZZJMiuR3WxJssq-kw_prlZwbgb-wzcwY3JoG4uEnMfRLI4KcblcbGbRv0miNDsgJzFL-TQTRT4iY-_fe0MInhyTURonGed5fEK-5haqzhtPm5IubXDg0XvTWPqIO4QA0lQmdIO7UW0Fjs4lOtfUGJxRdI3gW4c12uApWE1foTIawgDoK3foIPxkO_rgmg-jUVPZUaD3-Dmcw7c-0GtPnQ9YU2Pp2lSahoauGz2Ucc9QjW39KTkqofJ4tt8T8nJ99by4na42N8vFfDVVKePZVGYFVykCY7mAsmC5VDkrIE3KSDDEMmIZz7QquIZM6CQty1iiypWQvcxkmUzIxS9318oa9XbnTA2u2_69LfkGu2N0vQ
CitedBy_id crossref_primary_10_1097_j_jcrs_0000000000000359
crossref_primary_10_1007_s00417_023_06348_y
crossref_primary_10_1080_02713683_2020_1822418
crossref_primary_10_18502_jovr_v18i4_14551
crossref_primary_10_1097_ICL_0000000000000787
crossref_primary_10_2174_1874364102014010059
crossref_primary_10_1111_cxo_13002
crossref_primary_10_3390_polym14235321
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.1097/ICO.0000000000002034
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
EISSN 1536-4798
ExternalDocumentID 31246681
Genre Validation Studies
Journal Article
GroupedDBID ---
.-D
.3C
.GJ
.Z2
01R
0R~
1J1
40H
4Q1
4Q2
4Q3
53G
5GY
5RE
5VS
71W
77Y
7O~
8L-
AAAAV
AAAXR
AAGIX
AAHPQ
AAIQE
AAMOA
AAMTA
AAQKA
AAQQT
AARTV
AASCR
AASOK
AAUEB
AAXQO
AAYEP
ABASU
ABBUW
ABDIG
ABJNI
ABVCZ
ABXRP
ABXVJ
ABZAD
ABZZY
ACCJW
ACDDN
ACDOF
ACEWG
ACGFO
ACGFS
ACIJW
ACILI
ACLDA
ACNCT
ACNWC
ACWDW
ACWRI
ACXJB
ACXNZ
ACZKN
ADFPA
ADGGA
ADHPY
ADNKB
AE3
AE6
AEETU
AENEX
AFBFQ
AFDTB
AFMBP
AFSOK
AFUWQ
AGINI
AHOMT
AHQNM
AHRYX
AHVBC
AIJEX
AINUH
AJCLO
AJIOK
AJNWD
AJNYG
AJZMW
AKCTQ
AKULP
ALKUP
ALMA_UNASSIGNED_HOLDINGS
ALMTX
AMJPA
AMKUR
AMNEI
AOHHW
AOQMC
BOYCO
BQLVK
BS7
C45
CGR
CS3
CUY
CVF
DIWNM
DU5
DUNZO
E.X
EBS
ECM
EEVPB
EIF
EJD
ERAAH
EX3
F2K
F2L
F2M
F2N
F5P
FCALG
FL-
FW0
GNXGY
GQDEL
H0~
HLJTE
HZ~
IKREB
IKYAY
IN~
IPNFZ
JF9
JG8
JK3
JK8
K8S
KD2
KMI
L-C
N9A
NPM
N~7
N~B
N~M
O9-
OAG
OAH
OCUKA
ODA
OL1
OLG
OLH
OLU
OLV
OLY
OLZ
OPUJH
ORVUJ
OUVQU
OVD
OVDNE
OVIDH
OVLEI
OVOZU
OWU
OWV
OWW
OWX
OWY
OWZ
OXXIT
P-K
P2P
R58
RIG
RLZ
S4R
S4S
T8P
TEORI
TSPGW
V2I
VVN
W3M
WOQ
WOW
X3V
X3W
XXN
XYM
YFH
ZB8
ZFV
ZGI
ZZMQN
ID FETCH-LOGICAL-c3564-b496c3ea5587af958bc859a32f075eef05464dc96da47d23ff1bec8c7b64d5bf2
IngestDate Thu Apr 03 07:09:41 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 9
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c3564-b496c3ea5587af958bc859a32f075eef05464dc96da47d23ff1bec8c7b64d5bf2
PMID 31246681
ParticipantIDs pubmed_primary_31246681
PublicationCentury 2000
PublicationDate 2019-Sep
PublicationDateYYYYMMDD 2019-09-01
PublicationDate_xml – month: 09
  year: 2019
  text: 2019-Sep
PublicationDecade 2010
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Cornea
PublicationTitleAlternate Cornea
PublicationYear 2019
SSID ssj0007762
Score 2.3408356
Snippet To evaluate the intrasession repeatability and validity of corneal curvature measurements provided by a new multifunctional device and to assess the...
SourceID pubmed
SourceType Index Database
StartPage 1097
SubjectTerms Aberrometry - instrumentation
Aberrometry - standards
Adolescent
Adult
Aged
Corneal Topography - instrumentation
Corneal Topography - standards
Female
Humans
Keratoconus - diagnosis
Male
Middle Aged
Prospective Studies
Reproducibility of Results
Young Adult
Title Analysis of Intrasession Repeatability of Ocular Aberrometric Measurements and Validation of Keratometry Provided by a New Integrated System in Mild to Moderate Keratoconus
URI https://www.ncbi.nlm.nih.gov/pubmed/31246681
Volume 38
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LbxMxELZSkKpeEO83mgM3ZMg-vT6WQtWA0laiRb1V9tqWIpXdKqQH8pv4X_wNxq9dUwUE5LCKPLveKPNpPDOe-UzIS82rBo2gpjmTmlr-EiozbaiuSsYFbw1Xrsr3sD44LT-cVWeTyY-kaulqJV-36419Jf-jVRxDvdou2X_Q7DApDuB31C9eUcN4_Ssdp4wiM5ul_epZNqxbjTbWU3C7LfQjX266K_XS8hNYWv5X8zE96ImaP6NPrgYX8qOlW3b32iZC16_nnFXhaiJnkWZCBdJzmziZLy6UdWbdAWsoC3NgyB3SC5ESoV92elgPjhd2t_5tpn3LjauyH9vOPvWrnh7iu_qxELwftomuFmu6b-uF_XkDWi0H2bGvAVjqNXWNab1yA-_cNMIIfRG2xELOIxuLunDJina6tknBJjXkRZMAlidW2e6yb1wuPA3xbO_I01iGTz71-dUEQZdfHIQK9Ibq2p8x82fpNRLvKNoiWxjO2PNZbVIpOAwMF6TY1cnZm00_Z4dsxymuxT_ODzq5TW6FAAZ2PRrvkInu7pLteSjRuEe-R1BCbyAFJfwCSiv1oIQUlJCCEhCUMILSPpKAEiIoQX4DAQhKGEEJHpSw6MCCElY9RFBCAsr75HT__cneAQ1HgtC2qOqSypLXbaFFVTVMGLQzsm0qLorcoOurtcEApC5Vy2slSqbywpgMjVTTMonDlTT5A3Kj6zv9iMBUo_PWcIYhQ1Y2gmGooVkutGkllyqfPiYP_f98ful5X86jBp78VvKU7IxwfUZuGjQ0-jl6rSv5wun8J7Zom1k
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Analysis+of+Intrasession+Repeatability+of+Ocular+Aberrometric+Measurements+and+Validation+of+Keratometry+Provided+by+a+New+Integrated+System+in+Mild+to+Moderate+Keratoconus&rft.jtitle=Cornea&rft.au=Pi%C3%B1ero%2C+David+P&rft.au=Soto-Negro%2C+Roberto&rft.au=Ruiz-Fortes%2C+Pedro&rft.au=P%C3%A9rez-Cambrod%C3%AD%2C+Rafael+J&rft.date=2019-09-01&rft.eissn=1536-4798&rft.volume=38&rft.issue=9&rft.spage=1097&rft_id=info:doi/10.1097%2FICO.0000000000002034&rft_id=info%3Apmid%2F31246681&rft_id=info%3Apmid%2F31246681&rft.externalDocID=31246681