Fusing Partial Camera Signals for Noncontact Pulse Rate Variability Measurement

Remote camera-based measurement of physiology has great potential for healthcare and affective computing. Recent advances in computer vision and signal processing have enabled photoplethysmography (PPG) measurement using commercially available cameras. However, there remain challenges in recovering...

Full description

Saved in:
Bibliographic Details
Published inIEEE transactions on biomedical engineering Vol. 65; no. 8; pp. 1725 - 1739
Main Authors McDuff, Daniel J., Blackford, Ethan B., Estepp, Justin R.
Format Journal Article
LanguageEnglish
Published United States IEEE 01.08.2018
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects
Online AccessGet full text

Cover

Loading…
Abstract Remote camera-based measurement of physiology has great potential for healthcare and affective computing. Recent advances in computer vision and signal processing have enabled photoplethysmography (PPG) measurement using commercially available cameras. However, there remain challenges in recovering accurate noncontact PPG measurements in the presence of rigid head motion. When a subject is moving, their face may be turned away from one camera, be obscured by an object, or move out of the frame resulting in missing observations. As the calculation of pulse rate variability (PRV) requires analysis over a time window of several minutes, the effect of missing observations on such features is deleterious. We present an approach for fusing partial color-channel signals from an array of cameras that enable physiology measurements to be made from moving subjects, even if they leave the frame of one or more cameras, which would not otherwise be possible with only a single camera. We systematically test our method on subjects (N=25) using a set of six, 5-min tasks (each repeated twice) involving different levels of head motion. This results in validation across 25 h of measurement. We evaluate pulse rate and PRV parameter estimation including statistical, geometric, and frequency-based measures. The median absolute error in pulse rate measurements was 0.57 beats-per-minute (BPM). In all but two tasks with the greatest motion, the median error was within 0.4 BPM of that from a contact PPG device. PRV estimates were significantly improved using our proposed approach compared to an alternative not designed to handle missing values and multiple camera signals; the error was reduced by over 50%. Without our proposed method, errors in pulse rate would be very high, and estimation of PRV parameters would not be feasible due to significant data loss.
AbstractList Remote camera-based measurement of physiology has great potential for healthcare and affective computing. Recent advances in computer vision and signal processing have enabled photoplethysmography (PPG) measurement using commercially available cameras. However, there remain challenges in recovering accurate noncontact PPG measurements in the presence of rigid head motion. When a subject is moving, their face may be turned away from one camera, be obscured by an object, or move out of the frame resulting in missing observations. As the calculation of pulse rate variability (PRV) requires analysis over a time window of several minutes, the effect of missing observations on such features is deleterious. We present an approach for fusing partial color-channel signals from an array of cameras that enable physiology measurements to be made from moving subjects, even if they leave the frame of one or more cameras, which would not otherwise be possible with only a single camera. We systematically test our method on subjects (N=25) using a set of six, 5-min tasks (each repeated twice) involving different levels of head motion. This results in validation across 25 h of measurement. We evaluate pulse rate and PRV parameter estimation including statistical, geometric, and frequency-based measures. The median absolute error in pulse rate measurements was 0.57 beats-per-minute (BPM). In all but two tasks with the greatest motion, the median error was within 0.4 BPM of that from a contact PPG device. PRV estimates were significantly improved using our proposed approach compared to an alternative not designed to handle missing values and multiple camera signals; the error was reduced by over 50%. Without our proposed method, errors in pulse rate would be very high, and estimation of PRV parameters would not be feasible due to significant data loss.
Remote camera-based measurement of physiology has great potential for healthcare and affective computing. Recent advances in computer vision and signal processing have enabled photoplethysmography (PPG) measurement using commercially available cameras. However, there remain challenges in recovering accurate noncontact PPG measurements in the presence of rigid head motion. When a subject is moving, their face may be turned away from one camera, be obscured by an object, or move out of the frame resulting in missing observations. As the calculation of pulse rate variability (PRV) requires analysis over a time window of several minutes, the effect of missing observations on such features is deleterious. We present an approach for fusing partial color-channel signals from an array of cameras that enable physiology measurements to be made from moving subjects, even if they leave the frame of one or more cameras, which would not otherwise be possible with only a single camera. We systematically test our method on subjects ( N=25) using a set of six, 5-min tasks (each repeated twice) involving different levels of head motion. This results in validation across 25 h of measurement. We evaluate pulse rate and PRV parameter estimation including statistical, geometric, and frequency-based measures. The median absolute error in pulse rate measurements was 0.57 beats-per-minute (BPM). In all but two tasks with the greatest motion, the median error was within 0.4 BPM of that from a contact PPG device. PRV estimates were significantly improved using our proposed approach compared to an alternative not designed to handle missing values and multiple camera signals; the error was reduced by over 50%. Without our proposed method, errors in pulse rate would be very high, and estimation of PRV parameters would not be feasible due to significant data loss.Remote camera-based measurement of physiology has great potential for healthcare and affective computing. Recent advances in computer vision and signal processing have enabled photoplethysmography (PPG) measurement using commercially available cameras. However, there remain challenges in recovering accurate noncontact PPG measurements in the presence of rigid head motion. When a subject is moving, their face may be turned away from one camera, be obscured by an object, or move out of the frame resulting in missing observations. As the calculation of pulse rate variability (PRV) requires analysis over a time window of several minutes, the effect of missing observations on such features is deleterious. We present an approach for fusing partial color-channel signals from an array of cameras that enable physiology measurements to be made from moving subjects, even if they leave the frame of one or more cameras, which would not otherwise be possible with only a single camera. We systematically test our method on subjects ( N=25) using a set of six, 5-min tasks (each repeated twice) involving different levels of head motion. This results in validation across 25 h of measurement. We evaluate pulse rate and PRV parameter estimation including statistical, geometric, and frequency-based measures. The median absolute error in pulse rate measurements was 0.57 beats-per-minute (BPM). In all but two tasks with the greatest motion, the median error was within 0.4 BPM of that from a contact PPG device. PRV estimates were significantly improved using our proposed approach compared to an alternative not designed to handle missing values and multiple camera signals; the error was reduced by over 50%. Without our proposed method, errors in pulse rate would be very high, and estimation of PRV parameters would not be feasible due to significant data loss.
Author Blackford, Ethan B.
Estepp, Justin R.
McDuff, Daniel J.
Author_xml – sequence: 1
  givenname: Daniel J.
  orcidid: 0000-0001-7313-0082
  surname: McDuff
  fullname: McDuff, Daniel J.
  email: damcduff@microsoft.com
  organization: Microsoft Research, Redmond, WA, USA
– sequence: 2
  givenname: Ethan B.
  surname: Blackford
  fullname: Blackford, Ethan B.
  organization: Ball Aerospace
– sequence: 3
  givenname: Justin R.
  orcidid: 0000-0001-8049-9582
  surname: Estepp
  fullname: Estepp, Justin R.
  organization: Air Force Research Laboratory, Wright-Patterson Air Force Base
BackLink https://www.ncbi.nlm.nih.gov/pubmed/29989930$$D View this record in MEDLINE/PubMed
BookMark eNp9kU1LHEEQhptgiKvJDxBBGnLxMpuu_tjpPprFj4BGSUyuTc1MjbTMh3b3HPz3zrJrDh5yKgqe54Wq94DtDeNAjB2BWAII9-3--835Ugool7IswYD9wBZgjC2kUbDHFkKALZx0ep8dpPQ4r9rq1Se2L52zzimxYLcXUwrDA7_DmAN2fI09ReS_w8OAXeLtGPnPcajHIWOd-d3UJeK_MBP_izFgFbqQX_gNYZoi9TTkz-xjO4v0ZTcP2Z-L8_v1VXF9e_ljfXZd1Eq7XKgKGttKMo3SVAnjSNeiqeZdgmzqxjWubW1VoUEsodIrsWqFVFY2VBI4rQ7Z6Tb3KY7PE6Xs-5Bq6jocaJySl2JllQEhYUa_vkMfxyluzvMSoBRGSKtm6mRHTVVPjX-Kocf44t9eNQPlFqjjmFKk1tchYw7zayKGzoPwm1L8phS_KcXvSplNeGe-hf_POd46gYj-8RaEcLpUr2OLlow
CODEN IEBEAX
CitedBy_id crossref_primary_10_1007_s11042_020_09075_2
crossref_primary_10_1109_JSEN_2023_3309994
crossref_primary_10_1007_s42979_022_01179_w
crossref_primary_10_1007_s11042_023_14399_w
crossref_primary_10_1109_TBME_2018_2882396
crossref_primary_10_1109_TIM_2018_2879706
crossref_primary_10_1002_aisy_202200345
crossref_primary_10_3390_s22114097
crossref_primary_10_3389_fnins_2020_561186
crossref_primary_10_1021_acssensors_0c02042
crossref_primary_10_1109_TPAMI_2023_3298650
crossref_primary_10_1109_JSEN_2023_3287555
crossref_primary_10_1109_ACCESS_2022_3231098
crossref_primary_10_3389_fphys_2022_801709
crossref_primary_10_3390_s20102752
crossref_primary_10_1007_s11760_024_03809_7
crossref_primary_10_1088_1361_6579_ab1f1d
crossref_primary_10_1109_JIOT_2022_3201910
crossref_primary_10_1016_j_neucom_2024_127282
crossref_primary_10_1145_3558518
Cites_doi 10.1042/cs0970391
10.1109/TBME.2014.2340991
10.1109/TBME.1985.325532
10.1111/j.1540-8167.2006.00501.x
10.1109/CVPRW.2016.46
10.1109/TBME.2010.2086456
10.1109/SMC.2014.6974121
10.1109/CVPR.2001.990517
10.2165/00007256-200333120-00003
10.1109/TBME.2013.2266196
10.1016/j.medengphy.2006.09.006
10.1109/TBME.1986.325695
10.1109/FG.2017.17
10.1109/TNN.2011.2106511
10.1109/TBME.2014.2323695
10.1016/j.ijcard.2012.03.119
10.1049/htl.2014.0077
10.1109/CVPR.2014.543
10.1088/0967-3334/35/9/1913
10.1109/TBME.2015.2508602
10.1109/CVPR.2013.75
10.1001/archderm.1988.01670060015008
10.1007/s10439-006-9198-1
10.1007/978-3-642-36480-8_19
10.1088/0967-3334/35/5/807
10.1016/j.neubiorev.2006.06.007
10.1364/OE.16.021434
10.1002/(SICI)1097-0193(1998)6:3<160::AID-HBM5>3.0.CO;2-1
10.1117/1.3602852
10.1093/oxfordjournals.eurheartj.a014868
10.1109/10.979357
10.1088/0967-3334/34/11/1499
10.1117/1.JBO.17.3.037005
10.1364/OE.18.004867
10.1145/2858036.2858247
10.1364/OE.18.010762
10.1109/TPAMI.2008.26
10.1364/BOE.6.003320
10.1109/EMBC.2015.7319857
10.1088/0967-3334/31/9/015
10.7326/0003-4819-118-6-199303150-00008
10.1126/science.6166045
10.1088/0967-3334/28/3/R01
10.1016/0301-0511(92)90017-O
10.1016/j.earlhumdev.2013.09.016
10.1145/2388676.2388709
ContentType Journal Article
Copyright Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2018
Copyright_xml – notice: Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2018
DBID 97E
RIA
RIE
AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
7QF
7QO
7QQ
7SC
7SE
7SP
7SR
7TA
7TB
7U5
8BQ
8FD
F28
FR3
H8D
JG9
JQ2
KR7
L7M
L~C
L~D
P64
7X8
DOI 10.1109/TBME.2017.2771518
DatabaseName IEEE All-Society Periodicals Package (ASPP) 2005–Present
IEEE All-Society Periodicals Package (ASPP) 1998–Present
IEEE/IET Electronic Library
CrossRef
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
Aluminium Industry Abstracts
Biotechnology Research Abstracts
Ceramic Abstracts
Computer and Information Systems Abstracts
Corrosion Abstracts
Electronics & Communications Abstracts
Engineered Materials Abstracts
Materials Business File
Mechanical & Transportation Engineering Abstracts
Solid State and Superconductivity Abstracts
METADEX
Technology Research Database
ANTE: Abstracts in New Technology & Engineering
Engineering Research Database
Aerospace Database
Materials Research Database
ProQuest Computer Science Collection
Civil Engineering Abstracts
Advanced Technologies Database with Aerospace
Computer and Information Systems Abstracts – Academic
Computer and Information Systems Abstracts Professional
Biotechnology and BioEngineering Abstracts
MEDLINE - Academic
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
Materials Research Database
Civil Engineering Abstracts
Aluminium Industry Abstracts
Technology Research Database
Computer and Information Systems Abstracts – Academic
Mechanical & Transportation Engineering Abstracts
Electronics & Communications Abstracts
ProQuest Computer Science Collection
Computer and Information Systems Abstracts
Ceramic Abstracts
Materials Business File
METADEX
Biotechnology and BioEngineering Abstracts
Computer and Information Systems Abstracts Professional
Aerospace Database
Engineered Materials Abstracts
Biotechnology Research Abstracts
Solid State and Superconductivity Abstracts
Engineering Research Database
Corrosion Abstracts
Advanced Technologies Database with Aerospace
ANTE: Abstracts in New Technology & Engineering
MEDLINE - Academic
DatabaseTitleList
MEDLINE - Academic
MEDLINE
Materials Research Database
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
– sequence: 3
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
Engineering
EISSN 1558-2531
EndPage 1739
ExternalDocumentID 29989930
10_1109_TBME_2017_2771518
8100947
Genre orig-research
Research Support, U.S. Gov't, Non-P.H.S
Journal Article
GrantInformation_xml – fundername: Air Force Office of Scientific Research
  funderid: 10.13039/100000181
– fundername: Air Force Research Laboratory Task
  grantid: #14RH07COR
GroupedDBID ---
-~X
.55
.DC
.GJ
0R~
29I
4.4
53G
5GY
5RE
5VS
6IF
6IK
6IL
6IN
85S
97E
AAJGR
AARMG
AASAJ
AAWTH
AAYJJ
ABAZT
ABJNI
ABQJQ
ABVLG
ACGFO
ACGFS
ACIWK
ACKIV
ACNCT
ACPRK
ADZIZ
AENEX
AETIX
AFFNX
AFRAH
AGQYO
AGSQL
AHBIQ
AI.
AIBXA
AKJIK
AKQYR
ALLEH
ALMA_UNASSIGNED_HOLDINGS
ASUFR
ATWAV
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CHZPO
CS3
DU5
EBS
EJD
F5P
HZ~
H~9
IAAWW
IBMZZ
ICLAB
IDIHD
IEGSK
IFIPE
IFJZH
IPLJI
JAVBF
LAI
MS~
O9-
OCL
P2P
RIA
RIE
RIL
RNS
TAE
TN5
VH1
VJK
X7M
ZGI
ZXP
AAYXX
CITATION
RIG
CGR
CUY
CVF
ECM
EIF
NPM
PKN
7QF
7QO
7QQ
7SC
7SE
7SP
7SR
7TA
7TB
7U5
8BQ
8FD
F28
FR3
H8D
JG9
JQ2
KR7
L7M
L~C
L~D
P64
7X8
ID FETCH-LOGICAL-c349t-3b1d8f2e5d34eb059e4c0dbe5d212dcd9d9ff8bba5aa71b4606f02382de7e1943
IEDL.DBID RIE
ISSN 0018-9294
1558-2531
IngestDate Thu Jul 10 16:54:56 EDT 2025
Sat Aug 23 13:08:12 EDT 2025
Wed Feb 19 02:36:38 EST 2025
Thu Apr 24 23:12:39 EDT 2025
Tue Jul 01 03:28:30 EDT 2025
Wed Aug 27 02:53:47 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 8
Language English
License https://ieeexplore.ieee.org/Xplorehelp/downloads/license-information/IEEE.html
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c349t-3b1d8f2e5d34eb059e4c0dbe5d212dcd9d9ff8bba5aa71b4606f02382de7e1943
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ORCID 0000-0001-7313-0082
0000-0001-8049-9582
PMID 29989930
PQID 2117050283
PQPubID 85474
PageCount 15
ParticipantIDs pubmed_primary_29989930
proquest_miscellaneous_2068351021
proquest_journals_2117050283
crossref_citationtrail_10_1109_TBME_2017_2771518
ieee_primary_8100947
crossref_primary_10_1109_TBME_2017_2771518
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2018-08-01
PublicationDateYYYYMMDD 2018-08-01
PublicationDate_xml – month: 08
  year: 2018
  text: 2018-08-01
  day: 01
PublicationDecade 2010
PublicationPlace United States
PublicationPlace_xml – name: United States
– name: New York
PublicationTitle IEEE transactions on biomedical engineering
PublicationTitleAbbrev TBME
PublicationTitleAlternate IEEE Trans Biomed Eng
PublicationYear 2018
Publisher IEEE
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Publisher_xml – name: IEEE
– name: The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
References ref14
ref53
ref52
ref11
ref10
humphreys (ref44) 2007
li (ref23) 0
ref17
ref16
ref51
ref50
ref46
ref45
ref47
ref42
ref41
ref43
ref49
ref8
ref7
ref9
ref4
ref3
ref6
ref5
ref40
lempe (ref12) 2013
ref35
ref34
ref37
ref36
ref31
ref30
ref33
ref32
lewandowska (ref19) 0
ref2
ref1
ref39
ref38
blackford (ref13) 0; 9417
ref24
blackford (ref54) 0; 10072
ref26
ref25
ref20
ref22
ref21
ref28
ref27
camm (ref48) 1996; 17
kwon (ref18) 0
ref29
blackford (ref15) 0; 10072
References_xml – start-page: 2174
  year: 0
  ident: ref18
  article-title: Validation of heart rate extraction using video imaging on a built-in camera system of a smartphone
  publication-title: Proc 2012 Annu Int Conf IEEE Eng Med Biol Soc
– ident: ref33
  doi: 10.1042/cs0970391
– ident: ref11
  doi: 10.1109/TBME.2014.2340991
– ident: ref51
  doi: 10.1109/TBME.1985.325532
– ident: ref26
  doi: 10.1111/j.1540-8167.2006.00501.x
– ident: ref17
  doi: 10.1109/CVPRW.2016.46
– ident: ref5
  doi: 10.1109/TBME.2010.2086456
– ident: ref7
  doi: 10.1109/SMC.2014.6974121
– ident: ref45
  doi: 10.1109/CVPR.2001.990517
– ident: ref30
  doi: 10.2165/00007256-200333120-00003
– ident: ref36
  doi: 10.1109/TBME.2013.2266196
– ident: ref2
  doi: 10.1016/j.medengphy.2006.09.006
– ident: ref52
  doi: 10.1109/TBME.1986.325695
– ident: ref40
  doi: 10.1109/FG.2017.17
– ident: ref53
  doi: 10.1109/TNN.2011.2106511
– ident: ref35
  doi: 10.1109/TBME.2014.2323695
– ident: ref31
  doi: 10.1016/j.ijcard.2012.03.119
– ident: ref16
  doi: 10.1049/htl.2014.0077
– ident: ref10
  doi: 10.1109/CVPR.2014.543
– ident: ref8
  doi: 10.1088/0967-3334/35/9/1913
– ident: ref24
  doi: 10.1109/TBME.2015.2508602
– volume: 10072
  year: 0
  ident: ref15
  article-title: Using consumer-grade devices for multi-imager non-contact imaging photoplethysmography
  publication-title: Proc SPIE
– ident: ref46
  doi: 10.1109/CVPR.2013.75
– year: 2007
  ident: ref44
  article-title: An investigation of remote non-contact photoplethysmography and pulse oximetry
– ident: ref50
  doi: 10.1001/archderm.1988.01670060015008
– volume: 10072
  start-page: 100720r
  year: 0
  ident: ref54
  article-title: A multispectral testbed for cardiovascular sensing using imaging photoplethysmography
  publication-title: Proc SPIE
– ident: ref43
  doi: 10.1007/s10439-006-9198-1
– start-page: 99
  year: 2013
  ident: ref12
  article-title: Roi selection for remote photoplethysmography
  publication-title: Bildverarbeitung fur Die Medizin 2013
  doi: 10.1007/978-3-642-36480-8_19
– ident: ref41
  doi: 10.1088/0967-3334/35/5/807
– ident: ref21
  doi: 10.1016/j.neubiorev.2006.06.007
– ident: ref3
  doi: 10.1364/OE.16.021434
– ident: ref22
  doi: 10.1002/(SICI)1097-0193(1998)6:3<160::AID-HBM5>3.0.CO;2-1
– ident: ref38
  doi: 10.1109/TBME.2015.2508602
– ident: ref9
  doi: 10.1117/1.3602852
– volume: 17
  start-page: 354
  year: 1996
  ident: ref48
  article-title: Heart rate variability: Standards of measurement, physiological interpretation, and clinical use. Task force of the European Society of Cardiology and the North American society of Pacing and Electrophysiology
  publication-title: Eur Heart J
  doi: 10.1093/oxfordjournals.eurheartj.a014868
– ident: ref47
  doi: 10.1109/10.979357
– ident: ref20
  doi: 10.1088/0967-3334/34/11/1499
– ident: ref39
  doi: 10.1117/1.JBO.17.3.037005
– ident: ref37
  doi: 10.1364/OE.18.004867
– ident: ref28
  doi: 10.1145/2858036.2858247
– ident: ref4
  doi: 10.1364/OE.18.010762
– volume: 9417
  year: 0
  ident: ref13
  article-title: Effects of frame rate and image resolution on pulse rate measured using multiple camera imaging photoplethysmography
  publication-title: Proc SPIE
– ident: ref29
  doi: 10.1109/TPAMI.2008.26
– ident: ref6
  doi: 10.1364/BOE.6.003320
– ident: ref14
  doi: 10.1109/EMBC.2015.7319857
– start-page: 405
  year: 0
  ident: ref19
  article-title: Measuring pulse rate with a webcam-A non-contact method for evaluating cardiac activity
  publication-title: 2011 Fed Conf Comput Sci Inf Syst
– start-page: 1
  year: 0
  ident: ref23
  article-title: A real-time non-contact pulse rate detector based on smartphone
  publication-title: Proc 2015 Int Symp Next-Gener Electron
– ident: ref32
  doi: 10.1088/0967-3334/31/9/015
– ident: ref25
  doi: 10.7326/0003-4819-118-6-199303150-00008
– ident: ref49
  doi: 10.1126/science.6166045
– ident: ref1
  doi: 10.1088/0967-3334/28/3/R01
– ident: ref27
  doi: 10.1016/0301-0511(92)90017-O
– ident: ref42
  doi: 10.1016/j.earlhumdev.2013.09.016
– ident: ref34
  doi: 10.1145/2388676.2388709
SSID ssj0014846
Score 2.3995466
Snippet Remote camera-based measurement of physiology has great potential for healthcare and affective computing. Recent advances in computer vision and signal...
SourceID proquest
pubmed
crossref
ieee
SourceType Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage 1725
SubjectTerms Adolescent
Adult
Affective computing
Biomedical monitoring
camera
Cameras
Computer vision
Data loss
Data processing
Errors
Face
Face - diagnostic imaging
Female
Head movement
Humans
Image color analysis
Image Processing, Computer-Assisted - methods
Male
Median (statistics)
non-contact
Parameter estimation
Photoplethysmography (PPG)
Photoplethysmography - methods
Physiology
Pulse - methods
Pulse measurements
Pulse rate
pulse rate variability (PRV)
Signal processing
Signal Processing, Computer-Assisted
Test procedures
Windows (intervals)
Young Adult
Title Fusing Partial Camera Signals for Noncontact Pulse Rate Variability Measurement
URI https://ieeexplore.ieee.org/document/8100947
https://www.ncbi.nlm.nih.gov/pubmed/29989930
https://www.proquest.com/docview/2117050283
https://www.proquest.com/docview/2068351021
Volume 65
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3Nb9UwDLe2HRAcBmx8FAYKEidE35qPLs0Rpj1NSB0TbGi3qnHSaQL1TdAe4K_HbvvKhABxa9WkH7FT_xz_YgO8zPLCqmBNimR8UlOgTj0am9aKNABR-izyBufy5OD43Ly7yC824PW8FybGOJDP4oIPh1h-WGHPS2X7hWQinN2ETXLcxr1ac8TAFOOmnEzSBFbOTBFMmbn9s7flEZO47EJZSxaOa_TRX5g8DeY-3zBHQ32Vv0PNweQs70K5ftmRafJ50Xd-gT9-y-P4v19zD7Yn7CnejMpyHzZiuwN3bmQk3IFb5RRr34X3S-bEX4pTVi7qdljz-pX4eHXJKZcFgV1xsmqZ6l5jJ057srHiAyFX8Ync7zH793dR_lqCfADny6Ozw-N0Kr-QojauS7WXoWhUzIM20RMMiwaz4OmczF3A4IJrmsL7Oq9rK70hV6hhBKBCtFE6ox_CVrtq42MQRqNVvtHoJBqn0RNOkLLReWPpD1NjAtlaChVOucm5RMaXavBRMlexDCuWYTXJMIFXc5frMTHHvxrv8vjPDaehT2BvLepqmrrfKsW1eHKGXQm8mC_TpONISt3GVU9tsgNCrlwVPYFHo4rM915r1pM_P_Mp3FasowOHcA-2uq99fEa4pvPPB4X-CThm8CM
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwzV1Lb9QwEB6VIvE48GihBAoYCS5I2caP1MmBA5SutrRZKthWvYX4kaoCZRFNhMpv4a_w35hJsqFCwK0St0SxE8Wexzf25xmAp1GcaOG0Ci06n1AlVobGKh0WAiXAWm4iTwecs-nm5EC9OYqPluD7cBbGe9-Sz_yILtu9fDe3DS2VbSSciHC6p1Du-rOvGKCdvth5jbP5TIjx9mxrEvY1BEIrVVqH0nCXlMLHTipvEEt4ZSNn8B5ttrMudWlZJsYUcVFobhTi-ZLcmHBeewzwJb73ElxGnBGL7nTYsEehku4YUMTRZIhU9XumPEo3Zq-ybaKN6ZHQGn0qVQVEu4-xDbGtzznAtqLL38Ft6-TGN-HHYng6bsvHUVObkf32W-bI_3X8bsGNHl2zl5063IYlX63A9XM5F1fgStazCVbh7ZhY_8dsn9QHu20VtELH3p8cU1JphnCeTecVkfkLW7P9BlEEe4fYnB0WqLYtq_iMZb8WWe_AwYX83F1YruaVvwdMSauFKaVNuVWptAaREOeljEuNNrSwAUSLWc9tn32dioB8ytsoLEpzkpmcZCbvZSaA50OXz13qkX81XqX5Hhr2Ux3A-kK08t44neaCqg3FBCwDeDI8RrNCe0VF5ecNtok2EZtT3fcA1jqRHN69kOT7f_7mY7g6mWV7-d7OdPcBXBOkHy1jch2W6y-Nf4gorjaPWmVi8OGipe8nLZ9QHg
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Fusing+Partial+Camera+Signals+for+Noncontact+Pulse+Rate+Variability+Measurement&rft.jtitle=IEEE+transactions+on+biomedical+engineering&rft.au=McDuff%2C+Daniel+J.&rft.au=Blackford%2C+Ethan+B.&rft.au=Estepp%2C+Justin+R.&rft.date=2018-08-01&rft.issn=0018-9294&rft.eissn=1558-2531&rft.volume=65&rft.issue=8&rft.spage=1725&rft.epage=1739&rft_id=info:doi/10.1109%2FTBME.2017.2771518&rft.externalDBID=n%2Fa&rft.externalDocID=10_1109_TBME_2017_2771518
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0018-9294&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0018-9294&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0018-9294&client=summon