Impact of transverse magnetic fields on dose response of a radiophotoluminescent glass dosimeter in megavoltage photon beams

The purpose of this study was to investigate the impact of transverse magnetic fields on the dose response of a radiophotoluminescent glass dosimeter (RGD) in megavoltage photon beams. The RGD relative response (i.e., RGD dose per absorbed dose to water at the midpoint of the detector in the absence...

Full description

Saved in:
Bibliographic Details
Published inMedical physics (Lancaster) Vol. 47; no. 4; p. 1995
Main Authors Ito, Shotaro, Araki, Fujio, Ohno, Takeshi
Format Journal Article
LanguageEnglish
Published United States 01.04.2020
Subjects
Online AccessGet more information

Cover

Loading…
Abstract The purpose of this study was to investigate the impact of transverse magnetic fields on the dose response of a radiophotoluminescent glass dosimeter (RGD) in megavoltage photon beams. The RGD relative response (i.e., RGD dose per absorbed dose to water at the midpoint of the detector in the absence of the detector) was calculated using Monte Carlo (MC) simulations. Note that the Monte Carlo calculations do not account for changes of the signal production per unit dose to the RGD caused by the magnetic field strength. The relative energy response R , the relative magnetic response R , and the relative overall response R with the transverse magnetic fields of 0-3 T were analyzed as a function of depth, for a 10 cm × 10 cm field in a solid water phantom, for 4-18 MV photons. Although magnetic resonance (MR) linacs with flattening filter free beams are commercially available, flattening filter beams were used to investigate the RGD response in this study. R is the response in beam quality Q relative to that in the reference beam with quality 6 MV, R is the response in beam quality Q with the magnetic field relative to that in beam quality Q without the magnetic field, and the R is the response in beam quality Q with the magnetic field relative to that in the reference beam with quality 6 MV without the magnetic field. Two RGD orientations were considered: RGD long axis is parallel (direction A) and perpendicular (direction B) to the magnetic field. The reference irradiation conditions were at the depth of 10 cm for a 10 cm × 10 cm field for 6 MV, without the magnetic field. In addition, the influence of a small air-gap between the holder inner wall and the RGD on the dose response in the magnetic field, R , was analyzed in detail. R is the response in beam quality Q without/with the air-gap. R decreased by up to 2.7% as the energy increased in the range of 4-18 MV, except in the buildup region. In direction A, the variation of R owing to the magnetic field strength was below 1.0%, regardless of the photon energy. In contrast, in direction B, R decreased with increasing magnetic field strength and decreased up to 4.0% at 3 T for 10 MV. The R for 0.03 and 0.05 cm air-gap models in direction A decreased up to 2.3% and up to 4.0%, respectively. The variation of R changed with the direction of the RGD relative to the magnetic field. For dose measurements, RGDs should be positioned with the long axis parallel to the magnetic field, without air-gaps.
AbstractList The purpose of this study was to investigate the impact of transverse magnetic fields on the dose response of a radiophotoluminescent glass dosimeter (RGD) in megavoltage photon beams. The RGD relative response (i.e., RGD dose per absorbed dose to water at the midpoint of the detector in the absence of the detector) was calculated using Monte Carlo (MC) simulations. Note that the Monte Carlo calculations do not account for changes of the signal production per unit dose to the RGD caused by the magnetic field strength. The relative energy response R , the relative magnetic response R , and the relative overall response R with the transverse magnetic fields of 0-3 T were analyzed as a function of depth, for a 10 cm × 10 cm field in a solid water phantom, for 4-18 MV photons. Although magnetic resonance (MR) linacs with flattening filter free beams are commercially available, flattening filter beams were used to investigate the RGD response in this study. R is the response in beam quality Q relative to that in the reference beam with quality 6 MV, R is the response in beam quality Q with the magnetic field relative to that in beam quality Q without the magnetic field, and the R is the response in beam quality Q with the magnetic field relative to that in the reference beam with quality 6 MV without the magnetic field. Two RGD orientations were considered: RGD long axis is parallel (direction A) and perpendicular (direction B) to the magnetic field. The reference irradiation conditions were at the depth of 10 cm for a 10 cm × 10 cm field for 6 MV, without the magnetic field. In addition, the influence of a small air-gap between the holder inner wall and the RGD on the dose response in the magnetic field, R , was analyzed in detail. R is the response in beam quality Q without/with the air-gap. R decreased by up to 2.7% as the energy increased in the range of 4-18 MV, except in the buildup region. In direction A, the variation of R owing to the magnetic field strength was below 1.0%, regardless of the photon energy. In contrast, in direction B, R decreased with increasing magnetic field strength and decreased up to 4.0% at 3 T for 10 MV. The R for 0.03 and 0.05 cm air-gap models in direction A decreased up to 2.3% and up to 4.0%, respectively. The variation of R changed with the direction of the RGD relative to the magnetic field. For dose measurements, RGDs should be positioned with the long axis parallel to the magnetic field, without air-gaps.
Author Ito, Shotaro
Araki, Fujio
Ohno, Takeshi
Author_xml – sequence: 1
  givenname: Shotaro
  surname: Ito
  fullname: Ito, Shotaro
  organization: Graduate school of Health Sciences, Kumamoto University, 4-24-1 Kuhonji, Chuo-ku, Kumamoto, 862-0976, Japan
– sequence: 2
  givenname: Fujio
  surname: Araki
  fullname: Araki, Fujio
  organization: Department of Health Sciences, Faculty of Life Sciences, Kumamoto University, 4-24-1 Kuhonji, Chuo-ku, Kumamoto, 862-0976, Japan
– sequence: 3
  givenname: Takeshi
  surname: Ohno
  fullname: Ohno, Takeshi
  organization: Department of Health Sciences, Faculty of Life Sciences, Kumamoto University, 4-24-1 Kuhonji, Chuo-ku, Kumamoto, 862-0976, Japan
BackLink https://www.ncbi.nlm.nih.gov/pubmed/31990990$$D View this record in MEDLINE/PubMed
BookMark eNo1kFtLxDAQhYMo7kXBXyD5A9VJmu42j7J4WVjwRZ-XSTupkSYpTXZB8Mdbb3DgDOd8zMNZsNMQAzF2JeBGAMhbP9wIBZU6YXOp1mWhJOgZW6T0DgCrsoJzNiuF1jBpzj63fsAm82h5HjGkI42JuMcuUHYNt476NvEYeBunfKQ0xDAdE458xNbF4S3m2B-8C5QaCpl3Pab0jTtPmUbuAvfU4TH2GTviP3zghtCnC3ZmsU90-edL9vpw_7J5KnbPj9vN3a5oSlWrQgjbNnW9MrWpartGq6EiYy0hQYVaSlUiIDRkVqqCeiqM0UTrthVA2tRyya5__w4H46ndD6PzOH7s_2eQX8nyYjI
ContentType Journal Article
Copyright 2020 American Association of Physicists in Medicine.
Copyright_xml – notice: 2020 American Association of Physicists in Medicine.
DBID CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.1002/mp.14054
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
Physics
EISSN 2473-4209
ExternalDocumentID 31990990
Genre Journal Article
GrantInformation_xml – fundername: Ministry of Education, Culture, Sports, Science and Technology
  grantid: JP19K17273
GroupedDBID ---
--Z
-DZ
.GJ
0R~
1OB
1OC
29M
2WC
33P
36B
3O-
4.4
476
53G
5GY
5RE
5VS
AAHHS
AANLZ
AAQQT
AASGY
AAXRX
AAZKR
ABCUV
ABEFU
ABFTF
ABJNI
ABLJU
ABQWH
ABTAH
ABXGK
ACAHQ
ACBEA
ACCFJ
ACCZN
ACGFO
ACGFS
ACGOF
ACPOU
ACXBN
ACXQS
ADBBV
ADBTR
ADKYN
ADOZA
ADXAS
ADZMN
AEEZP
AEGXH
AEIGN
AENEX
AEQDE
AEUYR
AFBPY
AFFPM
AHBTC
AIACR
AIAGR
AITYG
AIURR
AIWBW
AJBDE
ALMA_UNASSIGNED_HOLDINGS
ALUQN
AMYDB
ASPBG
BFHJK
C45
CGR
CS3
CUY
CVF
DCZOG
DRFUL
DRMAN
DRSTM
DU5
EBD
EBS
ECM
EIF
EJD
EMB
EMOBN
F5P
G8K
HDBZQ
HGLYW
I-F
KBYEO
LATKE
LEEKS
LOXES
LUTES
LYRES
MEWTI
NPM
O9-
OVD
P2P
P2W
PALCI
PHY
RJQFR
RNS
ROL
SAMSI
SUPJJ
SV3
TEORI
TN5
TWZ
USG
WOHZO
WXSBR
XJT
ZGI
ZVN
ZXP
ZY4
ZZTAW
ID FETCH-LOGICAL-c3484-11fdc886b8b58f7af905ebffeae05a92243a0a0ceb64508ffebb9ee7dd10e9b82
IngestDate Sat Sep 28 08:35:34 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 4
Keywords MRI-guided radiation therapy
relative magnetic response
radiophotoluminescent glass dosimeter
Monte Carlo simulation
relative energy response
Language English
License 2020 American Association of Physicists in Medicine.
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c3484-11fdc886b8b58f7af905ebffeae05a92243a0a0ceb64508ffebb9ee7dd10e9b82
PMID 31990990
ParticipantIDs pubmed_primary_31990990
PublicationCentury 2000
PublicationDate April 2020
PublicationDateYYYYMMDD 2020-04-01
PublicationDate_xml – month: 04
  year: 2020
  text: April 2020
PublicationDecade 2020
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Medical physics (Lancaster)
PublicationTitleAlternate Med Phys
PublicationYear 2020
SSID ssj0006350
Score 2.3534455
Snippet The purpose of this study was to investigate the impact of transverse magnetic fields on the dose response of a radiophotoluminescent glass dosimeter (RGD) in...
SourceID pubmed
SourceType Index Database
StartPage 1995
SubjectTerms Glass
Luminescence
Magnetic Fields
Photons
Radiometry - instrumentation
Title Impact of transverse magnetic fields on dose response of a radiophotoluminescent glass dosimeter in megavoltage photon beams
URI https://www.ncbi.nlm.nih.gov/pubmed/31990990
Volume 47
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1La9wwEBabloZcSpu-0hc69GbcyrZsy8dSGpJC0kI3kFsY2VLWKWsvW-cSeuwP74xke03Y0sfFLJLWGM_nz-PRNzOMvSkSie8FfL7TPCpDWVZVqGKZhYCuiI3zrNQlhQZOTrOjM_npPD2fzX5OVEvXnX5b3mzNK_kfq-IY2pWyZP_BsuNJcQB_o33xiBbG41_Z-HhMcezolUMKC9KjXjaUmRg4cZrbDahIlL72aljjMyLXUNXtatF2xE4kfSeVZuB8aVpeL0kmQ8GQpbkEpLCOtD1ufRNoA32N86EVVL_b48MkLo5LudXgu36MoYZj17Ip-IpngXW7gRr41tmH11f1OPp54XqCB3P4Zr4v6mlwIhYTTYtxJBbLPAllLIop4_oamz2y5IQ-KV98K6_7OrHLFRK78EWnJ-ZdLZ19kUwK2ub78-ytCtvD1A7byRVx5SlFfPq3OTpkYihaLOJ3wyXssd3hb7c-SJxjMn_A7vdfFPy9h8dDNjPNPts96TUT--zeF2-VR-yHxwtvLd_ghQ944R4vvG044YUPeKHlwLfihTu88BEvvG74BC_c44U7vDxmZ4cf5x-Owr77RlgmUskwimxVKpVppVNlc7CFSI221oARKRTo-iUgQJRGZxK9fJzQujAmr6pImEKr-Am707SNeca4jdAjEIkGQPZHpxNiiHVSRjZXFeQmPWBP_R28WPkSKxfDvX3-25kXbG8DuJfsrsVn2rxCB7HTr50FfwGCCG0p
link.rule.ids 783
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Impact+of+transverse+magnetic+fields+on+dose+response+of+a+radiophotoluminescent+glass+dosimeter+in+megavoltage+photon+beams&rft.jtitle=Medical+physics+%28Lancaster%29&rft.au=Ito%2C+Shotaro&rft.au=Araki%2C+Fujio&rft.au=Ohno%2C+Takeshi&rft.date=2020-04-01&rft.eissn=2473-4209&rft.volume=47&rft.issue=4&rft.spage=1995&rft_id=info:doi/10.1002%2Fmp.14054&rft_id=info%3Apmid%2F31990990&rft_id=info%3Apmid%2F31990990&rft.externalDocID=31990990