Detection of high intensity transient signals (HITS): How and why?

HITS (high intensity transient signals) in transcranial Doppler recordings reflect either microemboli, both gaseous and solid, or artefacts. Various frequencies in number of microembolic signals (MES) have been reported in the same clinical condition. A possible explanation for these discrepancies m...

Full description

Saved in:
Bibliographic Details
Published inEuropean Journal of Ultrasound Vol. 7; no. 1; pp. 23 - 29
Main Authors Droste, Dirk W, Ringelstein, E.Bernd
Format Book Review Journal Article
LanguageEnglish
Published Ireland Elsevier Ireland Ltd 01.02.1998
Subjects
Online AccessGet full text

Cover

Loading…
Abstract HITS (high intensity transient signals) in transcranial Doppler recordings reflect either microemboli, both gaseous and solid, or artefacts. Various frequencies in number of microembolic signals (MES) have been reported in the same clinical condition. A possible explanation for these discrepancies may be different device settings and algorithms for embolus detection. For reproducibility of data, we suggest that studies on MES report the following parameters: (1) Ultrasound device; (2) transducer type; (3) insonated artery; (4) insonation depth; (5) algorithms for signal intensity measurement; (6) scale settings; (7) detection threshold; (8) axial extension of sample volume; (9) fast Fourier transform (FFT) size (number of points used); (10) FFT length (time); (11) FFT overlap; (12) transmitted ultrasound frequency; (13) high pass filter settings; and (14) recording time. No current system of automatic embolus detection has the full sensitivity and specificity required for clinical use. Therefore, each of the signals detected by these devices needs to be checked and verified by an experienced investigator. MES will help to identify the site and activity of the embolizing lesion. Microembolus detection might reduce the observation time and the number of patients needed to perform interventional trials. First, however, MES needs to be validated as a meaningful prognostic parameter. Microemboli originating from prosthetic cardiac valves are mainly gaseous. Therefore, they cannot serve as an indicator of the valves thromboembolic activity or the patient’s stroke risk.
AbstractList HITS (high intensity transient signals) in transcranial Doppler recordings reflect either microemboli, both gaseous and solid, or artefacts. Various frequencies in number of microembolic signals (MES) have been reported in the same clinical condition. A possible explanation for these discrepancies may be different device settings and algorithms for embolus detection. For reproducibility of data, we suggest that studies on MES report the following parameters: (1) Ultrasound device; (2) transducer type; (3) insonated artery; (4) insonation depth; (5) algorithms for signal intensity measurement; (6) scale settings; (7) detection threshold; (8) axial extension of sample volume; (9) fast Fourier transform (FFT) size (number of points used); (10) FFT length (time); (11) FFT overlap; (12) transmitted ultrasound frequency; (13) high pass filter settings; and (14) recording time. No current system of automatic embolus detection has the full sensitivity and specificity required for clinical use. Therefore, each of the signals detected by these devices needs to be checked and verified by an experienced investigator. MES will help to identify the site and activity of the embolizing lesion. Microembolus detection might reduce the observation time and the number of patients needed to perform interventional trials. First, however, MES needs to be validated as a meaningful prognostic parameter. Microemboli originating from prosthetic cardiac valves are mainly gaseous. Therefore, they cannot serve as an indicator of the valves thromboembolic activity or the patient’s stroke risk.
Author Ringelstein, E.Bernd
Droste, Dirk W
Author_xml – sequence: 1
  givenname: Dirk W
  surname: Droste
  fullname: Droste, Dirk W
– sequence: 2
  givenname: E.Bernd
  surname: Ringelstein
  fullname: Ringelstein, E.Bernd
BackLink https://www.ncbi.nlm.nih.gov/pubmed/9614287$$D View this record in MEDLINE/PubMed
BookMark eNqFkE1PAjEQhnvAIKI_gaQnA4fVdrfbbb0QxQ9ISDyACbdm6bZQA11si4R_b_kIV08zed-ZeTPPDWjY2ioAOhg9YITp4wTxlCcspbTLWQ8hhFEya4DWRb4GN95_R50SlDdBk1NMUla0wMurCkoGU1tYa7g0iyU0NijrTdjD4MrYKBugNwtbrjzsDkfTSe8JDusdLG0Fd8t9_xZc6eipu3Ntg6_3t-lgmIw_P0aD53EiM4JDggnReYaxLopSVpxyrStCOGdI5mk-51oVRFc81yjNi4xFYc6ynCFKUkq0Ylkb3J_ublz9s1U-iLXxUq1WpVX11ouCc0oIQ3EwPw1KV3vvlBYbZ9al2wuMxIGXOPISBzCCM3HkJWZxr3MO2M7XqrpsnWFFv3_yVfzy1ygnvIx0pKqMiwxFVZt_Ev4ApQV8hQ
CitedBy_id crossref_primary_10_1159_000047701
crossref_primary_10_1109_10_880094
crossref_primary_10_1155_2023_9921063
crossref_primary_10_1016_S0929_8266_02_00046_0
crossref_primary_10_1016_j_bspc_2019_101811
crossref_primary_10_1097_01_mat_0000214682_95834_de
crossref_primary_10_1111_j_1468_1331_2006_01616_x
crossref_primary_10_1159_000016069
crossref_primary_10_1016_S0035_3787_04_70865_6
crossref_primary_10_1046_j_1540_8183_2003_01054_x
crossref_primary_10_1179_016164105X15695
crossref_primary_10_1177_0267659108094350
crossref_primary_10_1179_016164107X164120
crossref_primary_10_1016_j_jtcvs_2005_02_068
crossref_primary_10_1097_00002480_200105000_00018
crossref_primary_10_1177_2150135120909761
crossref_primary_10_1177_15443167211002315
crossref_primary_10_2176_nmc_43_421
crossref_primary_10_1097_00004728_200103000_00017
crossref_primary_10_1159_000047742
Cites_doi 10.1161/01.STR.25.8.1570
10.1161/01.STR.26.7.1225
10.1161/01.STR.26.6.1123
10.1161/01.STR.28.2.322
10.1161/01.STR.24.11.1667
10.1161/01.STR.28.4.692
10.1093/brain/116.5.1005
10.1016/0140-6736(91)92916-P
10.1161/01.STR.27.7.1249
10.1161/01.STR.23.11.1652
10.1093/brain/118.4.1005
10.1161/01.STR.28.12.2453
10.1088/0967-3334/14/3/017
10.1080/01616412.1996.11740372
10.1161/01.STR.21.3.415
10.1161/01.STR.25.2.382
10.1161/01.STR.26.11.2184
10.1159/000108472
10.1161/01.STR.28.3.588
10.1055/s-2007-1004022
ContentType Book Review
Journal Article
Copyright 1998 Elsevier Science Ireland Ltd
Copyright 1998 Elsevier Science Ireland Ltd.
Copyright_xml – notice: 1998 Elsevier Science Ireland Ltd
– notice: Copyright 1998 Elsevier Science Ireland Ltd.
DBID CGR
CUY
CVF
ECM
EIF
NPM
AAYXX
CITATION
7X8
DOI 10.1016/S0929-8266(98)00010-X
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
CrossRef
MEDLINE - Academic
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
CrossRef
MEDLINE - Academic
DatabaseTitleList
MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
Engineering
Biology
EndPage 29
ExternalDocumentID 10_1016_S0929_8266_98_00010_X
9614287
S092982669800010X
Genre Journal Article
Review
GroupedDBID --K
--M
.~1
0R~
1B1
1RT
1~.
1~5
29G
4.4
4G.
53G
5GY
5VS
7-5
71M
8P~
AABNK
AACTN
AAEDT
AAEDW
AAIKJ
AAKOC
AALRI
AAOAW
AAQFI
AAQXK
AAXUO
ABMAC
ABNEU
ABOCM
ABXDB
ABYKQ
ACDAQ
ACFVG
ACGFS
ACIUM
ACNNM
ACRLP
ADBBV
ADEZE
ADMUD
AEKER
AFKWA
AFTJW
AGHFR
AGUBO
AGYEJ
AIEXJ
AIKHN
AITUG
AIVDX
AJBFU
AJOXV
ALMA_UNASSIGNED_HOLDINGS
AMFUW
AMRAJ
ASPBG
AVWKF
AXJTR
AZFZN
BKOJK
BLXMC
CS3
DU5
EBS
EFJIC
EFLBG
EJD
EO8
EO9
EP2
EP3
F5P
FDB
FGOYB
FIRID
FNPLU
FYGXN
G-Q
HZ~
IHE
KOM
M41
MO0
N9A
O-L
O9-
OAUVE
OGIMB
OZT
P-9
PC.
Q38
R2-
RIG
ROL
RPZ
SDF
SDG
SEW
SPC
SSQ
SSZ
T5K
UHS
AAXKI
AKRWK
CGR
CUY
CVF
ECM
EIF
NPM
AAYXX
CITATION
7X8
ID FETCH-LOGICAL-c341t-144f5311f77acd969ffd449980c525b9fe74fd95f025738b9fb8358064264fe83
IEDL.DBID AIKHN
ISSN 0929-8266
IngestDate Fri Jun 28 03:57:17 EDT 2024
Thu Sep 12 19:36:56 EDT 2024
Sat Sep 28 07:40:55 EDT 2024
Fri Feb 23 02:30:56 EST 2024
IsPeerReviewed true
IsScholarly true
Issue 1
Keywords Prosthetic cardiac values
Stroke
Transcranial Doppler
High intensity transient signals
Language English
License Copyright 1998 Elsevier Science Ireland Ltd.
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c341t-144f5311f77acd969ffd449980c525b9fe74fd95f025738b9fb8358064264fe83
Notes ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-3
content type line 23
ObjectType-Review-1
PMID 9614287
PQID 79964480
PQPubID 23479
PageCount 7
ParticipantIDs proquest_miscellaneous_79964480
crossref_primary_10_1016_S0929_8266_98_00010_X
pubmed_primary_9614287
elsevier_sciencedirect_doi_10_1016_S0929_8266_98_00010_X
PublicationCentury 1900
PublicationDate 1998-Feb
PublicationDateYYYYMMDD 1998-02-01
PublicationDate_xml – month: 02
  year: 1998
  text: 1998-Feb
PublicationDecade 1990
PublicationPlace Ireland
PublicationPlace_xml – name: Ireland
PublicationTitle European Journal of Ultrasound
PublicationTitleAlternate Eur J Ultrasound
PublicationYear 1998
Publisher Elsevier Ireland Ltd
Publisher_xml – name: Elsevier Ireland Ltd
References Russell (BIB18) 1992
Spencer (BIB22) 1990; 21
Droste (BIB9) 1997; 28
Markus (BIB14) 1993; 24
Siebler (BIB20) 1995; 26
Babikian (BIB1) 1994; 25
Braekken (BIB2) 1995; 26
Markus (BIB17) 1995; 118
Bush, Evans (BIB3) 1993; 14
Droste (BIB6) 1994; 4
Siebler (BIB21) 1992; 23
(BIB10) 1991; 337
Markus (BIB15) 1996; 27
Grosset (BIB12) 1994; 25
Droste (BIB7) 1996; 18
Siebler (BIB19) 1993; 116
Grosset (BIB11) 1994; 3
(BIB5) 1995; 26
Casty (BIB4) 1994; 15
Kaps (BIB13) 1997; 28
Markus, Molloy (BIB16) 1997; 28
Droste (BIB8) 1997; 28
Droste (10.1016/S0929-8266(98)00010-X_BIB8) 1997; 28
Droste (10.1016/S0929-8266(98)00010-X_BIB9) 1997; 28
(10.1016/S0929-8266(98)00010-X_BIB10) 1991; 337
Grosset (10.1016/S0929-8266(98)00010-X_BIB11) 1994; 3
Russell (10.1016/S0929-8266(98)00010-X_BIB18) 1992
Casty (10.1016/S0929-8266(98)00010-X_BIB4) 1994; 15
Siebler (10.1016/S0929-8266(98)00010-X_BIB19) 1993; 116
Braekken (10.1016/S0929-8266(98)00010-X_BIB2) 1995; 26
Babikian (10.1016/S0929-8266(98)00010-X_BIB1) 1994; 25
Grosset (10.1016/S0929-8266(98)00010-X_BIB12) 1994; 25
(10.1016/S0929-8266(98)00010-X_BIB5) 1995; 26
Siebler (10.1016/S0929-8266(98)00010-X_BIB21) 1992; 23
Markus (10.1016/S0929-8266(98)00010-X_BIB14) 1993; 24
Markus (10.1016/S0929-8266(98)00010-X_BIB15) 1996; 27
Droste (10.1016/S0929-8266(98)00010-X_BIB7) 1996; 18
Kaps (10.1016/S0929-8266(98)00010-X_BIB13) 1997; 28
Markus (10.1016/S0929-8266(98)00010-X_BIB17) 1995; 118
Droste (10.1016/S0929-8266(98)00010-X_BIB6) 1994; 4
Markus (10.1016/S0929-8266(98)00010-X_BIB16) 1997; 28
Bush (10.1016/S0929-8266(98)00010-X_BIB3) 1993; 14
Siebler (10.1016/S0929-8266(98)00010-X_BIB20) 1995; 26
Spencer (10.1016/S0929-8266(98)00010-X_BIB22) 1990; 21
References_xml – volume: 116
  start-page: 1005
  year: 1993
  end-page: 1015
  ident: BIB19
  article-title: Silent cerebral embolism caused by neurologically symptomatic high-grade carotid stenosis
  publication-title: Brain
  contributor:
    fullname: Siebler
– volume: 21
  start-page: 415
  year: 1990
  end-page: 423
  ident: BIB22
  article-title: Detection of middle cerebral artery emboli during carotid endarterectomy using transcranial Doppler ultrasonography
  publication-title: Stroke
  contributor:
    fullname: Spencer
– volume: 26
  start-page: 2184
  year: 1995
  end-page: 2186
  ident: BIB20
  article-title: Cerebral microembolism and the risk of ischemia in asymptomatic high-grade internal carotid artery stenosis
  publication-title: Stroke
  contributor:
    fullname: Siebler
– volume: 26
  start-page: 1123
  year: 1995
  ident: BIB5
  article-title: Basic identification criteria of Doppler microembolic signals
  publication-title: Stroke
– volume: 4
  start-page: 152
  year: 1994
  end-page: 156
  ident: BIB6
  article-title: The effect of different settings of ultrasound pulse amplitude, gain and sample volume on the appearance of emboli studied in a transcranial Doppler model
  publication-title: Cerebrovasc Dis
  contributor:
    fullname: Droste
– volume: 18
  start-page: 25
  year: 1996
  end-page: 30
  ident: BIB7
  article-title: Variability in occurrence of embolic signals in long term transcranial Doppler recordings
  publication-title: Neurol Res
  contributor:
    fullname: Droste
– volume: 25
  start-page: 382
  year: 1994
  end-page: 384
  ident: BIB12
  article-title: Doppler emboli signals vary according to stroke subtype
  publication-title: Stroke
  contributor:
    fullname: Grosset
– start-page: 52
  year: 1992
  end-page: 58
  ident: BIB18
  article-title: The detection of cerebral emboli using Doppler ultrasound
  publication-title: Transcranial Doppler
  contributor:
    fullname: Russell
– volume: 25
  start-page: 1570
  year: 1994
  end-page: 1573
  ident: BIB1
  article-title: Clinical correlates of high-intensity transient signals detected on transcranial Doppler sonography in patients with cerebrovascular disease
  publication-title: Stroke
  contributor:
    fullname: Babikian
– volume: 24
  start-page: 1667
  year: 1993
  end-page: 1672
  ident: BIB14
  article-title: Computerized detection of cerebral emboli and discrimination from artifact using Doppler ultrasound
  publication-title: Stroke
  contributor:
    fullname: Markus
– volume: 28
  start-page: 2453
  year: 1997
  end-page: 2456
  ident: BIB9
  article-title: Oxygen inhalation can differentiate gaseous from non-gaseous microemboli detected by transcranial Doppler ultrasound
  publication-title: Stroke
  contributor:
    fullname: Droste
– volume: 118
  start-page: 1005
  year: 1995
  end-page: 1011
  ident: BIB17
  article-title: Asymptomatic cerebral embolic signals in symptomatic and asymptomatic carotid artery disease
  publication-title: Brain
  contributor:
    fullname: Markus
– volume: 15
  start-page: 253
  year: 1994
  end-page: 258
  ident: BIB4
  article-title: Automated detection of microemboli in transcranial Doppler signals
  publication-title: Ultraschall Med
  contributor:
    fullname: Casty
– volume: 27
  start-page: 1249
  year: 1996
  end-page: 1252
  ident: BIB15
  article-title: How good is intercenter agreement in the identification of embolic signals in carotid artery disease?
  publication-title: Stroke
  contributor:
    fullname: Markus
– volume: 23
  start-page: 1652
  year: 1992
  end-page: 1654
  ident: BIB21
  article-title: Detection of intracranial emboli in patients with symptomatic extracranial carotid artery disease
  publication-title: Stroke
  contributor:
    fullname: Siebler
– volume: 26
  start-page: 1225
  year: 1995
  end-page: 1230
  ident: BIB2
  article-title: Incidence and frequency of cerebral embolic signals in patients with a similar bileaflet mechanical heart valve
  publication-title: Stroke
  contributor:
    fullname: Braekken
– volume: 337
  start-page: 1235
  year: 1991
  end-page: 1243
  ident: BIB10
  article-title: MRC European carotid surgery trial: Interim results for symptomatic patients with severe (70–99%) or with mild (0–29%) carotid stenosis
  publication-title: Lancet
– volume: 28
  start-page: 588
  year: 1997
  end-page: 592
  ident: BIB8
  article-title: Bigated transcranial Doppler for the detection of clinically silent circulating emboli in normal persons and patients with prosthetic cardiac valves
  publication-title: Stroke
  contributor:
    fullname: Droste
– volume: 3
  start-page: 128
  year: 1994
  end-page: 132
  ident: BIB11
  article-title: Ultrasound detection of cerebral emboli in patients with prosthetic heart valves
  publication-title: J Heart Valve Dis
  contributor:
    fullname: Grosset
– volume: 28
  start-page: 322
  year: 1997
  end-page: 325
  ident: BIB13
  article-title: Clinically silent microemboli in patients with artificial prosthetic aortic valves are predominantly gaseous and not solid
  publication-title: Stroke
  contributor:
    fullname: Kaps
– volume: 28
  start-page: 692
  year: 1997
  end-page: 695
  ident: BIB16
  article-title: Use of a decibel threshold in detecting Doppler embolic signals
  publication-title: Stroke
  contributor:
    fullname: Molloy
– volume: 14
  start-page: 381
  year: 1993
  end-page: 386
  ident: BIB3
  article-title: Digital audio tape as a method of storing Doppler ultrasound signals
  publication-title: Physiol Meas
  contributor:
    fullname: Evans
– volume: 25
  start-page: 1570
  year: 1994
  ident: 10.1016/S0929-8266(98)00010-X_BIB1
  article-title: Clinical correlates of high-intensity transient signals detected on transcranial Doppler sonography in patients with cerebrovascular disease
  publication-title: Stroke
  doi: 10.1161/01.STR.25.8.1570
  contributor:
    fullname: Babikian
– volume: 26
  start-page: 1225
  year: 1995
  ident: 10.1016/S0929-8266(98)00010-X_BIB2
  article-title: Incidence and frequency of cerebral embolic signals in patients with a similar bileaflet mechanical heart valve
  publication-title: Stroke
  doi: 10.1161/01.STR.26.7.1225
  contributor:
    fullname: Braekken
– volume: 3
  start-page: 128
  year: 1994
  ident: 10.1016/S0929-8266(98)00010-X_BIB11
  article-title: Ultrasound detection of cerebral emboli in patients with prosthetic heart valves
  publication-title: J Heart Valve Dis
  contributor:
    fullname: Grosset
– volume: 26
  start-page: 1123
  year: 1995
  ident: 10.1016/S0929-8266(98)00010-X_BIB5
  article-title: Basic identification criteria of Doppler microembolic signals
  publication-title: Stroke
  doi: 10.1161/01.STR.26.6.1123
– volume: 28
  start-page: 322
  year: 1997
  ident: 10.1016/S0929-8266(98)00010-X_BIB13
  article-title: Clinically silent microemboli in patients with artificial prosthetic aortic valves are predominantly gaseous and not solid
  publication-title: Stroke
  doi: 10.1161/01.STR.28.2.322
  contributor:
    fullname: Kaps
– volume: 24
  start-page: 1667
  year: 1993
  ident: 10.1016/S0929-8266(98)00010-X_BIB14
  article-title: Computerized detection of cerebral emboli and discrimination from artifact using Doppler ultrasound
  publication-title: Stroke
  doi: 10.1161/01.STR.24.11.1667
  contributor:
    fullname: Markus
– volume: 28
  start-page: 692
  year: 1997
  ident: 10.1016/S0929-8266(98)00010-X_BIB16
  article-title: Use of a decibel threshold in detecting Doppler embolic signals
  publication-title: Stroke
  doi: 10.1161/01.STR.28.4.692
  contributor:
    fullname: Markus
– volume: 116
  start-page: 1005
  year: 1993
  ident: 10.1016/S0929-8266(98)00010-X_BIB19
  article-title: Silent cerebral embolism caused by neurologically symptomatic high-grade carotid stenosis
  publication-title: Brain
  doi: 10.1093/brain/116.5.1005
  contributor:
    fullname: Siebler
– volume: 337
  start-page: 1235
  year: 1991
  ident: 10.1016/S0929-8266(98)00010-X_BIB10
  article-title: MRC European carotid surgery trial: Interim results for symptomatic patients with severe (70–99%) or with mild (0–29%) carotid stenosis
  publication-title: Lancet
  doi: 10.1016/0140-6736(91)92916-P
– volume: 27
  start-page: 1249
  year: 1996
  ident: 10.1016/S0929-8266(98)00010-X_BIB15
  article-title: How good is intercenter agreement in the identification of embolic signals in carotid artery disease?
  publication-title: Stroke
  doi: 10.1161/01.STR.27.7.1249
  contributor:
    fullname: Markus
– volume: 23
  start-page: 1652
  year: 1992
  ident: 10.1016/S0929-8266(98)00010-X_BIB21
  article-title: Detection of intracranial emboli in patients with symptomatic extracranial carotid artery disease
  publication-title: Stroke
  doi: 10.1161/01.STR.23.11.1652
  contributor:
    fullname: Siebler
– volume: 118
  start-page: 1005
  year: 1995
  ident: 10.1016/S0929-8266(98)00010-X_BIB17
  article-title: Asymptomatic cerebral embolic signals in symptomatic and asymptomatic carotid artery disease
  publication-title: Brain
  doi: 10.1093/brain/118.4.1005
  contributor:
    fullname: Markus
– volume: 28
  start-page: 2453
  year: 1997
  ident: 10.1016/S0929-8266(98)00010-X_BIB9
  article-title: Oxygen inhalation can differentiate gaseous from non-gaseous microemboli detected by transcranial Doppler ultrasound
  publication-title: Stroke
  doi: 10.1161/01.STR.28.12.2453
  contributor:
    fullname: Droste
– start-page: 52
  year: 1992
  ident: 10.1016/S0929-8266(98)00010-X_BIB18
  article-title: The detection of cerebral emboli using Doppler ultrasound
  contributor:
    fullname: Russell
– volume: 14
  start-page: 381
  year: 1993
  ident: 10.1016/S0929-8266(98)00010-X_BIB3
  article-title: Digital audio tape as a method of storing Doppler ultrasound signals
  publication-title: Physiol Meas
  doi: 10.1088/0967-3334/14/3/017
  contributor:
    fullname: Bush
– volume: 18
  start-page: 25
  year: 1996
  ident: 10.1016/S0929-8266(98)00010-X_BIB7
  article-title: Variability in occurrence of embolic signals in long term transcranial Doppler recordings
  publication-title: Neurol Res
  doi: 10.1080/01616412.1996.11740372
  contributor:
    fullname: Droste
– volume: 21
  start-page: 415
  year: 1990
  ident: 10.1016/S0929-8266(98)00010-X_BIB22
  article-title: Detection of middle cerebral artery emboli during carotid endarterectomy using transcranial Doppler ultrasonography
  publication-title: Stroke
  doi: 10.1161/01.STR.21.3.415
  contributor:
    fullname: Spencer
– volume: 25
  start-page: 382
  year: 1994
  ident: 10.1016/S0929-8266(98)00010-X_BIB12
  article-title: Doppler emboli signals vary according to stroke subtype
  publication-title: Stroke
  doi: 10.1161/01.STR.25.2.382
  contributor:
    fullname: Grosset
– volume: 26
  start-page: 2184
  year: 1995
  ident: 10.1016/S0929-8266(98)00010-X_BIB20
  article-title: Cerebral microembolism and the risk of ischemia in asymptomatic high-grade internal carotid artery stenosis
  publication-title: Stroke
  doi: 10.1161/01.STR.26.11.2184
  contributor:
    fullname: Siebler
– volume: 4
  start-page: 152
  year: 1994
  ident: 10.1016/S0929-8266(98)00010-X_BIB6
  article-title: The effect of different settings of ultrasound pulse amplitude, gain and sample volume on the appearance of emboli studied in a transcranial Doppler model
  publication-title: Cerebrovasc Dis
  doi: 10.1159/000108472
  contributor:
    fullname: Droste
– volume: 28
  start-page: 588
  year: 1997
  ident: 10.1016/S0929-8266(98)00010-X_BIB8
  article-title: Bigated transcranial Doppler for the detection of clinically silent circulating emboli in normal persons and patients with prosthetic cardiac valves
  publication-title: Stroke
  doi: 10.1161/01.STR.28.3.588
  contributor:
    fullname: Droste
– volume: 15
  start-page: 253
  year: 1994
  ident: 10.1016/S0929-8266(98)00010-X_BIB4
  article-title: Automated detection of microemboli in transcranial Doppler signals
  publication-title: Ultraschall Med
  doi: 10.1055/s-2007-1004022
  contributor:
    fullname: Casty
SSID ssj0016405
Score 1.5515244
SecondaryResourceType review_article
Snippet HITS (high intensity transient signals) in transcranial Doppler recordings reflect either microemboli, both gaseous and solid, or artefacts. Various...
SourceID proquest
crossref
pubmed
elsevier
SourceType Aggregation Database
Index Database
Publisher
StartPage 23
SubjectTerms Carotid Stenosis - diagnostic imaging
Cerebrovascular Disorders - diagnostic imaging
Heart Valve Prosthesis - adverse effects
High intensity transient signals
Humans
Intracranial Embolism and Thrombosis - diagnostic imaging
Prosthetic cardiac values
Sensitivity and Specificity
Signal Processing, Computer-Assisted
Stroke
Transcranial Doppler
Ultrasonography, Doppler, Transcranial
Title Detection of high intensity transient signals (HITS): How and why?
URI https://dx.doi.org/10.1016/S0929-8266(98)00010-X
https://www.ncbi.nlm.nih.gov/pubmed/9614287
https://search.proquest.com/docview/79964480
Volume 7
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV07T8MwED61RSA6QQFRnh4YYEibtE5ssyCeCiBYACmbFae26JIiCKq68Ns5xwmFASGxWrET3dn33eW-OwMcaISh4UApPGm-8mgWDjwR8dCjKuMYPgeKC1vgfHcfxU_0JgmTBpzXtTCWVlnZfmfTS2tdjfQrafZfxuP-g4_Ijs5xJLh1VPykCQsIR5S2YOH0-ja-_0omRNQxGfF5z06YF_K4RcrBQ8GPynW85DeI-s0FLaHoagXatjyBuH_6q9DQeQcW3Y2Ssw60v_UX7MDSXZU5X4OzC12UrKucTAyxTYrJ2LHXixkpLGDZwkhi6Ry4IclhfP34cHRM4smUpPmITJ9nJ-vwdHX5eB571f0JXobYVHgoC4NHLDCMpdlIRMKYEcUIh_uoklAJoxk1IxEa9HvYkOOA4jYrGlkvyWg-3IBWPsn1JhBOFacYObJIB1QhhCmaasZMGmRCo0fUhV4tMvni2mTIOX8MZSytjKXgZbLbl0kXeC1Y-UPfEk35X1P3a0VIPAs2wZHmevL-JhkGbxhu-l3YcPr5-hYR2c5ybOv_b92GZVeOaJksO9AqXt_1LvojhdqDZu8j2Kt23SfrYdXy
link.rule.ids 314,315,786,790,798,4521,24144,27953,27955,27956,45618,45712
linkProvider Elsevier
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV07T8MwED7xEK8JChXl6YEBhtCUOrHNgsRL4VEWipTNilNbdEkRBKEu_Hbu4pTHgJBYLceJ7uy773LfnQH2LLqh7pExeNJCE_A8OgpULKOAm1xi-NwxUlGBc-8uTh74dRqlU3A2qYUhWmVt-71Nr6x1PdKupdl-Gg7b9yF6dgTHsZIEVMJ0GmYJDRCv6_D9k-eB4YDnMeLsgKZ_lfH4JarBfSUPqlWC9DcH9RsArRzR5TIsUXEC83_0V2DKFg2Y8_dJjhuw9K27YAPme3XefBVOz21Zca4KNnKMWhSzoeeul2NWkruiskhGZA7cjmw_uerfHxyzZPTGsmLA3h7HJ2vwcHnRP0uC-vaEIEfPVAYYKTk8YB0nRJYPVKycG3CMb2SIComMclZwN1CRQ9QjuhIHjKScaEwYyVnZbcJMMSrsOjDJjeQYN4rYdrhBB2Z4ZoVwWSdXFvFQCw4nItNPvkmG_mKPoYw1yVgrWaW6Q522QE4Eq39oW6Mh_-vR3YkiNJ4ESm9khR29vmiBoRsGm2ELml4_n9-iYuorJzb-_9ZdWEj6vVt9e3V3swmLvjCROC1bMFM-v9ptRCal2al23ge_09bH
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Detection+of+high+intensity+transient+signals+%28HITS%29%3A+How+and+why%3F&rft.jtitle=European+Journal+of+Ultrasound&rft.au=Droste%2C+Dirk+W&rft.au=Ringelstein%2C+E.Bernd&rft.date=1998-02-01&rft.pub=Elsevier+Ireland+Ltd&rft.issn=0929-8266&rft.volume=7&rft.issue=1&rft.spage=23&rft.epage=29&rft_id=info:doi/10.1016%2FS0929-8266%2898%2900010-X&rft.externalDocID=S092982669800010X
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0929-8266&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0929-8266&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0929-8266&client=summon