Self-measurement with Icare HOME tonometer, patients' feasibility and acceptability

To evaluate and compare the accuracy of self-measurement of intraocular pressure using Icare Home rebound tonometer with Goldmann applanation tonometer and assess acceptability of self-tonometry in patients with glaucoma and ocular hypertension. In the study, 117 subjects were trained to use Icare H...

Full description

Saved in:
Bibliographic Details
Published inEuropean journal of ophthalmology Vol. 30; no. 2; p. 258
Main Authors Cvenkel, Barbara, Velkovska, Makedonka Atanasovska, Jordanova, Vesna Dimovska
Format Journal Article
LanguageEnglish
Published United States 01.03.2020
Subjects
Online AccessGet more information
ISSN1724-6016
DOI10.1177/1120672118823124

Cover

Loading…
Abstract To evaluate and compare the accuracy of self-measurement of intraocular pressure using Icare Home rebound tonometer with Goldmann applanation tonometer and assess acceptability of self-tonometry in patients with glaucoma and ocular hypertension. In the study, 117 subjects were trained to use Icare Home for self-measurement. Icare Home tonometer readings were compared with Goldmann applanation tonometer, including one eye per patient. Agreement between the two methods of measurement was evaluated by Bland and Altmann analysis. Questionnaire was used to evaluate patients' perception of self-tonometry. One hundred and three out of 117 patients (88%) were able to measure their own intraocular pressure and 96 (82%) fulfilled the requirements for certification. The mean (SD) difference Goldmann applanation tonometer minus Icare Home was 1.2 (2.4) mmHg (95% limits of agreement, -3.4 to 5.9 mmHg). The magnitude of bias between the two methods depended on central corneal thickness, with greater bias at central corneal thickness <500 µm. In 65 out of 96 subjects (67.7%), Icare Home results were within 2 mmHg of the Goldmann applanation tonometer. Seventy-three out of 93 (78.5%) felt that self-tonometry was easy to use and 75 patients (80.6%) responded that they would use the device at home. Icare Home tonometry tends to slightly underestimate intraocular pressure compared to Goldmann applanation tonometer. Most patients were able to perform self-tonometry and found it acceptable for home use. Measurements using rebound self-tonometry could improve the quality of intraocular pressure data and optimize treatment regimen.
AbstractList To evaluate and compare the accuracy of self-measurement of intraocular pressure using Icare Home rebound tonometer with Goldmann applanation tonometer and assess acceptability of self-tonometry in patients with glaucoma and ocular hypertension. In the study, 117 subjects were trained to use Icare Home for self-measurement. Icare Home tonometer readings were compared with Goldmann applanation tonometer, including one eye per patient. Agreement between the two methods of measurement was evaluated by Bland and Altmann analysis. Questionnaire was used to evaluate patients' perception of self-tonometry. One hundred and three out of 117 patients (88%) were able to measure their own intraocular pressure and 96 (82%) fulfilled the requirements for certification. The mean (SD) difference Goldmann applanation tonometer minus Icare Home was 1.2 (2.4) mmHg (95% limits of agreement, -3.4 to 5.9 mmHg). The magnitude of bias between the two methods depended on central corneal thickness, with greater bias at central corneal thickness <500 µm. In 65 out of 96 subjects (67.7%), Icare Home results were within 2 mmHg of the Goldmann applanation tonometer. Seventy-three out of 93 (78.5%) felt that self-tonometry was easy to use and 75 patients (80.6%) responded that they would use the device at home. Icare Home tonometry tends to slightly underestimate intraocular pressure compared to Goldmann applanation tonometer. Most patients were able to perform self-tonometry and found it acceptable for home use. Measurements using rebound self-tonometry could improve the quality of intraocular pressure data and optimize treatment regimen.
Author Jordanova, Vesna Dimovska
Cvenkel, Barbara
Velkovska, Makedonka Atanasovska
Author_xml – sequence: 1
  givenname: Barbara
  surname: Cvenkel
  fullname: Cvenkel, Barbara
  organization: University of Ljubljana, Ljubljana, Slovenia
– sequence: 2
  givenname: Makedonka Atanasovska
  surname: Velkovska
  fullname: Velkovska, Makedonka Atanasovska
  organization: Department of Ophthalmology, University Medical Centre Ljubljana, Ljubljana, Slovenia
– sequence: 3
  givenname: Vesna Dimovska
  surname: Jordanova
  fullname: Jordanova, Vesna Dimovska
  organization: Saints Cyril and Methodius University of Skopje, Skopje, Republic of Macedonia
BackLink https://www.ncbi.nlm.nih.gov/pubmed/30632407$$D View this record in MEDLINE/PubMed
BookMark eNo1j01LAzEURYMoWqt7V5KdG0fzXjLJzFJKawuVLqrrksm8YGC-yKRI_70D1dWByz0X7i277PqOGHsA8QJgzCsACm0QoChQAqoLNgODKtMC9DW7kUJLVMLM2H5Pjc9asuMxUktd4j8hffONs5H4evex5Knv-pYSxWc-2BSmyvjE_SSEKjQhnbjtam6doyHZc3LHrrxtRrr_45x9rZafi3W23b1vFm_bzElpUpabUshcCe1QS4IcclV6TRalrY1wBqiyNSmFBFqV6J03pXIo6omlKjTO2eN5dzhWLdWHIYbWxtPh_x3-AlpUTho
CitedBy_id crossref_primary_10_2147_OPTH_S284844
crossref_primary_10_12688_f1000research_123104_2
crossref_primary_10_1111_aos_16789
crossref_primary_10_12688_f1000research_123104_1
crossref_primary_10_1016_j_ogla_2022_05_001
crossref_primary_10_1177_11206721221099252
crossref_primary_10_1016_j_ogla_2024_11_008
crossref_primary_10_2147_OPTH_S501234
crossref_primary_10_1097_OPX_0000000000001806
crossref_primary_10_3390_bioengineering11020138
crossref_primary_10_1111_ceo_13686
crossref_primary_10_1136_bmjopen_2021_049495
crossref_primary_10_3310_GTWD6802
crossref_primary_10_1097_IJG_0000000000002298
crossref_primary_10_1097_IJG_0000000000001670
crossref_primary_10_3390_jcm10173860
crossref_primary_10_1097_ICU_0000000000000730
crossref_primary_10_1097_IJG_0000000000001892
crossref_primary_10_1016_j_preteyeres_2024_101303
crossref_primary_10_1177_11206721221093990
crossref_primary_10_4103_sjopt_sjopt_138_24
crossref_primary_10_4103_IJO_IJO_147_23
crossref_primary_10_1016_j_ogla_2021_03_017
crossref_primary_10_1016_j_ophtha_2025_01_021
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.1177/1120672118823124
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
EISSN 1724-6016
ExternalDocumentID 30632407
Genre Journal Article
Comparative Study
GroupedDBID CGR
CUY
CVF
ECM
EIF
NPM
ID FETCH-LOGICAL-c337t-579035406c263e151549f6ea23ad70c71ebade442e16492fcf794c20df7994862
IngestDate Thu Jan 02 22:54:42 EST 2025
IsPeerReviewed true
IsScholarly true
Issue 2
Keywords Glaucoma
rebound tonometer
questionnaire
intraocular pressure
self-tonometry
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c337t-579035406c263e151549f6ea23ad70c71ebade442e16492fcf794c20df7994862
PMID 30632407
ParticipantIDs pubmed_primary_30632407
PublicationCentury 2000
PublicationDate 2020-Mar
PublicationDateYYYYMMDD 2020-03-01
PublicationDate_xml – month: 03
  year: 2020
  text: 2020-Mar
PublicationDecade 2020
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle European journal of ophthalmology
PublicationTitleAlternate Eur J Ophthalmol
PublicationYear 2020
Score 2.339605
Snippet To evaluate and compare the accuracy of self-measurement of intraocular pressure using Icare Home rebound tonometer with Goldmann applanation tonometer and...
SourceID pubmed
SourceType Index Database
StartPage 258
SubjectTerms Adolescent
Adult
Aged
Aged, 80 and over
Feasibility Studies
Female
Glaucoma, Open-Angle - physiopathology
Humans
Intraocular Pressure - physiology
Male
Middle Aged
Ocular Hypertension - physiopathology
Patient Acceptance of Health Care
Prospective Studies
Reproducibility of Results
Self Care - methods
Surveys and Questionnaires
Tonometry, Ocular - methods
Young Adult
Title Self-measurement with Icare HOME tonometer, patients' feasibility and acceptability
URI https://www.ncbi.nlm.nih.gov/pubmed/30632407
Volume 30
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LT9tAEF4FkBAXRNXS8tQeKvXQmgbvxo6PCAUFpNBKAcQNjXfHAjm2IxI48Bv40czu2rGTtgJ6sSNPbEs7n0fz-GaWsa_CjIED0F430B1PKhF5oA1xTQqIFXkQ2vZXDM6D_qU8u-5ct1rPDdbSwzQ-UE9_7Sv5H63SNdKr6ZJ9h2ZnD6UL9Jv0S0fSMB3fpOMhjhIvq7N8Lqt6atlc_V-DHjmWeZFhufdGOULV0iYSusnxYt38JVCG3uJmds8Veuey9aXnWoxvp7cwyuYy8sdkNVNs1jAqyRWO0uJxkoLrDUpRF3kK34_ILYWJFdQ0nnsNZpdWy77FSQ5kkrP6L2V2gkLRGT3rAJ1FDX3pmZkvTZNblmLuGpFvaT_dHPc_7bqtLJNvaCrHFBOZ4qXrvW6oeZxZPVMQZKYMhq9LFyZtV6IltkQxh9lE9fegrmz_XHz7Glut7liISaxvcrHB1suggh85hHxgLcw_suEiOrhBB7fo4AYdfIaOH7zCxjfeQAYnZPA5ZHxilye9i-O-V26h4SkhwqnXCaO2yewFyg8EGudVRkmA4AvQYVuFhxiDRil9pLA58hOVkH1WflvTOZIU7W6y5bzI8QvjMYiknSiEQ1RSd3wIgi5ogUIoHXdj2GKf3RrcjN2clJtqdbb_KdlhazVodtlKQh8m7pGXN4337fK_AGziVXg
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Self-measurement+with+Icare+HOME+tonometer%2C+patients%27+feasibility+and+acceptability&rft.jtitle=European+journal+of+ophthalmology&rft.au=Cvenkel%2C+Barbara&rft.au=Velkovska%2C+Makedonka+Atanasovska&rft.au=Jordanova%2C+Vesna+Dimovska&rft.date=2020-03-01&rft.eissn=1724-6016&rft.volume=30&rft.issue=2&rft.spage=258&rft_id=info:doi/10.1177%2F1120672118823124&rft_id=info%3Apmid%2F30632407&rft_id=info%3Apmid%2F30632407&rft.externalDocID=30632407