Repeatability of Manual Measurement of Foveal Avascular Zone Area in Optical Coherence Tomography Angiography Images in High Myopia

To analyze the repeatability of manual measurement of foveal avascular zone (FAZ) area in an optical coherence tomography angiography (OCTA) image in high myopia. This study comprised patients with high myopia and controls. Two consecutive FAZ areas of the superficial and deep capillary plexus were...

Full description

Saved in:
Bibliographic Details
Published inKorean journal of ophthalmology Vol. 34; no. 2; pp. 113 - 120
Main Authors Lee, Jong Ha, Lee, Min Woo, Baek, Seung Kook, Lee, Young Hoon
Format Journal Article
LanguageEnglish
Published Korea (South) The Korean Ophthalmological Society 01.04.2020
대한안과학회
Subjects
Online AccessGet full text
ISSN1011-8942
2092-9382
2092-9382
DOI10.3341/kjo.2019.0105

Cover

Abstract To analyze the repeatability of manual measurement of foveal avascular zone (FAZ) area in an optical coherence tomography angiography (OCTA) image in high myopia. This study comprised patients with high myopia and controls. Two consecutive FAZ areas of the superficial and deep capillary plexus were obtained using OCTA. The intraclass correlation coefficient (ICC) and coefficient of variation (CV) were assessed, and univariate and multivariate generalized linear mixed models were conducted to identify factors related to repeatability. Thirty eyes with high myopia and 34 eyes of healthy subjects were included in the study. The mean age in high myopia and control subjects was 55.5 and 60.8 years, respectively, the mean spherical equivalent was -9.98 and -0.55 diopters, and the mean axial length was 28.0 and 23.9 mm. The ICCs of FAZ area of the superficial capillary plexus (SCP) were 0.891 and 0.919, while the CVs were 8.8% and 8.5%. In measurement of the deep capillary plexus, the ICCs were 0.788 and 0.907, while the CVs were 11.2% and 11.0%, which were acceptable but exhibited lower repeatability than those of SCP. Multivariate analyses showed that older age ( = 0.030) and greater axial length ( = 0.005) were significantly associated with lower repeatability of SCP FAZ area measurements. In addition, greater axial length ( = 0.044) was a significant factor for lower repeatability of deep capillary plexus FAZ area measurements. Manual measurement of FAZ area using OCTA exhibited relatively good repeatability for high myopia. Age and axial length affected repeatability and should be considered when analyzing FAZ areas in high myopia patients.
AbstractList Purpose: To analyze the repeatability of manual measurement of foveal avascular zone (FAZ) area in an opticalcoherence tomography angiography (OCTA) image in high myopia. Methods: This study comprised patients with high myopia and controls. Two consecutive FAZ areas of the superficialand deep capillary plexus were obtained using OCTA. The intraclass correlation coefficient (ICC) andcoefficient of variation (CV) were assessed, and univariate and multivariate generalized linear mixed modelswere conducted to identify factors related to repeatability. Results: Thirty eyes with high myopia and 34 eyes of healthy subjects were included in the study. The meanage in high myopia and control subjects was 55.5 and 60.8 years, respectively, the mean spherical equivalentwas -9.98 and -0.55 diopters, and the mean axial length was 28.0 and 23.9 mm. The ICCs of FAZ area of thesuperficial capillary plexus (SCP) were 0.891 and 0.919, while the CVs were 8.8% and 8.5%. In measurementof the deep capillary plexus, the ICCs were 0.788 and 0.907, while the CVs were 11.2% and 11.0%, which wereacceptable but exhibited lower repeatability than those of SCP. Multivariate analyses showed that older age (p= 0.030) and greater axial length (p = 0.005) were significantly associated with lower repeatability of SCP FAZarea measurements. In addition, greater axial length (p = 0.044) was a significant factor for lower repeatabilityof deep capillary plexus FAZ area measurements. Conclusions: Manual measurement of FAZ area using OCTA exhibited relatively good repeatability for high myopia. Age and axial length affected repeatability and should be considered when analyzing FAZ areas in highmyopia patients. KCI Citation Count: 0
To analyze the repeatability of manual measurement of foveal avascular zone (FAZ) area in an optical coherence tomography angiography (OCTA) image in high myopia. This study comprised patients with high myopia and controls. Two consecutive FAZ areas of the superficial and deep capillary plexus were obtained using OCTA. The intraclass correlation coefficient (ICC) and coefficient of variation (CV) were assessed, and univariate and multivariate generalized linear mixed models were conducted to identify factors related to repeatability. Thirty eyes with high myopia and 34 eyes of healthy subjects were included in the study. The mean age in high myopia and control subjects was 55.5 and 60.8 years, respectively, the mean spherical equivalent was -9.98 and -0.55 diopters, and the mean axial length was 28.0 and 23.9 mm. The ICCs of FAZ area of the superficial capillary plexus (SCP) were 0.891 and 0.919, while the CVs were 8.8% and 8.5%. In measurement of the deep capillary plexus, the ICCs were 0.788 and 0.907, while the CVs were 11.2% and 11.0%, which were acceptable but exhibited lower repeatability than those of SCP. Multivariate analyses showed that older age ( = 0.030) and greater axial length ( = 0.005) were significantly associated with lower repeatability of SCP FAZ area measurements. In addition, greater axial length ( = 0.044) was a significant factor for lower repeatability of deep capillary plexus FAZ area measurements. Manual measurement of FAZ area using OCTA exhibited relatively good repeatability for high myopia. Age and axial length affected repeatability and should be considered when analyzing FAZ areas in high myopia patients.
To analyze the repeatability of manual measurement of foveal avascular zone (FAZ) area in an optical coherence tomography angiography (OCTA) image in high myopia.PURPOSETo analyze the repeatability of manual measurement of foveal avascular zone (FAZ) area in an optical coherence tomography angiography (OCTA) image in high myopia.This study comprised patients with high myopia and controls. Two consecutive FAZ areas of the superficial and deep capillary plexus were obtained using OCTA. The intraclass correlation coefficient (ICC) and coefficient of variation (CV) were assessed, and univariate and multivariate generalized linear mixed models were conducted to identify factors related to repeatability.METHODSThis study comprised patients with high myopia and controls. Two consecutive FAZ areas of the superficial and deep capillary plexus were obtained using OCTA. The intraclass correlation coefficient (ICC) and coefficient of variation (CV) were assessed, and univariate and multivariate generalized linear mixed models were conducted to identify factors related to repeatability.Thirty eyes with high myopia and 34 eyes of healthy subjects were included in the study. The mean age in high myopia and control subjects was 55.5 and 60.8 years, respectively, the mean spherical equivalent was -9.98 and -0.55 diopters, and the mean axial length was 28.0 and 23.9 mm. The ICCs of FAZ area of the superficial capillary plexus (SCP) were 0.891 and 0.919, while the CVs were 8.8% and 8.5%. In measurement of the deep capillary plexus, the ICCs were 0.788 and 0.907, while the CVs were 11.2% and 11.0%, which were acceptable but exhibited lower repeatability than those of SCP. Multivariate analyses showed that older age (p = 0.030) and greater axial length (p = 0.005) were significantly associated with lower repeatability of SCP FAZ area measurements. In addition, greater axial length (p = 0.044) was a significant factor for lower repeatability of deep capillary plexus FAZ area measurements.RESULTSThirty eyes with high myopia and 34 eyes of healthy subjects were included in the study. The mean age in high myopia and control subjects was 55.5 and 60.8 years, respectively, the mean spherical equivalent was -9.98 and -0.55 diopters, and the mean axial length was 28.0 and 23.9 mm. The ICCs of FAZ area of the superficial capillary plexus (SCP) were 0.891 and 0.919, while the CVs were 8.8% and 8.5%. In measurement of the deep capillary plexus, the ICCs were 0.788 and 0.907, while the CVs were 11.2% and 11.0%, which were acceptable but exhibited lower repeatability than those of SCP. Multivariate analyses showed that older age (p = 0.030) and greater axial length (p = 0.005) were significantly associated with lower repeatability of SCP FAZ area measurements. In addition, greater axial length (p = 0.044) was a significant factor for lower repeatability of deep capillary plexus FAZ area measurements.Manual measurement of FAZ area using OCTA exhibited relatively good repeatability for high myopia. Age and axial length affected repeatability and should be considered when analyzing FAZ areas in high myopia patients.CONCLUSIONSManual measurement of FAZ area using OCTA exhibited relatively good repeatability for high myopia. Age and axial length affected repeatability and should be considered when analyzing FAZ areas in high myopia patients.
Author Baek, Seung Kook
Lee, Jong Ha
Lee, Min Woo
Lee, Young Hoon
AuthorAffiliation Department of Ophthalmology, Konyang University College of Medicine, Daejeon, Korea
AuthorAffiliation_xml – name: Department of Ophthalmology, Konyang University College of Medicine, Daejeon, Korea
Author_xml – sequence: 1
  givenname: Jong Ha
  surname: Lee
  fullname: Lee, Jong Ha
  organization: Department of Ophthalmology, Konyang University College of Medicine, Daejeon, Korea
– sequence: 2
  givenname: Min Woo
  surname: Lee
  fullname: Lee, Min Woo
  organization: Department of Ophthalmology, Konyang University College of Medicine, Daejeon, Korea
– sequence: 3
  givenname: Seung Kook
  surname: Baek
  fullname: Baek, Seung Kook
  organization: Department of Ophthalmology, Konyang University College of Medicine, Daejeon, Korea
– sequence: 4
  givenname: Young Hoon
  surname: Lee
  fullname: Lee, Young Hoon
  organization: Department of Ophthalmology, Konyang University College of Medicine, Daejeon, Korea
BackLink https://www.ncbi.nlm.nih.gov/pubmed/32233144$$D View this record in MEDLINE/PubMed
https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002575674$$DAccess content in National Research Foundation of Korea (NRF)
BookMark eNp1kk1rGzEQhkVJaZy0x16Lju1hXX3sly4FY5rEEBMI7qUXIWtn14p3pa20a_C5f7zaOAlpoacRmmfeGWneC3RmnQWEPlIy5zylX_cPbs4IFXNCSfYGzRgRLBG8ZGdoRgmlSSlSdo4uQnggJKecFO_QOWeMc5qmM_T7HnpQg9qa1gxH7Gq8VnZULV6DCqOHDuww3V65A8TbxUEFPbbK459xDLzwoLCx-K4fjI7ppduBB6sBb1znGq_63REvbGOez6tONRCmkhvT7PD66Hqj3qO3tWoDfHiKl-jH1ffN8ia5vbteLRe3ieY8z5KMClCCV6JOWVqwitd1lWldZqIstI7PzjiFnFZ1BlSlQAhUkWaiKGNqW2p-ib6cdK2v5V4b6ZR5jI2Tey8X95uVFHleiCKN7LcT24_bDiodv8GrVvbedMofHyv_zlizizoHWcQ1FGUZBT4_CXj3a4QwyM4EDW2rLLgxSMbLjBVxJXlEP73u9dLkeUsRSE6A9i4ED_ULQomcXCCjC-TkAjm5IPL8H16bQQ3GTaOa9j9VfwCB6rcY
CitedBy_id crossref_primary_10_3341_kjo_2020_0143
crossref_primary_10_2147_OPTH_S389272
crossref_primary_10_1167_iovs_65_12_15
crossref_primary_10_3390_jcm12051846
crossref_primary_10_3389_fmed_2023_1161942
Cites_doi 10.1097/IJG.0000000000000385
10.1097/IJG.0000000000000768
10.1167/iovs.16-21079
10.1097/IAE.0000000000000765
10.1016/j.ophtha.2016.07.008
10.1038/s41433-019-0438-7
10.1111/j.1475-1313.2005.00298.x
10.1136/bjophthalmol-2015-307330
10.1001/jamaophthalmol.2017.0080
10.1371/journal.pone.0029692
10.1159/000485463
10.1136/bjophthalmol-2016-308764
10.1016/j.ophtha.2009.11.003
10.1159/000453112
10.1016/j.ajo.2018.01.033
10.1136/bjo.87.5.570
10.1001/jamaophthalmol.2014.3616
10.1016/j.ajo.2017.11.011
10.1001/jamaophthalmol.2017.3431
10.1136/bjophthalmol-2017-310569
10.1016/j.ajo.2015.05.015
ContentType Journal Article
Copyright 2020 The Korean Ophthalmological Society.
2020 The Korean Ophthalmological Society 2020 The Korean Ophthalmological Society
Copyright_xml – notice: 2020 The Korean Ophthalmological Society.
– notice: 2020 The Korean Ophthalmological Society 2020 The Korean Ophthalmological Society
DBID AAYXX
CITATION
NPM
7X8
5PM
ACYCR
DOI 10.3341/kjo.2019.0105
DatabaseName CrossRef
PubMed
MEDLINE - Academic
PubMed Central (Full Participant titles)
Korean Citation Index
DatabaseTitle CrossRef
PubMed
MEDLINE - Academic
DatabaseTitleList
PubMed
MEDLINE - Academic
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 2092-9382
EndPage 120
ExternalDocumentID oai_kci_go_kr_ARTI_9667974
PMC7105788
32233144
10_3341_kjo_2019_0105
Genre Journal Article
GroupedDBID ---
29L
2WC
5-W
53G
5GY
8JR
8XY
9ZL
AAYXX
ACYCR
ADBBV
ADRAZ
ALMA_UNASSIGNED_HOLDINGS
AOIJS
BAWUL
CITATION
CS3
DIK
E3Z
EBS
EF.
EJD
F5P
FRP
GROUPED_DOAJ
GX1
HYE
KQ8
M48
MZR
O5R
O5S
OK1
P5Y
P6G
PGMZT
RPM
TR2
ZZE
HZB
M~E
NPM
7X8
85H
5PM
ID FETCH-LOGICAL-c3365-519ea93d9f42472d3ffd5cc85987cc092531e61df5e1a4e00ed93d2978925b8c3
IEDL.DBID M48
ISSN 1011-8942
2092-9382
IngestDate Sun Mar 09 07:54:34 EDT 2025
Thu Aug 21 14:31:34 EDT 2025
Thu Sep 04 19:58:20 EDT 2025
Thu Jan 02 22:58:50 EST 2025
Tue Jul 01 02:57:32 EDT 2025
Thu Apr 24 23:02:56 EDT 2025
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 2
Keywords Repeatability
High myopia
Optical coherence tomography angiography
Foveal avascular zone
Language English
License http://creativecommons.org/licenses/by-nc/3.0
2020 The Korean Ophthalmological Society.
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c3365-519ea93d9f42472d3ffd5cc85987cc092531e61df5e1a4e00ed93d2978925b8c3
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
OpenAccessLink http://journals.scholarsportal.info/openUrl.xqy?doi=10.3341/kjo.2019.0105
PMID 32233144
PQID 2385270066
PQPubID 23479
PageCount 8
ParticipantIDs nrf_kci_oai_kci_go_kr_ARTI_9667974
pubmedcentral_primary_oai_pubmedcentral_nih_gov_7105788
proquest_miscellaneous_2385270066
pubmed_primary_32233144
crossref_primary_10_3341_kjo_2019_0105
crossref_citationtrail_10_3341_kjo_2019_0105
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2020-04-01
PublicationDateYYYYMMDD 2020-04-01
PublicationDate_xml – month: 04
  year: 2020
  text: 2020-04-01
  day: 01
PublicationDecade 2020
PublicationPlace Korea (South)
PublicationPlace_xml – name: Korea (South)
PublicationTitle Korean journal of ophthalmology
PublicationTitleAlternate Korean J Ophthalmol
PublicationYear 2020
Publisher The Korean Ophthalmological Society
대한안과학회
Publisher_xml – name: The Korean Ophthalmological Society
– name: 대한안과학회
References Manalastas (10.3341/kjo.2019.0105_ref18) 2017; 26
Spaide (10.3341/kjo.2019.0105_ref8) 2015; 133
Guo (10.3341/kjo.2019.0105_ref13) 2017; 237
Durbin (10.3341/kjo.2019.0105_ref24) 2017; 135
Saw (10.3341/kjo.2019.0105_ref4) 2005; 25
Sung (10.3341/kjo.2019.0105_ref10) 2018; 188
Balaratnasingam (10.3341/kjo.2019.0105_ref11) 2016; 123
Vurgese (10.3341/kjo.2019.0105_ref22) 2012; 7
Wang (10.3341/kjo.2019.0105_ref2) 1994; 35
Curtin (10.3341/kjo.2019.0105_ref6) 1977; 75
Carpineto (10.3341/kjo.2019.0105_ref15) 2016; 100
Amoroso (10.3341/kjo.2019.0105_ref20) 2018; 102
Lee (10.3341/kjo.2019.0105_ref19) 2018
Spaide (10.3341/kjo.2019.0105_ref23) 2015; 35
Wong (10.3341/kjo.2019.0105_ref3) 2000; 41
Hayashi (10.3341/kjo.2019.0105_ref5) 2010; 117
He (10.3341/kjo.2019.0105_ref21) 2019; 33
Katz (10.3341/kjo.2019.0105_ref1) 1997; 38
Lei (10.3341/kjo.2019.0105_ref17) 2017; 135
Al-Sheikh (10.3341/kjo.2019.0105_ref14) 2017; 101
Kwon (10.3341/kjo.2019.0105_ref12) 2017; 58
Pilotto (10.3341/kjo.2019.0105_ref9) 2018; 59
Lee (10.3341/kjo.2019.0105_ref25) 2015; 160
Rao (10.3341/kjo.2019.0105_ref26) 2016; 25
Ohno-Matsui (10.3341/kjo.2019.0105_ref7) 2003; 87
Corvi (10.3341/kjo.2019.0105_ref16) 2018; 186
References_xml – volume: 25
  start-page: e526
  year: 2016
  ident: 10.3341/kjo.2019.0105_ref26
  publication-title: J Glaucoma
  doi: 10.1097/IJG.0000000000000385
– volume: 26
  start-page: 851
  year: 2017
  ident: 10.3341/kjo.2019.0105_ref18
  publication-title: J Glaucoma
  doi: 10.1097/IJG.0000000000000768
– volume: 35
  start-page: 4344
  year: 1994
  ident: 10.3341/kjo.2019.0105_ref2
  publication-title: Invest Ophthalmol Vis Sci
– volume: 58
  start-page: 1637
  year: 2017
  ident: 10.3341/kjo.2019.0105_ref12
  publication-title: Invest Ophthalmol Vis Sci
  doi: 10.1167/iovs.16-21079
– volume: 35
  start-page: 2163
  year: 2015
  ident: 10.3341/kjo.2019.0105_ref23
  publication-title: Retina
  doi: 10.1097/IAE.0000000000000765
– volume: 123
  start-page: 2352
  year: 2016
  ident: 10.3341/kjo.2019.0105_ref11
  publication-title: Ophthalmology
  doi: 10.1016/j.ophtha.2016.07.008
– volume: 41
  start-page: 2486
  year: 2000
  ident: 10.3341/kjo.2019.0105_ref3
  publication-title: Invest Ophthalmol Vis Sci
– volume: 33
  start-page: 1494
  year: 2019
  ident: 10.3341/kjo.2019.0105_ref21
  publication-title: Eye (Lond)
  doi: 10.1038/s41433-019-0438-7
– volume: 25
  start-page: 381
  year: 2005
  ident: 10.3341/kjo.2019.0105_ref4
  publication-title: Ophthalmic Physiol Opt
  doi: 10.1111/j.1475-1313.2005.00298.x
– volume: 100
  start-page: 671
  year: 2016
  ident: 10.3341/kjo.2019.0105_ref15
  publication-title: Br J Ophthalmol
  doi: 10.1136/bjophthalmol-2015-307330
– volume: 135
  start-page: 370
  year: 2017
  ident: 10.3341/kjo.2019.0105_ref24
  publication-title: JAMA Ophthalmol
  doi: 10.1001/jamaophthalmol.2017.0080
– volume: 7
  start-page: e29692
  year: 2012
  ident: 10.3341/kjo.2019.0105_ref22
  publication-title: PLoS One
  doi: 10.1371/journal.pone.0029692
– volume: 38
  start-page: 334
  year: 1997
  ident: 10.3341/kjo.2019.0105_ref1
  publication-title: Invest Ophthalmol Vis Sci
– volume: 59
  start-page: 206
  year: 2018
  ident: 10.3341/kjo.2019.0105_ref9
  publication-title: Ophthalmic Res
  doi: 10.1159/000485463
– volume: 101
  start-page: 449
  year: 2017
  ident: 10.3341/kjo.2019.0105_ref14
  publication-title: Br J Ophthalmol
  doi: 10.1136/bjophthalmol-2016-308764
– volume: 75
  start-page: 67
  year: 1977
  ident: 10.3341/kjo.2019.0105_ref6
  publication-title: Trans Am Ophthalmol Soc
– year: 2018
  ident: 10.3341/kjo.2019.0105_ref19
  publication-title: Br J Ophthalmol
– volume: 117
  start-page: 1595
  year: 2010
  ident: 10.3341/kjo.2019.0105_ref5
  publication-title: Ophthalmology
  doi: 10.1016/j.ophtha.2009.11.003
– volume: 237
  start-page: 21
  year: 2017
  ident: 10.3341/kjo.2019.0105_ref13
  publication-title: Ophthalmologica
  doi: 10.1159/000453112
– volume: 188
  start-page: 81
  year: 2018
  ident: 10.3341/kjo.2019.0105_ref10
  publication-title: Am J Ophthalmol
  doi: 10.1016/j.ajo.2018.01.033
– volume: 87
  start-page: 570
  year: 2003
  ident: 10.3341/kjo.2019.0105_ref7
  publication-title: Br J Ophthalmol
  doi: 10.1136/bjo.87.5.570
– volume: 133
  start-page: 45
  year: 2015
  ident: 10.3341/kjo.2019.0105_ref8
  publication-title: JAMA Ophthalmol
  doi: 10.1001/jamaophthalmol.2014.3616
– volume: 186
  start-page: 25
  year: 2018
  ident: 10.3341/kjo.2019.0105_ref16
  publication-title: Am J Ophthalmol
  doi: 10.1016/j.ajo.2017.11.011
– volume: 135
  start-page: 1092
  year: 2017
  ident: 10.3341/kjo.2019.0105_ref17
  publication-title: JAMA Ophthalmol
  doi: 10.1001/jamaophthalmol.2017.3431
– volume: 102
  start-page: 821
  year: 2018
  ident: 10.3341/kjo.2019.0105_ref20
  publication-title: Br J Ophthalmol
  doi: 10.1136/bjophthalmol-2017-310569
– volume: 160
  start-page: 283
  year: 2015
  ident: 10.3341/kjo.2019.0105_ref25
  publication-title: Am J Ophthalmol
  doi: 10.1016/j.ajo.2015.05.015
SSID ssj0061307
Score 2.1874459
Snippet To analyze the repeatability of manual measurement of foveal avascular zone (FAZ) area in an optical coherence tomography angiography (OCTA) image in high...
Purpose: To analyze the repeatability of manual measurement of foveal avascular zone (FAZ) area in an opticalcoherence tomography angiography (OCTA) image in...
SourceID nrf
pubmedcentral
proquest
pubmed
crossref
SourceType Open Website
Open Access Repository
Aggregation Database
Index Database
Enrichment Source
StartPage 113
SubjectTerms Original
안과학
Title Repeatability of Manual Measurement of Foveal Avascular Zone Area in Optical Coherence Tomography Angiography Images in High Myopia
URI https://www.ncbi.nlm.nih.gov/pubmed/32233144
https://www.proquest.com/docview/2385270066
https://pubmed.ncbi.nlm.nih.gov/PMC7105788
https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002575674
Volume 34
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
ispartofPNX Korean Journal of Ophthalmology, 2020, 34(2), , pp.113-120
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9NAEB6RIlW9IN64QLQgxAkXP9b2-oBQhYhaJMOlERWXlfdVTFo7TVpEzvxxZvxICZQLJ1vel7Wzj_lmZ78BeGETkSmhlB8kKvB5HnJfGev8PBWaC6NtbggoFh_Tgyn_cJwcX1EK9R24vBbaUTyp6eJ078f56i1O-DeEOHERfj37Rrf4wnyPoj2O4CZuSinhsIKvDxRIS27jrJBFUOQ86ug2_y6-A9s4xOMYccbGTjWqF-46JfRPX8rfNqfJbbjVa5VsvxsGd-CGre_CdtGfm9-Dn6hn46LbcXKvWONYURIXKSuuTIT0ddJ8t1TP4J_KvjS1xWptyaqafZq3hm9GVzraS4LsqDnrKa_Zfn1SDe-HZ7hKLakIuZGwYtXMq_I-TCfvj94d-H34BV_H5PuGup0t89jkjkc8i0zsnEm0FkkuMq2DPMLpa9PQuMSGJbdBYA3mjhCWYpISOn4AWzX-5SNgxhrcCVNdckdXcWNV4kJguXOZjsNYKQ9eDV0tdc9NTiEyTiViFBKSRCFJEpIkIXnwcp193pFy_Cvjc5SbnOlKEo02PU8aOVtIBAuHEpFehnDKg2eDWCXOLTowKWvbXC4lqjMJHcynqQcPOzGv2xtGiQfZxgBYZ6AGN1Pq6mvL351RbGUhdv-75GPYiQj2tw5ET2DrYnFpn6JudKHGMEr8z-PWsjBuZ8AvP7YQmQ
linkProvider Scholars Portal
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Repeatability+of+Manual+Measurement+of+Foveal+Avascular+Zone+Area+in+Optical+Coherence+Tomography+Angiography+Images+in+High+Myopia&rft.jtitle=Korean+journal+of+ophthalmology&rft.au=Lee%2C+Jong+Ha&rft.au=Lee%2C+Min+Woo&rft.au=Baek%2C+Seung+Kook&rft.au=Lee%2C+Young+Hoon&rft.date=2020-04-01&rft.pub=The+Korean+Ophthalmological+Society&rft.issn=1011-8942&rft.eissn=2092-9382&rft.volume=34&rft.issue=2&rft.spage=113&rft.epage=120&rft_id=info:doi/10.3341%2Fkjo.2019.0105&rft_id=info%3Apmid%2F32233144&rft.externalDocID=PMC7105788
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1011-8942&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1011-8942&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1011-8942&client=summon