Comparative Evaluation of 4 Commercially Available ELISA Kits for Measuring Adalimumab and Anti-adalimumab Antibodies

Therapeutic drug monitoring of tumor necrosis factor inhibitors, such as adalimumab (ADM), is increasingly being performed for the management of autoimmune diseases. However, there can be significant variation in drug and antibody concentrations obtained by different assay methods. The aim of this s...

Full description

Saved in:
Bibliographic Details
Published inTherapeutic drug monitoring Vol. 42; no. 6; p. 821
Main Authors Sam, Melissa Joyce, Connor, Susan Jane, Ng, Watson Wa-Sang, Toong, Catherine Mei-Ling
Format Journal Article
LanguageEnglish
Published United States 01.12.2020
Online AccessGet more information

Cover

Loading…
More Information
Summary:Therapeutic drug monitoring of tumor necrosis factor inhibitors, such as adalimumab (ADM), is increasingly being performed for the management of autoimmune diseases. However, there can be significant variation in drug and antibody concentrations obtained by different assay methods. The aim of this study was to compare the performance of 4 enzyme-linked immunosorbent assay (ELISA) kits for measuring ADM and anti-ADM antibodies. Dilutions of ADM or anti-ADM spiked sera were assessed for recovery rate and precision using the following 4 kits: LISA-Tracker (Theradiag, Croissy-Beaubourg, France), Promonitor (Grifols, Barcelona, Spain), Ridascreen (R-Biopharm, Darmstadt, Germany), and Shikari (Matriks Biotek, Gölbaşi/Ankara Turkey). Interference samples were also assessed. At the therapeutic concentration, ADM detection was comparable among the 4 ELISA kits. Lisa-Tracker and Shikari kits produced low-range false positive results in normal sera. Infliximab and etanercept caused false positives in Lisa-Tracker and Shikari kits. Anti-ADM antibody ELISA kits performed differently with spiked samples because of different measuring units and ranges. Ridascreen and Shikari kits were dose responsive across the entire standard curve and correlated well with each other (r = 0.997). Cross reactivity was observed in rheumatoid factor positive sera tested on the Promonitor anti-ADM kit. All ADM kits tested were dose responsive within the therapeutic range and correlated well. The significance of observed low-range false positives and cross reactivity with infliximab in LISA-Tracker and Shikari kits is dependent on the indications received for testing in the laboratory. Anti-ADM ELISA kits produced varied results for spiked sera; however, they showed good precision. Inter-kit variability suggested that anti-ADM levels should be compared only when using the same method.
ISSN:1536-3694
DOI:10.1097/FTD.0000000000000795