Remedy for repeated implant retained denture fracture-a challenging case report
The most common site of fracture in a maxillary or a mandibular complete denture is along an anteroposterior line that coincides with the labial notch in in the denture which used to provide the frenum relief. Osseointegrated implants have been a boon to the patients who are completelly edentulous a...
Saved in:
Published in | Journal of clinical and diagnostic research Vol. 8; no. 11; pp. ZD14 - ZD15 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
India
JCDR Research and Publications Private Limited
01.11.2014
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | The most common site of fracture in a maxillary or a mandibular complete denture is along an anteroposterior line that coincides with the labial notch in in the denture which used to provide the frenum relief. Osseointegrated implants have been a boon to the patients who are completelly edentulous and are not satisfied with the conventional removable complete denture approach.Implant supported dentures have proven to provide superior retention and support for removable complete dentures. Nevertheless, fracture of the denture bases is a common complication of implant-supported mandibular overlay dentures,ecspecially when the artificial denture is opposing natural dentition. This article describes and illustrates a method of reinforcing implant-supported mandibular overdentures to overcome this problem. |
---|---|
AbstractList | The most common site of fracture in a maxillary or a mandibular complete denture is along an anteroposterior line that coincides with the labial notch in in the denture which used to provide the frenum relief. Osseointegrated implants have been a boon to the patients who are completelly edentulous and are not satisfied with the conventional removable complete denture approach.Implant supported dentures have proven to provide superior retention and support for removable complete dentures. Nevertheless, fracture of the denture bases is a common complication of implant-supported mandibular overlay dentures,ecspecially when the artificial denture is opposing natural dentition. This article describes and illustrates a method of reinforcing implant-supported mandibular overdentures to overcome this problem. |
Author | Metta, Kiran Kumar Charry N, Sudheer B, Chittaranjan Avinash C K, Anulekha Reddy M, Ramu |
Author_xml | – sequence: 1 givenname: Ramu surname: Reddy M fullname: Reddy M, Ramu organization: Professor, Department of Prosthodontics, Kamineni Institute of Dental sciences , Narketpally, Nalgonda, Andhra Pradesh, India – sequence: 2 givenname: Kiran Kumar surname: Metta fullname: Metta, Kiran Kumar organization: Reader, Department of Conservative Dentistry and Endodontics, MIDSR Dental College and Hospital , Latur, Maharastra, India – sequence: 3 givenname: Sudheer surname: Charry N fullname: Charry N, Sudheer organization: Professor, Department of Prosthodontics, Kamineni Institute of Dental Sciences , Nalgonda, Andhra Pradesh, India – sequence: 4 givenname: Anulekha surname: Avinash C K fullname: Avinash C K, Anulekha organization: Reader, Department of Prosthodontics, Kamineni Institute of Dental Sciences , Nalgonda, Andhra Pradesh, India – sequence: 5 givenname: Chittaranjan surname: B fullname: B, Chittaranjan organization: Professor and HOD, Department of Prosthodontics, Kamineni Institute of Dental Sciences , Nalgonda, Andhra Pradesh, India |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/25584333$$D View this record in MEDLINE/PubMed |
BookMark | eNo9kNtqwkAQhpdiqdb2CQolLxDdU_ZwWezJIgjSgnfLZA82EpOwiRe-fZPaejUzP3z_wHeLRlVdeYQeCJ5JJfD8Y_G8mVNM-FxpomcZEeoKTbCWLJVYb0doQinXqVR0O0a3bbvHWAjBxA0a0yxTnDE2QeuNP3h3SkIdk-gbD513SXFoSqi6PuigqPrA-ao7Rp-ECHZYUkjsN5Slr3ZFtUsstH6g69jdoesAZevv_-YUfb2-fC7e09X6bbl4WqW2f9ullDguiRd5zr0D6_qTaBswpRm3nHAurMuDBEllpgVmCgvNMkUzyiVVwbEpWp57XQ1708TiAPFkaijMb1DHnYHYFbb0xgagRFLnIBAOVOjgqcuszIEFiS3vu9i5y8a6baMPlz6CzaDaDKrNoNoMqs2guqcez1RzzHuFF-bfLfsByH98Zw |
ContentType | Journal Article |
DBID | NPM AAYXX CITATION DOA |
DOI | 10.7860/JCDR/2014/8919.5168 |
DatabaseName | PubMed CrossRef DOAJ Directory of Open Access Journals |
DatabaseTitle | PubMed CrossRef |
DatabaseTitleList | PubMed |
Database_xml | – sequence: 1 dbid: DOA name: DOAJ Directory of Open Access Journals url: https://www.doaj.org/ sourceTypes: Open Website – sequence: 2 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 0973-709X |
EndPage | ZD15 |
ExternalDocumentID | oai_doaj_org_article_cfa2172ddaf14a269fe2d5c7ba3f70c4 10_7860_JCDR_2014_8919_5168 25584333 |
Genre | Case Reports |
GroupedDBID | --- 2WC 5VS ABDBF ADBBV ALMA_UNASSIGNED_HOLDINGS BAWUL BCNDV DIK E3Z EBD EOJEC ESX GROUPED_DOAJ GX1 HYE KQ8 M~E NPM OBODZ OK1 P6G RNS RPM TR2 TUS ~8M AAYXX CITATION |
ID | FETCH-LOGICAL-c333t-21d471e6bb4edacd1d419cf02254c41446cdbf7a7275960380693582524728fd3 |
IEDL.DBID | DOA |
ISSN | 2249-782X |
IngestDate | Thu Jul 04 21:00:02 EDT 2024 Fri Aug 23 08:39:26 EDT 2024 Sat Sep 28 08:36:17 EDT 2024 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 11 |
Keywords | Repeated fractured dentures Fractures Implant over denture ball attachments Implant overdenture Reinforcements of dentures |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c333t-21d471e6bb4edacd1d419cf02254c41446cdbf7a7275960380693582524728fd3 |
OpenAccessLink | https://doaj.org/article/cfa2172ddaf14a269fe2d5c7ba3f70c4 |
PMID | 25584333 |
ParticipantIDs | doaj_primary_oai_doaj_org_article_cfa2172ddaf14a269fe2d5c7ba3f70c4 crossref_primary_10_7860_JCDR_2014_8919_5168 pubmed_primary_25584333 |
PublicationCentury | 2000 |
PublicationDate | 2014-11-01 |
PublicationDateYYYYMMDD | 2014-11-01 |
PublicationDate_xml | – month: 11 year: 2014 text: 2014-11-01 day: 01 |
PublicationDecade | 2010 |
PublicationPlace | India |
PublicationPlace_xml | – name: India |
PublicationTitle | Journal of clinical and diagnostic research |
PublicationTitleAlternate | J Clin Diagn Res |
PublicationYear | 2014 |
Publisher | JCDR Research and Publications Private Limited |
Publisher_xml | – name: JCDR Research and Publications Private Limited |
SSID | ssj0066636 |
Score | 1.996732 |
Snippet | The most common site of fracture in a maxillary or a mandibular complete denture is along an anteroposterior line that coincides with the labial notch in in... |
SourceID | doaj crossref pubmed |
SourceType | Open Website Aggregation Database Index Database |
StartPage | ZD14 |
SubjectTerms | fractures implant over denture ball attachments implant overdenture reinforcements of dentures repeated fractured dentures |
Title | Remedy for repeated implant retained denture fracture-a challenging case report |
URI | https://www.ncbi.nlm.nih.gov/pubmed/25584333 https://doaj.org/article/cfa2172ddaf14a269fe2d5c7ba3f70c4 |
Volume | 8 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1NS8QwEA3iQbyI365f5ODRuE2apMlRd10XQYVFYW8ln8dVZD34751p6iJevHgpbWhD-qbkvSHNG0IuohPO6GiYVt4zGavMbOSSJRmdtNk3uasS8fCopy_yfq7mP0p94T9hxR64ADcM2WENpRhd5tIJbXMSUYXGuzo3VShOoFx9J1NlDgZN3hUHBH6yDDhwXvyGGqOr4f1oPIOUn8uhsdxeKY4uqz84qbPu_yUyO7KZbJOtXiXS6zK6HbKWFrtk46FfB98jT7MET31SUJwUJDTMpylSNPoFnKAB031oGHeEkugEd0LBCbumo752ChAWHQGB0SLA98nL5PZ5NGV9aQQW6rpeMsEjsErS3ssUXYhwyW3IQMhKBok5Xog-Nw7UiYIcpTaVxgVPoYRshMmxPiDri9dFOiK00cmCSvKVy14qk60SScgYUU5pk-SAXH6D074VB4wWMgfEskUsW8SyRSxbxHJAbhDA1a1oX901QFDbPqjtX0EdkMMC_6obyHyMhFc__o_uT8gmDrpsKTwl68v3j3QG2mLpz7vPCI53c_4FOwjKCw |
link.rule.ids | 315,786,790,870,2115,27957,27958 |
linkProvider | Directory of Open Access Journals |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Remedy+for+Repeated+Implant+Retained+Denture+Fracture-A+Challenging+Case+Report&rft.jtitle=Journal+of+clinical+and+diagnostic+research&rft.au=Ramu+Reddy.M&rft.au=Kiran+Kumar+Metta&rft.au=Sudheer+Charry.N&rft.au=Anulekha+Avinash+.C.K&rft.date=2014-11-01&rft.pub=JCDR+Research+and+Publications+Private+Limited&rft.issn=2249-782X&rft.eissn=0973-709X&rft.volume=8&rft.issue=11&rft.spage=ZD14&rft.epage=ZD15&rft_id=info:doi/10.7860%2FJCDR%2F2014%2F8919.5168&rft.externalDBID=DOA&rft.externalDocID=oai_doaj_org_article_cfa2172ddaf14a269fe2d5c7ba3f70c4 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2249-782X&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2249-782X&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2249-782X&client=summon |