Timing optimization utilizing order statistics and multichannel digital silicon photomultipliers
We present an optimization technique utilizing order statistics with a multichannel digital silicon photomultiplier (MD-SiPM) for timing measurements. Accurate timing measurements are required by 3D rangefinding and time-of-flight positron emission tomography, to name a few applications. We have dem...
Saved in:
Published in | Optics letters Vol. 39; no. 3; p. 552 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
United States
01.02.2014
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Abstract | We present an optimization technique utilizing order statistics with a multichannel digital silicon photomultiplier (MD-SiPM) for timing measurements. Accurate timing measurements are required by 3D rangefinding and time-of-flight positron emission tomography, to name a few applications. We have demonstrated the ability of the MD-SiPM to detect multiple photons, and we verified the advantage of detecting multiple photons assuming incoming photons follow a Gaussian distribution. We have also shown the advantage of utilizing multiple timestamps for estimating time-of-arrivals more accurately. This estimation technique can be widely available in various applications, which have a certain probability density function of incoming photons, such as a scintillator or a laser source. |
---|---|
AbstractList | We present an optimization technique utilizing order statistics with a multichannel digital silicon photomultiplier (MD-SiPM) for timing measurements. Accurate timing measurements are required by 3D rangefinding and time-of-flight positron emission tomography, to name a few applications. We have demonstrated the ability of the MD-SiPM to detect multiple photons, and we verified the advantage of detecting multiple photons assuming incoming photons follow a Gaussian distribution. We have also shown the advantage of utilizing multiple timestamps for estimating time-of-arrivals more accurately. This estimation technique can be widely available in various applications, which have a certain probability density function of incoming photons, such as a scintillator or a laser source. |
Author | Charbon, Edoardo Venialgo, Esteban Mandai, Shingo |
Author_xml | – sequence: 1 givenname: Shingo surname: Mandai fullname: Mandai, Shingo – sequence: 2 givenname: Esteban surname: Venialgo fullname: Venialgo, Esteban – sequence: 3 givenname: Edoardo surname: Charbon fullname: Charbon, Edoardo |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/24487863$$D View this record in MEDLINE/PubMed |
BookMark | eNo1jz1PwzAYhC0Eoh-wMSP_gQTbr53EI6qgIEXqUubi-KM1Spwodgb664kKTHd6dHfSrdB16INF6IGSnELBn3Z1DjInhAjBrtCSCpAZLyVfoFWMXzMvSoBbtGCcV2VVwBJ97n3nwxH3Q5rNWSXfBzwl3_rzBY_GjjimmcfkdcQqGNxN7exPKgTbYuOPPqkWx7mi5-5w6lN_SQytt2O8QzdOtdHe_-kafby-7DdvWb3bvm-e60wD4ylTRmhCTWMpMHANU6yS4EBZVzpTSUep0kAclUJoV4qykopA4aiwhWRSc7ZGj7-7w9R01hyG0Xdq_D78X2U_qTpYVA |
CitedBy_id | crossref_primary_10_1364_OE_507975 crossref_primary_10_1364_OE_408800 crossref_primary_10_1109_JSTQE_2022_3161089 crossref_primary_10_1109_LPT_2014_2327118 crossref_primary_10_1088_1748_0221_11_11_P11004 crossref_primary_10_1016_j_nima_2015_10_078 crossref_primary_10_1088_1361_6560_abee56 crossref_primary_10_1088_1742_6596_587_1_012068 |
ContentType | Journal Article |
DBID | CGR CUY CVF ECM EIF NPM |
DOI | 10.1364/OL.39.000552 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
Discipline | Physics |
EISSN | 1539-4794 |
ExternalDocumentID | 24487863 |
Genre | Research Support, Non-U.S. Gov't Journal Article |
GroupedDBID | --- -~X .DC 123 29N 4.4 53G 8SL AAWJZ ACBEA ACGFO AENEX AKGWG ALMA_UNASSIGNED_HOLDINGS ATHME AYPRP AZSQR AZYMN CGR CS3 CUY CVF DSZJF DU5 EBS ECM EIF EJD F5P NPM ODPQJ OFLFD OPJBK OPLUZ P2P RNS ROL ROP ROS SJN TAE TN5 TR6 UCJ WH7 Y7S YNT |
ID | FETCH-LOGICAL-c324t-ad5c01dbe1323fb2a2893f3aef7fd89f11ac30f1955cf75789a036f15e6929c42 |
IngestDate | Thu May 23 23:19:38 EDT 2024 |
IsDoiOpenAccess | false |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 3 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c324t-ad5c01dbe1323fb2a2893f3aef7fd89f11ac30f1955cf75789a036f15e6929c42 |
PMID | 24487863 |
ParticipantIDs | pubmed_primary_24487863 |
PublicationCentury | 2000 |
PublicationDate | 2014-Feb-01 |
PublicationDateYYYYMMDD | 2014-02-01 |
PublicationDate_xml | – month: 02 year: 2014 text: 2014-Feb-01 day: 01 |
PublicationDecade | 2010 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Optics letters |
PublicationTitleAlternate | Opt Lett |
PublicationYear | 2014 |
SSID | ssj0006733 |
Score | 2.2245967 |
Snippet | We present an optimization technique utilizing order statistics with a multichannel digital silicon photomultiplier (MD-SiPM) for timing measurements. Accurate... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 552 |
SubjectTerms | Optical Devices Photons Silicon Time Factors |
Title | Timing optimization utilizing order statistics and multichannel digital silicon photomultipliers |
URI | https://www.ncbi.nlm.nih.gov/pubmed/24487863 |
Volume | 39 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3NT9swFLcGE9IuExsfG1_yYbcqUNex4xwRKkITXQ8riBuzHbsglaZSc-pfv_ccp406QLCLE9n5kt8vLz-_vA9CfjhuMyGcTphQMkm5VYnKoTHaSO4ckzqkUhr8klc36c87cbdyGwvRJZU5tYtn40r-R6rQB3LFKNl3SHZ5UeiAfZAvtCBhaN8mYyzJNe6U8No_xXjKDtxu8rgI3ZhVE20FVSsZc3AgxGjfqcO_M2OsGdKZwymwLu7MHsqqjC6Gj9E1vmGuw1m4xiSE_yyJ-AANEcEh4Deassqm_xZ9-CbjYIftA5DMCoT4g9_ECiJFCQAt25YHljbOyvjhaLRljqa5tK1O69xEETa8pRtFnar2H53NZQoTPbw-5Zg6tLt2GMz47CnID4iIylStDl8fXcug3QxtkA3YYHFUtOjEr7XMOI8BEfAgZ-3HwETR8dS1RUcgH6Nt8jmuGuh5DYEv5IObfiVbwXvXznfInxoItA0EugQCDUCgKyBQEBptA4FGINAIBLoOhF1yc9kfXVwlsXRGYoEhV4kuhO2ywjjGe9ybnoZ1NfdcO5_5QuWeMW1517NcCOuxpEGugcp4JpwEvmzT3h7ZnJZT941QLbOe8LlXVnmkcziuNJPGCVOkuftO9uupuZ_V-VHum0k7eHHkkHxaAeqIfPTwQrpjYHeVOQni-QtAkFXW |
link.rule.ids | 786 |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Timing+optimization+utilizing+order+statistics+and+multichannel+digital+silicon+photomultipliers&rft.jtitle=Optics+letters&rft.au=Mandai%2C+Shingo&rft.au=Venialgo%2C+Esteban&rft.au=Charbon%2C+Edoardo&rft.date=2014-02-01&rft.eissn=1539-4794&rft.volume=39&rft.issue=3&rft.spage=552&rft_id=info:doi/10.1364%2FOL.39.000552&rft_id=info%3Apmid%2F24487863&rft_id=info%3Apmid%2F24487863&rft.externalDocID=24487863 |