Timing optimization utilizing order statistics and multichannel digital silicon photomultipliers

We present an optimization technique utilizing order statistics with a multichannel digital silicon photomultiplier (MD-SiPM) for timing measurements. Accurate timing measurements are required by 3D rangefinding and time-of-flight positron emission tomography, to name a few applications. We have dem...

Full description

Saved in:
Bibliographic Details
Published inOptics letters Vol. 39; no. 3; p. 552
Main Authors Mandai, Shingo, Venialgo, Esteban, Charbon, Edoardo
Format Journal Article
LanguageEnglish
Published United States 01.02.2014
Subjects
Online AccessGet more information

Cover

Loading…
Abstract We present an optimization technique utilizing order statistics with a multichannel digital silicon photomultiplier (MD-SiPM) for timing measurements. Accurate timing measurements are required by 3D rangefinding and time-of-flight positron emission tomography, to name a few applications. We have demonstrated the ability of the MD-SiPM to detect multiple photons, and we verified the advantage of detecting multiple photons assuming incoming photons follow a Gaussian distribution. We have also shown the advantage of utilizing multiple timestamps for estimating time-of-arrivals more accurately. This estimation technique can be widely available in various applications, which have a certain probability density function of incoming photons, such as a scintillator or a laser source.
AbstractList We present an optimization technique utilizing order statistics with a multichannel digital silicon photomultiplier (MD-SiPM) for timing measurements. Accurate timing measurements are required by 3D rangefinding and time-of-flight positron emission tomography, to name a few applications. We have demonstrated the ability of the MD-SiPM to detect multiple photons, and we verified the advantage of detecting multiple photons assuming incoming photons follow a Gaussian distribution. We have also shown the advantage of utilizing multiple timestamps for estimating time-of-arrivals more accurately. This estimation technique can be widely available in various applications, which have a certain probability density function of incoming photons, such as a scintillator or a laser source.
Author Charbon, Edoardo
Venialgo, Esteban
Mandai, Shingo
Author_xml – sequence: 1
  givenname: Shingo
  surname: Mandai
  fullname: Mandai, Shingo
– sequence: 2
  givenname: Esteban
  surname: Venialgo
  fullname: Venialgo, Esteban
– sequence: 3
  givenname: Edoardo
  surname: Charbon
  fullname: Charbon, Edoardo
BackLink https://www.ncbi.nlm.nih.gov/pubmed/24487863$$D View this record in MEDLINE/PubMed
BookMark eNo1jz1PwzAYhC0Eoh-wMSP_gQTbr53EI6qgIEXqUubi-KM1Spwodgb664kKTHd6dHfSrdB16INF6IGSnELBn3Z1DjInhAjBrtCSCpAZLyVfoFWMXzMvSoBbtGCcV2VVwBJ97n3nwxH3Q5rNWSXfBzwl3_rzBY_GjjimmcfkdcQqGNxN7exPKgTbYuOPPqkWx7mi5-5w6lN_SQytt2O8QzdOtdHe_-kafby-7DdvWb3bvm-e60wD4ylTRmhCTWMpMHANU6yS4EBZVzpTSUep0kAclUJoV4qykopA4aiwhWRSc7ZGj7-7w9R01hyG0Xdq_D78X2U_qTpYVA
CitedBy_id crossref_primary_10_1364_OE_507975
crossref_primary_10_1364_OE_408800
crossref_primary_10_1109_JSTQE_2022_3161089
crossref_primary_10_1109_LPT_2014_2327118
crossref_primary_10_1088_1748_0221_11_11_P11004
crossref_primary_10_1016_j_nima_2015_10_078
crossref_primary_10_1088_1361_6560_abee56
crossref_primary_10_1088_1742_6596_587_1_012068
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.1364/OL.39.000552
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Physics
EISSN 1539-4794
ExternalDocumentID 24487863
Genre Research Support, Non-U.S. Gov't
Journal Article
GroupedDBID ---
-~X
.DC
123
29N
4.4
53G
8SL
AAWJZ
ACBEA
ACGFO
AENEX
AKGWG
ALMA_UNASSIGNED_HOLDINGS
ATHME
AYPRP
AZSQR
AZYMN
CGR
CS3
CUY
CVF
DSZJF
DU5
EBS
ECM
EIF
EJD
F5P
NPM
ODPQJ
OFLFD
OPJBK
OPLUZ
P2P
RNS
ROL
ROP
ROS
SJN
TAE
TN5
TR6
UCJ
WH7
Y7S
YNT
ID FETCH-LOGICAL-c324t-ad5c01dbe1323fb2a2893f3aef7fd89f11ac30f1955cf75789a036f15e6929c42
IngestDate Thu May 23 23:19:38 EDT 2024
IsDoiOpenAccess false
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 3
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c324t-ad5c01dbe1323fb2a2893f3aef7fd89f11ac30f1955cf75789a036f15e6929c42
PMID 24487863
ParticipantIDs pubmed_primary_24487863
PublicationCentury 2000
PublicationDate 2014-Feb-01
PublicationDateYYYYMMDD 2014-02-01
PublicationDate_xml – month: 02
  year: 2014
  text: 2014-Feb-01
  day: 01
PublicationDecade 2010
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Optics letters
PublicationTitleAlternate Opt Lett
PublicationYear 2014
SSID ssj0006733
Score 2.2245967
Snippet We present an optimization technique utilizing order statistics with a multichannel digital silicon photomultiplier (MD-SiPM) for timing measurements. Accurate...
SourceID pubmed
SourceType Index Database
StartPage 552
SubjectTerms Optical Devices
Photons
Silicon
Time Factors
Title Timing optimization utilizing order statistics and multichannel digital silicon photomultipliers
URI https://www.ncbi.nlm.nih.gov/pubmed/24487863
Volume 39
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3NT9swFLcGE9IuExsfG1_yYbcqUNex4xwRKkITXQ8riBuzHbsglaZSc-pfv_ccp406QLCLE9n5kt8vLz-_vA9CfjhuMyGcTphQMkm5VYnKoTHaSO4ckzqkUhr8klc36c87cbdyGwvRJZU5tYtn40r-R6rQB3LFKNl3SHZ5UeiAfZAvtCBhaN8mYyzJNe6U8No_xXjKDtxu8rgI3ZhVE20FVSsZc3AgxGjfqcO_M2OsGdKZwymwLu7MHsqqjC6Gj9E1vmGuw1m4xiSE_yyJ-AANEcEh4Deassqm_xZ9-CbjYIftA5DMCoT4g9_ECiJFCQAt25YHljbOyvjhaLRljqa5tK1O69xEETa8pRtFnar2H53NZQoTPbw-5Zg6tLt2GMz47CnID4iIylStDl8fXcug3QxtkA3YYHFUtOjEr7XMOI8BEfAgZ-3HwETR8dS1RUcgH6Nt8jmuGuh5DYEv5IObfiVbwXvXznfInxoItA0EugQCDUCgKyBQEBptA4FGINAIBLoOhF1yc9kfXVwlsXRGYoEhV4kuhO2ywjjGe9ybnoZ1NfdcO5_5QuWeMW1517NcCOuxpEGugcp4JpwEvmzT3h7ZnJZT941QLbOe8LlXVnmkcziuNJPGCVOkuftO9uupuZ_V-VHum0k7eHHkkHxaAeqIfPTwQrpjYHeVOQni-QtAkFXW
link.rule.ids 786
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Timing+optimization+utilizing+order+statistics+and+multichannel+digital+silicon+photomultipliers&rft.jtitle=Optics+letters&rft.au=Mandai%2C+Shingo&rft.au=Venialgo%2C+Esteban&rft.au=Charbon%2C+Edoardo&rft.date=2014-02-01&rft.eissn=1539-4794&rft.volume=39&rft.issue=3&rft.spage=552&rft_id=info:doi/10.1364%2FOL.39.000552&rft_id=info%3Apmid%2F24487863&rft_id=info%3Apmid%2F24487863&rft.externalDocID=24487863