Development of high-energy and high-resolution X-ray CT
This paper introduces a novel high-energy and high-resolution X-ray computed tomography system called eXTRACT. Preliminary experimental testing was performed of the penetration capability and structural resolution achieved by the system, and the results are reported. The X-ray source realized both b...
Saved in:
Published in | Precision engineering Vol. 54; pp. 276 - 283 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
Elsevier Inc
01.10.2018
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | This paper introduces a novel high-energy and high-resolution X-ray computed tomography system called eXTRACT. Preliminary experimental testing was performed of the penetration capability and structural resolution achieved by the system, and the results are reported. The X-ray source realized both bremsstrahlung X-rays with an average energy of 1 MeV and the focal size of 100 μm at the same time. Using 970 physical channels of high-energy X-ray line detectors and a modified offset scanning method, the CT reconstruction of 4286 by 4286 pixels were achieved for a single sinogram from a single fan beam scanning. The performance was further investigated by scanning several material standards. The penetration capability of 400 mm or more, represented by a longitudinal dimension of the object, was recorded in case of scanning aluminum. The structural resolution of 0.1 mm by 0.1 mm line and space structure under the field of view size of 300 mm in the diameter is also verified.
•The developed eXTRACT records its structural resolution performance of 0.1 mm in the field of view with 300 mm in the diameter.•The penetration capability demonstrates 400 mm or more for aluminum material.•The averaged X-ray energy of 1 MeV is experimentally verified.•The performance exceeds that of existing high energy X-ray CT with linac at least 4-times for the structural resolution while the penetration capability comparable. |
---|---|
AbstractList | This paper introduces a novel high-energy and high-resolution X-ray computed tomography system called eXTRACT. Preliminary experimental testing was performed of the penetration capability and structural resolution achieved by the system, and the results are reported. The X-ray source realized both bremsstrahlung X-rays with an average energy of 1 MeV and the focal size of 100 μm at the same time. Using 970 physical channels of high-energy X-ray line detectors and a modified offset scanning method, the CT reconstruction of 4286 by 4286 pixels were achieved for a single sinogram from a single fan beam scanning. The performance was further investigated by scanning several material standards. The penetration capability of 400 mm or more, represented by a longitudinal dimension of the object, was recorded in case of scanning aluminum. The structural resolution of 0.1 mm by 0.1 mm line and space structure under the field of view size of 300 mm in the diameter is also verified.
•The developed eXTRACT records its structural resolution performance of 0.1 mm in the field of view with 300 mm in the diameter.•The penetration capability demonstrates 400 mm or more for aluminum material.•The averaged X-ray energy of 1 MeV is experimentally verified.•The performance exceeds that of existing high energy X-ray CT with linac at least 4-times for the structural resolution while the penetration capability comparable. |
Author | Abe, Makoto Takatsuji, Toshiyuki Sato, Katsutoshi |
Author_xml | – sequence: 1 givenname: Katsutoshi surname: Sato fullname: Sato, Katsutoshi organization: Hitachi Ltd., Saiwai-cho 1-1, Hitachi, Ibaraki, 317-8511, Japan – sequence: 2 givenname: Makoto surname: Abe fullname: Abe, Makoto email: makoto.abe@aist.go.jp organization: National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki, 305-8563, Japan – sequence: 3 givenname: Toshiyuki orcidid: 0000-0002-4644-5158 surname: Takatsuji fullname: Takatsuji, Toshiyuki organization: National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki, 305-8563, Japan |
BookMark | eNqNkMFKAzEQhoNUsK2-w-I962STTXa9SatVKHip4C3EZNKmtNmSrIW-vVvqwaOn4R_4_hm-CRnFLiIh9wxKBkw-bMtDQhtyGNZxXVbAmhJkCSCuyJg1itOKq2pExsAEo5LX7Q2Z5LwFANWAGBM1xyPuusMeY190vtiE9YZixLQ-FSa6S06Yu913PxwpPmkyp2K2uiXX3uwy3v3OKfl4eV7NXunyffE2e1pSyyvR09YJ0SjWOODculZyg5Y5VisP3nvVtAI542CtEbX6apnkbSuF4MxDbdE4PiWPl16bupwTen1IYW_SSTPQZwV6q_8q0GcFGqQeFAzw_ALj8OExYNLZBowWXRiQXrsu_KfmB4O-bR0 |
CitedBy_id | crossref_primary_10_1088_1361_6633_ac43f6 crossref_primary_10_1007_s11517_020_02246_1 crossref_primary_10_1016_j_cirpj_2023_10_004 |
Cites_doi | 10.1016/B978-0-444-53632-7.00604-3 10.1259/0007-1285-46-552-1023 10.1016/j.cirp.2011.05.006 10.1109/23.212333 10.1016/j.cirp.2014.05.011 |
ContentType | Journal Article |
Copyright | 2018 Elsevier Inc. |
Copyright_xml | – notice: 2018 Elsevier Inc. |
DBID | AAYXX CITATION |
DOI | 10.1016/j.precisioneng.2018.06.004 |
DatabaseName | CrossRef |
DatabaseTitle | CrossRef |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
EISSN | 1873-2372 |
EndPage | 283 |
ExternalDocumentID | 10_1016_j_precisioneng_2018_06_004 S0141635918303623 |
GroupedDBID | --K --M .~1 0R~ 123 1B1 1~. 1~5 29O 4.4 457 4G. 5VS 7-5 71M 8P~ 9JN AABXZ AACTN AAEDT AAEDW AAEPC AAIAV AAIKJ AAKOC AALRI AAOAW AAQFI AAQXK AAXUO ABFNM ABJNI ABMAC ABXDB ABXRA ABYKQ ACDAQ ACGFS ACNNM ACRLP ADBBV ADEZE ADMUD ADTZH AEBSH AECPX AEKER AEZYN AFKWA AFRZQ AFTJW AGHFR AGUBO AGYEJ AHHHB AHJVU AIEXJ AIKHN AITUG AJBFU AJOXV ALMA_UNASSIGNED_HOLDINGS AMFUW AMRAJ ASPBG AVWKF AXJTR AZFZN BJAXD BKOJK BLXMC CS3 EBS EFJIC EFLBG EJD EO8 EO9 EP2 EP3 FDB FEDTE FGOYB FIRID FNPLU FYGXN G-2 G-Q GBLVA HVGLF HZ~ IHE J1W JJJVA KOM LY7 M41 MAGPM MO0 N9A O-L O9- OAUVE OZT P-8 P-9 P2P PC. Q38 R2- RIG RNS ROL RPZ SDF SDG SDP SES SET SEW SPC SPCBC SSM SST SSZ T5K TN5 UHS WH7 WUQ XPP ZMT ~G- AAXKI AAYXX AFJKZ CITATION |
ID | FETCH-LOGICAL-c324t-9d448718d033cd963aec1d157f0fff7894e3130cca457b91639964431f05cead3 |
IEDL.DBID | AIKHN |
ISSN | 0141-6359 |
IngestDate | Thu Sep 26 19:39:37 EDT 2024 Fri Feb 23 02:23:47 EST 2024 |
IsPeerReviewed | true |
IsScholarly | true |
Keywords | High-resolution X-ray Computed tomography High-energy |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c324t-9d448718d033cd963aec1d157f0fff7894e3130cca457b91639964431f05cead3 |
ORCID | 0000-0002-4644-5158 |
PageCount | 8 |
ParticipantIDs | crossref_primary_10_1016_j_precisioneng_2018_06_004 elsevier_sciencedirect_doi_10_1016_j_precisioneng_2018_06_004 |
PublicationCentury | 2000 |
PublicationDate | October 2018 2018-10-00 |
PublicationDateYYYYMMDD | 2018-10-01 |
PublicationDate_xml | – month: 10 year: 2018 text: October 2018 |
PublicationDecade | 2010 |
PublicationTitle | Precision engineering |
PublicationYear | 2018 |
Publisher | Elsevier Inc |
Publisher_xml | – name: Elsevier Inc |
References | Kruth (bib2) 2011; 60 Ambrose, Hounsfield (bib4) 1973; 46 Savio (bib1) 2007; 56–2 (Last accessed on May 2, 2018). 29,71,107 (Last accessed on May 2, 2018). Yamada (bib16) 2014; 8 NIST Physical Measurement Laboratory, XCOM: photon cross sections database US Patent, US 6,327,328 B1, Computerized tomography system, K, Satoh et. al. 2001. . Reimers, Gobbels (bib5) 1983; 41 bib9 De Chiffre (bib3) 2014; 63 (in Japanese) (Last accessed on May 2, 2018). Izumi (bib11) 1993; 40–2 Abe, Fujimoto, Sato, Sato, Takatsuji (bib14) 2015 10.1016/j.precisioneng.2018.06.004_bib6 10.1016/j.precisioneng.2018.06.004_bib8 10.1016/j.precisioneng.2018.06.004_bib7 Savio (10.1016/j.precisioneng.2018.06.004_bib1) 2007; 56–2 Kruth (10.1016/j.precisioneng.2018.06.004_bib2) 2011; 60 Reimers (10.1016/j.precisioneng.2018.06.004_bib5) 1983; 41 10.1016/j.precisioneng.2018.06.004_bib15 De Chiffre (10.1016/j.precisioneng.2018.06.004_bib3) 2014; 63 10.1016/j.precisioneng.2018.06.004_bib12 10.1016/j.precisioneng.2018.06.004_bib13 10.1016/j.precisioneng.2018.06.004_bib10 Izumi (10.1016/j.precisioneng.2018.06.004_bib11) 1993; 40–2 Abe (10.1016/j.precisioneng.2018.06.004_bib14) 2015 Ambrose (10.1016/j.precisioneng.2018.06.004_bib4) 1973; 46 10.1016/j.precisioneng.2018.06.004_bib18 Yamada (10.1016/j.precisioneng.2018.06.004_bib16) 2014; 8 10.1016/j.precisioneng.2018.06.004_bib17 |
References_xml | – volume: 60 start-page: 821 year: 2011 ident: bib2 article-title: Computed tomography for dimensional metrology publication-title: CIRP Annals contributor: fullname: Kruth – volume: 40–2 start-page: 158 year: 1993 ident: bib11 article-title: High energy X-ray computed tomography for industrial applications publication-title: IEEE Trans Nucl Sci contributor: fullname: Izumi – volume: 56–2 start-page: 581 year: 2007 ident: bib1 article-title: Metrology of freeform shaped parts publication-title: CIRP Annals contributor: fullname: Savio – volume: 63 start-page: 655 year: 2014 ident: bib3 article-title: Industrial applications of computed tomography publication-title: CIRP Annals contributor: fullname: De Chiffre – ident: bib9 – volume: 46 start-page: 1023 year: 1973 ident: bib4 article-title: Computerized transverse axial tomography publication-title: Br J Radiol contributor: fullname: Hounsfield – year: 2015 ident: bib14 article-title: Evaluation of resolution performance of high energy X-ray CT. Proc. icOPEN2015 contributor: fullname: Takatsuji – volume: 8 year: 2014 ident: bib16 article-title: Tabletop synchrotron light source publication-title: Comprehensive Biomed Phys contributor: fullname: Yamada – volume: 41 start-page: 732 year: 1983 ident: bib5 article-title: New possibilities of non-destructive evaluation by X-ray computed tomography publication-title: Mater Eval contributor: fullname: Gobbels – year: 2015 ident: 10.1016/j.precisioneng.2018.06.004_bib14 contributor: fullname: Abe – volume: 8 issue: 43 year: 2014 ident: 10.1016/j.precisioneng.2018.06.004_bib16 article-title: Tabletop synchrotron light source publication-title: Comprehensive Biomed Phys doi: 10.1016/B978-0-444-53632-7.00604-3 contributor: fullname: Yamada – volume: 46 start-page: 1023 year: 1973 ident: 10.1016/j.precisioneng.2018.06.004_bib4 article-title: Computerized transverse axial tomography publication-title: Br J Radiol doi: 10.1259/0007-1285-46-552-1023 contributor: fullname: Ambrose – ident: 10.1016/j.precisioneng.2018.06.004_bib6 – ident: 10.1016/j.precisioneng.2018.06.004_bib7 – ident: 10.1016/j.precisioneng.2018.06.004_bib8 – ident: 10.1016/j.precisioneng.2018.06.004_bib10 – ident: 10.1016/j.precisioneng.2018.06.004_bib12 – ident: 10.1016/j.precisioneng.2018.06.004_bib13 – volume: 60 start-page: 821 issue: 2 year: 2011 ident: 10.1016/j.precisioneng.2018.06.004_bib2 article-title: Computed tomography for dimensional metrology publication-title: CIRP Annals doi: 10.1016/j.cirp.2011.05.006 contributor: fullname: Kruth – volume: 40–2 start-page: 158 year: 1993 ident: 10.1016/j.precisioneng.2018.06.004_bib11 article-title: High energy X-ray computed tomography for industrial applications publication-title: IEEE Trans Nucl Sci doi: 10.1109/23.212333 contributor: fullname: Izumi – volume: 63 start-page: 655 issue: 2 year: 2014 ident: 10.1016/j.precisioneng.2018.06.004_bib3 article-title: Industrial applications of computed tomography publication-title: CIRP Annals doi: 10.1016/j.cirp.2014.05.011 contributor: fullname: De Chiffre – ident: 10.1016/j.precisioneng.2018.06.004_bib17 – ident: 10.1016/j.precisioneng.2018.06.004_bib15 – volume: 41 start-page: 732 year: 1983 ident: 10.1016/j.precisioneng.2018.06.004_bib5 article-title: New possibilities of non-destructive evaluation by X-ray computed tomography publication-title: Mater Eval contributor: fullname: Reimers – volume: 56–2 start-page: 581 year: 2007 ident: 10.1016/j.precisioneng.2018.06.004_bib1 article-title: Metrology of freeform shaped parts publication-title: CIRP Annals contributor: fullname: Savio – ident: 10.1016/j.precisioneng.2018.06.004_bib18 |
SSID | ssj0007804 |
Score | 2.2695134 |
Snippet | This paper introduces a novel high-energy and high-resolution X-ray computed tomography system called eXTRACT. Preliminary experimental testing was performed... |
SourceID | crossref elsevier |
SourceType | Aggregation Database Publisher |
StartPage | 276 |
SubjectTerms | Computed tomography High-energy High-resolution X-ray |
Title | Development of high-energy and high-resolution X-ray CT |
URI | https://dx.doi.org/10.1016/j.precisioneng.2018.06.004 |
Volume | 54 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV07T8MwED71scCAeIryqDywmia1jZuBAVVUBUSnVupmOXaMyhCqqgws_HbOsYOCWJAYHemk5Hy5-z7puzuAK5kIl3ItaaqNoVwjQcmMtdQhF7FIoPWo6q94nt1MF_xxKZYtGNe9MF5WGXN_yOlVto5PBtGbg_VqNfCyJAQTIsOg9GmYtaGL5Wg46kD37uFpOvtOyH7GTlAyptQb1LNHK5nXelPvsilfvNIrjPOMe9t-1alG7Znsw14EjeQuvNcBtIryEHYbowSPQDbUP-TNET-GmBZVYx_RpQ1npNYx0siSbvQHGc-PYTG5n4-nNC5FoAaxz5ZmFgkVFhSbMGYs_j66MKlNhXSJc06OMl4wrEt4MVzIHMEfIhDEPCx1iTAYNuwEOiV-7SkQLNYulybRdphwzaQWvpW6qFijNnnWA1a7QK3D7AtVi8JeVdNxyjtOVQo53oPb2lvqx00qTNJ_sD_7p_057PhTUFZfQGe7eS8uEThs8z60rz_TfgyPLz5Hwuc |
link.rule.ids | 315,783,787,4509,24128,27936,27937,45597,45691 |
linkProvider | Elsevier |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV07T8MwED6VdgAGxFOUZwZWqwm2cTMwoIoqpY-plbpZjh2jMoSqKgP_nnPsoCAWJMYkOsk5n---T_ruDHAnYm4TpgRJlNaEKSQoqTaGWOQiBgm06lf9FdPZQ7ZgL0u-bMGg7oVxssqQ-31Or7J1eNML3uytV6uekyUhmOApBqVLw3QHOogGUjydnafROJt9J2Q3Y8crGRPiDOrZo5XMa72p77IpX53Sy4_zDPe2_apTjdozPISDABqjJ7-uI2gV5THsN0YJnoBoqH-idxu5McSkqBr7IlUa_4zUOkRatCQb9RkN5qewGD7PBxkJlyIQjdhnS1KDhAoLiokp1QaPjyp0YhIubGytFf2UFRTrEm4M4yJH8IcIBDEPTWzMNYYNPYN2iX97DhEWa5sLHStzHzNFheKulbqoWKPSedoFWrtArv3sC1mLwt5k03HSOU5WCjnWhcfaW_LHTkpM0n-wv_in_S3sZvPpRE5Gs_El7LkvXnx3Be3t5qO4RhCxzW9CkHwB-kzE2g |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Development+of+high-energy+and+high-resolution+X-ray+CT&rft.jtitle=Precision+engineering&rft.au=Sato%2C+Katsutoshi&rft.au=Abe%2C+Makoto&rft.au=Takatsuji%2C+Toshiyuki&rft.date=2018-10-01&rft.pub=Elsevier+Inc&rft.issn=0141-6359&rft.eissn=1873-2372&rft.volume=54&rft.spage=276&rft.epage=283&rft_id=info:doi/10.1016%2Fj.precisioneng.2018.06.004&rft.externalDocID=S0141635918303623 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0141-6359&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0141-6359&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0141-6359&client=summon |