Uncertainty Quantification in Flow Cytometry Using a Cell Sorter
ABSTRACT In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise toward total measured variation. Fundamentally, this is due to the fact that one cannot measure the same particle multiple times. We propose a simple experiment that uses a cell sorter...
Saved in:
Published in | Cytometry. Part A Vol. 107; no. 4; pp. 248 - 262 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
Hoboken, USA
John Wiley & Sons, Inc
01.04.2025
Wiley Subscription Services, Inc |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | ABSTRACT
In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise toward total measured variation. Fundamentally, this is due to the fact that one cannot measure the same particle multiple times. We propose a simple experiment that uses a cell sorter to distinguish instrument‐specific variation. For a population of beads whose intensities are distributed around a single peak, the sorter is used to collect beads whose measured intensities lie below some threshold. This subset of particles is then remeasured. If the variation in the measured values is only due to the sample, the second set of measurements should also lie entirely below our threshold. Any “spillover” is therefore due to instrument‐specific effects—we demonstrate how the distribution of the post‐sort measurements is sufficient to extract an estimate of the cumulative variability induced by the instrument. A distinguishing feature of our work is that we do not make any assumptions about the sources of said noise. We then show how “local affine transformations” let us transfer these estimates to cytometers not equipped with a sorter. We use our analysis to estimate noise for a set of three instruments and two bead types, across a range of sample flow rates. Lastly, we discuss the implications of instrument noise on optimal classification, as well as other applications. |
---|---|
AbstractList | In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise toward total measured variation. Fundamentally, this is due to the fact that one cannot measure the same particle multiple times. We propose a simple experiment that uses a cell sorter to distinguish instrument‐specific variation. For a population of beads whose intensities are distributed around a single peak, the sorter is used to collect beads whose measured intensities lie below some threshold. This subset of particles is then remeasured. If the variation in the measured values is only due to the sample, the second set of measurements should also lie entirely below our threshold. Any “spillover” is therefore due to instrument‐specific effects—we demonstrate how the distribution of the post‐sort measurements is sufficient to extract an estimate of the cumulative variability induced by the instrument. A distinguishing feature of our work is that we do not make any assumptions about the sources of said noise. We then show how “local affine transformations” let us transfer these estimates to cytometers not equipped with a sorter. We use our analysis to estimate noise for a set of three instruments and two bead types, across a range of sample flow rates. Lastly, we discuss the implications of instrument noise on optimal classification, as well as other applications. ABSTRACT In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise toward total measured variation. Fundamentally, this is due to the fact that one cannot measure the same particle multiple times. We propose a simple experiment that uses a cell sorter to distinguish instrument‐specific variation. For a population of beads whose intensities are distributed around a single peak, the sorter is used to collect beads whose measured intensities lie below some threshold. This subset of particles is then remeasured. If the variation in the measured values is only due to the sample, the second set of measurements should also lie entirely below our threshold. Any “spillover” is therefore due to instrument‐specific effects—we demonstrate how the distribution of the post‐sort measurements is sufficient to extract an estimate of the cumulative variability induced by the instrument. A distinguishing feature of our work is that we do not make any assumptions about the sources of said noise. We then show how “local affine transformations” let us transfer these estimates to cytometers not equipped with a sorter. We use our analysis to estimate noise for a set of three instruments and two bead types, across a range of sample flow rates. Lastly, we discuss the implications of instrument noise on optimal classification, as well as other applications. In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise toward total measured variation. Fundamentally, this is due to the fact that one cannot measure the same particle multiple times. We propose a simple experiment that uses a cell sorter to distinguish instrument-specific variation. For a population of beads whose intensities are distributed around a single peak, the sorter is used to collect beads whose measured intensities lie below some threshold. This subset of particles is then remeasured. If the variation in the measured values is only due to the sample, the second set of measurements should also lie entirely below our threshold. Any "spillover" is therefore due to instrument-specific effects-we demonstrate how the distribution of the post-sort measurements is sufficient to extract an estimate of the cumulative variability induced by the instrument. A distinguishing feature of our work is that we do not make any assumptions about the sources of said noise. We then show how "local affine transformations" let us transfer these estimates to cytometers not equipped with a sorter. We use our analysis to estimate noise for a set of three instruments and two bead types, across a range of sample flow rates. Lastly, we discuss the implications of instrument noise on optimal classification, as well as other applications.In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise toward total measured variation. Fundamentally, this is due to the fact that one cannot measure the same particle multiple times. We propose a simple experiment that uses a cell sorter to distinguish instrument-specific variation. For a population of beads whose intensities are distributed around a single peak, the sorter is used to collect beads whose measured intensities lie below some threshold. This subset of particles is then remeasured. If the variation in the measured values is only due to the sample, the second set of measurements should also lie entirely below our threshold. Any "spillover" is therefore due to instrument-specific effects-we demonstrate how the distribution of the post-sort measurements is sufficient to extract an estimate of the cumulative variability induced by the instrument. A distinguishing feature of our work is that we do not make any assumptions about the sources of said noise. We then show how "local affine transformations" let us transfer these estimates to cytometers not equipped with a sorter. We use our analysis to estimate noise for a set of three instruments and two bead types, across a range of sample flow rates. Lastly, we discuss the implications of instrument noise on optimal classification, as well as other applications. |
Author | Patrone, Paul N. Cooksey, Gregory A. Krishnaswamy‐Usha, Amudhan |
Author_xml | – sequence: 1 givenname: Amudhan orcidid: 0000-0002-8361-1426 surname: Krishnaswamy‐Usha fullname: Krishnaswamy‐Usha, Amudhan organization: Chakra Consulting Inc – sequence: 2 givenname: Gregory A. surname: Cooksey fullname: Cooksey, Gregory A. organization: National Institute of Standards and Technology – sequence: 3 givenname: Paul N. surname: Patrone fullname: Patrone, Paul N. email: paul.patrone@nist.gov organization: National Institute of Standards and Technology |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/40135908$$D View this record in MEDLINE/PubMed |
BookMark | eNp90D1LAzEYB_AgFfuim7McuDjYmtfeZbMcVoVCEdvBKaS5nKRck5rcUe7bm9rawcHpeYbf88K_DzrWWQ3ANYIjBCF-UG3tRnKEKcfsDPQQY3hIOYGdU49xF_RDWENIGCT4AnQpRIRxmPXA49Iq7WtpbN0mb420tSmNkrVxNjE2mVZul-TxwkbXvk2WwdjPRCa5rqrk3fla-0twXsoq6KtjHYDl9GmRvwxn8-fXfDIbKoIJG5aaKpRRCQuWokyNOVeKKLnCsiCqoJjAlJdyrDKuOZV8DMcEUV0UZVoWacokGYC7w96td1-NDrXYmKDiH9Jq1wRBUIZICiGjkd7-oWvXeBu_iyquxpAQFtXNUTWrjS7E1puN9K34zSaC-wNQ3oXgdXkiCIp99GIfvZDiJ_rI6YHvTKXbf63IPxbzyWHsG0S-hfk |
Cites_doi | 10.1111/j.1751-5823.2001.tb00465.x 10.1002/cyto.a.24281 10.1109/TIM.2013.2248293 10.1002/(SICI)1097-0320(19981001)33:2<267::AID-CYTO24>3.0.CO;2-R 10.1002/cyto.a.23972 10.1371/journal.pone.0248118 10.1039/D1LC01169C 10.1007/s00216-020-02930-z 10.6028/jres.121.012 10.1186/1475-2859-5-12 10.1002/(SICI)1097-0320(19981001)33:2<256::AID-CYTO22>3.0.CO;2-S 10.1002/cpcy.14 10.1007/10_2007_073 10.2307/3315571 10.3109/07388551.2015.1128876 10.6028/jres.107.027 10.1002/(SICI)1097-0320(19981001)33:2<260::AID-CYTO23>3.0.CO;2-R 10.1214/aos/1176348248 10.1002/cyto.990130804 10.1002/cyto.990130702 10.1051/ps:2002015 |
ContentType | Journal Article |
Copyright | Published 2025. This article is a U.S. Government work and is in the public domain in the USA. 2025 International Society for Advancement of Cytometry |
Copyright_xml | – notice: Published 2025. This article is a U.S. Government work and is in the public domain in the USA. – notice: 2025 International Society for Advancement of Cytometry |
DBID | AAYXX CITATION CGR CUY CVF ECM EIF NPM 7QO 7TK 8FD FR3 P64 7X8 |
DOI | 10.1002/cyto.a.24925 |
DatabaseName | CrossRef Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed Biotechnology Research Abstracts Neurosciences Abstracts Technology Research Database Engineering Research Database Biotechnology and BioEngineering Abstracts MEDLINE - Academic |
DatabaseTitle | CrossRef MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) Engineering Research Database Biotechnology Research Abstracts Technology Research Database Neurosciences Abstracts Biotechnology and BioEngineering Abstracts MEDLINE - Academic |
DatabaseTitleList | Engineering Research Database MEDLINE MEDLINE - Academic CrossRef |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Biology |
EISSN | 1552-4930 |
EndPage | 262 |
ExternalDocumentID | 40135908 10_1002_cyto_a_24925 CYTOA24925 |
Genre | researchArticle Journal Article |
GrantInformation_xml | – fundername: National Institute of Standards and Technology funderid: 1333ND23FNB770067 – fundername: NIST DOC grantid: 1333ND23FNB770067 |
GroupedDBID | --- -~X .3N .GA .Y3 05W 0R~ 10A 1L6 1OC 2WC 31~ 33P 3SF 4.4 4ZD 50Z 51W 51X 52M 52N 52O 52P 52S 52T 52U 52W 52X 53G 5GY 5VS 66C 7PT 8-0 8-1 8-3 8-4 8-5 8UM 930 A03 AAESR AAEVG AAHHS AAHQN AAMNL AANLZ AAONW AASGY AAXRX AAYCA AAZKR ABCQN ABCUV ABEML ABIJN ABLJU ABPVW ACAHQ ACCFJ ACCZN ACFBH ACGFS ACIWK ACPOU ACPRK ACSCC ACXBN ACXQS ADBBV ADEOM ADIZJ ADKYN ADMGS ADOZA ADXAS ADZMN ADZOD AEEZP AEGXH AEIGN AEIMD AENEX AEQDE AEUYR AFBPY AFFPM AFGKR AFRAH AFWVQ AFZJQ AGHNM AGYGG AHBTC AITYG AIURR AIWBW AJBDE AJXKR ALAGY ALMA_UNASSIGNED_HOLDINGS ALUQN ALVPJ AMBMR AMYDB ATUGU AUFTA AZBYB AZVAB BAFTC BAWUL BFHJK BHBCM BMNLL BMXJE BNHUX BROTX BRXPI BY8 CO8 CS3 D-E D-F DCZOG DIK DPXWK DR2 DRFUL DRSTM DU5 E3Z EBD EBS EJD EMOBN F00 F01 F04 F5P G-S G.N GNP GODZA H.T H.X HBH HF~ HGLYW HHY HHZ HZ~ IX1 J0M JPC KQQ LATKE LAW LC2 LC3 LEEKS LH4 LITHE LOXES LP6 LP7 LUTES LW6 LYRES MEWTI MRFUL MRSTM MSFUL MSSTM MXFUL MXSTM N04 N05 N9A NF~ O66 O9- OIG OK1 P2P P2W P2X P4D Q.N QB0 QRW R.K RNS ROL SUPJJ SV3 UB1 V2E W8V W99 WBKPD WIH WIK WIN WJL WNSPC WOHZO WQJ WXSBR WYISQ XG1 XV2 ZZTAW ~IA ~KM ~WT AAMMB AAYXX AEFGJ AEYWJ AGXDD AIDQK AIDYY CITATION CGR CUY CVF ECM EIF NPM 7QO 7TK 8FD FR3 P64 7X8 |
ID | FETCH-LOGICAL-c3235-fe4c184a0d5718c699cc3cab2ad3cd423079fa6c89e94a9606314eddf7fd775a3 |
IEDL.DBID | DR2 |
ISSN | 1552-4922 1552-4930 |
IngestDate | Fri Jul 11 18:57:38 EDT 2025 Fri Jul 25 20:11:55 EDT 2025 Mon Jul 21 05:47:46 EDT 2025 Tue Jul 29 01:59:39 EDT 2025 Tue Apr 29 10:30:33 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 4 |
Keywords | gating beads uncertainty quantification FACS sorting |
Language | English |
License | Published 2025. This article is a U.S. Government work and is in the public domain in the USA. |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c3235-fe4c184a0d5718c699cc3cab2ad3cd423079fa6c89e94a9606314eddf7fd775a3 |
Notes | This work was supported by National Institute of Standards and Technology, 1333ND23FNB770067. Funding ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
ORCID | 0000-0002-8361-1426 |
PMID | 40135908 |
PQID | 3196020335 |
PQPubID | 2045167 |
PageCount | 15 |
ParticipantIDs | proquest_miscellaneous_3181370054 proquest_journals_3196020335 pubmed_primary_40135908 crossref_primary_10_1002_cyto_a_24925 wiley_primary_10_1002_cyto_a_24925_CYTOA24925 |
PublicationCentury | 2000 |
PublicationDate | April 2025 |
PublicationDateYYYYMMDD | 2025-04-01 |
PublicationDate_xml | – month: 04 year: 2025 text: April 2025 |
PublicationDecade | 2020 |
PublicationPlace | Hoboken, USA |
PublicationPlace_xml | – name: Hoboken, USA – name: United States – name: Hoboken |
PublicationTitle | Cytometry. Part A |
PublicationTitleAlternate | Cytometry A |
PublicationYear | 2025 |
Publisher | John Wiley & Sons, Inc Wiley Subscription Services, Inc |
Publisher_xml | – name: John Wiley & Sons, Inc – name: Wiley Subscription Services, Inc |
References | 2021; 16 1991; 19 2021; 99 2017; 37 2020; 97 2013; 62 2002; 6 2017; 79 2002; 107 2000; 62 2020; 412 2007 2006; 5 2016; 121 1999; 43 1992; 13 2022; 22 1992; 20 2001; 69 1998; 33 e_1_2_10_12_1 Cramér H. (e_1_2_10_15_1) 1999 e_1_2_10_23_1 e_1_2_10_9_1 e_1_2_10_13_1 e_1_2_10_24_1 e_1_2_10_10_1 e_1_2_10_21_1 e_1_2_10_11_1 e_1_2_10_22_1 e_1_2_10_20_1 e_1_2_10_2_1 e_1_2_10_4_1 e_1_2_10_3_1 e_1_2_10_6_1 e_1_2_10_16_1 e_1_2_10_5_1 e_1_2_10_17_1 e_1_2_10_8_1 e_1_2_10_14_1 Arnold B. C. (e_1_2_10_18_1) 2000; 62 Engh G. (e_1_2_10_19_1) 1992; 13 e_1_2_10_25_1 e_1_2_10_7_1 |
References_xml | – volume: 37 start-page: 163 issue: 2 year: 2017 end-page: 176 article-title: Flow Cytometry: Basic Principles and Applications publication-title: Critical Reviews in Biotechnology – volume: 79 start-page: 1 issue: 1 year: 2017 end-page: 3 article-title: Standardization, Calibration, and Control in Flow Cytometry publication-title: Current Protocols in Cytometry – volume: 43 year: 1999 – volume: 13 start-page: 669 issue: 7 year: 1992 end-page: 677 article-title: Photo‐Bleaching and Photon Saturation in Flow Cytometry publication-title: Cytometry: The Journal of the International Society for Analytical Cytology – volume: 107 start-page: 339 issue: 4 year: 2002 article-title: Quantitating Fluorescence Intensity From Fluorophores: Practical Use of Mesf Values publication-title: Journal of Research of the National Institute of Standards and Technology – volume: 13 start-page: 822 issue: 8 year: 1992 end-page: 830 article-title: Noise, Sensitivity, and Resolution of Flow Cytometers publication-title: Cytometry – volume: 16 issue: 3 year: 2021 article-title: Establishing cd19 b‐Cell Reference Control Materials for Comparable and Quantitative Cytometric Expression Analysis publication-title: PLoS One – volume: 6 start-page: 271 year: 2002 end-page: 292 article-title: Semiparametric Deconvolution With Unknown Noise Variance publication-title: ESAIM Probability and Statistics – volume: 5 start-page: 1 issue: 1 year: 2006 end-page: 11 article-title: Applications of Cell Sorting in Biotechnology publication-title: Microbial Cell Factories – volume: 62 start-page: 23 issue: 1 year: 2000 end-page: 35 article-title: Hidden Truncation Models publication-title: Sankhyā: The Indian Journal of Statistics, Series A – volume: 22 start-page: 3217 issue: 17 year: 2022 end-page: 3228 article-title: Serial Flow Cytometry in an Inertial Focusing Optofluidic Microchip for Direct Assessment of Measurement Variations publication-title: Lab on a Chip – volume: 33 start-page: 256 issue: 2 year: 1998 end-page: 259 article-title: Evaluating Fluorescence Sensitivity on Flow Cytometers: An Overview publication-title: Cytometry – volume: 62 start-page: 1960 issue: 7 year: 2013 end-page: 1971 article-title: Statistics of Particle Detection From Single‐Channel Fluorescence Signals for Flow Cytometric Applications publication-title: IEEE Transactions on Instrumentation and Measurement – volume: 20 start-page: 9 issue: 1 year: 1992 end-page: 21 article-title: Gaussian Deconvolution via Differentiation publication-title: Canadian Journal of Statistics – volume: 19 start-page: 1257 year: 1991 end-page: 1272 article-title: On the Optimal Rates of Convergence for Nonparametric Deconvolution Problems publication-title: Annals of Statistics – start-page: 19 year: 2007 end-page: 39 – volume: 99 start-page: 664 issue: 7 year: 2021 end-page: 667 article-title: How Well Can Your Flow Cytometer Detect Photons? publication-title: Cytometry, Part A – volume: 33 start-page: 267 issue: 2 year: 1998 end-page: 279 article-title: Resolution of Dimly Fluorescent Particles: A Practical Measure of Fluorescence Sensitivity publication-title: Cytometry – volume: 97 start-page: 105 issue: 2 year: 2020 end-page: 106 article-title: Special Issue on Enhancement of Reproducibility and Rigor publication-title: Cytometry, Part A – volume: 121 start-page: 264 year: 2016 article-title: Assignment of the Number of Equivalent Reference Fluorophores to Dyed Microspheres publication-title: Journal of Research of the National Institute of Standards and Technology – volume: 69 start-page: 385 issue: 3 year: 2001 end-page: 398 article-title: Idiot's Bayes—Not So Stupid After all? publication-title: International Statistical Review – volume: 33 start-page: 260 issue: 2 year: 1998 end-page: 266 article-title: Fundamental Flow Cytometer Properties Governing Sensitivity and Resolution publication-title: Cytometry – volume: 412 start-page: 7977 year: 2020 end-page: 7988 article-title: Affine Analysis for Quantitative Pcr Measurements publication-title: Analytical and Bioanalytical Chemistry – ident: e_1_2_10_21_1 doi: 10.1111/j.1751-5823.2001.tb00465.x – ident: e_1_2_10_12_1 doi: 10.1002/cyto.a.24281 – ident: e_1_2_10_10_1 doi: 10.1109/TIM.2013.2248293 – ident: e_1_2_10_11_1 doi: 10.1002/(SICI)1097-0320(19981001)33:2<267::AID-CYTO24>3.0.CO;2-R – ident: e_1_2_10_16_1 doi: 10.1002/cyto.a.23972 – ident: e_1_2_10_22_1 doi: 10.1371/journal.pone.0248118 – ident: e_1_2_10_9_1 doi: 10.1039/D1LC01169C – volume: 62 start-page: 23 issue: 1 year: 2000 ident: e_1_2_10_18_1 article-title: Hidden Truncation Models publication-title: Sankhyā: The Indian Journal of Statistics, Series A – ident: e_1_2_10_20_1 doi: 10.1007/s00216-020-02930-z – ident: e_1_2_10_14_1 doi: 10.6028/jres.121.012 – ident: e_1_2_10_4_1 doi: 10.1186/1475-2859-5-12 – ident: e_1_2_10_6_1 doi: 10.1002/(SICI)1097-0320(19981001)33:2<256::AID-CYTO22>3.0.CO;2-S – ident: e_1_2_10_7_1 doi: 10.1002/cpcy.14 – ident: e_1_2_10_3_1 doi: 10.1007/10_2007_073 – volume-title: Mathematical Methods of Statistics year: 1999 ident: e_1_2_10_15_1 – ident: e_1_2_10_25_1 doi: 10.2307/3315571 – ident: e_1_2_10_2_1 doi: 10.3109/07388551.2015.1128876 – ident: e_1_2_10_17_1 – ident: e_1_2_10_13_1 doi: 10.6028/jres.107.027 – ident: e_1_2_10_5_1 doi: 10.1002/(SICI)1097-0320(19981001)33:2<260::AID-CYTO23>3.0.CO;2-R – ident: e_1_2_10_23_1 doi: 10.1214/aos/1176348248 – ident: e_1_2_10_8_1 doi: 10.1002/cyto.990130804 – volume: 13 start-page: 669 issue: 7 year: 1992 ident: e_1_2_10_19_1 article-title: Photo‐Bleaching and Photon Saturation in Flow Cytometry publication-title: Cytometry: The Journal of the International Society for Analytical Cytology doi: 10.1002/cyto.990130702 – ident: e_1_2_10_24_1 doi: 10.1051/ps:2002015 |
SSID | ssj0035032 |
Score | 2.4202075 |
Snippet | ABSTRACT
In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise toward total measured variation.... In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise toward total measured variation. Fundamentally, this... |
SourceID | proquest pubmed crossref wiley |
SourceType | Aggregation Database Index Database Publisher |
StartPage | 248 |
SubjectTerms | Affine transformations beads Cell Separation - instrumentation Cell Separation - methods FACS Flow cytometry Flow Cytometry - instrumentation Flow Cytometry - methods Flow rates gating Humans sorting Uncertainty uncertainty quantification Variation |
Title | Uncertainty Quantification in Flow Cytometry Using a Cell Sorter |
URI | https://onlinelibrary.wiley.com/doi/abs/10.1002%2Fcyto.a.24925 https://www.ncbi.nlm.nih.gov/pubmed/40135908 https://www.proquest.com/docview/3196020335 https://www.proquest.com/docview/3181370054 |
Volume | 107 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1dS8MwFA0yEHzx-2M6JYI-dluTtF3eHMUxBBV1g_kU0iQFcXaydcj89eam3XQKgr4VkrRpbm5ykpyci9BZM7ApqSEeSSx8YyrVXoto3-OU-yriJNEG7jtf34TdPrsaBINyww3uwhT6EIsNN_AMN16Dg8tk0vgUDVWzfFSXdVC8gzvmQNcCTHS_UI-iQdPFJwORMc_mIiXv3RZvfC28PCP9gJnLqNVNO50NJOYVLtgmz_VpntTV-zctx___0SZaLxEpbhddaAutmGwbrRYxKmc76KJvu4WjDeQzfDeVBbnI2RM_ZbgzHL3h2L7yxeTjGXYMBCxxbIZD_ABE3vEu6ncue3HXK8MueIoSGnipYcqu-2RTB3biUiHnSlElEyI1VZoBc5ynMlQtbjiTsAKiPjNap1GqoyiQdA9VslFmDhAOE99XkvIErqFIxlsy1YxJoywMjJq-rqLzedOL10JdQxQ6ykRAawgpXGtUUW1uF1H62ETA4AHnqNQmny6SrXfAkYfMzGgKeVo-jQCXVtF-Yc_Fh2BlCRHfq8hzVvm1BiJ-7N223ePhH_MfoTUCQYMd3aeGKvl4ao4tksmTE9dfPwDDEu6a |
linkProvider | Wiley-Blackwell |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1Bb9MwFH4anRBcYGNs6xjMSHBM29hOUt82dasKtEWDVhonz7EdCa1Lp5Jq6n49fk5a1k1CQtwi2U4cPz_72f78fQAfWpFLySwNaOrCN64zE7SpCQPBRKgTQVNj8b7zYBj3xvzzRXRR6ZziXZiSH2K14Yae4cdrdHDckG7-YQ3Vi2LaUA2kvIuewCaKeiN5_um3FX8Ui1peoQxpxgKXjVbId1e-eb_0-pz0KNBcj1v9xNN9CZfLKpd4k6vGvEgb-u4Bm-N__NMWvKiCUnJS9qJt2LD5K3haylQuduB47HqGRw4UC3I-VyW-yJuU_MxJdzK9JR33ymtbzBbEgxCIIh07mZDviOWdvYZx92zU6QWV8kKgGWVRkFmu3dJPtUzk5i4dC6E10yqlyjBtOILHRaZi3RZWcIWLIBZya0yWZCZJIsV2oZZPc7sPJE7DUCsmUryJorhoq8xwrqx2kWDSCk0dPi7bXt6UBBuypFKmEltDKulbow6HS8PIys1-SRw_8CiVueT3q2TnIHjqoXI7nWOedsgSDE3rsFcadPUhXFyi6HsdAm-Wv9ZAdn6Mvp74x4N_zH8Ez3qjQV_2Pw2_vIHnFDWEPfrnEGrFbG7fusCmSN_5zvsbrm7ytg |
linkToPdf | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1bT9swFD7ioiFegG1sdFzmSfCYkthOUr-BChW3sXGpBE-WYzsSoqSopELdr8fHSbvBJCR4i2Q7cXx87M_25-8AbIaxS8ktDWjm4BvXuQla1ESBYCLSqaCZsXjf-edpctDlR1fxVb3hhndhKn2IyYYbeoYfr9HB702-_Vc0VI_KflM1UfEunoZZnoQCQzfsnU_ko1gc-gBlqDIWuGy0Jr678tv_ln4-Jf2HM5_DVj_vdBZBjmtc0U1um8Mya-o_L8Qc3_9LS7BQQ1KyW_WhjzBli0_woQpSOfoMO13XLzxvoByRs6Gq2EXeoOSmIJ1e_5G03SvvbDkYEU9BIIq0ba9HLpDJO1iGbmf_sn0Q1HEXAs0oi4Pccu0Wfio0sZu5dCKE1kyrjCrDtOFIHRe5SnRLWMEVLoFYxK0xeZqbNI0V-wIzRb-wK0CSLIq0YiLDeyiKi5bKDefKaocD0zAyDdgaN728r-Q1ZCWkTCW2hlTSt0YD1sZ2kbWTPUgcPfAglbnkH5Nk5x545qEK2x9inlbEUgSmDfha2XPyIVxaYsj3BgTeKq_WQLavL3_t-sdvb8z_HeZ-73XkyeHp8SrMUwwg7Kk_azBTDoZ23aGaMtvwXfcJ5ofxZQ |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Uncertainty+Quantification+in+Flow+Cytometry+Using+a+Cell+Sorter&rft.jtitle=Cytometry.+Part+A&rft.au=Krishnaswamy%E2%80%90Usha%2C+Amudhan&rft.au=Cooksey%2C+Gregory+A.&rft.au=Patrone%2C+Paul+N.&rft.date=2025-04-01&rft.pub=John+Wiley+%26+Sons%2C+Inc&rft.issn=1552-4922&rft.eissn=1552-4930&rft.volume=107&rft.issue=4&rft.spage=248&rft.epage=262&rft_id=info:doi/10.1002%2Fcyto.a.24925&rft.externalDBID=10.1002%252Fcyto.a.24925&rft.externalDocID=CYTOA24925 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1552-4922&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1552-4922&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1552-4922&client=summon |