Uncertainty Quantification in Flow Cytometry Using a Cell Sorter

ABSTRACT In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise toward total measured variation. Fundamentally, this is due to the fact that one cannot measure the same particle multiple times. We propose a simple experiment that uses a cell sorter...

Full description

Saved in:
Bibliographic Details
Published inCytometry. Part A Vol. 107; no. 4; pp. 248 - 262
Main Authors Krishnaswamy‐Usha, Amudhan, Cooksey, Gregory A., Patrone, Paul N.
Format Journal Article
LanguageEnglish
Published Hoboken, USA John Wiley & Sons, Inc 01.04.2025
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text

Cover

Loading…
Abstract ABSTRACT In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise toward total measured variation. Fundamentally, this is due to the fact that one cannot measure the same particle multiple times. We propose a simple experiment that uses a cell sorter to distinguish instrument‐specific variation. For a population of beads whose intensities are distributed around a single peak, the sorter is used to collect beads whose measured intensities lie below some threshold. This subset of particles is then remeasured. If the variation in the measured values is only due to the sample, the second set of measurements should also lie entirely below our threshold. Any “spillover” is therefore due to instrument‐specific effects—we demonstrate how the distribution of the post‐sort measurements is sufficient to extract an estimate of the cumulative variability induced by the instrument. A distinguishing feature of our work is that we do not make any assumptions about the sources of said noise. We then show how “local affine transformations” let us transfer these estimates to cytometers not equipped with a sorter. We use our analysis to estimate noise for a set of three instruments and two bead types, across a range of sample flow rates. Lastly, we discuss the implications of instrument noise on optimal classification, as well as other applications.
AbstractList In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise toward total measured variation. Fundamentally, this is due to the fact that one cannot measure the same particle multiple times. We propose a simple experiment that uses a cell sorter to distinguish instrument‐specific variation. For a population of beads whose intensities are distributed around a single peak, the sorter is used to collect beads whose measured intensities lie below some threshold. This subset of particles is then remeasured. If the variation in the measured values is only due to the sample, the second set of measurements should also lie entirely below our threshold. Any “spillover” is therefore due to instrument‐specific effects—we demonstrate how the distribution of the post‐sort measurements is sufficient to extract an estimate of the cumulative variability induced by the instrument. A distinguishing feature of our work is that we do not make any assumptions about the sources of said noise. We then show how “local affine transformations” let us transfer these estimates to cytometers not equipped with a sorter. We use our analysis to estimate noise for a set of three instruments and two bead types, across a range of sample flow rates. Lastly, we discuss the implications of instrument noise on optimal classification, as well as other applications.
ABSTRACT In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise toward total measured variation. Fundamentally, this is due to the fact that one cannot measure the same particle multiple times. We propose a simple experiment that uses a cell sorter to distinguish instrument‐specific variation. For a population of beads whose intensities are distributed around a single peak, the sorter is used to collect beads whose measured intensities lie below some threshold. This subset of particles is then remeasured. If the variation in the measured values is only due to the sample, the second set of measurements should also lie entirely below our threshold. Any “spillover” is therefore due to instrument‐specific effects—we demonstrate how the distribution of the post‐sort measurements is sufficient to extract an estimate of the cumulative variability induced by the instrument. A distinguishing feature of our work is that we do not make any assumptions about the sources of said noise. We then show how “local affine transformations” let us transfer these estimates to cytometers not equipped with a sorter. We use our analysis to estimate noise for a set of three instruments and two bead types, across a range of sample flow rates. Lastly, we discuss the implications of instrument noise on optimal classification, as well as other applications.
In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise toward total measured variation. Fundamentally, this is due to the fact that one cannot measure the same particle multiple times. We propose a simple experiment that uses a cell sorter to distinguish instrument-specific variation. For a population of beads whose intensities are distributed around a single peak, the sorter is used to collect beads whose measured intensities lie below some threshold. This subset of particles is then remeasured. If the variation in the measured values is only due to the sample, the second set of measurements should also lie entirely below our threshold. Any "spillover" is therefore due to instrument-specific effects-we demonstrate how the distribution of the post-sort measurements is sufficient to extract an estimate of the cumulative variability induced by the instrument. A distinguishing feature of our work is that we do not make any assumptions about the sources of said noise. We then show how "local affine transformations" let us transfer these estimates to cytometers not equipped with a sorter. We use our analysis to estimate noise for a set of three instruments and two bead types, across a range of sample flow rates. Lastly, we discuss the implications of instrument noise on optimal classification, as well as other applications.In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise toward total measured variation. Fundamentally, this is due to the fact that one cannot measure the same particle multiple times. We propose a simple experiment that uses a cell sorter to distinguish instrument-specific variation. For a population of beads whose intensities are distributed around a single peak, the sorter is used to collect beads whose measured intensities lie below some threshold. This subset of particles is then remeasured. If the variation in the measured values is only due to the sample, the second set of measurements should also lie entirely below our threshold. Any "spillover" is therefore due to instrument-specific effects-we demonstrate how the distribution of the post-sort measurements is sufficient to extract an estimate of the cumulative variability induced by the instrument. A distinguishing feature of our work is that we do not make any assumptions about the sources of said noise. We then show how "local affine transformations" let us transfer these estimates to cytometers not equipped with a sorter. We use our analysis to estimate noise for a set of three instruments and two bead types, across a range of sample flow rates. Lastly, we discuss the implications of instrument noise on optimal classification, as well as other applications.
Author Patrone, Paul N.
Cooksey, Gregory A.
Krishnaswamy‐Usha, Amudhan
Author_xml – sequence: 1
  givenname: Amudhan
  orcidid: 0000-0002-8361-1426
  surname: Krishnaswamy‐Usha
  fullname: Krishnaswamy‐Usha, Amudhan
  organization: Chakra Consulting Inc
– sequence: 2
  givenname: Gregory A.
  surname: Cooksey
  fullname: Cooksey, Gregory A.
  organization: National Institute of Standards and Technology
– sequence: 3
  givenname: Paul N.
  surname: Patrone
  fullname: Patrone, Paul N.
  email: paul.patrone@nist.gov
  organization: National Institute of Standards and Technology
BackLink https://www.ncbi.nlm.nih.gov/pubmed/40135908$$D View this record in MEDLINE/PubMed
BookMark eNp90D1LAzEYB_AgFfuim7McuDjYmtfeZbMcVoVCEdvBKaS5nKRck5rcUe7bm9rawcHpeYbf88K_DzrWWQ3ANYIjBCF-UG3tRnKEKcfsDPQQY3hIOYGdU49xF_RDWENIGCT4AnQpRIRxmPXA49Iq7WtpbN0mb420tSmNkrVxNjE2mVZul-TxwkbXvk2WwdjPRCa5rqrk3fla-0twXsoq6KtjHYDl9GmRvwxn8-fXfDIbKoIJG5aaKpRRCQuWokyNOVeKKLnCsiCqoJjAlJdyrDKuOZV8DMcEUV0UZVoWacokGYC7w96td1-NDrXYmKDiH9Jq1wRBUIZICiGjkd7-oWvXeBu_iyquxpAQFtXNUTWrjS7E1puN9K34zSaC-wNQ3oXgdXkiCIp99GIfvZDiJ_rI6YHvTKXbf63IPxbzyWHsG0S-hfk
Cites_doi 10.1111/j.1751-5823.2001.tb00465.x
10.1002/cyto.a.24281
10.1109/TIM.2013.2248293
10.1002/(SICI)1097-0320(19981001)33:2<267::AID-CYTO24>3.0.CO;2-R
10.1002/cyto.a.23972
10.1371/journal.pone.0248118
10.1039/D1LC01169C
10.1007/s00216-020-02930-z
10.6028/jres.121.012
10.1186/1475-2859-5-12
10.1002/(SICI)1097-0320(19981001)33:2<256::AID-CYTO22>3.0.CO;2-S
10.1002/cpcy.14
10.1007/10_2007_073
10.2307/3315571
10.3109/07388551.2015.1128876
10.6028/jres.107.027
10.1002/(SICI)1097-0320(19981001)33:2<260::AID-CYTO23>3.0.CO;2-R
10.1214/aos/1176348248
10.1002/cyto.990130804
10.1002/cyto.990130702
10.1051/ps:2002015
ContentType Journal Article
Copyright Published 2025. This article is a U.S. Government work and is in the public domain in the USA.
2025 International Society for Advancement of Cytometry
Copyright_xml – notice: Published 2025. This article is a U.S. Government work and is in the public domain in the USA.
– notice: 2025 International Society for Advancement of Cytometry
DBID AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
7QO
7TK
8FD
FR3
P64
7X8
DOI 10.1002/cyto.a.24925
DatabaseName CrossRef
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
Biotechnology Research Abstracts
Neurosciences Abstracts
Technology Research Database
Engineering Research Database
Biotechnology and BioEngineering Abstracts
MEDLINE - Academic
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
Engineering Research Database
Biotechnology Research Abstracts
Technology Research Database
Neurosciences Abstracts
Biotechnology and BioEngineering Abstracts
MEDLINE - Academic
DatabaseTitleList Engineering Research Database

MEDLINE
MEDLINE - Academic
CrossRef
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Biology
EISSN 1552-4930
EndPage 262
ExternalDocumentID 40135908
10_1002_cyto_a_24925
CYTOA24925
Genre researchArticle
Journal Article
GrantInformation_xml – fundername: National Institute of Standards and Technology
  funderid: 1333ND23FNB770067
– fundername: NIST DOC
  grantid: 1333ND23FNB770067
GroupedDBID ---
-~X
.3N
.GA
.Y3
05W
0R~
10A
1L6
1OC
2WC
31~
33P
3SF
4.4
4ZD
50Z
51W
51X
52M
52N
52O
52P
52S
52T
52U
52W
52X
53G
5GY
5VS
66C
7PT
8-0
8-1
8-3
8-4
8-5
8UM
930
A03
AAESR
AAEVG
AAHHS
AAHQN
AAMNL
AANLZ
AAONW
AASGY
AAXRX
AAYCA
AAZKR
ABCQN
ABCUV
ABEML
ABIJN
ABLJU
ABPVW
ACAHQ
ACCFJ
ACCZN
ACFBH
ACGFS
ACIWK
ACPOU
ACPRK
ACSCC
ACXBN
ACXQS
ADBBV
ADEOM
ADIZJ
ADKYN
ADMGS
ADOZA
ADXAS
ADZMN
ADZOD
AEEZP
AEGXH
AEIGN
AEIMD
AENEX
AEQDE
AEUYR
AFBPY
AFFPM
AFGKR
AFRAH
AFWVQ
AFZJQ
AGHNM
AGYGG
AHBTC
AITYG
AIURR
AIWBW
AJBDE
AJXKR
ALAGY
ALMA_UNASSIGNED_HOLDINGS
ALUQN
ALVPJ
AMBMR
AMYDB
ATUGU
AUFTA
AZBYB
AZVAB
BAFTC
BAWUL
BFHJK
BHBCM
BMNLL
BMXJE
BNHUX
BROTX
BRXPI
BY8
CO8
CS3
D-E
D-F
DCZOG
DIK
DPXWK
DR2
DRFUL
DRSTM
DU5
E3Z
EBD
EBS
EJD
EMOBN
F00
F01
F04
F5P
G-S
G.N
GNP
GODZA
H.T
H.X
HBH
HF~
HGLYW
HHY
HHZ
HZ~
IX1
J0M
JPC
KQQ
LATKE
LAW
LC2
LC3
LEEKS
LH4
LITHE
LOXES
LP6
LP7
LUTES
LW6
LYRES
MEWTI
MRFUL
MRSTM
MSFUL
MSSTM
MXFUL
MXSTM
N04
N05
N9A
NF~
O66
O9-
OIG
OK1
P2P
P2W
P2X
P4D
Q.N
QB0
QRW
R.K
RNS
ROL
SUPJJ
SV3
UB1
V2E
W8V
W99
WBKPD
WIH
WIK
WIN
WJL
WNSPC
WOHZO
WQJ
WXSBR
WYISQ
XG1
XV2
ZZTAW
~IA
~KM
~WT
AAMMB
AAYXX
AEFGJ
AEYWJ
AGXDD
AIDQK
AIDYY
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
7QO
7TK
8FD
FR3
P64
7X8
ID FETCH-LOGICAL-c3235-fe4c184a0d5718c699cc3cab2ad3cd423079fa6c89e94a9606314eddf7fd775a3
IEDL.DBID DR2
ISSN 1552-4922
1552-4930
IngestDate Fri Jul 11 18:57:38 EDT 2025
Fri Jul 25 20:11:55 EDT 2025
Mon Jul 21 05:47:46 EDT 2025
Tue Jul 29 01:59:39 EDT 2025
Tue Apr 29 10:30:33 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 4
Keywords gating
beads
uncertainty quantification
FACS
sorting
Language English
License Published 2025. This article is a U.S. Government work and is in the public domain in the USA.
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c3235-fe4c184a0d5718c699cc3cab2ad3cd423079fa6c89e94a9606314eddf7fd775a3
Notes This work was supported by National Institute of Standards and Technology, 1333ND23FNB770067.
Funding
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ORCID 0000-0002-8361-1426
PMID 40135908
PQID 3196020335
PQPubID 2045167
PageCount 15
ParticipantIDs proquest_miscellaneous_3181370054
proquest_journals_3196020335
pubmed_primary_40135908
crossref_primary_10_1002_cyto_a_24925
wiley_primary_10_1002_cyto_a_24925_CYTOA24925
PublicationCentury 2000
PublicationDate April 2025
PublicationDateYYYYMMDD 2025-04-01
PublicationDate_xml – month: 04
  year: 2025
  text: April 2025
PublicationDecade 2020
PublicationPlace Hoboken, USA
PublicationPlace_xml – name: Hoboken, USA
– name: United States
– name: Hoboken
PublicationTitle Cytometry. Part A
PublicationTitleAlternate Cytometry A
PublicationYear 2025
Publisher John Wiley & Sons, Inc
Wiley Subscription Services, Inc
Publisher_xml – name: John Wiley & Sons, Inc
– name: Wiley Subscription Services, Inc
References 2021; 16
1991; 19
2021; 99
2017; 37
2020; 97
2013; 62
2002; 6
2017; 79
2002; 107
2000; 62
2020; 412
2007
2006; 5
2016; 121
1999; 43
1992; 13
2022; 22
1992; 20
2001; 69
1998; 33
e_1_2_10_12_1
Cramér H. (e_1_2_10_15_1) 1999
e_1_2_10_23_1
e_1_2_10_9_1
e_1_2_10_13_1
e_1_2_10_24_1
e_1_2_10_10_1
e_1_2_10_21_1
e_1_2_10_11_1
e_1_2_10_22_1
e_1_2_10_20_1
e_1_2_10_2_1
e_1_2_10_4_1
e_1_2_10_3_1
e_1_2_10_6_1
e_1_2_10_16_1
e_1_2_10_5_1
e_1_2_10_17_1
e_1_2_10_8_1
e_1_2_10_14_1
Arnold B. C. (e_1_2_10_18_1) 2000; 62
Engh G. (e_1_2_10_19_1) 1992; 13
e_1_2_10_25_1
e_1_2_10_7_1
References_xml – volume: 37
  start-page: 163
  issue: 2
  year: 2017
  end-page: 176
  article-title: Flow Cytometry: Basic Principles and Applications
  publication-title: Critical Reviews in Biotechnology
– volume: 79
  start-page: 1
  issue: 1
  year: 2017
  end-page: 3
  article-title: Standardization, Calibration, and Control in Flow Cytometry
  publication-title: Current Protocols in Cytometry
– volume: 43
  year: 1999
– volume: 13
  start-page: 669
  issue: 7
  year: 1992
  end-page: 677
  article-title: Photo‐Bleaching and Photon Saturation in Flow Cytometry
  publication-title: Cytometry: The Journal of the International Society for Analytical Cytology
– volume: 107
  start-page: 339
  issue: 4
  year: 2002
  article-title: Quantitating Fluorescence Intensity From Fluorophores: Practical Use of Mesf Values
  publication-title: Journal of Research of the National Institute of Standards and Technology
– volume: 13
  start-page: 822
  issue: 8
  year: 1992
  end-page: 830
  article-title: Noise, Sensitivity, and Resolution of Flow Cytometers
  publication-title: Cytometry
– volume: 16
  issue: 3
  year: 2021
  article-title: Establishing cd19 b‐Cell Reference Control Materials for Comparable and Quantitative Cytometric Expression Analysis
  publication-title: PLoS One
– volume: 6
  start-page: 271
  year: 2002
  end-page: 292
  article-title: Semiparametric Deconvolution With Unknown Noise Variance
  publication-title: ESAIM Probability and Statistics
– volume: 5
  start-page: 1
  issue: 1
  year: 2006
  end-page: 11
  article-title: Applications of Cell Sorting in Biotechnology
  publication-title: Microbial Cell Factories
– volume: 62
  start-page: 23
  issue: 1
  year: 2000
  end-page: 35
  article-title: Hidden Truncation Models
  publication-title: Sankhyā: The Indian Journal of Statistics, Series A
– volume: 22
  start-page: 3217
  issue: 17
  year: 2022
  end-page: 3228
  article-title: Serial Flow Cytometry in an Inertial Focusing Optofluidic Microchip for Direct Assessment of Measurement Variations
  publication-title: Lab on a Chip
– volume: 33
  start-page: 256
  issue: 2
  year: 1998
  end-page: 259
  article-title: Evaluating Fluorescence Sensitivity on Flow Cytometers: An Overview
  publication-title: Cytometry
– volume: 62
  start-page: 1960
  issue: 7
  year: 2013
  end-page: 1971
  article-title: Statistics of Particle Detection From Single‐Channel Fluorescence Signals for Flow Cytometric Applications
  publication-title: IEEE Transactions on Instrumentation and Measurement
– volume: 20
  start-page: 9
  issue: 1
  year: 1992
  end-page: 21
  article-title: Gaussian Deconvolution via Differentiation
  publication-title: Canadian Journal of Statistics
– volume: 19
  start-page: 1257
  year: 1991
  end-page: 1272
  article-title: On the Optimal Rates of Convergence for Nonparametric Deconvolution Problems
  publication-title: Annals of Statistics
– start-page: 19
  year: 2007
  end-page: 39
– volume: 99
  start-page: 664
  issue: 7
  year: 2021
  end-page: 667
  article-title: How Well Can Your Flow Cytometer Detect Photons?
  publication-title: Cytometry, Part A
– volume: 33
  start-page: 267
  issue: 2
  year: 1998
  end-page: 279
  article-title: Resolution of Dimly Fluorescent Particles: A Practical Measure of Fluorescence Sensitivity
  publication-title: Cytometry
– volume: 97
  start-page: 105
  issue: 2
  year: 2020
  end-page: 106
  article-title: Special Issue on Enhancement of Reproducibility and Rigor
  publication-title: Cytometry, Part A
– volume: 121
  start-page: 264
  year: 2016
  article-title: Assignment of the Number of Equivalent Reference Fluorophores to Dyed Microspheres
  publication-title: Journal of Research of the National Institute of Standards and Technology
– volume: 69
  start-page: 385
  issue: 3
  year: 2001
  end-page: 398
  article-title: Idiot's Bayes—Not So Stupid After all?
  publication-title: International Statistical Review
– volume: 33
  start-page: 260
  issue: 2
  year: 1998
  end-page: 266
  article-title: Fundamental Flow Cytometer Properties Governing Sensitivity and Resolution
  publication-title: Cytometry
– volume: 412
  start-page: 7977
  year: 2020
  end-page: 7988
  article-title: Affine Analysis for Quantitative Pcr Measurements
  publication-title: Analytical and Bioanalytical Chemistry
– ident: e_1_2_10_21_1
  doi: 10.1111/j.1751-5823.2001.tb00465.x
– ident: e_1_2_10_12_1
  doi: 10.1002/cyto.a.24281
– ident: e_1_2_10_10_1
  doi: 10.1109/TIM.2013.2248293
– ident: e_1_2_10_11_1
  doi: 10.1002/(SICI)1097-0320(19981001)33:2<267::AID-CYTO24>3.0.CO;2-R
– ident: e_1_2_10_16_1
  doi: 10.1002/cyto.a.23972
– ident: e_1_2_10_22_1
  doi: 10.1371/journal.pone.0248118
– ident: e_1_2_10_9_1
  doi: 10.1039/D1LC01169C
– volume: 62
  start-page: 23
  issue: 1
  year: 2000
  ident: e_1_2_10_18_1
  article-title: Hidden Truncation Models
  publication-title: Sankhyā: The Indian Journal of Statistics, Series A
– ident: e_1_2_10_20_1
  doi: 10.1007/s00216-020-02930-z
– ident: e_1_2_10_14_1
  doi: 10.6028/jres.121.012
– ident: e_1_2_10_4_1
  doi: 10.1186/1475-2859-5-12
– ident: e_1_2_10_6_1
  doi: 10.1002/(SICI)1097-0320(19981001)33:2<256::AID-CYTO22>3.0.CO;2-S
– ident: e_1_2_10_7_1
  doi: 10.1002/cpcy.14
– ident: e_1_2_10_3_1
  doi: 10.1007/10_2007_073
– volume-title: Mathematical Methods of Statistics
  year: 1999
  ident: e_1_2_10_15_1
– ident: e_1_2_10_25_1
  doi: 10.2307/3315571
– ident: e_1_2_10_2_1
  doi: 10.3109/07388551.2015.1128876
– ident: e_1_2_10_17_1
– ident: e_1_2_10_13_1
  doi: 10.6028/jres.107.027
– ident: e_1_2_10_5_1
  doi: 10.1002/(SICI)1097-0320(19981001)33:2<260::AID-CYTO23>3.0.CO;2-R
– ident: e_1_2_10_23_1
  doi: 10.1214/aos/1176348248
– ident: e_1_2_10_8_1
  doi: 10.1002/cyto.990130804
– volume: 13
  start-page: 669
  issue: 7
  year: 1992
  ident: e_1_2_10_19_1
  article-title: Photo‐Bleaching and Photon Saturation in Flow Cytometry
  publication-title: Cytometry: The Journal of the International Society for Analytical Cytology
  doi: 10.1002/cyto.990130702
– ident: e_1_2_10_24_1
  doi: 10.1051/ps:2002015
SSID ssj0035032
Score 2.4202075
Snippet ABSTRACT In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise toward total measured variation....
In cytometry, it is difficult to disentangle the contributions of population variance and instrument noise toward total measured variation. Fundamentally, this...
SourceID proquest
pubmed
crossref
wiley
SourceType Aggregation Database
Index Database
Publisher
StartPage 248
SubjectTerms Affine transformations
beads
Cell Separation - instrumentation
Cell Separation - methods
FACS
Flow cytometry
Flow Cytometry - instrumentation
Flow Cytometry - methods
Flow rates
gating
Humans
sorting
Uncertainty
uncertainty quantification
Variation
Title Uncertainty Quantification in Flow Cytometry Using a Cell Sorter
URI https://onlinelibrary.wiley.com/doi/abs/10.1002%2Fcyto.a.24925
https://www.ncbi.nlm.nih.gov/pubmed/40135908
https://www.proquest.com/docview/3196020335
https://www.proquest.com/docview/3181370054
Volume 107
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1dS8MwFA0yEHzx-2M6JYI-dluTtF3eHMUxBBV1g_kU0iQFcXaydcj89eam3XQKgr4VkrRpbm5ykpyci9BZM7ApqSEeSSx8YyrVXoto3-OU-yriJNEG7jtf34TdPrsaBINyww3uwhT6EIsNN_AMN16Dg8tk0vgUDVWzfFSXdVC8gzvmQNcCTHS_UI-iQdPFJwORMc_mIiXv3RZvfC28PCP9gJnLqNVNO50NJOYVLtgmz_VpntTV-zctx___0SZaLxEpbhddaAutmGwbrRYxKmc76KJvu4WjDeQzfDeVBbnI2RM_ZbgzHL3h2L7yxeTjGXYMBCxxbIZD_ABE3vEu6ncue3HXK8MueIoSGnipYcqu-2RTB3biUiHnSlElEyI1VZoBc5ynMlQtbjiTsAKiPjNap1GqoyiQdA9VslFmDhAOE99XkvIErqFIxlsy1YxJoywMjJq-rqLzedOL10JdQxQ6ykRAawgpXGtUUW1uF1H62ETA4AHnqNQmny6SrXfAkYfMzGgKeVo-jQCXVtF-Yc_Fh2BlCRHfq8hzVvm1BiJ-7N223ePhH_MfoTUCQYMd3aeGKvl4ao4tksmTE9dfPwDDEu6a
linkProvider Wiley-Blackwell
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1Bb9MwFH4anRBcYGNs6xjMSHBM29hOUt82dasKtEWDVhonz7EdCa1Lp5Jq6n49fk5a1k1CQtwi2U4cPz_72f78fQAfWpFLySwNaOrCN64zE7SpCQPBRKgTQVNj8b7zYBj3xvzzRXRR6ZziXZiSH2K14Yae4cdrdHDckG7-YQ3Vi2LaUA2kvIuewCaKeiN5_um3FX8Ui1peoQxpxgKXjVbId1e-eb_0-pz0KNBcj1v9xNN9CZfLKpd4k6vGvEgb-u4Bm-N__NMWvKiCUnJS9qJt2LD5K3haylQuduB47HqGRw4UC3I-VyW-yJuU_MxJdzK9JR33ymtbzBbEgxCIIh07mZDviOWdvYZx92zU6QWV8kKgGWVRkFmu3dJPtUzk5i4dC6E10yqlyjBtOILHRaZi3RZWcIWLIBZya0yWZCZJIsV2oZZPc7sPJE7DUCsmUryJorhoq8xwrqx2kWDSCk0dPi7bXt6UBBuypFKmEltDKulbow6HS8PIys1-SRw_8CiVueT3q2TnIHjqoXI7nWOedsgSDE3rsFcadPUhXFyi6HsdAm-Wv9ZAdn6Mvp74x4N_zH8Ez3qjQV_2Pw2_vIHnFDWEPfrnEGrFbG7fusCmSN_5zvsbrm7ytg
linkToPdf http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1bT9swFD7ioiFegG1sdFzmSfCYkthOUr-BChW3sXGpBE-WYzsSoqSopELdr8fHSbvBJCR4i2Q7cXx87M_25-8AbIaxS8ktDWjm4BvXuQla1ESBYCLSqaCZsXjf-edpctDlR1fxVb3hhndhKn2IyYYbeoYfr9HB702-_Vc0VI_KflM1UfEunoZZnoQCQzfsnU_ko1gc-gBlqDIWuGy0Jr678tv_ln4-Jf2HM5_DVj_vdBZBjmtc0U1um8Mya-o_L8Qc3_9LS7BQQ1KyW_WhjzBli0_woQpSOfoMO13XLzxvoByRs6Gq2EXeoOSmIJ1e_5G03SvvbDkYEU9BIIq0ba9HLpDJO1iGbmf_sn0Q1HEXAs0oi4Pccu0Wfio0sZu5dCKE1kyrjCrDtOFIHRe5SnRLWMEVLoFYxK0xeZqbNI0V-wIzRb-wK0CSLIq0YiLDeyiKi5bKDefKaocD0zAyDdgaN728r-Q1ZCWkTCW2hlTSt0YD1sZ2kbWTPUgcPfAglbnkH5Nk5x545qEK2x9inlbEUgSmDfha2XPyIVxaYsj3BgTeKq_WQLavL3_t-sdvb8z_HeZ-73XkyeHp8SrMUwwg7Kk_azBTDoZ23aGaMtvwXfcJ5ofxZQ
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Uncertainty+Quantification+in+Flow+Cytometry+Using+a+Cell+Sorter&rft.jtitle=Cytometry.+Part+A&rft.au=Krishnaswamy%E2%80%90Usha%2C+Amudhan&rft.au=Cooksey%2C+Gregory+A.&rft.au=Patrone%2C+Paul+N.&rft.date=2025-04-01&rft.pub=John+Wiley+%26+Sons%2C+Inc&rft.issn=1552-4922&rft.eissn=1552-4930&rft.volume=107&rft.issue=4&rft.spage=248&rft.epage=262&rft_id=info:doi/10.1002%2Fcyto.a.24925&rft.externalDBID=10.1002%252Fcyto.a.24925&rft.externalDocID=CYTOA24925
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1552-4922&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1552-4922&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1552-4922&client=summon