Pre-flight calibration of a multi-angle polarimetric satellite sensor directional polarimetric camera

The directional polarimetric camera (DPC), developed by Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Science, is a satellite sensor used to observe the polarization and directionality of the earth’s reflectance. It acquires the two-dimensional image of the earth with a large fiel...

Full description

Saved in:
Bibliographic Details
Published inOptics express Vol. 28; no. 9; p. 13187
Main Authors Huang, Chan, Xiang, Guangfeng, Chang, Yuyang, Han, Lin, Zhang, Miaomiao, Li, Shuang, Tu, Bihai, Meng, Binghuan, Hong, Jin
Format Journal Article
LanguageEnglish
Published United States 27.04.2020
Online AccessGet full text
ISSN1094-4087
1094-4087
DOI10.1364/OE.391078

Cover

Abstract The directional polarimetric camera (DPC), developed by Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Science, is a satellite sensor used to observe the polarization and directionality of the earth’s reflectance. It acquires the two-dimensional image of the earth with a large field of view (118.74°) and a high spatial resolution (3.3 km) in 8 spectral bands. The first DPC was successfully launched onboard the GaoFen-5 satellite in May 2018, subject to the Chinese high-resolution earth observation program. In this paper, a set of systematic and complete pre-flight calibrations of the DPC are proposed to ensure the effective characterization for in-flight calibration, so as to ensure the accuracy of DPC measured radiation polarization data and the reliability of inversion results. Since the geometric calibration method of the DPC has been presented in an early companion paper [ Appl. Opt. 59 226 ( 2020 ) ], this paper will not introduce it in detail. Instead, the geometric calibration results of each spectral band together with a discussion on the origin of differences between spectral bands are analyzed, and the error analysis of the method is conducted. The results of the DPC geometric calibration is that the residuals of all spectral bands are less than 0.1 pixel. For radiometric calibration, the radiometric models of non-polarized bands and polarized bands are derived in detail, respectively, and the specific calibration methods with error analysis, equipment, and main results with their related accuracies for each parameter of the radiometric models are described. To verify the accuracy of calibration parameters, a series of polarization detection accuracy verification experiments based on a non-polarized radiation source, a polarizing system, and a natural scene were carried out. The experimental results show that the maximum deviation of degree of polarization between the set values of the polarizing system and measured values of the DPC at the corresponding positions of four field of view angles of 0, 15, 30, and 45 degrees of each polarized spectral band is 0.009, 0.004, and 0.003, respectively. The average error in measuring the degree of polarization of a non-polarized light source by all pixels in the three polarized bands is 0.0043, 0.0046, and 0.0037, respectively. And the relative deviations of each field of view are within 0.020 when the DPC and CE318N simultaneously measure the DoLP of sky. All of these prove the effectiveness of the pre-flight calibration.
AbstractList The directional polarimetric camera (DPC), developed by Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Science, is a satellite sensor used to observe the polarization and directionality of the earth’s reflectance. It acquires the two-dimensional image of the earth with a large field of view (118.74°) and a high spatial resolution (3.3 km) in 8 spectral bands. The first DPC was successfully launched onboard the GaoFen-5 satellite in May 2018, subject to the Chinese high-resolution earth observation program. In this paper, a set of systematic and complete pre-flight calibrations of the DPC are proposed to ensure the effective characterization for in-flight calibration, so as to ensure the accuracy of DPC measured radiation polarization data and the reliability of inversion results. Since the geometric calibration method of the DPC has been presented in an early companion paper [ Appl. Opt. 59 226 ( 2020 ) ], this paper will not introduce it in detail. Instead, the geometric calibration results of each spectral band together with a discussion on the origin of differences between spectral bands are analyzed, and the error analysis of the method is conducted. The results of the DPC geometric calibration is that the residuals of all spectral bands are less than 0.1 pixel. For radiometric calibration, the radiometric models of non-polarized bands and polarized bands are derived in detail, respectively, and the specific calibration methods with error analysis, equipment, and main results with their related accuracies for each parameter of the radiometric models are described. To verify the accuracy of calibration parameters, a series of polarization detection accuracy verification experiments based on a non-polarized radiation source, a polarizing system, and a natural scene were carried out. The experimental results show that the maximum deviation of degree of polarization between the set values of the polarizing system and measured values of the DPC at the corresponding positions of four field of view angles of 0, 15, 30, and 45 degrees of each polarized spectral band is 0.009, 0.004, and 0.003, respectively. The average error in measuring the degree of polarization of a non-polarized light source by all pixels in the three polarized bands is 0.0043, 0.0046, and 0.0037, respectively. And the relative deviations of each field of view are within 0.020 when the DPC and CE318N simultaneously measure the DoLP of sky. All of these prove the effectiveness of the pre-flight calibration.
The directional polarimetric camera (DPC), developed by Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Science, is a satellite sensor used to observe the polarization and directionality of the earth's reflectance. It acquires the two-dimensional image of the earth with a large field of view (118.74°) and a high spatial resolution (3.3 km) in 8 spectral bands. The first DPC was successfully launched onboard the GaoFen-5 satellite in May 2018, subject to the Chinese high-resolution earth observation program. In this paper, a set of systematic and complete pre-flight calibrations of the DPC are proposed to ensure the effective characterization for in-flight calibration, so as to ensure the accuracy of DPC measured radiation polarization data and the reliability of inversion results. Since the geometric calibration method of the DPC has been presented in an early companion paper [Appl. Opt. 59 226 (2020)], this paper will not introduce it in detail. Instead, the geometric calibration results of each spectral band together with a discussion on the origin of differences between spectral bands are analyzed, and the error analysis of the method is conducted. The results of the DPC geometric calibration is that the residuals of all spectral bands are less than 0.1 pixel. For radiometric calibration, the radiometric models of non-polarized bands and polarized bands are derived in detail, respectively, and the specific calibration methods with error analysis, equipment, and main results with their related accuracies for each parameter of the radiometric models are described. To verify the accuracy of calibration parameters, a series of polarization detection accuracy verification experiments based on a non-polarized radiation source, a polarizing system, and a natural scene were carried out. The experimental results show that the maximum deviation of degree of polarization between the set values of the polarizing system and measured values of the DPC at the corresponding positions of four field of view angles of 0, 15, 30, and 45 degrees of each polarized spectral band is 0.009, 0.004, and 0.003, respectively. The average error in measuring the degree of polarization of a non-polarized light source by all pixels in the three polarized bands is 0.0043, 0.0046, and 0.0037, respectively. And the relative deviations of each field of view are within 0.020 when the DPC and CE318N simultaneously measure the DoLP of sky. All of these prove the effectiveness of the pre-flight calibration.
The directional polarimetric camera (DPC), developed by Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Science, is a satellite sensor used to observe the polarization and directionality of the earth's reflectance. It acquires the two-dimensional image of the earth with a large field of view (118.74°) and a high spatial resolution (3.3 km) in 8 spectral bands. The first DPC was successfully launched onboard the GaoFen-5 satellite in May 2018, subject to the Chinese high-resolution earth observation program. In this paper, a set of systematic and complete pre-flight calibrations of the DPC are proposed to ensure the effective characterization for in-flight calibration, so as to ensure the accuracy of DPC measured radiation polarization data and the reliability of inversion results. Since the geometric calibration method of the DPC has been presented in an early companion paper [Appl. Opt. 59 226 (2020)], this paper will not introduce it in detail. Instead, the geometric calibration results of each spectral band together with a discussion on the origin of differences between spectral bands are analyzed, and the error analysis of the method is conducted. The results of the DPC geometric calibration is that the residuals of all spectral bands are less than 0.1 pixel. For radiometric calibration, the radiometric models of non-polarized bands and polarized bands are derived in detail, respectively, and the specific calibration methods with error analysis, equipment, and main results with their related accuracies for each parameter of the radiometric models are described. To verify the accuracy of calibration parameters, a series of polarization detection accuracy verification experiments based on a non-polarized radiation source, a polarizing system, and a natural scene were carried out. The experimental results show that the maximum deviation of degree of polarization between the set values of the polarizing system and measured values of the DPC at the corresponding positions of four field of view angles of 0, 15, 30, and 45 degrees of each polarized spectral band is 0.009, 0.004, and 0.003, respectively. The average error in measuring the degree of polarization of a non-polarized light source by all pixels in the three polarized bands is 0.0043, 0.0046, and 0.0037, respectively. And the relative deviations of each field of view are within 0.020 when the DPC and CE318N simultaneously measure the DoLP of sky. All of these prove the effectiveness of the pre-flight calibration.The directional polarimetric camera (DPC), developed by Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Science, is a satellite sensor used to observe the polarization and directionality of the earth's reflectance. It acquires the two-dimensional image of the earth with a large field of view (118.74°) and a high spatial resolution (3.3 km) in 8 spectral bands. The first DPC was successfully launched onboard the GaoFen-5 satellite in May 2018, subject to the Chinese high-resolution earth observation program. In this paper, a set of systematic and complete pre-flight calibrations of the DPC are proposed to ensure the effective characterization for in-flight calibration, so as to ensure the accuracy of DPC measured radiation polarization data and the reliability of inversion results. Since the geometric calibration method of the DPC has been presented in an early companion paper [Appl. Opt. 59 226 (2020)], this paper will not introduce it in detail. Instead, the geometric calibration results of each spectral band together with a discussion on the origin of differences between spectral bands are analyzed, and the error analysis of the method is conducted. The results of the DPC geometric calibration is that the residuals of all spectral bands are less than 0.1 pixel. For radiometric calibration, the radiometric models of non-polarized bands and polarized bands are derived in detail, respectively, and the specific calibration methods with error analysis, equipment, and main results with their related accuracies for each parameter of the radiometric models are described. To verify the accuracy of calibration parameters, a series of polarization detection accuracy verification experiments based on a non-polarized radiation source, a polarizing system, and a natural scene were carried out. The experimental results show that the maximum deviation of degree of polarization between the set values of the polarizing system and measured values of the DPC at the corresponding positions of four field of view angles of 0, 15, 30, and 45 degrees of each polarized spectral band is 0.009, 0.004, and 0.003, respectively. The average error in measuring the degree of polarization of a non-polarized light source by all pixels in the three polarized bands is 0.0043, 0.0046, and 0.0037, respectively. And the relative deviations of each field of view are within 0.020 when the DPC and CE318N simultaneously measure the DoLP of sky. All of these prove the effectiveness of the pre-flight calibration.
Author Zhang, Miaomiao
Meng, Binghuan
Hong, Jin
Xiang, Guangfeng
Li, Shuang
Han, Lin
Tu, Bihai
Chang, Yuyang
Huang, Chan
Author_xml – sequence: 1
  givenname: Chan
  surname: Huang
  fullname: Huang, Chan
– sequence: 2
  givenname: Guangfeng
  surname: Xiang
  fullname: Xiang, Guangfeng
– sequence: 3
  givenname: Yuyang
  surname: Chang
  fullname: Chang, Yuyang
– sequence: 4
  givenname: Lin
  surname: Han
  fullname: Han, Lin
– sequence: 5
  givenname: Miaomiao
  surname: Zhang
  fullname: Zhang, Miaomiao
– sequence: 6
  givenname: Shuang
  surname: Li
  fullname: Li, Shuang
– sequence: 7
  givenname: Bihai
  surname: Tu
  fullname: Tu, Bihai
– sequence: 8
  givenname: Binghuan
  surname: Meng
  fullname: Meng, Binghuan
– sequence: 9
  givenname: Jin
  surname: Hong
  fullname: Hong, Jin
BackLink https://www.ncbi.nlm.nih.gov/pubmed/32403798$$D View this record in MEDLINE/PubMed
BookMark eNptkD1PwzAQhi1URGlh4A8gjzCktRM3jkdUlQ-pUhlgji7OuRg5SbHdgX9PSgsCxHQ3PO_pvWdEBm3XIiEXnE14lovpajHJFGeyOCKnnCmRCFbIwY99SEYhvDLGhVTyhAyzVLBMquKU4KPHxDi7folUg7OVh2i7lnaGAm22LtoE2rVDuukceNtg9FbTABGdsxFpwDZ0ntbWo94Fwf0mNTTo4YwcG3ABzw9zTJ5vF0_z-2S5unuY3ywTnaUsJkLyLFXVrK5TIYSCuhJ9U2NkrutixosUMcUcodAq54rjzGS5qThCDiirWmZjcrW_u_Hd2xZDLBsbdF8VWuy2ody9zXohRd6jlwd0WzVYl5u-Mvj38ktND1zvAe27EDyab4Szcqe9XC3Kvfaenf5htY2fIqMH6_5JfAByDIU-
CitedBy_id crossref_primary_10_1364_OE_518266
crossref_primary_10_3390_rs15071933
crossref_primary_10_3390_rs14184548
crossref_primary_10_3390_rs13193823
crossref_primary_10_1016_j_ascom_2023_100772
crossref_primary_10_1109_TED_2022_3217716
crossref_primary_10_1109_TGRS_2024_3366702
crossref_primary_10_1364_OE_492041
crossref_primary_10_1109_TGRS_2022_3193095
crossref_primary_10_1364_OE_405834
crossref_primary_10_3390_rs14184571
crossref_primary_10_1016_j_rio_2021_100055
crossref_primary_10_1063_5_0237369
crossref_primary_10_1016_j_jqsrt_2021_107601
crossref_primary_10_3390_rs14051211
crossref_primary_10_1364_OE_410768
crossref_primary_10_1016_j_isprsjprs_2024_04_028
crossref_primary_10_1364_AO_422980
crossref_primary_10_1364_OE_523531
Cites_doi 10.1016/S0034-4257(98)00031-5
10.5194/amt-6-2007-2013
10.1364/AO.58.000744
10.1016/j.ijleo.2008.08.004
10.1364/AO.54.008241
10.1162/105474605774785325
10.1364/AO.55.010016
10.1364/OE.22.009442
10.1364/OE.23.001829
10.1364/AO.46.008428
10.1016/j.atmosenv.2004.01.046
10.1364/OE.26.014213
10.1364/AO.56.002368
10.1117/12.243226
10.1007/s00376-006-0008-3
10.1364/AO.58.002166
10.1364/OE.26.005478
10.1364/OE.19.018164
10.1364/OL.39.001505
10.1364/OE.22.023385
10.1364/JOSAA.17.001627
10.1063/1.2360786
10.3788/COL201513.041001
10.1364/AO.46.005435
10.1016/j.rse.2012.07.012
10.1029/2000JD900364
10.1016/j.jqsrt.2018.07.003
10.1016/j.imavis.2005.01.001
10.1364/AO.52.000C37
10.1016/S0165-1684(99)00042-0
10.1364/AO.54.004659
10.1364/AO.59.000226
10.1016/j.infrared.2017.09.021
10.1109/34.888718
10.1364/AO.58.005663
10.1364/OE.23.015205
10.1016/j.rse.2009.01.007
10.1117/12.221357
10.1016/j.jqsrt.2018.07.008
10.1029/96JD02109
10.1364/AO.58.007042
10.1364/AO.49.001249
10.1364/OE.16.020241
ContentType Journal Article
DBID AAYXX
CITATION
NPM
7X8
DOI 10.1364/OE.391078
DatabaseName CrossRef
PubMed
MEDLINE - Academic
DatabaseTitle CrossRef
PubMed
MEDLINE - Academic
DatabaseTitleList CrossRef
PubMed
MEDLINE - Academic
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Physics
EISSN 1094-4087
ExternalDocumentID 32403798
10_1364_OE_391078
Genre Journal Article
GroupedDBID ---
123
29N
2WC
8SL
AAFWJ
AAWJZ
AAYXX
ACGFO
ADBBV
AEDJG
AENEX
AFPKN
AKGWG
ALMA_UNASSIGNED_HOLDINGS
ATHME
AYPRP
AZSQR
AZYMN
BAWUL
BCNDV
CITATION
CS3
DIK
DSZJF
DU5
E3Z
EBS
F5P
GROUPED_DOAJ
GX1
KQ8
M~E
OFLFD
OK1
OPJBK
OPLUZ
OVT
P2P
RNS
ROL
ROS
TR2
TR6
XSB
NPM
ROP
7X8
ID FETCH-LOGICAL-c320t-471329b5dd24449adb4324ff76cd85182ee2e6ea8c96191e5f36fb1ea6ae7bd73
ISSN 1094-4087
IngestDate Fri Jul 11 09:55:10 EDT 2025
Wed Feb 19 02:29:56 EST 2025
Tue Jul 01 04:04:54 EDT 2025
Thu Apr 24 23:10:12 EDT 2025
IsDoiOpenAccess false
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 9
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c320t-471329b5dd24449adb4324ff76cd85182ee2e6ea8c96191e5f36fb1ea6ae7bd73
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
OpenAccessLink https://doi.org/10.1364/oe.391078
PMID 32403798
PQID 2403040886
PQPubID 23479
ParticipantIDs proquest_miscellaneous_2403040886
pubmed_primary_32403798
crossref_primary_10_1364_OE_391078
crossref_citationtrail_10_1364_OE_391078
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2020-04-27
2020-Apr-27
20200427
PublicationDateYYYYMMDD 2020-04-27
PublicationDate_xml – month: 04
  year: 2020
  text: 2020-04-27
  day: 27
PublicationDecade 2020
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Optics express
PublicationTitleAlternate Opt Express
PublicationYear 2020
References Yılmaztürk (oe-28-9-13187-R21) 2011; 19
Xiong (oe-28-9-13187-R32) 2006; 23
Huang (oe-28-9-13187-R40) 2019; 58
Chen (oe-28-9-13187-R15) 2019; 58
Diner (oe-28-9-13187-R38) 2007; 46
Roy (oe-28-9-13187-R42) 2000; 17
Sahin (oe-28-9-13187-R5) 2018; 26
Huang (oe-28-9-13187-R2) 2019; 58
Karyampudi (oe-28-9-13187-R44) 1998; 66
Li (oe-28-9-13187-R27) 2015; 23
Jia (oe-28-9-13187-R29) 2014; 22
Laherrere (oe-28-9-13187-R33) 1997
Fougnie (oe-28-9-13187-R36) 2007; 46
Fougnie (oe-28-9-13187-R37) 2018; 219
Li (oe-28-9-13187-R1) 2018; 218
Li (oe-28-9-13187-R13) 2018; 26
Alexandrov (oe-28-9-13187-R10) 2012; 125
Pedersini (oe-28-9-13187-R11) 1999; 77
Lucchese (oe-28-9-13187-R12) 2005; 23
Svoboda (oe-28-9-13187-R20) 2005; 14
Bian (oe-28-9-13187-R4) 2015; 54
Bauer (oe-28-9-13187-R16) 2008; 16
Herman (oe-28-9-13187-R7) 1997; 102
Li (oe-28-9-13187-R45) 2010; 49
Sun (oe-28-9-13187-R26) 2015; 54
Huang (oe-28-9-13187-R3) 2020; 59
Bret-Dibat (oe-28-9-13187-R23) 1995; 2553
Filacchione (oe-28-9-13187-R24) 2006; 77
Chen (oe-28-9-13187-R22) 2010; 121
Li (oe-28-9-13187-R19) 2017; 56
Hagolle (oe-28-9-13187-R34) 1996; 2758
Deuze (oe-28-9-13187-R8) 2001; 106
Vachon (oe-28-9-13187-R9) 2004; 38
Yazdani (oe-28-9-13187-R41) 2014; 39
Gao (oe-28-9-13187-R28) 2016; 55
Jia (oe-28-9-13187-R17) 2015; 23
Tu (oe-28-9-13187-R18) 2013; 52
Diner (oe-28-9-13187-R39) 2013; 6
Zhang (oe-28-9-13187-R14) 2000; 22
Bin (oe-28-9-13187-R6) 2017; 87
Shields (oe-28-9-13187-R30) 2019; 58
Li (oe-28-9-13187-R43) 2015; 13
Hlaing (oe-28-9-13187-R25) 2014; 22
Chander (oe-28-9-13187-R31) 2009; 113
References_xml – volume: 66
  start-page: 1
  year: 1998
  ident: oe-28-9-13187-R44
  publication-title: Remote Sens. Environ.
  doi: 10.1016/S0034-4257(98)00031-5
– volume: 6
  start-page: 2007
  year: 2013
  ident: oe-28-9-13187-R39
  publication-title: Atmos. Meas. Tech.
  doi: 10.5194/amt-6-2007-2013
– volume: 58
  start-page: 744
  year: 2019
  ident: oe-28-9-13187-R15
  publication-title: Appl. Opt.
  doi: 10.1364/AO.58.000744
– volume: 121
  start-page: 486
  year: 2010
  ident: oe-28-9-13187-R22
  publication-title: Optik
  doi: 10.1016/j.ijleo.2008.08.004
– volume: 54
  start-page: 8241
  year: 2015
  ident: oe-28-9-13187-R4
  publication-title: Appl. Opt.
  doi: 10.1364/AO.54.008241
– volume: 14
  start-page: 407
  year: 2005
  ident: oe-28-9-13187-R20
  publication-title: Presence-Teleop Virt.
  doi: 10.1162/105474605774785325
– volume: 55
  start-page: 10016
  year: 2016
  ident: oe-28-9-13187-R28
  publication-title: Appl. Opt.
  doi: 10.1364/AO.55.010016
– volume: 22
  start-page: 9442
  year: 2014
  ident: oe-28-9-13187-R29
  publication-title: Opt. Express
  doi: 10.1364/OE.22.009442
– volume: 23
  start-page: 1829
  year: 2015
  ident: oe-28-9-13187-R27
  publication-title: Opt. Express
  doi: 10.1364/OE.23.001829
– volume: 46
  start-page: 8428
  year: 2007
  ident: oe-28-9-13187-R38
  publication-title: Appl. Opt.
  doi: 10.1364/AO.46.008428
– volume: 38
  start-page: 3501
  year: 2004
  ident: oe-28-9-13187-R9
  publication-title: Atmos. Environ.
  doi: 10.1016/j.atmosenv.2004.01.046
– volume: 26
  start-page: 14213
  year: 2018
  ident: oe-28-9-13187-R13
  publication-title: Opt. Express
  doi: 10.1364/OE.26.014213
– volume: 56
  start-page: 2368
  year: 2017
  ident: oe-28-9-13187-R19
  publication-title: Appl. Opt.
  doi: 10.1364/AO.56.002368
– volume: 2758
  start-page: 308
  year: 1996
  ident: oe-28-9-13187-R34
  publication-title: Proc. Spie.
  doi: 10.1117/12.243226
– volume: 23
  start-page: 69
  year: 2006
  ident: oe-28-9-13187-R32
  publication-title: Adv. Atmos. Sci.
  doi: 10.1007/s00376-006-0008-3
– volume: 58
  start-page: 2166
  year: 2019
  ident: oe-28-9-13187-R40
  publication-title: Appl. Opt.
  doi: 10.1364/AO.58.002166
– volume: 26
  start-page: 5478
  year: 2018
  ident: oe-28-9-13187-R5
  publication-title: Opt. Express
  doi: 10.1364/OE.26.005478
– volume: 19
  start-page: 18164
  year: 2011
  ident: oe-28-9-13187-R21
  publication-title: Opt. Express
  doi: 10.1364/OE.19.018164
– volume: 39
  start-page: 1505
  year: 2014
  ident: oe-28-9-13187-R41
  publication-title: Opt. Lett.
  doi: 10.1364/OL.39.001505
– volume: 22
  start-page: 23385
  year: 2014
  ident: oe-28-9-13187-R25
  publication-title: Opt. Express
  doi: 10.1364/OE.22.023385
– volume: 17
  start-page: 1627
  year: 2000
  ident: oe-28-9-13187-R42
  publication-title: J. Opt. Soc. Am. A
  doi: 10.1364/JOSAA.17.001627
– volume: 77
  start-page: 103106
  year: 2006
  ident: oe-28-9-13187-R24
  publication-title: Rev. Sci. Instrum.
  doi: 10.1063/1.2360786
– volume: 13
  start-page: 041001
  year: 2015
  ident: oe-28-9-13187-R43
  publication-title: Chin. Opt. Lett.
  doi: 10.3788/COL201513.041001
– volume: 46
  start-page: 5435
  year: 2007
  ident: oe-28-9-13187-R36
  publication-title: Appl. Opt.
  doi: 10.1364/AO.46.005435
– volume: 125
  start-page: 92
  year: 2012
  ident: oe-28-9-13187-R10
  publication-title: Remote Sens. Environ.
  doi: 10.1016/j.rse.2012.07.012
– volume: 106
  start-page: 4913
  year: 2001
  ident: oe-28-9-13187-R8
  publication-title: J. Geophys. Res-Atmos
  doi: 10.1029/2000JD900364
– volume: 218
  start-page: 21
  year: 2018
  ident: oe-28-9-13187-R1
  publication-title: J. Quant. Spectrosc. Radiat. Transfer
  doi: 10.1016/j.jqsrt.2018.07.003
– volume: 23
  start-page: 517
  year: 2005
  ident: oe-28-9-13187-R12
  publication-title: Image Vision Comput.
  doi: 10.1016/j.imavis.2005.01.001
– start-page: 3221
  volume-title: International Society for Optics and Photonics 1997
  year: 1997
  ident: oe-28-9-13187-R33
– volume: 52
  start-page: C37
  year: 2013
  ident: oe-28-9-13187-R18
  publication-title: Appl. Opt.
  doi: 10.1364/AO.52.000C37
– volume: 77
  start-page: 309
  year: 1999
  ident: oe-28-9-13187-R11
  publication-title: Signal Process.
  doi: 10.1016/S0165-1684(99)00042-0
– volume: 54
  start-page: 4659
  year: 2015
  ident: oe-28-9-13187-R26
  publication-title: Appl. Opt.
  doi: 10.1364/AO.54.004659
– volume: 59
  start-page: 226
  year: 2020
  ident: oe-28-9-13187-R3
  publication-title: Appl. Opt.
  doi: 10.1364/AO.59.000226
– volume: 87
  start-page: 11
  year: 2017
  ident: oe-28-9-13187-R6
  publication-title: Infrared Phys. Technol.
  doi: 10.1016/j.infrared.2017.09.021
– volume: 22
  start-page: 1330
  year: 2000
  ident: oe-28-9-13187-R14
  publication-title: IEEE T. Pattern Anal.
  doi: 10.1109/34.888718
– volume: 58
  start-page: 5663
  year: 2019
  ident: oe-28-9-13187-R30
  publication-title: Appl. Opt.
  doi: 10.1364/AO.58.005663
– volume: 23
  start-page: 15205
  year: 2015
  ident: oe-28-9-13187-R17
  publication-title: Opt. Express
  doi: 10.1364/OE.23.015205
– volume: 113
  start-page: 893
  year: 2009
  ident: oe-28-9-13187-R31
  publication-title: Remote Sens. Environ.
  doi: 10.1016/j.rse.2009.01.007
– volume: 2553
  start-page: 218
  year: 1995
  ident: oe-28-9-13187-R23
  publication-title: Proc SPIE
  doi: 10.1117/12.221357
– volume: 219
  start-page: 23
  year: 2018
  ident: oe-28-9-13187-R37
  publication-title: J. Quant. Spectrosc. Radiat. Transfer
  doi: 10.1016/j.jqsrt.2018.07.008
– volume: 102
  start-page: 17039
  year: 1997
  ident: oe-28-9-13187-R7
  publication-title: J. Geophys. Res.
  doi: 10.1029/96JD02109
– volume: 58
  start-page: 7042
  year: 2019
  ident: oe-28-9-13187-R2
  publication-title: Appl. Opt.
  doi: 10.1364/AO.58.007042
– volume: 49
  start-page: 1249
  year: 2010
  ident: oe-28-9-13187-R45
  publication-title: Appl. Opt.
  doi: 10.1364/AO.49.001249
– volume: 16
  start-page: 20241
  year: 2008
  ident: oe-28-9-13187-R16
  publication-title: Opt. Express
  doi: 10.1364/OE.16.020241
SSID ssj0014797
Score 2.4526117
Snippet The directional polarimetric camera (DPC), developed by Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Science, is a satellite sensor used to...
SourceID proquest
pubmed
crossref
SourceType Aggregation Database
Index Database
Enrichment Source
StartPage 13187
Title Pre-flight calibration of a multi-angle polarimetric satellite sensor directional polarimetric camera
URI https://www.ncbi.nlm.nih.gov/pubmed/32403798
https://www.proquest.com/docview/2403040886
Volume 28
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3di9NAEF_0RPBF_LanHqv4IJSczW6y2X0UqRbhrA93UJ_CZjN7CKUtbQqeD_7tzn4kTbXC6Usok01Sdn7MzszO_JaQ1yxnBUYBJlFyZJJMpTxRwPOEc6ikBaZ57Rqczz6LyUX2aZbPdiVBvrukqU7Nj4N9Jf-jVZShXl2X7D9otnspCvA36hevqGG8XkvHX9aQ2LkLr4c41S7wbf0_HSoFE724nIM7iUE7Gn_Hxj_caE_C2cBwgyHscj0Mq1pICe6NNNplrPru63TlWZ3h-6qr3PCQiEln16rQCmffovCju2shrpChkiDc-bq90jvxJHZBRCrwmIlgriw0CY390XhiqIjxaFxA4YAsWlwme8hSPfOZooUpDhp2LjLUxnR8ytG_CYf-7JNn_7aodaWGfsdOZOV0XIZHb5JbrCj8lv7Zz3G345QV4SCe9v9GFip89G331X3f5S8BiXdMzu-RuzGioO8CPO6TG7B4QG77yl6zeUhgBxLaAwldWqppDyS0r3ragYQGkNAeSPZHBpA8IhcfxufvJ0k8WyMxnI2aBH0SzlSV1zX6d5nSdeWoGa0thKnRCZcMgIEALY3CEDuF3HJhqxS00FBUdcEfk6PFcgFPCbVGyXzEtTI2z-rKKD0S0oCQoLmGNBuQN-2slSYSz7vzT-blH7oZkFfd0FVgWzk06GU79SXaQrfBpRew3G5Kxy2Ji5KUYkCeBJ10r_HEk4WSx9f5xDNyZwfw5-SoWW_hBTqfTXXikzYnHju_AFRDiMU
linkProvider ISSN International Centre
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Pre-flight+calibration+of+a+multi-angle+polarimetric+satellite+sensor+directional+polarimetric+camera&rft.jtitle=Optics+express&rft.au=Huang%2C+Chan&rft.au=Xiang%2C+Guangfeng&rft.au=Chang%2C+Yuyang&rft.au=Han%2C+Lin&rft.date=2020-04-27&rft.issn=1094-4087&rft.eissn=1094-4087&rft.volume=28&rft.issue=9&rft.spage=13187&rft_id=info:doi/10.1364%2FOE.391078&rft.externalDBID=n%2Fa&rft.externalDocID=10_1364_OE_391078
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1094-4087&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1094-4087&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1094-4087&client=summon