Left ventricular volume determination from single-photon emission computed tomography

To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic volume, 25 consecutive patients undergoing catheterization for coronary artery or valvular heart disease were first evaluated scintigraphica...

Full description

Saved in:
Bibliographic Details
Published inAmerican journal of roentgenology (1976) Vol. 144; no. 2; pp. 295 - 298
Main Authors Bunker, , SR, Hartshorne, MF, Schmidt, WP, Cawthon, MA, Karl, RD, Jr, Bauman, JM, Howard, WH, 3rd, Rubal, BJ
Format Journal Article
LanguageEnglish
Published United States Am Roentgen Ray Soc 01.02.1985
Subjects
Online AccessGet full text

Cover

Loading…
Abstract To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic volume, 25 consecutive patients undergoing catheterization for coronary artery or valvular heart disease were first evaluated scintigraphically. A simple, count-corrected voxel counting technique was used to derive left ventricular end-diastolic volume from transaxial SPECT slices. SPECT volume values showed a high degree of correlation with those determined by angiography (r = 0.969), with a standard error of the estimate of 23 ml. SPECT offers a highly accurate and essentially noninvasive method for measuring chamber volumes that is independent of geometric assumptions about ventricular configuration and chest wall attenuation and does not require blood sample counting.
AbstractList To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic volume, 25 consecutive patients undergoing catheterization for coronary artery or valvular heart disease were first evaluated scintigraphically. A simple, count-corrected voxel counting technique was used to derive left ventricular end-diastolic volume from transaxial SPECT slices. SPECT volume values showed a high degree of correlation with those determined by angiography (r = 0.969), with a standard error of the estimate of 23 ml. SPECT offers a highly accurate and essentially noninvasive method for measuring chamber volumes that is independent of geometric assumptions about ventricular configuration and chest wall attenuation and does not require blood sample counting.
Author Bunker, , SR
Schmidt, WP
Rubal, BJ
Karl, RD, Jr
Howard, WH, 3rd
Hartshorne, MF
Bauman, JM
Cawthon, MA
Author_xml – sequence: 1
  fullname: Bunker, , SR
– sequence: 2
  fullname: Hartshorne, MF
– sequence: 3
  fullname: Schmidt, WP
– sequence: 4
  fullname: Cawthon, MA
– sequence: 5
  fullname: Karl, RD, Jr
– sequence: 6
  fullname: Bauman, JM
– sequence: 7
  fullname: Howard, WH, 3rd
– sequence: 8
  fullname: Rubal, BJ
BackLink https://www.ncbi.nlm.nih.gov/pubmed/2981459$$D View this record in MEDLINE/PubMed
BookMark eNpFkLtrwzAQh0VpSZO0Y8eCp2529fJDYwl9QaBLCt2EYp9jB8tyJTkh_30VEprp4O7jd3ffDF33pgeEHghOKCX8WW1tQjhPaEJFeoWmJOVZzAgn12iKWUbiArOfWzRzbosxzguRT9CEioLwVEzR9xJqH-2g97Ytx07ZaGe6UUNUgQer21751vRRbY2OXNtvOoiHxvjQAt06d5yVRg-jhyryRpuNVUNzuEM3teoc3J_rHK3eXleLj3j59f65eFnGJSPCxxmDQnAhOOUZUCpyVYqaclavKU3XmEIuwmcpgTJjFaFpSRkXa0agyos6y9gcPZ1iB2t-R3BehptK6DrVgxmdzFNBU5LhAMYnsLTGOQu1HGyrlT1IguXRogwWZdglqQwWA_94Dh7XGqp_-qztsrhpN82-tSCdVl0XaCL3-_0l6A9Bln2b
CitedBy_id crossref_primary_10_1007_BF00293533
crossref_primary_10_1016_S0733_8651_18_30417_X
crossref_primary_10_1016_S0001_2998_89_80032_7
crossref_primary_10_1007_BF02577349
crossref_primary_10_1109_TMI_2004_825638
crossref_primary_10_1007_BF01745229
crossref_primary_10_1016_0002_9149_85_91136_1
crossref_primary_10_1016_S0001_2998_87_80034_X
crossref_primary_10_1109_23_289384
crossref_primary_10_1007_s00259_007_0496_0
crossref_primary_10_1016_S0009_9260_98_80124_4
crossref_primary_10_1016_S1071_3581_99_90022_3
crossref_primary_10_1016_S0146_2806_06_80013_7
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
AAYXX
CITATION
7X8
DOI 10.2214/ajr.144.2.295
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
CrossRef
MEDLINE - Academic
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
CrossRef
MEDLINE - Academic
DatabaseTitleList MEDLINE - Academic
MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1546-3141
EndPage 298
ExternalDocumentID 10_2214_ajr_144_2_295
2981459
www144_2_295
Genre Journal Article
Comparative Study
GroupedDBID -
08R
23M
2WC
3O-
53G
55
5GY
5RE
AAWTL
ABFLS
ABOCM
ADACO
ADBBV
AENEX
AFFNX
AJYGW
ALMA_UNASSIGNED_HOLDINGS
BAWUL
C1A
CS3
DD
DIK
E3Z
EBS
EJD
F5P
GJ
GX1
H13
J5H
L7B
LSO
O0-
P2P
SJN
TRR
UDS
VH1
W2D
WH7
WOQ
X7M
YQJ
ZA5
ZGI
ZXP
---
-DD
.55
.GJ
1CY
1KJ
34G
39C
AAEJM
ACRZS
AI.
AJJEV
CGR
CUY
CVF
ECM
EIF
MJL
NPM
TR2
TWZ
W8F
YJK
YQI
ZVN
AAYXX
CITATION
7X8
ID FETCH-LOGICAL-c319t-63e894994246e2297ac9f243fb225b02e7914451ec63d125c2349b31ed78f663
ISSN 0361-803X
IngestDate Sat Oct 05 05:56:22 EDT 2024
Fri Aug 23 02:09:45 EDT 2024
Sat Sep 28 07:28:35 EDT 2024
Tue Nov 10 19:29:39 EST 2020
IsPeerReviewed true
IsScholarly true
Issue 2
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c319t-63e894994246e2297ac9f243fb225b02e7914451ec63d125c2349b31ed78f663
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
PMID 2981459
PQID 75925160
PQPubID 23479
PageCount 4
ParticipantIDs proquest_miscellaneous_75925160
crossref_primary_10_2214_ajr_144_2_295
pubmed_primary_2981459
highwire_smallpub1_www144_2_295
PublicationCentury 1900
PublicationDate 1985-Feb
PublicationDateYYYYMMDD 1985-02-01
PublicationDate_xml – month: 02
  year: 1985
  text: 1985-Feb
PublicationDecade 1980
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle American journal of roentgenology (1976)
PublicationTitleAlternate AJR Am J Roentgenol
PublicationYear 1985
Publisher Am Roentgen Ray Soc
Publisher_xml – name: Am Roentgen Ray Soc
SSID ssj0007897
Score 1.4067161
Snippet To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic...
SourceID proquest
crossref
pubmed
highwire
SourceType Aggregation Database
Index Database
Publisher
StartPage 295
SubjectTerms Adult
Aged
Cardiac Output
Cineangiography
Female
Heart - diagnostic imaging
Humans
Male
Middle Aged
Models, Structural
Sodium Pertechnetate Tc 99m
Stroke Volume
Tomography, Emission-Computed
Title Left ventricular volume determination from single-photon emission computed tomography
URI http://www.ajronline.org/cgi/content/abstract/144/2/295
https://www.ncbi.nlm.nih.gov/pubmed/2981459
https://search.proquest.com/docview/75925160
Volume 144
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lj5swELbarVT1UvW1arp9-FD1EpGCMRCO29VuoyrZHkrU3CzwQ2mVwCohirS_vjMYB1K16uOCEAIDM5_G4_HMN4S81RxmYSN9z6QRkmqbwst9FXjgIZlIc8mSAgP6s-t4MuefFtGiKyFoqkvqYiRvf1lX8j9ahWugV6yS_QfNHgaFC3AO-oUjaBiOf6XjqTb1EBMWmyhevhlaWzNULsfFJhJiBQmGBFbau1lWyKOBTd4wTNZklO_Q6ayrdZ-82vHSuv2cHsHEpoIXIrVrQ96EPE_ga_QCCh92ZZup8aXLRpzA12-XVRs_nfXyieVy_U01M8HXrtbsIt8jp4G997yLTATpOHLJzKaryAKl-02_387aWrrHFlasbzttt812Gma2OfXPFp6xgOP09X2D29IjNjo81WfSvv4srubTqcguF9ldcg9JErGvwsdFl_6TjJvGO4dvtPyrOPz7o8GP_RXHIf379Ujjl2SPyMN2QUHPLToekzu6fELuz9qUiadkjiChPZBQKyJ6BBKKIKFHIKEOJNSBhHYgeUayq8vsYuK1vTQ8CUa29uJQj5GHiDMea8bSJJepYTw0BRj0wmc6SQPkqtMyDhU4vZKFPC3CQKtkbMArPSUnZVXq54QacNhzxVQSa8l1wAsw4YFUygRGJamvB-SdE5i4sYwpAlaaKFkBkoW1JhdMgGQH5I0Tp9iu89UKxBiI_X7fv8NJWcAv41ZWXupqtxVJlIJjHvsDcmqFf3gV4CbgUfrij4-ekQcdaF-Sk3qz06_AwayL1w1SfgBUTX8I
link.rule.ids 314,780,784,27924,27925
linkProvider Geneva Foundation for Medical Education and Research
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Left+ventricular+volume+determination+from+single-photon+emission+computed+tomography&rft.jtitle=American+journal+of+roentgenology+%281976%29&rft.au=Bunker%2C+S+R&rft.au=Hartshorne%2C+M+F&rft.au=Schmidt%2C+W+P&rft.au=Cawthon%2C+M+A&rft.date=1985-02-01&rft.issn=0361-803X&rft.volume=144&rft.issue=2&rft.spage=295&rft.epage=298&rft_id=info:doi/10.2214%2Fajr.144.2.295&rft.externalDBID=NO_FULL_TEXT
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0361-803X&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0361-803X&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0361-803X&client=summon