Left ventricular volume determination from single-photon emission computed tomography
To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic volume, 25 consecutive patients undergoing catheterization for coronary artery or valvular heart disease were first evaluated scintigraphica...
Saved in:
Published in | American journal of roentgenology (1976) Vol. 144; no. 2; pp. 295 - 298 |
---|---|
Main Authors | , , , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
Am Roentgen Ray Soc
01.02.1985
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic volume, 25 consecutive patients undergoing catheterization for coronary artery or valvular heart disease were first evaluated scintigraphically. A simple, count-corrected voxel counting technique was used to derive left ventricular end-diastolic volume from transaxial SPECT slices. SPECT volume values showed a high degree of correlation with those determined by angiography (r = 0.969), with a standard error of the estimate of 23 ml. SPECT offers a highly accurate and essentially noninvasive method for measuring chamber volumes that is independent of geometric assumptions about ventricular configuration and chest wall attenuation and does not require blood sample counting. |
---|---|
AbstractList | To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic volume, 25 consecutive patients undergoing catheterization for coronary artery or valvular heart disease were first evaluated scintigraphically. A simple, count-corrected voxel counting technique was used to derive left ventricular end-diastolic volume from transaxial SPECT slices. SPECT volume values showed a high degree of correlation with those determined by angiography (r = 0.969), with a standard error of the estimate of 23 ml. SPECT offers a highly accurate and essentially noninvasive method for measuring chamber volumes that is independent of geometric assumptions about ventricular configuration and chest wall attenuation and does not require blood sample counting. |
Author | Bunker, , SR Schmidt, WP Rubal, BJ Karl, RD, Jr Howard, WH, 3rd Hartshorne, MF Bauman, JM Cawthon, MA |
Author_xml | – sequence: 1 fullname: Bunker, , SR – sequence: 2 fullname: Hartshorne, MF – sequence: 3 fullname: Schmidt, WP – sequence: 4 fullname: Cawthon, MA – sequence: 5 fullname: Karl, RD, Jr – sequence: 6 fullname: Bauman, JM – sequence: 7 fullname: Howard, WH, 3rd – sequence: 8 fullname: Rubal, BJ |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/2981459$$D View this record in MEDLINE/PubMed |
BookMark | eNpFkLtrwzAQh0VpSZO0Y8eCp2529fJDYwl9QaBLCt2EYp9jB8tyJTkh_30VEprp4O7jd3ffDF33pgeEHghOKCX8WW1tQjhPaEJFeoWmJOVZzAgn12iKWUbiArOfWzRzbosxzguRT9CEioLwVEzR9xJqH-2g97Ytx07ZaGe6UUNUgQer21751vRRbY2OXNtvOoiHxvjQAt06d5yVRg-jhyryRpuNVUNzuEM3teoc3J_rHK3eXleLj3j59f65eFnGJSPCxxmDQnAhOOUZUCpyVYqaclavKU3XmEIuwmcpgTJjFaFpSRkXa0agyos6y9gcPZ1iB2t-R3BehptK6DrVgxmdzFNBU5LhAMYnsLTGOQu1HGyrlT1IguXRogwWZdglqQwWA_94Dh7XGqp_-qztsrhpN82-tSCdVl0XaCL3-_0l6A9Bln2b |
CitedBy_id | crossref_primary_10_1007_BF00293533 crossref_primary_10_1016_S0733_8651_18_30417_X crossref_primary_10_1016_S0001_2998_89_80032_7 crossref_primary_10_1007_BF02577349 crossref_primary_10_1109_TMI_2004_825638 crossref_primary_10_1007_BF01745229 crossref_primary_10_1016_0002_9149_85_91136_1 crossref_primary_10_1016_S0001_2998_87_80034_X crossref_primary_10_1109_23_289384 crossref_primary_10_1007_s00259_007_0496_0 crossref_primary_10_1016_S0009_9260_98_80124_4 crossref_primary_10_1016_S1071_3581_99_90022_3 crossref_primary_10_1016_S0146_2806_06_80013_7 |
ContentType | Journal Article |
DBID | CGR CUY CVF ECM EIF NPM AAYXX CITATION 7X8 |
DOI | 10.2214/ajr.144.2.295 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed CrossRef MEDLINE - Academic |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) CrossRef MEDLINE - Academic |
DatabaseTitleList | MEDLINE - Academic MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1546-3141 |
EndPage | 298 |
ExternalDocumentID | 10_2214_ajr_144_2_295 2981459 www144_2_295 |
Genre | Journal Article Comparative Study |
GroupedDBID | - 08R 23M 2WC 3O- 53G 55 5GY 5RE AAWTL ABFLS ABOCM ADACO ADBBV AENEX AFFNX AJYGW ALMA_UNASSIGNED_HOLDINGS BAWUL C1A CS3 DD DIK E3Z EBS EJD F5P GJ GX1 H13 J5H L7B LSO O0- P2P SJN TRR UDS VH1 W2D WH7 WOQ X7M YQJ ZA5 ZGI ZXP --- -DD .55 .GJ 1CY 1KJ 34G 39C AAEJM ACRZS AI. AJJEV CGR CUY CVF ECM EIF MJL NPM TR2 TWZ W8F YJK YQI ZVN AAYXX CITATION 7X8 |
ID | FETCH-LOGICAL-c319t-63e894994246e2297ac9f243fb225b02e7914451ec63d125c2349b31ed78f663 |
ISSN | 0361-803X |
IngestDate | Sat Oct 05 05:56:22 EDT 2024 Fri Aug 23 02:09:45 EDT 2024 Sat Sep 28 07:28:35 EDT 2024 Tue Nov 10 19:29:39 EST 2020 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 2 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c319t-63e894994246e2297ac9f243fb225b02e7914451ec63d125c2349b31ed78f663 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
PMID | 2981459 |
PQID | 75925160 |
PQPubID | 23479 |
PageCount | 4 |
ParticipantIDs | proquest_miscellaneous_75925160 crossref_primary_10_2214_ajr_144_2_295 pubmed_primary_2981459 highwire_smallpub1_www144_2_295 |
PublicationCentury | 1900 |
PublicationDate | 1985-Feb |
PublicationDateYYYYMMDD | 1985-02-01 |
PublicationDate_xml | – month: 02 year: 1985 text: 1985-Feb |
PublicationDecade | 1980 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | American journal of roentgenology (1976) |
PublicationTitleAlternate | AJR Am J Roentgenol |
PublicationYear | 1985 |
Publisher | Am Roentgen Ray Soc |
Publisher_xml | – name: Am Roentgen Ray Soc |
SSID | ssj0007897 |
Score | 1.4067161 |
Snippet | To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic... |
SourceID | proquest crossref pubmed highwire |
SourceType | Aggregation Database Index Database Publisher |
StartPage | 295 |
SubjectTerms | Adult Aged Cardiac Output Cineangiography Female Heart - diagnostic imaging Humans Male Middle Aged Models, Structural Sodium Pertechnetate Tc 99m Stroke Volume Tomography, Emission-Computed |
Title | Left ventricular volume determination from single-photon emission computed tomography |
URI | http://www.ajronline.org/cgi/content/abstract/144/2/295 https://www.ncbi.nlm.nih.gov/pubmed/2981459 https://search.proquest.com/docview/75925160 |
Volume | 144 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lj5swELbarVT1UvW1arp9-FD1EpGCMRCO29VuoyrZHkrU3CzwQ2mVwCohirS_vjMYB1K16uOCEAIDM5_G4_HMN4S81RxmYSN9z6QRkmqbwst9FXjgIZlIc8mSAgP6s-t4MuefFtGiKyFoqkvqYiRvf1lX8j9ahWugV6yS_QfNHgaFC3AO-oUjaBiOf6XjqTb1EBMWmyhevhlaWzNULsfFJhJiBQmGBFbau1lWyKOBTd4wTNZklO_Q6ayrdZ-82vHSuv2cHsHEpoIXIrVrQ96EPE_ga_QCCh92ZZup8aXLRpzA12-XVRs_nfXyieVy_U01M8HXrtbsIt8jp4G997yLTATpOHLJzKaryAKl-02_387aWrrHFlasbzttt812Gma2OfXPFp6xgOP09X2D29IjNjo81WfSvv4srubTqcguF9ldcg9JErGvwsdFl_6TjJvGO4dvtPyrOPz7o8GP_RXHIf379Ujjl2SPyMN2QUHPLToekzu6fELuz9qUiadkjiChPZBQKyJ6BBKKIKFHIKEOJNSBhHYgeUayq8vsYuK1vTQ8CUa29uJQj5GHiDMea8bSJJepYTw0BRj0wmc6SQPkqtMyDhU4vZKFPC3CQKtkbMArPSUnZVXq54QacNhzxVQSa8l1wAsw4YFUygRGJamvB-SdE5i4sYwpAlaaKFkBkoW1JhdMgGQH5I0Tp9iu89UKxBiI_X7fv8NJWcAv41ZWXupqtxVJlIJjHvsDcmqFf3gV4CbgUfrij4-ekQcdaF-Sk3qz06_AwayL1w1SfgBUTX8I |
link.rule.ids | 314,780,784,27924,27925 |
linkProvider | Geneva Foundation for Medical Education and Research |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Left+ventricular+volume+determination+from+single-photon+emission+computed+tomography&rft.jtitle=American+journal+of+roentgenology+%281976%29&rft.au=Bunker%2C+S+R&rft.au=Hartshorne%2C+M+F&rft.au=Schmidt%2C+W+P&rft.au=Cawthon%2C+M+A&rft.date=1985-02-01&rft.issn=0361-803X&rft.volume=144&rft.issue=2&rft.spage=295&rft.epage=298&rft_id=info:doi/10.2214%2Fajr.144.2.295&rft.externalDBID=NO_FULL_TEXT |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0361-803X&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0361-803X&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0361-803X&client=summon |