Bronopol as an Ingredient of a New Test Mixture for Evaluation of HPLC Columns
Different tests, including analytes or mixtures characterized by specific properties, can be used for the evaluation of chromatographic columns. High performance liquid chromatographic (HPLC) columns with chemically modified surfaces, purchased from different producers, were tested in our studies. C...
Saved in:
Published in | Journal of liquid chromatography & related technologies Vol. 26; no. 5; pp. 737 - 750 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
Colchester
Taylor & Francis Group
01.04.2003
Taylor & Francis |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Different tests, including analytes or mixtures characterized by specific properties, can be used for the evaluation of chromatographic columns. High performance liquid chromatographic (HPLC) columns with chemically modified surfaces, purchased from different producers, were tested in our studies. Characteristic chromatographic parameters, such as: number of plate theoretical (N
T
), reduced plate height (h), the retention factor (k), resolution (R
S
), and asymmetry factor (f
AS
) were determined. Bronopol (2-bromo-2-nitrpropane-1,3-diol) was suggested for column evaluation, especially as regards the homogeneity of adsorbent surface coverage by chemically bonded phase and spacing of residual silanols. This analyte was used separately, and in a mixture consisting of other analytes (uracil, acetophenone, benzene, toluene) with different physicochemical properties. |
---|---|
AbstractList | Different tests, including analytes or mixtures characterized by specific properties, can be used for the evaluation of chromatographic columns. High performance liquid chromatographic (HPLC) columns with chemically modified surfaces, purchased from different producers, were tested in our studies. Characteristic chromatographic parameters, such as: number of plate theoretical (N
T
), reduced plate height (h), the retention factor (k), resolution (R
S
), and asymmetry factor (f
AS
) were determined. Bronopol (2-bromo-2-nitrpropane-1,3-diol) was suggested for column evaluation, especially as regards the homogeneity of adsorbent surface coverage by chemically bonded phase and spacing of residual silanols. This analyte was used separately, and in a mixture consisting of other analytes (uracil, acetophenone, benzene, toluene) with different physicochemical properties. |
Author | Buszewski, Boguslaw Gadzala-Kopciuch, Renata M. Cendrowska, Iwona Krupczynska, Katarzyna |
Author_xml | – sequence: 1 givenname: Boguslaw surname: Buszewski fullname: Buszewski, Boguslaw email: bbusz@chem.uni.torun.pl organization: Department of Environmental Chemistry and Ecoanalytics, Faculty of Chemistry , Nicholas Copernicus University – sequence: 2 givenname: Iwona surname: Cendrowska fullname: Cendrowska, Iwona organization: Pharmaceutical Company GEMI – sequence: 3 givenname: Katarzyna surname: Krupczynska fullname: Krupczynska, Katarzyna organization: Department of Environmental Chemistry and Ecoanalytics, Faculty of Chemistry , Nicholas Copernicus University – sequence: 4 givenname: Renata M. surname: Gadzala-Kopciuch fullname: Gadzala-Kopciuch, Renata M. organization: Department of Environmental Chemistry and Ecoanalytics, Faculty of Chemistry , Nicholas Copernicus University |
BackLink | http://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=14652645$$DView record in Pascal Francis |
BookMark | eNptkD1PwzAQhi0EEm1hZPfCGPA5dpIVokKLQmEoElt0cWwUlNqVnVL673FVPhamu-F57_Q-Y3JsndWEXAC7AlbA9UNVJsAZg0JAcURGIDlLZM5fj-POCp5kLM9OyTiE9wjlkssRWdx6Z93a9RQDRUvn9s3rttN2oM5QpAu9pUsdBvrYfQ4br6lxnk4_sN_g0Dm7h2bPVUlL129WNpyRE4N90Offc0Je7qbLcpZUT_fz8qZKVApiSAppNCjOMzAgW80yIfImbYtGZA3GCq3AlivRSGCpMoC5BKO1bETeQqMQ0glJDneVdyF4beq171bodzWwei-jjjLqXxmRvzzwawwKe-PRqi78hUQmeSZk5IoD19lYdIVb5_u2HnDXO_8TSv9_8QX1RnIy |
CODEN | JLCTFC |
CitedBy_id | crossref_primary_10_1080_00032710600773424 crossref_primary_10_1016_j_chroma_2007_10_002 crossref_primary_10_1007_s00216_012_6590_6 crossref_primary_10_1007_s10337_014_2766_x |
Cites_doi | 10.1016/S0021-9673(00)82067-1 10.1016/S0021-9673(98)00749-3 10.1016/S0021-9673(00)96192-2 10.1007/BF02490318 10.1016/S0021-9673(01)94628-X 10.1021/ac9606113 10.1093/chromsci/27.12.721 10.1093/chromsci/39.1.29 10.1007/BF02268461 10.1016/S0021-9673(00)91669-8 10.1021/ac9612032 10.1016/S0021-9673(01)95925-4 10.1016/S0021-9673(99)00742-6 10.1002/(SICI)1521-4168(19980501)21:5<267::AID-JHRC267>3.0.CO;2-7 10.1016/S0021-9673(01)94708-9 10.1093/chromsci/21.12.560 10.1007/BF02263001 10.1016/0021-9673(94)00808-6 10.1016/S0021-9673(01)95023-X |
ContentType | Journal Article |
Copyright | Copyright Taylor & Francis Group, LLC 2003 2003 INIST-CNRS |
Copyright_xml | – notice: Copyright Taylor & Francis Group, LLC 2003 – notice: 2003 INIST-CNRS |
DBID | IQODW AAYXX CITATION |
DOI | 10.1081/JLC-120018418 |
DatabaseName | Pascal-Francis CrossRef |
DatabaseTitle | CrossRef |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Chemistry |
EISSN | 1520-572X |
EndPage | 750 |
ExternalDocumentID | 10_1081_JLC_120018418 14652645 10347456 |
Genre | Original Articles |
GroupedDBID | --- -~X .7F .QJ 0BK 0R~ 29K 30N 4.4 53G 5GY 5VS A8Z AAAJW AAAVI AAENE AAJMT AALDU AAMIU AAPUL AAQRR ABBKH ABCCY ABDBF ABFIM ABHAV ABJVF ABKVM ABLIJ ABPEM ABPTK ABQHQ ABTAI ABXUL ACGEJ ACGFS ACIWK ACPRK ACTIO ACYAP ADCVX ADGTB ADXPE AEGYZ AEISY AENEX AEOZL AEPSL AEYOC AFKVX AFOLD AFRAH AFUVZ AFWJF AFWLO AGDLA AGMYJ AHDLD AIJEM AIRXU AJWEG AKBVH AKOOK ALMA_UNASSIGNED_HOLDINGS ALQZU AQRUH AVBZW AWYRJ BDVFT BKMSO BLEHA CAG CCCUG CE4 COF CS3 CXCUG D-I DGEBU DKSSO DU5 EAP EAS EBD EBS EJD EMK EPL EST ESX E~A E~B F5P FUNRP FVPDL GTTXZ H13 HZ~ H~P I-F J.P KYCEM L7B M4Z NA5 NW0 O9- OEUFU P2P RNANH ROSJB RTWRZ S-T SNACF TCY TFL TFT TFW TTHFI TUS TWF UT5 UU3 V1K ZGOLN ~KM ~S~ .GJ 07J 1TA 3O- ABCQX ABEFU ABXYU ACMLV ADBHG ADOGB AGGGY AI. AOWVY AWFQP C5E CTOBV C~V ESTFP HF~ HJQDS IPNFZ IQODW LJTGL LZ8 NUSFT OCADI RIG RNS TAV TCCYZ TFMCV UA2 VH1 ZXP AAYXX ABJNI ABPAQ ABZMO AEUXM AHDZW CITATION TBQAZ TDBHL TUROJ |
ID | FETCH-LOGICAL-c314t-85fe1c2261f15de06447b3d8b46ba120d4ad2c4b5103cf1a751fee5b47d1bca13 |
ISSN | 1082-6076 |
IngestDate | Thu Sep 12 20:17:26 EDT 2024 Sun Oct 22 16:06:23 EDT 2023 Tue Jun 13 19:27:47 EDT 2023 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 5 |
Keywords | Performance evaluation Nitro compound Peak resolution Line shape Haloalcohol Multicomponent mixture HPLC chromatography Retention factor Number of theoretical plates Selectivity Bronopol Long term Reversed phase chromatography Ultraviolet detector Plate efficiency Bromine Organic compounds Commercial form Chemometrics Bonded stationary phase |
Language | English |
License | CC BY 4.0 |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c314t-85fe1c2261f15de06447b3d8b46ba120d4ad2c4b5103cf1a751fee5b47d1bca13 |
PageCount | 14 |
ParticipantIDs | informaworld_taylorfrancis_310_1081_JLC_120018418 pascalfrancis_primary_14652645 crossref_primary_10_1081_JLC_120018418 |
PublicationCentury | 2000 |
PublicationDate | 4/1/2003 |
PublicationDateYYYYMMDD | 2003-04-01 |
PublicationDate_xml | – month: 04 year: 2003 text: 4/1/2003 day: 01 |
PublicationDecade | 2000 |
PublicationPlace | Colchester |
PublicationPlace_xml | – name: Colchester |
PublicationTitle | Journal of liquid chromatography & related technologies |
PublicationYear | 2003 |
Publisher | Taylor & Francis Group Taylor & Francis |
Publisher_xml | – name: Taylor & Francis Group – name: Taylor & Francis |
References | CIT84180020 Engelhardt H. (CIT84180010) 1997; 12 Wieland G. (CIT84180011) 1998; 2 CIT84180009 CIT84180008 CIT84180007 CIT84180006 CIT84180005 Buszewski B. (CIT84180022) 1997 CIT84180027 CIT84180004 CIT84180026 CIT84180003 Buszewski B. (CIT84180025) 1986; 40 CIT84180024 CIT84180023 CIT84180021 Neue U. D. (CIT84180001) 1997 Vansant E. F. (CIT84180002) 1995 CIT84180019 CIT84180018 CIT84180017 CIT84180016 CIT84180015 CIT84180014 CIT84180013 CIT84180012 |
References_xml | – ident: CIT84180013 doi: 10.1016/S0021-9673(00)82067-1 – ident: CIT84180016 doi: 10.1016/S0021-9673(98)00749-3 – ident: CIT84180004 doi: 10.1016/S0021-9673(00)96192-2 – volume-title: HPLC Columns. Theory, Technology and Practice year: 1997 ident: CIT84180001 contributor: fullname: Neue U. D. – volume: 2 start-page: 74 year: 1998 ident: CIT84180011 publication-title: LC/GC Int. contributor: fullname: Wieland G. – ident: CIT84180019 doi: 10.1007/BF02490318 – ident: CIT84180008 doi: 10.1016/S0021-9673(01)94628-X – ident: CIT84180006 doi: 10.1021/ac9606113 – ident: CIT84180014 doi: 10.1093/chromsci/27.12.721 – volume: 40 start-page: 369 year: 1986 ident: CIT84180025 publication-title: Wiadomości chemiczne contributor: fullname: Buszewski B. – ident: CIT84180024 doi: 10.1093/chromsci/39.1.29 – ident: CIT84180027 – ident: CIT84180012 doi: 10.1007/BF02268461 – ident: CIT84180015 doi: 10.1016/S0021-9673(00)91669-8 – ident: CIT84180018 doi: 10.1021/ac9612032 – ident: CIT84180020 doi: 10.1007/BF02490318 – volume: 12 start-page: 803 year: 1997 ident: CIT84180010 publication-title: LC/GC Int. contributor: fullname: Engelhardt H. – ident: CIT84180021 doi: 10.1016/S0021-9673(01)95925-4 – ident: CIT84180017 doi: 10.1016/S0021-9673(99)00742-6 – ident: CIT84180023 doi: 10.1002/(SICI)1521-4168(19980501)21:5<267::AID-JHRC267>3.0.CO;2-7 – year: 1997 ident: CIT84180022 contributor: fullname: Buszewski B. – volume-title: Characterization And Chemical Modification of the Silica Surface year: 1995 ident: CIT84180002 contributor: fullname: Vansant E. F. – ident: CIT84180007 doi: 10.1016/S0021-9673(01)94708-9 – ident: CIT84180009 doi: 10.1093/chromsci/21.12.560 – ident: CIT84180026 doi: 10.1007/BF02263001 – ident: CIT84180005 doi: 10.1016/0021-9673(94)00808-6 – ident: CIT84180003 doi: 10.1016/S0021-9673(01)95023-X |
SSID | ssj0017525 |
Score | 1.6910032 |
Snippet | Different tests, including analytes or mixtures characterized by specific properties, can be used for the evaluation of chromatographic columns. High... |
SourceID | crossref pascalfrancis informaworld |
SourceType | Aggregation Database Index Database Publisher |
StartPage | 737 |
SubjectTerms | Analytical chemistry Chemistry Chemometry Chromatographic methods and physical methods associated with chromatography Column evaluation Exact sciences and technology New test mixtures Other chromatographic methods RP-HPLC Surface homogeneity |
Title | Bronopol as an Ingredient of a New Test Mixture for Evaluation of HPLC Columns |
URI | https://www.tandfonline.com/doi/abs/10.1081/JLC-120018418 |
Volume | 26 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1bb9MwFLZK9wAvE1cxLpMfEC9VRt3Ycfq4lUGh64RQJyZeIt8ClUbStYmA_jn-GseJ6yZsSIOXqE3iWPH5cvz5-FwQepFSIwZyCIucPtEBNbEJYtXvwxc_FDIS0gyrqPfpaTQ-o-_P2Xmn86vhtVQW8kCtr40r-R-pwjmQq42S_QfJ-ofCCfgN8oUjSBiON5IxrKEzW-TAFosR1roHi2frweWiHq3v4gy0fm86_1FtFFiXwmOf3ruy4X84GVnjQfnNWe2u8tSL-WU51z31dZkDu3UZrivEVHEwQFiLjXm-4ZB4VK7WoD_rothH-ZcSoOfN5SNj0yTA1Yq5vvueZ35ymCzLhVr_zNy1iSjEEv7662-FXosL4X00JvlCzcu6ntVHk8HtvelBy5QRNjxgau0LfCSI-tzlxnYaGda3jFc1173KroPsHTRZQ__yOoOMm8p5ndP2yiwBNMgWwD4ZBcS6lMXUTQGtbNx_zJLed7HatY9JAs0T3_wW2hnwIWNdtHM4fv35k9_I4qyq--vfzKV5hQe8avXfokWtpLnWW1es4INN60orDfozu4t2HR7wYQ3Ce6hjsvvo9mhTLvABOt2AEYsVFhneghHnKRYYwIgtGLEDI4a-8RaM9iYLRuzA-BCdvTmejcaBK9YRqJDQIohZaogCMk9SwrQBpku5DHUsaSQFvKamQg8UlTaDo0qJ4IykxjBJuSZSCRI-Qt0sz8xjhKEFF0YPVaqhNR2IUPBBn0EH2oSRJnvo5WaskkWdkyW5Vip7iDRHMikqI5gbxyT8S5v91nBve6ARg9UDe3LT3p-iO1uQP0PdYlma58BgC7nvUPIbWr6bXQ |
link.rule.ids | 315,786,790,27955,27956,60239,61028 |
linkProvider | Library Specific Holdings |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV07T8MwELagDGXhjSiP4gGxpcSJnceIolZtSSuGVqrEENmxLSGkFJFUQvx6zklaWhBLd59f58ed7_N3CN1pqrgjQnBybCItqgJlBaltw44PufC4UGH563009vpTOpyxWY2qzGtYpfGhdUUUUZ7VZnObx-gaEkcehnFkEQMGCigJdtGeZ35omu8b9ngVQfBZmXAVyjuWB856za_5R3zjPtpgKzUwSZ7DTOkqxcXavdM7RC_LHldwk7fOohCd9OsXmeN2QzpCB7U5ih-r9XOMdlR2gprRMgvcKRqDn56ZRAqY55hneJCBg25QYgWea8wxHJJ4AjcLHr1-mmAEhpHh7opC3BTqP8cRjswpmOVnaNrrTqK-VedgsFKX0MIKmFYkBRuNaMKkAgOG-sKVgaCe4NBhSbl0UioMMV-qCfcZ0UoxQX1JRMqJe44a2TxTFwiDhM-VDFMtQZo63OW-YzNoQCrXk6SF7peaSN4rqo2kDJEHJIHpSVbT00JkXU9JUb5t1FpK3H9k2hvK_GmBegyMQna5RaW3qNmfjOIkHoyfrtB-ifMrQT3XqFF8LNQN2CuFaJcL8xsVN-Ni |
linkToPdf | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV07T8MwELagSMDCG1EexQNiS4kTO48RBaq2tFGHVqpYIju2JYSUVjSVEL-ec5KWFsTS3Rc_zvbd5T5_h9Cdpoo7IoQgxybSoipQVpDaNpz4kAuPCxUWr977sdce0e6YjVdKfRlYpYmhdUkUUdzV5nBPpa4QceSh24ssYrBAASXBNtrxjJE0rzfseJlA8FlRbxXaO5YHsXpFr_lHfM0crZGVGpQkn8FC6bLCxYrZaR2i18WAS7TJe3Oei2b69YvLcaMZHaGDyhnFj-XuOUZbKjtBe9GiBtwpiiFKz0wZBcxnmGe4k0F4bjBiOZ5ozDFckXgIdgX33z5NKgLDxPDzkkDcNGoPehGOzB2Yzc7QqPU8jNpWVYHBSl1CcytgWpEUPDSiCZMK3BfqC1cGgnqCw4Al5dJJqTC0fKkm3GdEK8UE9SURKSfuOaplk0xdIAwSPlcyTLUEaepwl_uOzaADqVxPkjq6XygimZZEG0mRIA9IAsuTLJenjsiqmpK8-LNRKSlx_5FprOnypwfqMXAJ2eUGH71Fu4OnVtLrxC9XaL8A-RWInmtUyz_m6gaclVw0im35DX_H4g8 |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Bronopol+as+an+Ingredient+of+a+New+Test+Mixture+for+Evaluation+of+HPLC+Columns&rft.jtitle=Journal+of+liquid+chromatography+%26+related+technologies&rft.au=Buszewski%2C+Boguslaw&rft.au=Cendrowska%2C+Iwona&rft.au=Krupczynska%2C+Katarzyna&rft.au=Gadzala%E2%80%90Kopciuch%2C+Renata+M.&rft.date=2003-04-01&rft.issn=1082-6076&rft.eissn=1520-572X&rft.volume=26&rft.issue=5&rft.spage=737&rft.epage=750&rft_id=info:doi/10.1081%2FJLC-120018418&rft.externalDBID=n%2Fa&rft.externalDocID=10_1081_JLC_120018418 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1082-6076&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1082-6076&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1082-6076&client=summon |