Evaluation of the FreeStyle® Libre Flash Glucose Monitoring System in Children and Adolescents with Type 1 Diabetes
The FreeStyle® Libre Flash Glucose Monitoring System (FGM, Abbott) measures glucose concentrations in the interstitial fluid for up to 14 days. It has been approved for use in children aged > 4 years in January 2016. Experience in children is still limited. We evaluated the accuracy and usability...
Saved in:
Published in | Hormone research in paediatrics Vol. 89; no. 3; p. 189 |
---|---|
Main Authors | , , , , , , |
Format | Journal Article |
Language | English |
Published |
Switzerland
01.01.2018
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Abstract | The FreeStyle® Libre Flash Glucose Monitoring System (FGM, Abbott) measures glucose concentrations in the interstitial fluid for up to 14 days. It has been approved for use in children aged > 4 years in January 2016. Experience in children is still limited. We evaluated the accuracy and usability of the FGM in children with type 1 diabetes mellitus (DM).
67 children with type 1 DM (35 girls), aged 4-18 years, were included. Subjects wore a sensor on the back of their upper arm. For the first 14 days, they regularly measured capillary blood glucose (BG) with their usual BG meter (Accu-Chek® Mobile [ACM], Roche [n = 24]; Contour® Next Link [CNL], Bayer [n = 26]; OneTouch® Verio® IQ [OTV], LifeScan [n = 17]) followed by a sensor glucose (SG) scanning. SG readings were compared to BG measurements by consensus error grid (CEG) analysis; the mean difference (MD), the mean relative difference (MRD), the mean absolute difference (MAD), and the mean absolute relative difference (MARD) were calculated. After 14 days, subjects were asked to fill in a questionnaire on the usability of the FGM.
2,626 SG readings were paired with BG results. FGM readings were highly correlated with BG (r = 0.926, p < 0.001). 80.3% of the data pairs were in zone A (= no effect on clinical action) and 18.4% were in zone B (= altered clinical action with little or no effect on the clinical outcome) of the CEG. Overall MD was +7.5 mg/dL; MD varied with the BG meter: ACM +10.4 mg/dL, CNL +14.2 mg/dL, OTV -3.6 mg/dL (p < 0.001). Overall, MARD was 16.7%. We observed a large interindividual variability in the accuracy parameters. MD and MRD were inversely related to BMI (r = -0.261 [p < 0.05]; r = -0.266 [p < 0.05], respectively). MARD was inversely related to age (r = -0.266 [p < 0.05]). Twenty-nine patients (43.3%) reported sensor problems, mainly early detachment of the sensor. Nonetheless, the usability questionnaire indicated high levels of satisfaction.
Our results showed a reasonable agreement between the FGM SG readings and capillary BG measurements in children. There was, however, a large interindividual variability. The wearing of the sensor requires special attention. Further studies in children are imperative in order to document the accuracy and safety of the FGM in the paediatric population. |
---|---|
AbstractList | The FreeStyle® Libre Flash Glucose Monitoring System (FGM, Abbott) measures glucose concentrations in the interstitial fluid for up to 14 days. It has been approved for use in children aged > 4 years in January 2016. Experience in children is still limited. We evaluated the accuracy and usability of the FGM in children with type 1 diabetes mellitus (DM).
67 children with type 1 DM (35 girls), aged 4-18 years, were included. Subjects wore a sensor on the back of their upper arm. For the first 14 days, they regularly measured capillary blood glucose (BG) with their usual BG meter (Accu-Chek® Mobile [ACM], Roche [n = 24]; Contour® Next Link [CNL], Bayer [n = 26]; OneTouch® Verio® IQ [OTV], LifeScan [n = 17]) followed by a sensor glucose (SG) scanning. SG readings were compared to BG measurements by consensus error grid (CEG) analysis; the mean difference (MD), the mean relative difference (MRD), the mean absolute difference (MAD), and the mean absolute relative difference (MARD) were calculated. After 14 days, subjects were asked to fill in a questionnaire on the usability of the FGM.
2,626 SG readings were paired with BG results. FGM readings were highly correlated with BG (r = 0.926, p < 0.001). 80.3% of the data pairs were in zone A (= no effect on clinical action) and 18.4% were in zone B (= altered clinical action with little or no effect on the clinical outcome) of the CEG. Overall MD was +7.5 mg/dL; MD varied with the BG meter: ACM +10.4 mg/dL, CNL +14.2 mg/dL, OTV -3.6 mg/dL (p < 0.001). Overall, MARD was 16.7%. We observed a large interindividual variability in the accuracy parameters. MD and MRD were inversely related to BMI (r = -0.261 [p < 0.05]; r = -0.266 [p < 0.05], respectively). MARD was inversely related to age (r = -0.266 [p < 0.05]). Twenty-nine patients (43.3%) reported sensor problems, mainly early detachment of the sensor. Nonetheless, the usability questionnaire indicated high levels of satisfaction.
Our results showed a reasonable agreement between the FGM SG readings and capillary BG measurements in children. There was, however, a large interindividual variability. The wearing of the sensor requires special attention. Further studies in children are imperative in order to document the accuracy and safety of the FGM in the paediatric population. |
Author | Op 't Eyndt, Anniek Massa, Guy G Bevilacqua, Esmiralda Declercq, Peter Zeevaert, Renate Gys, Inge Wijnands, Anne |
Author_xml | – sequence: 1 givenname: Guy G surname: Massa fullname: Massa, Guy G organization: Department of Paediatric Endocrinology and Diabetology, Jessa Hospital, Hasselt, Belgium – sequence: 2 givenname: Inge surname: Gys fullname: Gys, Inge organization: Department of Paediatric Endocrinology and Diabetology, Jessa Hospital, Hasselt, Belgium – sequence: 3 givenname: Anniek surname: Op 't Eyndt fullname: Op 't Eyndt, Anniek organization: Department of Paediatric Endocrinology and Diabetology, Jessa Hospital, Hasselt, Belgium – sequence: 4 givenname: Esmiralda surname: Bevilacqua fullname: Bevilacqua, Esmiralda organization: Department of Paediatric Endocrinology and Diabetology, Jessa Hospital, Hasselt, Belgium – sequence: 5 givenname: Anne surname: Wijnands fullname: Wijnands, Anne organization: Department of Paediatric Endocrinology and Diabetology, Jessa Hospital, Hasselt, Belgium – sequence: 6 givenname: Peter surname: Declercq fullname: Declercq, Peter organization: Clinical Laboratory, Jessa Hospital, Hasselt, Belgium – sequence: 7 givenname: Renate surname: Zeevaert fullname: Zeevaert, Renate organization: Department of Paediatric Endocrinology and Diabetology, Jessa Hospital, Hasselt, Belgium |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/29587254$$D View this record in MEDLINE/PubMed |
BookMark | eNo1j9FKwzAYhYMobs5d-ALyv0A1Sdu0vRxzm0LFi83rkaR_bSRLRpMpfSkfwiezoF4dOOfjwHdFzp13SMgNo3eM5dU9pTQri1SwMzJlQqQJL7mYkHkI7-NE07KoWHFJJrzKy4Ln2ZTE1Ye0JxmNd-BbiB3CukfcxsHi9xfURvVjY2XoYGNP2geEZ-9M9L1xb7AdQsQDGAfLztimRwfSNbBovMWg0cUAnyZ2sBuOCAwejFQYMVyTi1bagPO_nJHX9Wq3fEzql83TclEnOqUiJthq3jJWUt22lVCqLJliFFVFMZNajoKYNprnKquyQox6jShYmukW5Ygwxmfk9vf3eFIHbPbH3hxkP-z_9fkPC3VdWQ |
CitedBy_id | crossref_primary_10_1111_pedi_12833 crossref_primary_10_1111_pedi_12910 crossref_primary_10_1007_s15034_018_1303_7 crossref_primary_10_1507_endocrj_EJ19_0488 crossref_primary_10_20945_2359_3997000000540 crossref_primary_10_1089_dia_2023_0349 crossref_primary_10_1016_j_dsx_2022_102620 crossref_primary_10_1016_j_pedn_2024_04_054 crossref_primary_10_2337_dc19_S007 crossref_primary_10_1016_j_pcd_2018_08_004 crossref_primary_10_1111_jdi_13229 crossref_primary_10_3390_nano12030334 crossref_primary_10_1136_bmjopen_2021_053642 crossref_primary_10_1177_19322968231190941 crossref_primary_10_1111_pedi_13160 crossref_primary_10_3390_pr10122706 crossref_primary_10_1016_j_pcd_2018_12_010 crossref_primary_10_3390_s20010128 crossref_primary_10_2217_pme_2018_0044 crossref_primary_10_2147_CEOR_S346736 crossref_primary_10_4239_wjd_v12_i11_1908 crossref_primary_10_1111_pedi_13135 crossref_primary_10_46632_jitl_3_1_3 crossref_primary_10_1177_1098612X20965012 crossref_primary_10_3390_nu10080992 crossref_primary_10_1016_j_arcped_2024_09_005 crossref_primary_10_1021_acsabm_0c00798 crossref_primary_10_1016_j_bios_2023_115571 crossref_primary_10_1016_j_diabres_2018_10_001 crossref_primary_10_1007_s00592_018_1218_8 crossref_primary_10_1111_cod_13120 crossref_primary_10_1177_1098612X221104051 crossref_primary_10_3390_s23073429 crossref_primary_10_1016_j_enfcle_2019_07_011 crossref_primary_10_1055_a_1975_4136 crossref_primary_10_2196_diabetes_9926 crossref_primary_10_1007_s10877_019_00384_y crossref_primary_10_1002_pdi_2374 crossref_primary_10_1016_j_diabres_2019_05_015 crossref_primary_10_1016_j_enfcli_2019_07_011 crossref_primary_10_1055_a_0875_3988 crossref_primary_10_1111_pedi_12729 crossref_primary_10_1155_2020_5947680 crossref_primary_10_3390_diagnostics13050916 crossref_primary_10_1007_s13300_022_01224_0 crossref_primary_10_1111_dom_15719 crossref_primary_10_1007_s13300_019_0616_4 crossref_primary_10_3389_fphys_2021_732751 crossref_primary_10_1002_star_202200279 crossref_primary_10_1186_s12902_019_0378_z crossref_primary_10_1249_MSS_0000000000003404 |
ContentType | Journal Article |
Copyright | 2018 S. Karger AG, Basel. |
Copyright_xml | – notice: 2018 S. Karger AG, Basel. |
DBID | NPM |
DOI | 10.1159/000487361 |
DatabaseName | PubMed |
DatabaseTitle | PubMed |
DatabaseTitleList | PubMed |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
Discipline | Anatomy & Physiology |
EISSN | 1663-2826 |
ExternalDocumentID | 29587254 |
Genre | Journal Article |
GroupedDBID | --- 0R~ 0~5 0~B 30W 327 3O. 4.4 53G 7RV 7X7 88E 8AO 8FI 8FJ AAYIC ABBTS ABJNI ABPAZ ABUWG ABWCG ACGFS ACPRK ACPSR ADBBV AENEX AEYAO AFJJK AFKRA AFRAH AHFRZ AHMBA ALDHI ALIPV ALMA_UNASSIGNED_HOLDINGS AZPMC AZQEC BENPR BKEYQ BKNYI BPHCQ BVXVI CAG CCPQU COF CYUIP DU5 E0A EBS EJD EMOBN EX3 F5P FB. FYUFA HMCUK HZ~ IY7 K9- KUZGX M0R M1P NAPCQ NPM O1H O9- OVD PHGZM PHGZT PJZUB PPXIY PQQKQ PROAC PSQYO RKO RXVBD SV3 TEORI UJ6 UKHRP WOW |
ID | FETCH-LOGICAL-c306t-efc2f1180cff96bb881b10eb90e4aca166e3dc25b49476003d67134cfea90e112 |
IngestDate | Mon Jul 21 06:08:25 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 3 |
Keywords | Accuracy Flash glucose monitoring Child Usability Diabetes mellitus |
Language | English |
License | 2018 S. Karger AG, Basel. |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c306t-efc2f1180cff96bb881b10eb90e4aca166e3dc25b49476003d67134cfea90e112 |
PMID | 29587254 |
ParticipantIDs | pubmed_primary_29587254 |
PublicationCentury | 2000 |
PublicationDate | 2018-01-01 |
PublicationDateYYYYMMDD | 2018-01-01 |
PublicationDate_xml | – month: 01 year: 2018 text: 2018-01-01 day: 01 |
PublicationDecade | 2010 |
PublicationPlace | Switzerland |
PublicationPlace_xml | – name: Switzerland |
PublicationTitle | Hormone research in paediatrics |
PublicationTitleAlternate | Horm Res Paediatr |
PublicationYear | 2018 |
SSID | ssj0000387917 |
Score | 2.4134438 |
Snippet | The FreeStyle® Libre Flash Glucose Monitoring System (FGM, Abbott) measures glucose concentrations in the interstitial fluid for up to 14 days. It has been... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 189 |
Title | Evaluation of the FreeStyle® Libre Flash Glucose Monitoring System in Children and Adolescents with Type 1 Diabetes |
URI | https://www.ncbi.nlm.nih.gov/pubmed/29587254 |
Volume | 89 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9QwELa25cIFUcqbojlQLlFg846PqyrdFVLhQCv1VtmODSt1swvNIoXfw5kfwS_r-JHEKg8BlyiykyjKfBnPjGe-IeSFYjUuBFkUJnmpwhQX2JDSWoRToetA6ymvTY-lk7f54ix9c56dTybfvKylbctfia-_rCv5H6niGMpVV8n-g2SHh-IAnqN88YgSxuNfybgaqLr7rf7jz1K-b7tLeXgUH86qQJcl4CiayB-DuctOt7-xybuzfOWm8q8v6taB9NlI82QDtdpbDaLApc9c-RbtAo3edaObr4wBlA3rG4AMFvsJGunGTp1vu7Gf17xzSurDgK93G0Rj0QZV19SWEqFpltKrJ_qyvGTi09Y8rLpaLXVMjfnBi6j0ghfSKly0eEJ0-3JfI9umQg55iadeIzvzs9rPqM2TRPcrseTunvg3KyP_mGZlEVvK6j_P3mDg7qd2yA76Irq5qosImdU-KQt0eR1pFb7I6-E1NNG0u_WG02KMl9O75I7zOmBmIbRHJrK5R_ZnDWvXqw5egskDNhss-6QdUQVrBYgqGFD14zsYRIFBFDhEwYgosIiCZQM9ogARBR6iQCMKNKIggh5R98nZcXV6tAhdb45QoJPZhlKJWGn6QKEUzTkv0f2JppLTqUyZYChWmdQiznhKU733m9S5rloWSjK8BI38B2S3QXQ-IsBVXLCC40KXypQyVA8lRbdecKmilHP1mDy03-5iYwlYLvqv-uS3M0_J7RFuz8gthX-8PEDzseXPjfyuAW8ick0 |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Evaluation+of+the+FreeStyle%C2%AE+Libre+Flash+Glucose+Monitoring+System+in+Children+and+Adolescents+with+Type+1+Diabetes&rft.jtitle=Hormone+research+in+paediatrics&rft.au=Massa%2C+Guy+G&rft.au=Gys%2C+Inge&rft.au=Op+%27t+Eyndt%2C+Anniek&rft.au=Bevilacqua%2C+Esmiralda&rft.date=2018-01-01&rft.eissn=1663-2826&rft.volume=89&rft.issue=3&rft.spage=189&rft_id=info:doi/10.1159%2F000487361&rft_id=info%3Apmid%2F29587254&rft_id=info%3Apmid%2F29587254&rft.externalDocID=29587254 |