Evaluation of Automated Finger Compression for Capillary Refill Time Measurement in Pediatrics

Early shock reversal is crucial to improve patient outcomes. Capillary refill time (CRT) is clinically important to identify and monitor shock in children but has issues with inconsistency. To minimize inconsistency, we evaluated a CRT monitoring system using an automated compression device. Our obj...

Full description

Saved in:
Bibliographic Details
Published inPediatric emergency care Vol. 40; no. 8; p. 586
Main Authors Nickel, Amanda J, Jiang, Shen, Napolitano, Natalie, Donoghue, Aaron, Nadkarni, Vinay M, Nishisaki, Akira
Format Journal Article
LanguageEnglish
Published United States 01.08.2024
Subjects
Online AccessGet more information

Cover

Loading…
Abstract Early shock reversal is crucial to improve patient outcomes. Capillary refill time (CRT) is clinically important to identify and monitor shock in children but has issues with inconsistency. To minimize inconsistency, we evaluated a CRT monitoring system using an automated compression device. Our objective was to determine proper compression pressure in children. Clinician force for CRT was collected during manual CRT measurement as a reference for automated compression in a previous study (12.9 N, 95% confidence interval, 12.5-13.4; n = 454). An automated compression device with a soft inflation bladder was fitted with a force sensor. We evaluated the effectiveness of the automated pressure to eliminate pulsatile blood flow from the distal phalange. Median and variance of CRT analysis at each pressure was compared. A comparison of pressures at 300 to 500 mm Hg on a simulated finger yielded a force of 5 to 10 N, and these pressures were subsequently used for automated compression for CRT. Automated compression was tested in 44 subjects (median age, 33 months; interquartile range [IQR], 14-56 months). At interim analysis of 17 subjects, there was significant difference in the waveform with residual pulsatile blood flow (9/50: 18% at 300 mm Hg, 5/50:10% at 400 mm Hg, 0/51: 0% at 500 mm Hg, P = 0.008). With subsequent enrollment of 27 subjects at 400 and 500 mm Hg, none had residual pulsatile blood flow. There was no difference in the CRT: median 1.8 (IQR, 1.06-2.875) in 400 mm Hg vs median 1.87 (IQR, 1.25-2.8325) in 500 mm Hg, P = 0.81. The variance of CRT was significantly larger in 400 mm Hg: 2.99 in 400 mm Hg vs. 1.35 in 500 mm Hg, P = 0.02, Levene's test. Intraclass correlation coefficient for automated CRT was 0.56 at 400 mm Hg and 0.78 at 500 mm Hg. Using clinician CRT measurement data, we determined either 400 or 500 mm Hg is an appropriate pressure for automated CRT, although 500 mm Hg demonstrates superior consistency.
AbstractList Early shock reversal is crucial to improve patient outcomes. Capillary refill time (CRT) is clinically important to identify and monitor shock in children but has issues with inconsistency. To minimize inconsistency, we evaluated a CRT monitoring system using an automated compression device. Our objective was to determine proper compression pressure in children. Clinician force for CRT was collected during manual CRT measurement as a reference for automated compression in a previous study (12.9 N, 95% confidence interval, 12.5-13.4; n = 454). An automated compression device with a soft inflation bladder was fitted with a force sensor. We evaluated the effectiveness of the automated pressure to eliminate pulsatile blood flow from the distal phalange. Median and variance of CRT analysis at each pressure was compared. A comparison of pressures at 300 to 500 mm Hg on a simulated finger yielded a force of 5 to 10 N, and these pressures were subsequently used for automated compression for CRT. Automated compression was tested in 44 subjects (median age, 33 months; interquartile range [IQR], 14-56 months). At interim analysis of 17 subjects, there was significant difference in the waveform with residual pulsatile blood flow (9/50: 18% at 300 mm Hg, 5/50:10% at 400 mm Hg, 0/51: 0% at 500 mm Hg, P = 0.008). With subsequent enrollment of 27 subjects at 400 and 500 mm Hg, none had residual pulsatile blood flow. There was no difference in the CRT: median 1.8 (IQR, 1.06-2.875) in 400 mm Hg vs median 1.87 (IQR, 1.25-2.8325) in 500 mm Hg, P = 0.81. The variance of CRT was significantly larger in 400 mm Hg: 2.99 in 400 mm Hg vs. 1.35 in 500 mm Hg, P = 0.02, Levene's test. Intraclass correlation coefficient for automated CRT was 0.56 at 400 mm Hg and 0.78 at 500 mm Hg. Using clinician CRT measurement data, we determined either 400 or 500 mm Hg is an appropriate pressure for automated CRT, although 500 mm Hg demonstrates superior consistency.
Author Nickel, Amanda J
Nadkarni, Vinay M
Donoghue, Aaron
Jiang, Shen
Napolitano, Natalie
Nishisaki, Akira
Author_xml – sequence: 1
  givenname: Amanda J
  surname: Nickel
  fullname: Nickel, Amanda J
  organization: From the Department of Respiratory Care, Children's Hospital of Philadelphia, Philadelphia, PA
– sequence: 2
  givenname: Shen
  surname: Jiang
  fullname: Jiang, Shen
  organization: Nihon Kohden Innovation Center, Boston, MA
– sequence: 3
  givenname: Natalie
  surname: Napolitano
  fullname: Napolitano, Natalie
  organization: From the Department of Respiratory Care, Children's Hospital of Philadelphia, Philadelphia, PA
– sequence: 4
  givenname: Aaron
  surname: Donoghue
  fullname: Donoghue, Aaron
– sequence: 5
  givenname: Vinay M
  surname: Nadkarni
  fullname: Nadkarni, Vinay M
– sequence: 6
  givenname: Akira
  surname: Nishisaki
  fullname: Nishisaki, Akira
BackLink https://www.ncbi.nlm.nih.gov/pubmed/38875463$$D View this record in MEDLINE/PubMed
BookMark eNpNT9tKxDAQDaK4F_0DkfxA10nTNOnjUnZXYcVF1leXaTuRSNOWphX8eysqeF7OZWA4Z8HOm7Yhxm4ErARk-u6wyVfwD1IYecbmQkkVCSPUjC1CeAeYAikv2Uwao1WSyjl73XxgPeLg2oa3lq_HofU4UMW3rnmjnuet73oK4ftu28lj5-oa-0_-THZS_Og88UfCMPbkqRm4a_iBKodD78pwxS4s1oGuf3nJXrabY34f7Z92D_l6H5USlIwQEpuWlZZalUpRZq3RICAV0gAqg6kqQJOARMnYpKYAITC2iSgTtLbMqnjJbn_-dmPhqTp1vfNTydPf0PgL08tV-w
ContentType Journal Article
Copyright Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.
Copyright_xml – notice: Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.
DBID CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.1097/PEC.0000000000003183
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
EISSN 1535-1815
ExternalDocumentID 38875463
Genre Journal Article
GroupedDBID ---
.-D
.XZ
.Z2
0R~
123
4Q1
4Q2
4Q3
53G
5RE
5VS
71W
8L-
AAAAV
AAHPQ
AAIQE
AAJCS
AARTV
AASCR
AAUEB
AAWTL
AAYEP
ABASU
ABBUW
ABDIG
ABJNI
ABPPZ
ABPXF
ABVCZ
ABXVJ
ABXYN
ABZAD
ABZZY
ACDDN
ACDOF
ACEWG
ACGFO
ACGFS
ACILI
ACWDW
ACWRI
ACXJB
ACXNZ
ADGGA
ADHPY
AE6
AEBDS
AENEX
AFBFQ
AFDTB
AFEXH
AFMBP
AFNMH
AFSOK
AHQNM
AHQVU
AHVBC
AINUH
AJCLO
AJIOK
AJNWD
AJZMW
AKCTQ
ALKUP
ALMA_UNASSIGNED_HOLDINGS
ALMTX
AMJPA
AMKUR
AMNEI
AOHHW
AOQMC
BQLVK
BYPQX
C45
CGR
CS3
CUY
CVF
DIWNM
DU5
E.X
EBS
ECM
EEVPB
EIF
EX3
F5P
FCALG
FL-
GNXGY
GQDEL
H0~
HLJTE
HZ~
IKREB
IN~
JK3
JK8
K-A
K-F
KD2
L-C
N9A
NPM
O9-
OAG
OAH
ODMTH
OHYEH
OLG
OPUJH
OVD
OVDNE
OVOZU
OWV
OWW
OWY
OWZ
OXXIT
P2P
RLZ
S4R
S4S
TEORI
TSPGW
V2I
VVN
W3M
WOQ
WOW
X3V
X3W
XYM
YFH
ZFV
ID FETCH-LOGICAL-c3053-a04f6cd7375c55e9ff8701061380a58a65b07e104532868b011a2f41c4affc9d2
IngestDate Tue May 06 01:31:48 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 8
Language English
License Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c3053-a04f6cd7375c55e9ff8701061380a58a65b07e104532868b011a2f41c4affc9d2
PMID 38875463
ParticipantIDs pubmed_primary_38875463
PublicationCentury 2000
PublicationDate 2024-Aug-01
PublicationDateYYYYMMDD 2024-08-01
PublicationDate_xml – month: 08
  year: 2024
  text: 2024-Aug-01
  day: 01
PublicationDecade 2020
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Pediatric emergency care
PublicationTitleAlternate Pediatr Emerg Care
PublicationYear 2024
SSID ssj0015333
Score 2.3844104
Snippet Early shock reversal is crucial to improve patient outcomes. Capillary refill time (CRT) is clinically important to identify and monitor shock in children but...
SourceID pubmed
SourceType Index Database
StartPage 586
SubjectTerms Automation
Capillaries - physiology
Child
Child, Preschool
Female
Fingers - blood supply
Humans
Infant
Male
Monitoring, Physiologic - instrumentation
Monitoring, Physiologic - methods
Pressure
Pulsatile Flow - physiology
Shock - diagnosis
Shock - physiopathology
Shock - therapy
Title Evaluation of Automated Finger Compression for Capillary Refill Time Measurement in Pediatrics
URI https://www.ncbi.nlm.nih.gov/pubmed/38875463
Volume 40
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1La8JAEF5sC-Kl9P0ue-itpI3ZbLI5FquIUOlBwVNl81jqwUSsXvob-qM74yabYC195BBkV5aQ-Xbyzew8CLlR3Aei7CkrAPRYLg-4JeKIWT7zwsgRdgwXRlv0ve7Q7Y34qFb7qEQtLRfhXfS-Ma_kP1KFMZArZsn-QbJmURiA3yBfuIOE4f4rGbdNqe4VoVwuMuCfwCA7urog7nUd5qqjCVtyhj2G5ki71QSbdk6msKtLLyE6P0zvjrcqbzWjt4nJ18SgsfJYA7SBPu-fom-iPG3qTQqP9GuZddaX2BwCeGmmNTyWYTRrPWYp9hHWnlY5z3GTeyYc18TFwYel0KbcAgrBq-pWV2fKYSUqupPrmthfdLquFfzcbulak_mFuqj6d5DMbLqSMwO9iUX-f55dq7RdTG2RLbA5sIkqen7yEymgxaxIvQz8-02P0yD1Yok1I2VFVgZ7ZDe3MuiDhsw-qSXpAak_5XEUh-SlRA7NFDXIoRo5tIIcCsihBjlUI4cicmgFOXSS0hI5R2TYaQ9aXSvvtGFFoO-ZJW1XeVHsM59HnCeBUqDG0VnAhC25kB4PbT8By50zR3gihI-CdJTbjFypVBTEzjHZTrM0OSWUAcGVTUeGLhNgDAvseBbbjMVNGSoVJ2fkRL-Z8UyXUxkX7-z825kL0ijxdUl2FOzf5ArI4CK8XknpExKfXaM
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Evaluation+of+Automated+Finger+Compression+for+Capillary+Refill+Time+Measurement+in+Pediatrics&rft.jtitle=Pediatric+emergency+care&rft.au=Nickel%2C+Amanda+J&rft.au=Jiang%2C+Shen&rft.au=Napolitano%2C+Natalie&rft.au=Donoghue%2C+Aaron&rft.date=2024-08-01&rft.eissn=1535-1815&rft.volume=40&rft.issue=8&rft.spage=586&rft_id=info:doi/10.1097%2FPEC.0000000000003183&rft_id=info%3Apmid%2F38875463&rft_id=info%3Apmid%2F38875463&rft.externalDocID=38875463