An early European experience with transapical off-pump mitral valve repair with NeoChord implantation
Transapical off-pump NeoChord repair is a novel minimally invasive surgical procedure to treat degenerative mitral valve regurgitation. The aim was to evaluate 1-year clinical results of the NeoChord procedure in a consecutive cohort of patients. Between February 2013 and July 2016, 213 patients wer...
Saved in:
Published in | European journal of cardio-thoracic surgery Vol. 54; no. 3; pp. 460 - 466 |
---|---|
Main Authors | , , , , , , , , , , , , , , , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Germany
01.09.2018
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Transapical off-pump NeoChord repair is a novel minimally invasive surgical procedure to treat degenerative mitral valve regurgitation. The aim was to evaluate 1-year clinical results of the NeoChord procedure in a consecutive cohort of patients.
Between February 2013 and July 2016, 213 patients were enrolled in the NeoChord Independent International Registry. All patients presented severe mitral regurgitation due to flail/prolapse of 1 or both leaflets, and they all completed postoperative echocardiographic assessment up to 1 year. We identified the primary end point as composed of procedural success, freedom from mortality, stroke, reintervention, recurrence of severe mitral regurgitation, rehospitalization and decrease of at least 1 New York Heart Association functional class at 1-year follow-up. We also compared outcomes according to the anatomical classification (Type A: isolated central posterior leaflet disease; Type B: posterior multisegment disease; Type C: anterior, bileaflet, paracommissural disease with/without leaflet/annular calcifications).
The median age was 68 years (interquartile range 56-77), and the median EuroSCORE II was 1.05% (interquartile range 0.67-1.76). The number of Type A, B and C patients was 82 (38.5%), 98 (46%) and 33 (15.5%), respectively. Procedural success was achieved in 206 (96.7%) patients. At 1-year follow-up, overall survival was 98 ± 1%. Composite end point was achieved in 84 ± 2.5% for the overall population and 94 ± 2.6%, 82.6 ± 3.8% and 63.6 ± 8.4% in Type A, Type B and Type C patients, respectively (P < 0.0001).
These results demonstrate that the NeoChord procedure is safe, effective and reproducible. Clinical and echocardiographic efficacy is maintained up to 1 year with significant differences among the anatomical groups. Specific anatomical selection criteria are necessary to achieve stable results. |
---|---|
ISSN: | 1010-7940 1873-734X |
DOI: | 10.1093/ejcts/ezy064 |