Intercomparison of a correlated-photon-based method to measure detector quantum efficiency
We report on the absolute calibration of photodetector quantum efficiency by using correlated photon sources, performed independently at two laboratories, the National Institute of Standards and Technology and the Istituto Elettrotecnico Nazionale (IEN). The goal is to use an interlaboratory compari...
Saved in:
Published in | Applied optics (2004) Vol. 41; no. 15; p. 2914 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
United States
20.05.2002
|
Online Access | Get more information |
Cover
Loading…
Abstract | We report on the absolute calibration of photodetector quantum efficiency by using correlated photon sources, performed independently at two laboratories, the National Institute of Standards and Technology and the Istituto Elettrotecnico Nazionale (IEN). The goal is to use an interlaboratory comparison to demonstrate the inherent absoluteness of the photon correlation technique by showing its independence from the particular experimental setup. We find that detector nonuniformity limited this comparison rather than uncertainty inherent in the method itself. The ultimate goal of these investigations is development of a robust measurement protocol that allows the uncertainties of individual measurements to be determined experimentally and verified operationally. Furthermore, to demonstrate the generality of the procedure, the IEN measurement setup was also used to calibrate a fiber-coupled avalanche photodiode module. Uncertainties are evaluated for the detector both with and without fiber coupling and differences are discussed. The current IEN setup using a thinner and higher transmittance nonlinear crystal for the generation of correlated photons shows a significant improvement in overall accuracy with respect to previously reported results from IEN [Metrologia 32, 501-503 (1996)]. |
---|---|
AbstractList | We report on the absolute calibration of photodetector quantum efficiency by using correlated photon sources, performed independently at two laboratories, the National Institute of Standards and Technology and the Istituto Elettrotecnico Nazionale (IEN). The goal is to use an interlaboratory comparison to demonstrate the inherent absoluteness of the photon correlation technique by showing its independence from the particular experimental setup. We find that detector nonuniformity limited this comparison rather than uncertainty inherent in the method itself. The ultimate goal of these investigations is development of a robust measurement protocol that allows the uncertainties of individual measurements to be determined experimentally and verified operationally. Furthermore, to demonstrate the generality of the procedure, the IEN measurement setup was also used to calibrate a fiber-coupled avalanche photodiode module. Uncertainties are evaluated for the detector both with and without fiber coupling and differences are discussed. The current IEN setup using a thinner and higher transmittance nonlinear crystal for the generation of correlated photons shows a significant improvement in overall accuracy with respect to previously reported results from IEN [Metrologia 32, 501-503 (1996)]. |
Author | Migdall, Alan Degiovanni, Ivo Pietro Rastello, Maria Luisa Castelletto, Stefania |
Author_xml | – sequence: 1 givenname: Alan surname: Migdall fullname: Migdall, Alan organization: Optical Technology Division of the National Institute of Standards and Technology, Gaithersburg, Maryland 20899-8441, USA – sequence: 2 givenname: Stefania surname: Castelletto fullname: Castelletto, Stefania – sequence: 3 givenname: Ivo Pietro surname: Degiovanni fullname: Degiovanni, Ivo Pietro – sequence: 4 givenname: Maria Luisa surname: Rastello fullname: Rastello, Maria Luisa |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/12027179$$D View this record in MEDLINE/PubMed |
BookMark | eNo1j0lLAzEYQHOo2EVvniV_YGrWyeRYikuh0IuCeClZvtCRTjImmUP_vYJ6eu_04C3RLKYICN1Rsqa8FQ-bw1rQNSFMUzFDCyqlbijr3udoWconIVwKra7RnDLCFFV6gT52sUJ2aRhN7kuKOAVssEs5w9lU8M14SjXFxpoCHg9QT8njmn7MlCkD9lDB1ZTx12RinQYMIfSuh-guN-gqmHOB2z-u0NvT4-v2pdkfnnfbzb5xrFO1EbrzlHFLTMuFotJxa1tg0gfGpCXcKitosOC0Z51TAEEYHwzvtOkk5Zyt0P1vd5zsAP445n4w-XL8n2Tfc_FVDg |
CitedBy_id | crossref_primary_10_1016_j_nima_2019_05_008 crossref_primary_10_1364_OE_19_023249 crossref_primary_10_1016_j_optcom_2012_01_007 crossref_primary_10_1140_epjqt_s40507_020_00089_1 crossref_primary_10_1088_1367_2630_6_1_087 crossref_primary_10_1063_1_2338830 crossref_primary_10_1051_epjap_2008029 crossref_primary_10_1088_1681_7575_ab4533 crossref_primary_10_1088_0026_1394_43_2_S12 crossref_primary_10_1088_2040_8978_18_5_054014 crossref_primary_10_3390_rs12091454 crossref_primary_10_1103_PhysRevA_70_023801 crossref_primary_10_3788_gzxb20235212_1212002 crossref_primary_10_1088_0026_1394_45_4_002 crossref_primary_10_1103_PhysRevA_91_013808 crossref_primary_10_1103_PhysRevA_81_022108 crossref_primary_10_1088_0026_1394_51_6_S267 crossref_primary_10_1103_PhysRevA_94_033817 crossref_primary_10_1109_TIM_2005_843571 crossref_primary_10_1364_AO_58_009856 crossref_primary_10_1002_qute_202100008 crossref_primary_10_1364_AO_45_006947 |
ContentType | Journal Article |
DBID | NPM |
DOI | 10.1364/AO.41.002914 |
DatabaseName | PubMed |
DatabaseTitle | PubMed |
DatabaseTitleList | PubMed |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
Discipline | Physics |
ExternalDocumentID | 12027179 |
Genre | Journal Article |
GroupedDBID | 4.4 6J9 AAWJZ ACBEA ACGFO AENEX AKGWG ALMA_UNASSIGNED_HOLDINGS ATHME AYPRP AZSQR AZYMN DSZJF EJD NPM ODPQJ OFLFD OPJBK ROL ROP ROS TR6 UCJ X6Y Y7S |
ID | FETCH-LOGICAL-c287t-498d123b0a634715c3bb6e25df225b03b7b41fbec9d28c7eef4adfa389a851332 |
ISSN | 1559-128X |
IngestDate | Wed Oct 16 00:51:52 EDT 2024 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 15 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c287t-498d123b0a634715c3bb6e25df225b03b7b41fbec9d28c7eef4adfa389a851332 |
PMID | 12027179 |
ParticipantIDs | pubmed_primary_12027179 |
PublicationCentury | 2000 |
PublicationDate | 2002-May-20 |
PublicationDateYYYYMMDD | 2002-05-20 |
PublicationDate_xml | – month: 05 year: 2002 text: 2002-May-20 day: 20 |
PublicationDecade | 2000 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Applied optics (2004) |
PublicationTitleAlternate | Appl Opt |
PublicationYear | 2002 |
SSID | ssj0035497 |
Score | 1.9117659 |
Snippet | We report on the absolute calibration of photodetector quantum efficiency by using correlated photon sources, performed independently at two laboratories, the... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 2914 |
Title | Intercomparison of a correlated-photon-based method to measure detector quantum efficiency |
URI | https://www.ncbi.nlm.nih.gov/pubmed/12027179 |
Volume | 41 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9NAEF4loEq9VDza8tYeerPcxvb6dYwCKCBaOLRSxaXaZ7CU2BFxeuBn8IuZ2bUTx6UIOMSKvLbj7Hw7Ozs7Mx8hJ1Kmsc6N9hnI1Gcq4X6mI-lzHokR1v-KFLoGzi-S6RX7eB1fDwY_O1FL61qcyh-_zSv5H6nCOZArZsn-g2Q3D4UT8B3kC0eQMBz_SsbWnSe7TIKY64h8G3MwIZW__FYhQzDOVKrhikZbc-H8gp7StfXZY2YlTD0LDO4o7Fjf2ettDdVqaUs6g0mKvdNxIZwXM8Xd9sV4vkXbhK9sikptmZownszwsthMA2_1DANhS8sp5X24rbwvha6_V9udJ3t71WQUFdz7tC5WfMdNEeIOezjqatYYeRcsj_BG9bqaVy3E4q4izV1u6R0NHyUMK018PmUBOsN6l4F8lgsr7QC9OoEjqvlza6_edts0JMM0Q515gf4fN7dHsJq2dD3tn2lSKeClzrqvhKVom8f0livWbLl8RA6a9QYdO_A8JgNdPiF7Nu5Xrp6Srz0I0cpQTu-BEHUQonVFGwjRFkK0gRDdQuiQXL1_dzmZ-g3dhi9h2Vz7LM8U2DFixJMITJZYRkIkOoyVAZ0vRpFIBQsMjPlchZlMtTaMK8PB4uUZsgSFR-RBWZX6GaG5xDqIqdES1utCpFzBJ5ci5orBzwTPybHrlJulq6ly03bXi3tbXpL9La5ekYcGBrF-DRZhLd5YIf0CB6Rh8Q |
link.rule.ids | 786 |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Intercomparison+of+a+correlated-photon-based+method+to+measure+detector+quantum+efficiency&rft.jtitle=Applied+optics+%282004%29&rft.au=Migdall%2C+Alan&rft.au=Castelletto%2C+Stefania&rft.au=Degiovanni%2C+Ivo+Pietro&rft.au=Rastello%2C+Maria+Luisa&rft.date=2002-05-20&rft.issn=1559-128X&rft.volume=41&rft.issue=15&rft.spage=2914&rft_id=info:doi/10.1364%2FAO.41.002914&rft_id=info%3Apmid%2F12027179&rft_id=info%3Apmid%2F12027179&rft.externalDocID=12027179 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1559-128X&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1559-128X&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1559-128X&client=summon |