Neuroimaging Reader Study on Clinical Sensitivity and Specificity Using Synthetic MRI Based on MR Quantification
Prior large prospective studies have shown 2D synthetic MR image quality to be similar to that of conventional MR imaging across a wide variety of normal and abnormal subjects. This study is the first large, prospective comparison of 3D synthetic to conventional MR imaging performed in routine clini...
Saved in:
Published in | American journal of neuroradiology : AJNR Vol. 46; no. 6; pp. 1196 - 1202 |
---|---|
Main Authors | , , , , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
01.06.2025
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Prior large prospective studies have shown 2D synthetic MR image quality to be similar to that of conventional MR imaging across a wide variety of normal and abnormal subjects. This study is the first large, prospective comparison of 3D synthetic to conventional MR imaging performed in routine clinical settings.
A prospective, multicenter, multireader clinical investigation to evaluate the diagnostic performance of 3D synthetic images based on the novel synthetic MRI 3D-QALAS method compared with conventional 3D MRI was performed. Five blinded neuroradiologists evaluated the 3D synthetic and conventional MR images of 189 subjects who presented at clinical sites for neuroimaging. The objectives were to compare sensitivity and specificity of pathologic findings, accuracy of imaging findings, image quality, legibility of anatomic structures, artifact prevalence, and interrater and intermethod agreement of synthetic 3D MR images with conventional 3D images.
Both sensitivity and specificity of 3D synthetic and conventional images for pathologic findings and diagnostic accuracy of radiologic findings were very similar, 66/68% and 85/85%, respectively. The individual values for the readers varied between 58%-73%/58%-75% for sensitivity and 72%-98%/77%-94% for specificity. No significant difference could be determined between the methods. Ratings (1-5 scale) of synthetic MR image quality were higher than for T1-weighted images (mean score of 4.6 ± 0.6, with 98.6% having a 3 or higher versus 4.5 ± 0.7, with 97.8% having a 3 or higher) and T2-weighted images (4.4 ± 0.7, with 98.0% having a 3 or higher versus 4.2 ± 0.8, with 97.5% having a 3 or higher).
In this study no significant differences were found in the sensitivity and specificity of pathologic findings and accuracy of imaging findings between 3D synthetic T1-weighted and T2-weighted images and 3D conventional images. In addition, 5 blinded neuroradiologists rated 3D synthetic MR images of higher image quality than conventional 3D images. |
---|---|
AbstractList | Prior large prospective studies have shown 2D synthetic MR image quality to be similar to that of conventional MR imaging across a wide variety of normal and abnormal subjects. This study is the first large, prospective comparison of 3D synthetic to conventional MR imaging performed in routine clinical settings.
A prospective, multicenter, multireader clinical investigation to evaluate the diagnostic performance of 3D synthetic images based on the novel synthetic MRI 3D-QALAS method compared with conventional 3D MRI was performed. Five blinded neuroradiologists evaluated the 3D synthetic and conventional MR images of 189 subjects who presented at clinical sites for neuroimaging. The objectives were to compare sensitivity and specificity of pathologic findings, accuracy of imaging findings, image quality, legibility of anatomic structures, artifact prevalence, and interrater and intermethod agreement of synthetic 3D MR images with conventional 3D images.
Both sensitivity and specificity of 3D synthetic and conventional images for pathologic findings and diagnostic accuracy of radiologic findings were very similar, 66/68% and 85/85%, respectively. The individual values for the readers varied between 58%-73%/58%-75% for sensitivity and 72%-98%/77%-94% for specificity. No significant difference could be determined between the methods. Ratings (1-5 scale) of synthetic MR image quality were higher than for T1-weighted images (mean score of 4.6 ± 0.6, with 98.6% having a 3 or higher versus 4.5 ± 0.7, with 97.8% having a 3 or higher) and T2-weighted images (4.4 ± 0.7, with 98.0% having a 3 or higher versus 4.2 ± 0.8, with 97.5% having a 3 or higher).
In this study no significant differences were found in the sensitivity and specificity of pathologic findings and accuracy of imaging findings between 3D synthetic T1-weighted and T2-weighted images and 3D conventional images. In addition, 5 blinded neuroradiologists rated 3D synthetic MR images of higher image quality than conventional 3D images. Prior large prospective studies have shown 2D synthetic MR image quality to be similar to that of conventional MR imaging across a wide variety of normal and abnormal subjects. This study is the first large, prospective comparison of 3D synthetic to conventional MR imaging performed in routine clinical settings.BACKGROUND AND PURPOSEPrior large prospective studies have shown 2D synthetic MR image quality to be similar to that of conventional MR imaging across a wide variety of normal and abnormal subjects. This study is the first large, prospective comparison of 3D synthetic to conventional MR imaging performed in routine clinical settings.A prospective, multicenter, multireader clinical investigation to evaluate the diagnostic performance of 3D synthetic images based on the novel synthetic MRI 3D-QALAS method compared with conventional 3D MRI was performed. Five blinded neuroradiologists evaluated the 3D synthetic and conventional MR images of 189 subjects who presented at clinical sites for neuroimaging. The objectives were to compare sensitivity and specificity of pathologic findings, accuracy of imaging findings, image quality, legibility of anatomic structures, artifact prevalence, and interrater and intermethod agreement of synthetic 3D MR images with conventional 3D images.MATERIALS AND METHODSA prospective, multicenter, multireader clinical investigation to evaluate the diagnostic performance of 3D synthetic images based on the novel synthetic MRI 3D-QALAS method compared with conventional 3D MRI was performed. Five blinded neuroradiologists evaluated the 3D synthetic and conventional MR images of 189 subjects who presented at clinical sites for neuroimaging. The objectives were to compare sensitivity and specificity of pathologic findings, accuracy of imaging findings, image quality, legibility of anatomic structures, artifact prevalence, and interrater and intermethod agreement of synthetic 3D MR images with conventional 3D images.Both sensitivity and specificity of 3D synthetic and conventional images for pathologic findings and diagnostic accuracy of radiologic findings were very similar, 66/68% and 85/85%, respectively. The individual values for the readers varied between 58%-73%/58%-75% for sensitivity and 72%-98%/77%-94% for specificity. No significant difference could be determined between the methods. Ratings (1-5 scale) of synthetic MR image quality were higher than for T1-weighted images (mean score of 4.6 ± 0.6, with 98.6% having a 3 or higher versus 4.5 ± 0.7, with 97.8% having a 3 or higher) and T2-weighted images (4.4 ± 0.7, with 98.0% having a 3 or higher versus 4.2 ± 0.8, with 97.5% having a 3 or higher).RESULTSBoth sensitivity and specificity of 3D synthetic and conventional images for pathologic findings and diagnostic accuracy of radiologic findings were very similar, 66/68% and 85/85%, respectively. The individual values for the readers varied between 58%-73%/58%-75% for sensitivity and 72%-98%/77%-94% for specificity. No significant difference could be determined between the methods. Ratings (1-5 scale) of synthetic MR image quality were higher than for T1-weighted images (mean score of 4.6 ± 0.6, with 98.6% having a 3 or higher versus 4.5 ± 0.7, with 97.8% having a 3 or higher) and T2-weighted images (4.4 ± 0.7, with 98.0% having a 3 or higher versus 4.2 ± 0.8, with 97.5% having a 3 or higher).In this study no significant differences were found in the sensitivity and specificity of pathologic findings and accuracy of imaging findings between 3D synthetic T1-weighted and T2-weighted images and 3D conventional images. In addition, 5 blinded neuroradiologists rated 3D synthetic MR images of higher image quality than conventional 3D images.CONCLUSIONSIn this study no significant differences were found in the sensitivity and specificity of pathologic findings and accuracy of imaging findings between 3D synthetic T1-weighted and T2-weighted images and 3D conventional images. In addition, 5 blinded neuroradiologists rated 3D synthetic MR images of higher image quality than conventional 3D images. |
Author | Hayes, L. Cornejo, P. Mechtler, L. Lange, E. Snyder, T. Miller, J.H. Johansson, P. Pinter, N. Carpenter, J. Koral, K. Maulsby, G. Levendovszky, S.R. Lefkowitz, D. Warntjes, J.B.M. |
Author_xml | – sequence: 1 givenname: J.H. orcidid: 0000-0002-0018-2532 surname: Miller fullname: Miller, J.H. – sequence: 2 givenname: D. surname: Lefkowitz fullname: Lefkowitz, D. – sequence: 3 givenname: G. orcidid: 0009-0008-5819-3227 surname: Maulsby fullname: Maulsby, G. – sequence: 4 givenname: L. orcidid: 0000-0002-6105-9159 surname: Mechtler fullname: Mechtler, L. – sequence: 5 givenname: N. orcidid: 0000-0002-7714-143X surname: Pinter fullname: Pinter, N. – sequence: 6 givenname: T. surname: Snyder fullname: Snyder, T. – sequence: 7 givenname: L. surname: Hayes fullname: Hayes, L. – sequence: 8 givenname: J. surname: Carpenter fullname: Carpenter, J. – sequence: 9 givenname: K. surname: Koral fullname: Koral, K. – sequence: 10 givenname: P. orcidid: 0000-0001-5096-6047 surname: Cornejo fullname: Cornejo, P. – sequence: 11 givenname: S.R. orcidid: 0000-0001-8863-3168 surname: Levendovszky fullname: Levendovszky, S.R. – sequence: 12 givenname: J.B.M. orcidid: 0000-0002-3037-4201 surname: Warntjes fullname: Warntjes, J.B.M. – sequence: 13 givenname: P. orcidid: 0009-0005-9809-4758 surname: Johansson fullname: Johansson, P. – sequence: 14 givenname: E. orcidid: 0009-0003-1738-8478 surname: Lange fullname: Lange, E. |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/40404350$$D View this record in MEDLINE/PubMed |
BookMark | eNo9kV1LwzAUhoNM3Ife-AMklyJ0Jk3TNJdz-DGYiqsD70qaj5nRpbNJhf17VzflXBwOPOe9eJ8h6LnaaQAuMRoTzJJbsXbNeJKlBJ-AAeYkjTjlHz0wQJjTKMUo64Oh92uEEOUsPgP9BO2HUDQA2xfdNrXdiJV1K7jQQukG5qFVO1g7OK2ss1JUMNfO22C_bdhB4RTMt1paY2V3L333mu9c-NTBSvi8mME74bXqEp4X8K0VLnSwCLZ25-DUiMrri-MegeXD_fv0KZq_Ps6mk3kk4ywJEVe4xAYzobjKElZmkifKKFNSTQTFSUk5T4lm0pSGlgliChPOTCyNkJwqRkbg-pC7beqvVvtQbKyXuqqE03XrCxKjlGdpxpI9enVE23KjVbFt9n00u-KvpT1wcwBkU3vfaPOPYFR0CopOQfGrgPwA9UV6uw |
Cites_doi | 10.1007/s00234-022-02973-2 10.1080/19585969.2022.12130515 10.1186/s12968-014-0102-0 10.3174/ajnr.A4665 10.1007/s00234-016-1723-9 10.3174/ajnr.A5815 10.1016/j.mri.2016.12.014 10.3325/cmj.2011.52.488 10.1007/s00234-022-03031-7 10.1097/RLI.0000000000000365 10.2500/ajra.2013.27.3931 10.1038/nature11971 10.3174/ajnr.A5227 10.1002/mrm.21635 10.1002/mrm.20314 10.1016/j.mri.2019.08.031 10.3174/ajnr.A5012 |
ContentType | Journal Article |
Copyright | 2025 by American Journal of Neuroradiology. |
Copyright_xml | – notice: 2025 by American Journal of Neuroradiology. |
DBID | AAYXX CITATION CGR CUY CVF ECM EIF NPM 7X8 |
DOI | 10.3174/ajnr.A8631 |
DatabaseName | CrossRef Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed MEDLINE - Academic |
DatabaseTitle | CrossRef MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) MEDLINE - Academic |
DatabaseTitleList | MEDLINE MEDLINE - Academic |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1936-959X |
EndPage | 1202 |
ExternalDocumentID | 40404350 10_3174_ajnr_A8631 |
Genre | Multicenter Study Journal Article |
GroupedDBID | --- .55 .GJ 23M 2WC 53G 5GY 5RE 5VS 6J9 AAEJM AAYXX ACGFO ACIWK ACPRK ADBBV AENEX AFFNX AFHIN AFRAH AJJEV ALMA_UNASSIGNED_HOLDINGS BAWUL BTFSW C1A CITATION CS3 E3Z EBS EJD EMOBN F5P F9R GX1 H13 INIJC KQ8 MV1 N9A OK1 P2P P6G R0Z RHI RPM TNE TR2 UDS W8F WOQ WOW X7M ZCG ZGI ZXP CGR CUY CVF ECM EIF NPM 7X8 |
ID | FETCH-LOGICAL-c284t-9d1b1f17ad9d847b8c94dfdfb5e3a514b59963e7cfbf5b407d1397f2cfac95d73 |
ISSN | 0195-6108 1936-959X |
IngestDate | Fri May 23 17:31:40 EDT 2025 Thu Jul 10 06:18:36 EDT 2025 Thu Jul 03 08:44:04 EDT 2025 |
IsDoiOpenAccess | false |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 6 |
Language | English |
License | 2025 by American Journal of Neuroradiology. |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c284t-9d1b1f17ad9d847b8c94dfdfb5e3a514b59963e7cfbf5b407d1397f2cfac95d73 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ORCID | 0009-0008-5819-3227 0000-0002-3037-4201 0000-0002-6105-9159 0009-0005-9809-4758 0009-0003-1738-8478 0000-0002-7714-143X 0000-0001-8863-3168 0000-0001-5096-6047 0000-0002-0018-2532 |
OpenAccessLink | https://doi.org/10.3174/ajnr.a8631 |
PMID | 40404350 |
PQID | 3206986874 |
PQPubID | 23479 |
PageCount | 7 |
ParticipantIDs | proquest_miscellaneous_3206986874 pubmed_primary_40404350 crossref_primary_10_3174_ajnr_A8631 |
PublicationCentury | 2000 |
PublicationDate | 2025-06-01 |
PublicationDateYYYYMMDD | 2025-06-01 |
PublicationDate_xml | – month: 06 year: 2025 text: 2025-06-01 day: 01 |
PublicationDecade | 2020 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | American journal of neuroradiology : AJNR |
PublicationTitleAlternate | AJNR Am J Neuroradiol |
PublicationYear | 2025 |
References | 2025060911101699000_46.6.1196.15 2025060911101699000_46.6.1196.16 2025060911101699000_46.6.1196.17 2025060911101699000_46.6.1196.18 2025060911101699000_46.6.1196.11 2025060911101699000_46.6.1196.12 2025060911101699000_46.6.1196.8 Bobman (2025060911101699000_46.6.1196.9) 1985; 6 2025060911101699000_46.6.1196.13 2025060911101699000_46.6.1196.14 2025060911101699000_46.6.1196.6 2025060911101699000_46.6.1196.7 2025060911101699000_46.6.1196.4 2025060911101699000_46.6.1196.5 2025060911101699000_46.6.1196.2 2025060911101699000_46.6.1196.3 2025060911101699000_46.6.1196.1 2025060911101699000_46.6.1196.10 |
References_xml | – ident: 2025060911101699000_46.6.1196.11 doi: 10.1007/s00234-022-02973-2 – ident: 2025060911101699000_46.6.1196.15 doi: 10.1080/19585969.2022.12130515 – ident: 2025060911101699000_46.6.1196.4 doi: 10.1186/s12968-014-0102-0 – ident: 2025060911101699000_46.6.1196.7 doi: 10.3174/ajnr.A4665 – ident: 2025060911101699000_46.6.1196.13 doi: 10.1007/s00234-016-1723-9 – ident: 2025060911101699000_46.6.1196.12 doi: 10.3174/ajnr.A5815 – ident: 2025060911101699000_46.6.1196.5 doi: 10.1016/j.mri.2016.12.014 – ident: 2025060911101699000_46.6.1196.16 doi: 10.3325/cmj.2011.52.488 – ident: 2025060911101699000_46.6.1196.18 doi: 10.1007/s00234-022-03031-7 – ident: 2025060911101699000_46.6.1196.8 doi: 10.1097/RLI.0000000000000365 – ident: 2025060911101699000_46.6.1196.14 doi: 10.2500/ajra.2013.27.3931 – ident: 2025060911101699000_46.6.1196.2 doi: 10.1038/nature11971 – volume: 6 start-page: 265 year: 1985 ident: 2025060911101699000_46.6.1196.9 article-title: Cerebral magnetic resonance image synthesis publication-title: AJR AJNR Am J Neuroradiol – ident: 2025060911101699000_46.6.1196.10 doi: 10.3174/ajnr.A5227 – ident: 2025060911101699000_46.6.1196.1 doi: 10.1002/mrm.21635 – ident: 2025060911101699000_46.6.1196.3 doi: 10.1002/mrm.20314 – ident: 2025060911101699000_46.6.1196.6 doi: 10.1016/j.mri.2019.08.031 – ident: 2025060911101699000_46.6.1196.17 doi: 10.3174/ajnr.A5012 |
SSID | ssj0005972 |
Score | 2.46785 |
Snippet | Prior large prospective studies have shown 2D synthetic MR image quality to be similar to that of conventional MR imaging across a wide variety of normal and... |
SourceID | proquest pubmed crossref |
SourceType | Aggregation Database Index Database |
StartPage | 1196 |
SubjectTerms | Adolescent Adult Aged Aged, 80 and over Female Humans Image Interpretation, Computer-Assisted - methods Imaging, Three-Dimensional - methods Magnetic Resonance Imaging - methods Male Middle Aged Neuroimaging - methods Observer Variation Prospective Studies Reproducibility of Results Sensitivity and Specificity Young Adult |
Title | Neuroimaging Reader Study on Clinical Sensitivity and Specificity Using Synthetic MRI Based on MR Quantification |
URI | https://www.ncbi.nlm.nih.gov/pubmed/40404350 https://www.proquest.com/docview/3206986874 |
Volume | 46 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1bb9MwFLbKkBAvE3fKTUbwNqUkcRLHj2NcSiGT6DZpb5Ht2KIw0qmkQuPn8Es5x7mWgjR4iVpLdhSfT_Y59ne-Q8hzFamIGet7AA48rZKhJ0WaeIkw0oLLq3WMCc7ZYTI9iWan8elo9HPAWlpXaqJ__DGv5H-sCm1gV8yS_QfLdoNCA_wG-8ITLAzPS9nYKWssvtaFhuaOlOyIgRd4BXDQ5jweIUe9KRLhiJpYch6FI-B_zRg4uijBD0Tp1mz-bu8lbGwFjpDNkfNZs4l6A7aSte1Vz0B7woljrmTRCDu5Q8fZYU_s7fIOZ5PppKcC2S_L7wtXV3bvVdecyfVZI_v5tm80-lPVjPFhMjyxCOOeWdUeYooYQla_XndNvfAKlngidmV1u5W5OZxcbC2zQSCSwZYdhC5re2s7AN8owr3uc7ma7KdJs91saG7_thd2DEWIjbB3jn1z1_cKuRpCKIJVMt5_7BXpISAL25qX-E21BC72fdG_d9Pp-Usk4zya4xtktwlF6H6Nq5tkZMpb5FrWkC1uk_MhvGgNL-rgRZclbeFFB_CiAC86gBd18KIdvCjAizp44QjZnG7C6w45efP6-GDqNQU6PA1eTeWJIlCBDbgsRAFejkq1iApbWBUbJsETV6j9wwzXVtlYRT4vMN6wobZSi7jg7C7ZKZeluU-o72uVch1KyVhkma8497kFX5kzoWWajsmzdgbz81qHJd-20Zg8bSc3h2US775kaZbrbzkL_QTWoJRHY3KvnvVunMhHianYf3Cpdzwk13tQPyI71WptHoNjWqknDhm_ALNFkUQ |
linkProvider | Colorado Alliance of Research Libraries |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Neuroimaging+Reader+Study+on+Clinical+Sensitivity+and+Specificity+Using+Synthetic+MRI+Based+on+MR+Quantification&rft.jtitle=American+journal+of+neuroradiology+%3A+AJNR&rft.au=Miller%2C+J.H.&rft.au=Lefkowitz%2C+D.&rft.au=Maulsby%2C+G.&rft.au=Mechtler%2C+L.&rft.date=2025-06-01&rft.issn=0195-6108&rft.eissn=1936-959X&rft.volume=46&rft.issue=6&rft.spage=1196&rft.epage=1202&rft_id=info:doi/10.3174%2Fajnr.A8631&rft.externalDBID=n%2Fa&rft.externalDocID=10_3174_ajnr_A8631 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0195-6108&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0195-6108&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0195-6108&client=summon |