Neuroimaging Reader Study on Clinical Sensitivity and Specificity Using Synthetic MRI Based on MR Quantification

Prior large prospective studies have shown 2D synthetic MR image quality to be similar to that of conventional MR imaging across a wide variety of normal and abnormal subjects. This study is the first large, prospective comparison of 3D synthetic to conventional MR imaging performed in routine clini...

Full description

Saved in:
Bibliographic Details
Published inAmerican journal of neuroradiology : AJNR Vol. 46; no. 6; pp. 1196 - 1202
Main Authors Miller, J.H., Lefkowitz, D., Maulsby, G., Mechtler, L., Pinter, N., Snyder, T., Hayes, L., Carpenter, J., Koral, K., Cornejo, P., Levendovszky, S.R., Warntjes, J.B.M., Johansson, P., Lange, E.
Format Journal Article
LanguageEnglish
Published United States 01.06.2025
Subjects
Online AccessGet full text

Cover

Loading…
Abstract Prior large prospective studies have shown 2D synthetic MR image quality to be similar to that of conventional MR imaging across a wide variety of normal and abnormal subjects. This study is the first large, prospective comparison of 3D synthetic to conventional MR imaging performed in routine clinical settings. A prospective, multicenter, multireader clinical investigation to evaluate the diagnostic performance of 3D synthetic images based on the novel synthetic MRI 3D-QALAS method compared with conventional 3D MRI was performed. Five blinded neuroradiologists evaluated the 3D synthetic and conventional MR images of 189 subjects who presented at clinical sites for neuroimaging. The objectives were to compare sensitivity and specificity of pathologic findings, accuracy of imaging findings, image quality, legibility of anatomic structures, artifact prevalence, and interrater and intermethod agreement of synthetic 3D MR images with conventional 3D images. Both sensitivity and specificity of 3D synthetic and conventional images for pathologic findings and diagnostic accuracy of radiologic findings were very similar, 66/68% and 85/85%, respectively. The individual values for the readers varied between 58%-73%/58%-75% for sensitivity and 72%-98%/77%-94% for specificity. No significant difference could be determined between the methods. Ratings (1-5 scale) of synthetic MR image quality were higher than for T1-weighted images (mean score of 4.6 ± 0.6, with 98.6% having a 3 or higher versus 4.5 ± 0.7, with 97.8% having a 3 or higher) and T2-weighted images (4.4 ± 0.7, with 98.0% having a 3 or higher versus 4.2 ± 0.8, with 97.5% having a 3 or higher). In this study no significant differences were found in the sensitivity and specificity of pathologic findings and accuracy of imaging findings between 3D synthetic T1-weighted and T2-weighted images and 3D conventional images. In addition, 5 blinded neuroradiologists rated 3D synthetic MR images of higher image quality than conventional 3D images.
AbstractList Prior large prospective studies have shown 2D synthetic MR image quality to be similar to that of conventional MR imaging across a wide variety of normal and abnormal subjects. This study is the first large, prospective comparison of 3D synthetic to conventional MR imaging performed in routine clinical settings. A prospective, multicenter, multireader clinical investigation to evaluate the diagnostic performance of 3D synthetic images based on the novel synthetic MRI 3D-QALAS method compared with conventional 3D MRI was performed. Five blinded neuroradiologists evaluated the 3D synthetic and conventional MR images of 189 subjects who presented at clinical sites for neuroimaging. The objectives were to compare sensitivity and specificity of pathologic findings, accuracy of imaging findings, image quality, legibility of anatomic structures, artifact prevalence, and interrater and intermethod agreement of synthetic 3D MR images with conventional 3D images. Both sensitivity and specificity of 3D synthetic and conventional images for pathologic findings and diagnostic accuracy of radiologic findings were very similar, 66/68% and 85/85%, respectively. The individual values for the readers varied between 58%-73%/58%-75% for sensitivity and 72%-98%/77%-94% for specificity. No significant difference could be determined between the methods. Ratings (1-5 scale) of synthetic MR image quality were higher than for T1-weighted images (mean score of 4.6 ± 0.6, with 98.6% having a 3 or higher versus 4.5 ± 0.7, with 97.8% having a 3 or higher) and T2-weighted images (4.4 ± 0.7, with 98.0% having a 3 or higher versus 4.2 ± 0.8, with 97.5% having a 3 or higher). In this study no significant differences were found in the sensitivity and specificity of pathologic findings and accuracy of imaging findings between 3D synthetic T1-weighted and T2-weighted images and 3D conventional images. In addition, 5 blinded neuroradiologists rated 3D synthetic MR images of higher image quality than conventional 3D images.
Prior large prospective studies have shown 2D synthetic MR image quality to be similar to that of conventional MR imaging across a wide variety of normal and abnormal subjects. This study is the first large, prospective comparison of 3D synthetic to conventional MR imaging performed in routine clinical settings.BACKGROUND AND PURPOSEPrior large prospective studies have shown 2D synthetic MR image quality to be similar to that of conventional MR imaging across a wide variety of normal and abnormal subjects. This study is the first large, prospective comparison of 3D synthetic to conventional MR imaging performed in routine clinical settings.A prospective, multicenter, multireader clinical investigation to evaluate the diagnostic performance of 3D synthetic images based on the novel synthetic MRI 3D-QALAS method compared with conventional 3D MRI was performed. Five blinded neuroradiologists evaluated the 3D synthetic and conventional MR images of 189 subjects who presented at clinical sites for neuroimaging. The objectives were to compare sensitivity and specificity of pathologic findings, accuracy of imaging findings, image quality, legibility of anatomic structures, artifact prevalence, and interrater and intermethod agreement of synthetic 3D MR images with conventional 3D images.MATERIALS AND METHODSA prospective, multicenter, multireader clinical investigation to evaluate the diagnostic performance of 3D synthetic images based on the novel synthetic MRI 3D-QALAS method compared with conventional 3D MRI was performed. Five blinded neuroradiologists evaluated the 3D synthetic and conventional MR images of 189 subjects who presented at clinical sites for neuroimaging. The objectives were to compare sensitivity and specificity of pathologic findings, accuracy of imaging findings, image quality, legibility of anatomic structures, artifact prevalence, and interrater and intermethod agreement of synthetic 3D MR images with conventional 3D images.Both sensitivity and specificity of 3D synthetic and conventional images for pathologic findings and diagnostic accuracy of radiologic findings were very similar, 66/68% and 85/85%, respectively. The individual values for the readers varied between 58%-73%/58%-75% for sensitivity and 72%-98%/77%-94% for specificity. No significant difference could be determined between the methods. Ratings (1-5 scale) of synthetic MR image quality were higher than for T1-weighted images (mean score of 4.6 ± 0.6, with 98.6% having a 3 or higher versus 4.5 ± 0.7, with 97.8% having a 3 or higher) and T2-weighted images (4.4 ± 0.7, with 98.0% having a 3 or higher versus 4.2 ± 0.8, with 97.5% having a 3 or higher).RESULTSBoth sensitivity and specificity of 3D synthetic and conventional images for pathologic findings and diagnostic accuracy of radiologic findings were very similar, 66/68% and 85/85%, respectively. The individual values for the readers varied between 58%-73%/58%-75% for sensitivity and 72%-98%/77%-94% for specificity. No significant difference could be determined between the methods. Ratings (1-5 scale) of synthetic MR image quality were higher than for T1-weighted images (mean score of 4.6 ± 0.6, with 98.6% having a 3 or higher versus 4.5 ± 0.7, with 97.8% having a 3 or higher) and T2-weighted images (4.4 ± 0.7, with 98.0% having a 3 or higher versus 4.2 ± 0.8, with 97.5% having a 3 or higher).In this study no significant differences were found in the sensitivity and specificity of pathologic findings and accuracy of imaging findings between 3D synthetic T1-weighted and T2-weighted images and 3D conventional images. In addition, 5 blinded neuroradiologists rated 3D synthetic MR images of higher image quality than conventional 3D images.CONCLUSIONSIn this study no significant differences were found in the sensitivity and specificity of pathologic findings and accuracy of imaging findings between 3D synthetic T1-weighted and T2-weighted images and 3D conventional images. In addition, 5 blinded neuroradiologists rated 3D synthetic MR images of higher image quality than conventional 3D images.
Author Hayes, L.
Cornejo, P.
Mechtler, L.
Lange, E.
Snyder, T.
Miller, J.H.
Johansson, P.
Pinter, N.
Carpenter, J.
Koral, K.
Maulsby, G.
Levendovszky, S.R.
Lefkowitz, D.
Warntjes, J.B.M.
Author_xml – sequence: 1
  givenname: J.H.
  orcidid: 0000-0002-0018-2532
  surname: Miller
  fullname: Miller, J.H.
– sequence: 2
  givenname: D.
  surname: Lefkowitz
  fullname: Lefkowitz, D.
– sequence: 3
  givenname: G.
  orcidid: 0009-0008-5819-3227
  surname: Maulsby
  fullname: Maulsby, G.
– sequence: 4
  givenname: L.
  orcidid: 0000-0002-6105-9159
  surname: Mechtler
  fullname: Mechtler, L.
– sequence: 5
  givenname: N.
  orcidid: 0000-0002-7714-143X
  surname: Pinter
  fullname: Pinter, N.
– sequence: 6
  givenname: T.
  surname: Snyder
  fullname: Snyder, T.
– sequence: 7
  givenname: L.
  surname: Hayes
  fullname: Hayes, L.
– sequence: 8
  givenname: J.
  surname: Carpenter
  fullname: Carpenter, J.
– sequence: 9
  givenname: K.
  surname: Koral
  fullname: Koral, K.
– sequence: 10
  givenname: P.
  orcidid: 0000-0001-5096-6047
  surname: Cornejo
  fullname: Cornejo, P.
– sequence: 11
  givenname: S.R.
  orcidid: 0000-0001-8863-3168
  surname: Levendovszky
  fullname: Levendovszky, S.R.
– sequence: 12
  givenname: J.B.M.
  orcidid: 0000-0002-3037-4201
  surname: Warntjes
  fullname: Warntjes, J.B.M.
– sequence: 13
  givenname: P.
  orcidid: 0009-0005-9809-4758
  surname: Johansson
  fullname: Johansson, P.
– sequence: 14
  givenname: E.
  orcidid: 0009-0003-1738-8478
  surname: Lange
  fullname: Lange, E.
BackLink https://www.ncbi.nlm.nih.gov/pubmed/40404350$$D View this record in MEDLINE/PubMed
BookMark eNo9kV1LwzAUhoNM3Ife-AMklyJ0Jk3TNJdz-DGYiqsD70qaj5nRpbNJhf17VzflXBwOPOe9eJ8h6LnaaQAuMRoTzJJbsXbNeJKlBJ-AAeYkjTjlHz0wQJjTKMUo64Oh92uEEOUsPgP9BO2HUDQA2xfdNrXdiJV1K7jQQukG5qFVO1g7OK2ss1JUMNfO22C_bdhB4RTMt1paY2V3L333mu9c-NTBSvi8mME74bXqEp4X8K0VLnSwCLZ25-DUiMrri-MegeXD_fv0KZq_Ps6mk3kk4ywJEVe4xAYzobjKElZmkifKKFNSTQTFSUk5T4lm0pSGlgliChPOTCyNkJwqRkbg-pC7beqvVvtQbKyXuqqE03XrCxKjlGdpxpI9enVE23KjVbFt9n00u-KvpT1wcwBkU3vfaPOPYFR0CopOQfGrgPwA9UV6uw
Cites_doi 10.1007/s00234-022-02973-2
10.1080/19585969.2022.12130515
10.1186/s12968-014-0102-0
10.3174/ajnr.A4665
10.1007/s00234-016-1723-9
10.3174/ajnr.A5815
10.1016/j.mri.2016.12.014
10.3325/cmj.2011.52.488
10.1007/s00234-022-03031-7
10.1097/RLI.0000000000000365
10.2500/ajra.2013.27.3931
10.1038/nature11971
10.3174/ajnr.A5227
10.1002/mrm.21635
10.1002/mrm.20314
10.1016/j.mri.2019.08.031
10.3174/ajnr.A5012
ContentType Journal Article
Copyright 2025 by American Journal of Neuroradiology.
Copyright_xml – notice: 2025 by American Journal of Neuroradiology.
DBID AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
7X8
DOI 10.3174/ajnr.A8631
DatabaseName CrossRef
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
MEDLINE - Academic
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
MEDLINE - Academic
DatabaseTitleList MEDLINE
MEDLINE - Academic
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1936-959X
EndPage 1202
ExternalDocumentID 40404350
10_3174_ajnr_A8631
Genre Multicenter Study
Journal Article
GroupedDBID ---
.55
.GJ
23M
2WC
53G
5GY
5RE
5VS
6J9
AAEJM
AAYXX
ACGFO
ACIWK
ACPRK
ADBBV
AENEX
AFFNX
AFHIN
AFRAH
AJJEV
ALMA_UNASSIGNED_HOLDINGS
BAWUL
BTFSW
C1A
CITATION
CS3
E3Z
EBS
EJD
EMOBN
F5P
F9R
GX1
H13
INIJC
KQ8
MV1
N9A
OK1
P2P
P6G
R0Z
RHI
RPM
TNE
TR2
UDS
W8F
WOQ
WOW
X7M
ZCG
ZGI
ZXP
CGR
CUY
CVF
ECM
EIF
NPM
7X8
ID FETCH-LOGICAL-c284t-9d1b1f17ad9d847b8c94dfdfb5e3a514b59963e7cfbf5b407d1397f2cfac95d73
ISSN 0195-6108
1936-959X
IngestDate Fri May 23 17:31:40 EDT 2025
Thu Jul 10 06:18:36 EDT 2025
Thu Jul 03 08:44:04 EDT 2025
IsDoiOpenAccess false
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 6
Language English
License 2025 by American Journal of Neuroradiology.
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c284t-9d1b1f17ad9d847b8c94dfdfb5e3a514b59963e7cfbf5b407d1397f2cfac95d73
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ORCID 0009-0008-5819-3227
0000-0002-3037-4201
0000-0002-6105-9159
0009-0005-9809-4758
0009-0003-1738-8478
0000-0002-7714-143X
0000-0001-8863-3168
0000-0001-5096-6047
0000-0002-0018-2532
OpenAccessLink https://doi.org/10.3174/ajnr.a8631
PMID 40404350
PQID 3206986874
PQPubID 23479
PageCount 7
ParticipantIDs proquest_miscellaneous_3206986874
pubmed_primary_40404350
crossref_primary_10_3174_ajnr_A8631
PublicationCentury 2000
PublicationDate 2025-06-01
PublicationDateYYYYMMDD 2025-06-01
PublicationDate_xml – month: 06
  year: 2025
  text: 2025-06-01
  day: 01
PublicationDecade 2020
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle American journal of neuroradiology : AJNR
PublicationTitleAlternate AJNR Am J Neuroradiol
PublicationYear 2025
References 2025060911101699000_46.6.1196.15
2025060911101699000_46.6.1196.16
2025060911101699000_46.6.1196.17
2025060911101699000_46.6.1196.18
2025060911101699000_46.6.1196.11
2025060911101699000_46.6.1196.12
2025060911101699000_46.6.1196.8
Bobman (2025060911101699000_46.6.1196.9) 1985; 6
2025060911101699000_46.6.1196.13
2025060911101699000_46.6.1196.14
2025060911101699000_46.6.1196.6
2025060911101699000_46.6.1196.7
2025060911101699000_46.6.1196.4
2025060911101699000_46.6.1196.5
2025060911101699000_46.6.1196.2
2025060911101699000_46.6.1196.3
2025060911101699000_46.6.1196.1
2025060911101699000_46.6.1196.10
References_xml – ident: 2025060911101699000_46.6.1196.11
  doi: 10.1007/s00234-022-02973-2
– ident: 2025060911101699000_46.6.1196.15
  doi: 10.1080/19585969.2022.12130515
– ident: 2025060911101699000_46.6.1196.4
  doi: 10.1186/s12968-014-0102-0
– ident: 2025060911101699000_46.6.1196.7
  doi: 10.3174/ajnr.A4665
– ident: 2025060911101699000_46.6.1196.13
  doi: 10.1007/s00234-016-1723-9
– ident: 2025060911101699000_46.6.1196.12
  doi: 10.3174/ajnr.A5815
– ident: 2025060911101699000_46.6.1196.5
  doi: 10.1016/j.mri.2016.12.014
– ident: 2025060911101699000_46.6.1196.16
  doi: 10.3325/cmj.2011.52.488
– ident: 2025060911101699000_46.6.1196.18
  doi: 10.1007/s00234-022-03031-7
– ident: 2025060911101699000_46.6.1196.8
  doi: 10.1097/RLI.0000000000000365
– ident: 2025060911101699000_46.6.1196.14
  doi: 10.2500/ajra.2013.27.3931
– ident: 2025060911101699000_46.6.1196.2
  doi: 10.1038/nature11971
– volume: 6
  start-page: 265
  year: 1985
  ident: 2025060911101699000_46.6.1196.9
  article-title: Cerebral magnetic resonance image synthesis
  publication-title: AJR AJNR Am J Neuroradiol
– ident: 2025060911101699000_46.6.1196.10
  doi: 10.3174/ajnr.A5227
– ident: 2025060911101699000_46.6.1196.1
  doi: 10.1002/mrm.21635
– ident: 2025060911101699000_46.6.1196.3
  doi: 10.1002/mrm.20314
– ident: 2025060911101699000_46.6.1196.6
  doi: 10.1016/j.mri.2019.08.031
– ident: 2025060911101699000_46.6.1196.17
  doi: 10.3174/ajnr.A5012
SSID ssj0005972
Score 2.46785
Snippet Prior large prospective studies have shown 2D synthetic MR image quality to be similar to that of conventional MR imaging across a wide variety of normal and...
SourceID proquest
pubmed
crossref
SourceType Aggregation Database
Index Database
StartPage 1196
SubjectTerms Adolescent
Adult
Aged
Aged, 80 and over
Female
Humans
Image Interpretation, Computer-Assisted - methods
Imaging, Three-Dimensional - methods
Magnetic Resonance Imaging - methods
Male
Middle Aged
Neuroimaging - methods
Observer Variation
Prospective Studies
Reproducibility of Results
Sensitivity and Specificity
Young Adult
Title Neuroimaging Reader Study on Clinical Sensitivity and Specificity Using Synthetic MRI Based on MR Quantification
URI https://www.ncbi.nlm.nih.gov/pubmed/40404350
https://www.proquest.com/docview/3206986874
Volume 46
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1bb9MwFLbKkBAvE3fKTUbwNqUkcRLHj2NcSiGT6DZpb5Ht2KIw0qmkQuPn8Es5x7mWgjR4iVpLdhSfT_Y59ne-Q8hzFamIGet7AA48rZKhJ0WaeIkw0oLLq3WMCc7ZYTI9iWan8elo9HPAWlpXaqJ__DGv5H-sCm1gV8yS_QfLdoNCA_wG-8ITLAzPS9nYKWssvtaFhuaOlOyIgRd4BXDQ5jweIUe9KRLhiJpYch6FI-B_zRg4uijBD0Tp1mz-bu8lbGwFjpDNkfNZs4l6A7aSte1Vz0B7woljrmTRCDu5Q8fZYU_s7fIOZ5PppKcC2S_L7wtXV3bvVdecyfVZI_v5tm80-lPVjPFhMjyxCOOeWdUeYooYQla_XndNvfAKlngidmV1u5W5OZxcbC2zQSCSwZYdhC5re2s7AN8owr3uc7ma7KdJs91saG7_thd2DEWIjbB3jn1z1_cKuRpCKIJVMt5_7BXpISAL25qX-E21BC72fdG_d9Pp-Usk4zya4xtktwlF6H6Nq5tkZMpb5FrWkC1uk_MhvGgNL-rgRZclbeFFB_CiAC86gBd18KIdvCjAizp44QjZnG7C6w45efP6-GDqNQU6PA1eTeWJIlCBDbgsRAFejkq1iApbWBUbJsETV6j9wwzXVtlYRT4vMN6wobZSi7jg7C7ZKZeluU-o72uVch1KyVhkma8497kFX5kzoWWajsmzdgbz81qHJd-20Zg8bSc3h2US775kaZbrbzkL_QTWoJRHY3KvnvVunMhHianYf3Cpdzwk13tQPyI71WptHoNjWqknDhm_ALNFkUQ
linkProvider Colorado Alliance of Research Libraries
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Neuroimaging+Reader+Study+on+Clinical+Sensitivity+and+Specificity+Using+Synthetic+MRI+Based+on+MR+Quantification&rft.jtitle=American+journal+of+neuroradiology+%3A+AJNR&rft.au=Miller%2C+J.H.&rft.au=Lefkowitz%2C+D.&rft.au=Maulsby%2C+G.&rft.au=Mechtler%2C+L.&rft.date=2025-06-01&rft.issn=0195-6108&rft.eissn=1936-959X&rft.volume=46&rft.issue=6&rft.spage=1196&rft.epage=1202&rft_id=info:doi/10.3174%2Fajnr.A8631&rft.externalDBID=n%2Fa&rft.externalDocID=10_3174_ajnr_A8631
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0195-6108&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0195-6108&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0195-6108&client=summon